IST IST /110 IST /220

Similar documents
CONTENTS NBM-06 Bell (6") Page 1

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

INPUT / OUTPUT MINI MODULES

FlexSQUARE Square shaped beacons

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Intellia Sounder Bases and Sounder Beacon Bases

LEAKSTOPPER RANGE Multizone water leak detection systems

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Sounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity

Fill Point, Level Gauges, and Control Range

Series 65 Product Guide MAN 3036

Conventional Smoke Detectors KFAPO

The complete conventional fire warning system

INSTRUCTION MANUAL (ATEX)

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Industries. As a premier global manufacturing company, we believe that great brands are

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

INSTRUCTION & SERVICE MANUAL

D720 and D1255 Command Centers

Gate Mount Pool Alarms

IQ8Control C Fire Alarm Panel

4) Intrinsic Safety Certification

Hardwired Alarm Accessories

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

OPERATION AND INSTALLATION MANUAL

Consumer Products Catalog

Vibratone Horns. Models 350 and 450

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Emergi-Lite Orbis detectors

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Conventional Fire Detection

FOR TM-16 EMERGENCY WARNING SYSTEM

Interface and EOL Modules 8

FireLock High Pressure Butterfly Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

Excel-EN Conventional Fire Control Panel

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

Intelligent Security & Fire Ltd

Half-Dome. the Design-Tower. Compact

Addressable and Conventional Fire Protection

Process Alarm Module RTA 421

4 wire conventional alarm system

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

INSTRUCTION MANUAL (ATEX / IECEx)

DICTATOR Hold-Open Systems for Hazardous Areas

Snifter ATEX22 VERSION. User Manual. Distributor

Bulletin 855T 70 mm Control Tower Stack Lights

EFBW series - BiWire Ultra control panel

Xenex Conventional Fire Detection & Alarm System

CM800 Emergency Call System

Tek-ENTRY Apartment Entry Systems

TX6831 Data Sheet. Features. Benefits

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

LEAKSTOPPER 1 Single zone water leak detection system

Topscan G3 Presence detector for automatic doors

2G & 3G GSM Door Contact Alarm

Taps, Shower & Flush Valve Range

standards: standards:

E2S Datasheet v10a

SOUNDER BASES AND SOUNDER BEACON BASES

Precept Marine Control Panel Application Guide

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Vibratone Horns. Models 350 and 450

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

Series M22 Signaling Beacons and Alarms

Product Manual Standard Asserta Sounder Range

Ultrasonic Proximity Sensor

Reliably Advanced Extinguishing Control

INSTRUCTION & SERVICE MANUAL

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Audible warning devices for external alarm

SOLID PLUS HEAT

STANDARD FEATURES SPECIFICATIONS

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

Introduction to Flow Switch

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

So hot, so quick! Venus Water Heaters presents the Quik series, a range of tankless water heaters with the latest heat exchanger technology.

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Bristol Babcock Oil Content Monitor "oil in water"

Houses, farms, caravans, boats, buses and RV s, campervans, camper trailers, 4WD s and trucks, cabins, cars and tiny houses, hinterland retreats,

Rules for Intruder Alarm Systems

Slimline, Energy Saving & Smart. It's the game changer!

Fire Signalling. Signalling Solutions

Transcription:

IST-07-11160 IST-07-11160/110 IST-07-11160/220 Electroimán retenedor de puertas 60kg Electromagnetic Door Holders IST-0711160 are attractively designed and ruggedly constructed. The contact plate can be adjusted to suit any door angle. Electromagnetic Door Holders have a minimum holding force of approximately 35/50kg and can hold most type of doors. In application, the device releases the door when signaled by the fire alarm system, which then allows the door closing mechanism to close the door. This unit also have a Manual Release Switch to release the door manually or to test the operation of the unit. Each unit has a built-in electronic circuit that is designed for better reliability and performance. Incorporation of manual release switch Residual magnetism release electronic circuit for instant release Wide angle rotateable contact plate High holding force Supply voltage Supply current Input power Holding force Net/Gross weight 24V DC 110VAC 220VAC 60 ma 1.5 W 35/60 Kg minimum 652/690 g SUITABLE FOR INDOOR APPLICATION

Rotulas de longitudes especiales para retenedores de puertas Standard Ref. IST-07-11160 IST-09-R033 Longitud: 280mm IST-09-R028 Longitud: 230mm IST-09-R025 Longitud: 200mm IST-09-R020 Longitud: 150mm

IST-07-1160 IST-09-R100 IST-09-11100

IST-07-10224/24/6 IST-07-10224/110/8 IST-07-10224/220/4 Campanas de Alarma de 4 /6 /8 Alarm bells are professionally designed to meet the needs of fire fighting and detection system with central control equipment. The simplicity of the design incorporates fewer working parts, easy installation and high level of efficiency, thus making the bells capable for operating under most adverse conditions. Alarm bells are designed to meet the requirements of BS5839 Part 1. Model IST-07-10224 Well proven high reliability Plug-in power supply Interchangeable base Wide operating voltage range Zero standby current Low current consumption Loud and clear ringing tone Universal application-available in three DC voltages 6V, 12V and 24V. AC voltages available in 110V and 220V for use with most alarm systems. DECIBEL LEVELS Is highly suitable for surface or semi-concealed fixing, which, in this case, means that the base of bell can be sunk into the wall using a junction box so that the edges of the bell are only 12mm from the wall surface. AC TYPE DECIBEL RATING AT 1M (3FT) Voltage Amps 100mm (4") 150mm (6") 200mm (8") 110 0.0155 92dB 95dB 97dB 220 0.033 98dB 105dB 106dB DC TYPE DECIBEL RATING AT 1M (3FT) Voltage Amps 100mm (4") 150mm (6") 200mm (8") 24 0.05 96dB 103dB 105dB Net/Gross Weight 626/668g 888/966g 1296/1445g SIRIM TEST REPORT 83LL129 (MODEL ) MOUNTING INSTRUCTIONS The bell must be mounted with its striker pointing downwards.

IST-08-108/1 IST-08-108/2 IST-08-108/1 Pulsador con llave de Test (1x NC,NO,C) IST-08-108/2 Pulsador con llave de Test (2x NC,NO,C) Manual Call Point is suitable for open or close circuit system and is professionally designed for use in fire detection systems with central control equipment. Alternative terminals are provided for open or close circuits. When wired for open circuit operation, the circuit closes instantly when the glass is smashed. Openings are provided for 3/4" O conduit entries from top, bottom and the back. The casings are moulded from specially selected engineering plastic, which comes in 5 different colours, with high impact strength, high resistance to heat. All metal parts are made of brass and phosphor bronze to ensure life long resistance against corrosion. A high realibility micro switch is also included. Double terminal wire connectors for independent input and output connections which facilitate installations when used in looping. Provision of thread protection plugs which protect the thread of the brass inserts on the base box when conceal fixing is necessary. Incorporation of the instant test operation which is activated by a special key provided. Size Current ratings 88mm X 88mm X 55mm 12/24V DC 10A 48V DC 3A (Optional) 250V AC 10A (Optional) Net/Gross weight 160/184g Connections TERMINAL Max 2.5mm² cable AUSTRALIAN STANDARD CERTIFICATE NO. 345 OPTIONAL FEATURES Is designed to meet the requirement of BS5839 Part 2 and approved by Australian Standard AS 1603 Part 5. RANGE OF CASING COLOURS White, Yellow, Green, Red, Blue Polycarbonate transparent protection cover Super bright light emitting didode (LED) Monitoring resistor Blocking diode Switch Choices - two single pole double throw (SPDT) micro switch. six terminal provided

IST-08-11824 IST-08-11824 Pulsador con llave de Test ( NC+NO) Manual Call Point IST-08-11824 is suitable for open or close circuit system and is professionally designed for use in fire detection systems with central control equipment. Alternative terminals are provided for open or close circuits. When wired for open circuit operation, the circuit closes instantly when the glass is broken. Cable knockout seals are provided for 3/4" D conduit entries from top, bottom and the back. The casings are moulded from specially selected engineering plastic, which comes in 5 different colours, with high impact strength, high resistance to heat. All metal parts are made of brass and phosphor bronze to ensure life long resistance against corrosion. Double terminal wire connectors for independent input and output connections which facilitate installations when used in looping. Instant test operation is available through activation utilizing a special key provided. Suitable for surface or flush mounting. Size (mm) Current ratings Net/Gross weight Connections 88 x 88 x 55 12/24V DC 10A 150/176g Terminal Max 2.5mm² cable RANGE OF CASING COLOURS OPTIONAL FEATURES Polycarbonate transparent protection cover Different range of casing colours white, yellow, green, red, blue Specific languages available on facial layout upon request. Blue, Green, Red, Yellow, White

IST-08-11524 Sirenas Is a versatile, compact electronic sounder that is designed ideally for fire, security and hazard warning. This solid-state sounder offers significantly high output levels at low current consumption. The casing is designed using a high grade ABS engineering plastic that has excellent resistance to impact and heat. Featuring a red polythene removable conduit plug for easy conduit entries, is designed to work effectively with most detection systems incorporating central control equipment. It also facilitates conceal fixing with the provision of thread protection plugs that prevent damage to the brass insert thread at the base of the box.perfectly combining performance and functionality, has a protection classification of IP 54 and is designed to meet the requirements of BS5839 Part 1:1980. Functional-Inherent design offers wide operating voltage range Efficiency-Low power consumption with high output Accessible-Removable conduit plug offers easy conduit entries Versatile-Suitable for surface or flush mounting Practical Design-Provision of thread protection plugs protect brass inserts when conceal fixing is necessary Compatible-Works perfectly well with most detection systems Dimensions current voltage frequency Sound output level temperature Approximate weight Protection classification Terminal capacity 88mm x 88mm x 43mm (75mm with base) Maximum 35mA at 24V DC 24V DC 600Hz - 2.5KHz 00± 3dB at 24V DC at 1m -10 C min to +60 C max 144 g IP 54 2 x 1.5mm² conductors