VERTICAL POWER VENT KIT

Similar documents
Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

INSTALLATION INSTRUCTIONS FOR SV4.5RR4 PIPE REDUCER AND ALL ASSOCIATED SV4

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

PelletVent Multi-fuel venting system. UL 641.

TCWS54STODK FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

SERIAL # TCWS.54STOK Indoor/outdoor Fireplace Installation and Operating instructions.

DaVinci Heat Exchanger

for architects & designers

DaVinci Heat Exchanger Touch-Screen Version

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

BDM Direct Vent systems are for use with direct vent gas fired appliances.

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

INSTALLATION AND SERVICE MANUAL

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

INSTALLATION AND SERVICE MANUAL

Pellet Stove. Flex Pipe. Appliance Connector

ASX7-4-IOM-6 J

P P Gas Fireplace. P See Thru

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

SERIAL # TCWS.54STOK. FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Ventis Direct Vent. Installation Instructions

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

ASX7-5-IOM-3 J

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

MODELS: H25-NG Natural Gas H25-LP Propane FOR YOUR SAFETY

Panorama P33-10 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

TC42D - Version 2 INSTALLATION MANUAL MODEL TC42 SERIES D MODULAR DIRECT VENT FIREPLACE

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

Optima 72 USERS INSTALLATION OPERATION AND MAINTENANCE MANUAL. Gas Fired Vented Room Heater (Direct Vent) For use with natural gas or propane*

SERIAL # TC36 & TC36 ARCH INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL TC36D2 & TC36D2 ARCH INSTALLATION MANUAL. MODEL: TC36 & TC36ARCH SERIES D - Version 2 MODULAR DIRECT VENT FIREPLACE

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

INSTALLATION INSTRUCTIONS

VP Pellet Pipe. For pellet burning stoves. FEATURES

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SERIES:

Installation instructions for the T 9820 Gas Dryer

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

Panorama P36 Zero Clearance Direct Vent Gas Fireplace

X-593 SOLID FUEL HEATING QUESTIONNAIRE

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Regency Horizon HZ30E Gas Fireplace

INSTALLATION INSTRUCTIONS

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL DIRECT VENT ZERO CLEARANCE GAS FIREPLACE SERIES:

Installation Instructions

PVK-80 Power Vent - Installation Instructions -

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL DIRECT VENT ZERO CLEARANCE GAS FIREPLACE MODEL SERIES:

C44 INSTRUCTION MANUAL HEAT DISTRIBUTION / TV KIT N A T U R A L LY V E N T E D [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

DANGER. Installation and Operation Manual CARLTON-39

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.ca

INSTALLATION INSTRUCTIONS MODEL NUMBER PVH58 HORIZONTAL POWER VENT TERMINATION

DANGER. Direct Vent Gas Stove Installation and Operating Instructions. Models: OXDV30NVSB WARNING SAFETY BARRIER WARNING.

SERIAL # HELIFIRE 360 POWER VENTED/DIRECT VENT FIRE FEATURE INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION BOOKLET. 530 Direct Vent GAS FIREPLACE HEATER

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Installation and Operation Manual

MODELS: H25-NG1 Natural Gas H25-LP1 Propane FOR YOUR SAFETY

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Regency Bellavista B41XTE Gas Fireplace

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Direct Vent Heater. OMNI Listed. By Avalon

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE


SERRANO POSITIVE PRESSURE GAS FIREPLACE

Direct Vent Zero Clearance Gas Fireplace Heater Models: DV1000N/P, DV1200N/P, DV1400N/P

Installation & Maintenance Instructions

Model 530SAN Model 530SAP Direct Vent Gas Fireplace Heater (with Logs or Coals)

TCWS54D- Version 2 INSTALLATION MANUAL

TAMARRON HEAT RECIRCULATIVE GAS FIREPLACE

VENT SYSTEM COMPONENTS

Installation Instructions

EUTECTIC EC-10DV Series

USERS INSTALLATION OPERATION & MAINTENANCE

MODELS: P33-NG4 Natural Gas P33-LP4 Propane

INSTALLATION INSTRUCTIONS

Heat-N-Glo Fireplace. Installers Guide. Model: GRAND-50

DANGER. Installation and Operation Manual CARLTON-46

ZC Kit AGP Pellet Insert

St. Croix Greenfield Installation Manual

INSTRUCTION MANUAL HEAT DISTRIBUTION / TV KIT N A T U R A L LY V E N T E D [ ]

Regency Horizon HZ54 Gas Fireplace

Regency Horizon HZ42STE Gas Fireplace

Smart-Wall TV Kit - Installation & Operation Instructions -

Transcription:

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions. VERTICAL POWER VENT KIT Note: Some models require a TCVT.PVKIT For use with any TC Series D units, except for the TC54. TCVT.PVVT 3-110 FEET INSTALLATION INSTRUCTIONS Visit www.townandcountryfireplaces.com for the most recent version of this manual 200617-24 TCVT.PVVT

Table of Contents Power Vent Characteristics... 3 Dimensions... 4 Venting Length... 6 Power Vents available by Model... 6 Venting Configurations... 6 Vent Terminal Clearance... 7 Minimum clearances to combustibles Table... 7 Electrical Wiring Clearances... 9 Vent Overlap at Terminal... 10 Securing the Power Vent to the Site Fabricated Riser... 11 TCVT.PVKIT Installation... 12 Pressure Switch Hose Connection... 14 Selecting Natural Vent and Power Vent Modes... 14 Power Vent Wiring at Fireplace... 15 Power Vent Wiring... 16 Venting Components... 18 SIMPSON DURAVENT COMPONENTS... 18 SELKIRK DIRECT-TEMP... 18 SECURE VENT COMPONENTS... 18 ICC MODEL EXCELDIRECT... 18 Wiring Diagram for Series D Fireplaces... 19 Replacement Parts... 20 2 200617-24_TCVT.PVVT

Power Vent Characteristics Locate the fireplace as per the main instructions supplied. This installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. All electrical installations should be performed by a qualified electrician to the Canadian and U.S. National Electrical Codes (CSA C22.1 for Canada), (ANSI/NFPA 70 for the U.S.) and/or local electrical codes. Under no circumstances shall a rheostat be used to alter the voltage supply to this unit. This power vent is switchable from Low to High. The power setting must be selected prior to operation. For venting lengths between 3 & 25 feet, the switch must be set to Low. For venting lengths between 26 & 110 feet, the switch must be set to High. 200617-24_TCVT.PVVT 3

Dimensions Front view Side view 19 5/8 1 1/2 4 3/4 12 7/16 1 3 7/8 5 8 1/8 18 1/8 Top view Top view 19 5/8 Air Exhaust 19 5/8 Figure 1: TCVT.PVVT dimensions. 4 200617-24_TCVT.PVVT

Top view 19 3/8 Top plate Front view 19 3/8 18 1/2 10 1/2 20 Riser 20 23 Bottom plate 23 Figure 2: Riser dimensions. 200617-24_TCVT.PVVT 5

Venting Length POWER VENT 3-25 26-110 TCVT.PVVT LOW HIGH MODEL TCVT.PVVT TCVT.PVKIT REQUIRED TC30.D YES TC36.DAR TC36.D TC36.DST TCWS.38D TC42.D TCWS.54D TCWS.54DST TCWS.54STOK Power Vents available by Model (See TCVT.PVKIT installation instructions on page 12) Venting Configurations Maximum total vent length is 110 ft plus six 90-degree elbows or combination of other elbows equaling 90-degrees, with a maximum 66 foot vertical rise. Minimum total vent length is 3 ft. The vent can be installed with any combination of rise and run. Ensure vent pipe is properly supported and sealed. YES YES YES YES YES YES NO NO Vent outlet direction Supplied / site fabricated vertical chase according to local codes Vent outlet direction Site fabricated chase 66 maximum vertical rise Total maximum vent length is 110 Figure 3: TCVT.PVVT venting configurations. 6 200617-24_TCVT.PVVT

Vent Terminal Clearance Minimum clearances to combustibles Table Terminal casing: See Figure 4 Vertical vent pipe: 1.5 in. (38mm) Horizontal vent pipe: 1.5 in. (38mm) All other clearances are as per the fireplace installation instructions. Minimum clearances to the vent terminal must be maintained as shown in (Figure 4). Measure clearances to the nearest edge of termination hood. NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE DIFFERENT CLEARANCES. NOTE: For flat roof installations, check local codes for elevated platform dimensional requirements. 4 4 Note: Exhaust ports must face toward an open direction and not at another power vent or a wall within 4. There can be a minimum of 1 between power vents if their exhaust ports face away from each other. 1 Figure 4: TCVT.PVVT Air exhaust clearances. 200617-24_TCVT.PVVT 7

Note: A site fabricated riser or standoff must be built to elevate this power vent from any surface where water or snow could accumulate at the power vents base if not using supplied riser. Consult local codes to determine the height of this chase or standoff. 11 Min. 11 Min. 18 1/2 18 1/2 Figure 5: TCVT.PVVT Installation. 8 200617-24_TCVT.PVVT

Electrical Wiring Clearances 14-2 Electrical wiring must not be in contact with the vent pipe. There must be a minimum of 1 1/2 inches distance between the electrical wiring and the vent pipe 1 1/2 Min. 14-2 Electrical wiring 11 Min. 11 Min. Riser Figure 6: Electrical wiring clearance. 200617-24_TCVT.PVVT 9

Vent Overlap at Terminal Venting from fireplace to terminal must overlap enough so that the venting can be secured with screws. Tape over the joints using only the aluminum ducting tape supplied with the fireplace. 8 outer pipe 5 inner pipe Minimum 1 1/2 overlap and taped Figure 7: Power vent overlap. 10 200617-24_TCVT.PVVT

Securing the Power Vent to the Site Fabricated Riser SEALANT SEALANT Riser Figure 8: Power vent attachment. Power Vent unit attaches to site fabricated riser at 3 points along each edge of the terminal base using installer supplied hardware. Terminal base attaches to supplied riser or site fabricated riser. Use Weather Sealant between the base of the power vent terminal and plates and the riser as necessary to prevent moisture from entering the power vent unit and building (Figure 8). Flash according to local codes. 200617-24_TCVT.PVVT 11

TCVT.PVKIT Installation This kit uses either Simpson Duravent GS direct vent pipe, Secure Vent direct vent pipe, Selkirk Directtemp vent pipe or ICC Exceldirect vent pipe with a 5 inner pipe and an 8 outer pipe. For part numbers See Venting Components on page 18 of this manual. This vent can only be used as a vertically mounted roof termination. 1. Attach the vent adaptor directly to the appliance with the three screws (Figure 9) and seal outer pipe with aluminium tape provided. Note: The inner pipe does not need to be sealed. 2. Connect one of the high temperature silicone tubes to the upper pressure tap (marked LOW ) on the adaptor (Figure 9). Secure with the hose clamp provided and route the tube through any hole back to the control box. This tube will be connected to the low side of the pressure switch inside the control compartment Connect the second tube to the lower pressure tap(marked HIGH ) and route to the control box as before. Connect this tube to the remaining port on the pressure switch. Tubes may touch unit and be trimmed if required. Note: Ensure that there are no blockages in these tubes, as this will cause the control to malfunction. Secure with 3 screws and seal with aluminum tape Power Vent Adaptor. Must be installed at the unit * Upper pressure tap, marked LOW Lower pressure tap, marked HIGH * Power vent adapter not required on models TCWS.54DST and TCWS.54STOK. Figure 9: Power vent adapter. 12 200617-24_TCVT.PVVT

3. Locate the power vent termination following the clearance to combustible table, (See Minimum clearances to combustibles Table on page 7), venting configuration diagram and terminal location diagram (Figure 4 on page 7). 4. Seal and attach the power vent terminal base plate to the site fabricated chase as necessary to prevent moisture from entering the power vent unit. (Figure 5 on page 8) and flash according to local codes. 5. Run the required Simpson Duravent GS / Secure Vent / Selkirk Direct-temp or ICC Exceldirect pipe from the adaptor to the terminal assembly. Assemble as per the vent pipe manufacturer s instructions including all shields and firestops. NOTE: If this power vent is to be installed in a TC30 then it should use the full restrictor as shown in Figure 10. For all other units use the restrictor shown in Figure 11. Figure 10: Restrictor for the TC30. Figure 11: Restrictor for all other units. 200617-24_TCVT.PVVT 13

Pressure Switch Hose Connection Attach the silicone tube from the upper pressure tap on the power vent adaptor (Figure 9 on page 12) to the low port of the pressure switch. Attach the other silicone tube from the lower pressure tap to the high port of the pressure switch (Figure 12). Low side of switch High side of switch Figure 12: High and low sides of switch for Series D. Selecting Natural Vent and Power Vent Modes The NV / PV (Natural Vent / Power Vent) switch (Figure 12) on the interface board (Figure 13) is set according to which type of evacuating vent system is present. If the fireplace is vented without the assistance of a power vent, the switch should be set to NV. If using a power vent, PV must be selected. Figure 13: Vent mode selection switch. Important Note: When switching between NV and PV, both the electrical power supply to the fireplace must be turned off and the backup batteries removed to properly re-set the module. DO NOT install batteries into the wall switch while using a power vent. 14 200617-24_TCVT.PVVT

Power Vent Wiring at Fireplace Vacuum switch and hose connections Wall switch connector Inside access panel for wiring connection Power vent switch Junction box Module Interface board Outside access panel for wiring connection Figure 14: Control box. Run a 14-2 wire from the fireplace to the power vent. Connect wires to the blue and white wires in the junction box. Vent Blower wire - Blue 2 Nuetral wire - Wires Power In wire - Black Figure 15: Wiring to power vent at fireplace junction box. 200617-24_TCVT.PVVT 15

Power Vent Wiring The Power Vent assembly has an electrical connector block mounted internally. The external wiring from the main voltage/control module should be connected to this block. Follow the steps below to access this block. 1. Remove the 4 hex screws holding the top cover in place (Figure 16) and remove the cover. 2. Remove the internal cover plate (Figure 17)by removing 4 screws and slipping the plates slot around the motor wiring to remove. This exposes the electrical wiring entry point. 3. Run the electrical supply wire from the fireplace up through the bottom of the power vent and to the connector block inside the power vent assembly (Figure 18). Connect wires as shown in Figure 19 and Figure 20. Connect ground to ground screw and tighten strain relief. 4. Reposition Internal cover plate and blower cover and secure in place with previously removed screws. Figure 16: Fan access cover. Remove screws Remove screws Figure 17: Internal cover plate. 16 200617-24_TCVT.PVVT

NHElectrical wiring entry point from the bottom of the power vent unit Figure 18: Electrical wiring entry point. COMBUSTION BLOWER WHITE GTERMINAL BLACK GREEN BLOCK GREY BLACK RED BLACK WHITE Figure 19: High - Low Switch wiring. SPEED SELECTOR SWITCH Figure 20: Power vent wiring diagram. 200617-24_TCVT.PVVT 17

Venting Components SIMPSON DURAVENT COMPONENTS SECURE VENT COMPONENTS Number Description 1208...6 Pipe Length 1207...9 Pipe Length 1206...12 Pipe Length 1204...24 Pipe Length 1203...36 Pipe Length 1202...48 Pipe Length 1211...11 to 14-5/8 Pipe, Adjustable 1217... 4-10 Pipe, Adjustable 1245... 45 Elbow 1290... 90 Elbow 1240...Round Ceiling Support /Wall Thimble Cover 1241...Cathedral Ceiling Support Box 1242...Wall Firestop 1247... Wall Thimble 1263...Ceiling Firestop 1288... Wall Strap Number Description SV5L6...6 Pipe Length SV5L12...12 Pipe Length SV5L24...24 Pipe Length SV5L36...36 Pipe Length SV5L48...48 Pipe Length SV5LA... 6 Pipe, Adjustable SV5LA12... 12 Pipe, Adjustable SV5LA24... 24 Pipe, Adjustable SV5E45... Swivel 45 Elbow SV5E90... Swivel 90 Elbow SV5CSB...Adjustable decorative sq. cathedral support SV5AC...Collar for decorative sq. cathedral support SV5SU... Universal support SV5SD... Floor support SV5BM...Wall band SV5RSA... Attic radiation shield SV5RSM...Wall radiation shield SV5BF...Firestop SELKIRK DIRECT-TEMP ICC MODEL EXCELDIRECT Number Description 1605006... 6 Pipe Length 1605009... 9 Pipe Length 1605012... 12 Pipe Length 1605018... 18 Pipe Length 1605024... 24 Pipe Length 1605036... 36 Pipe Length 1605048... 48 Pipe Length 1605082... 4-10 Pipe, Adjustable 1605215...45 Elbow 1605230... 90 Elbow 1605424B... Cathedral ceiling support box (blk) 1605500...Firestop spacer 1605460B... Wall thimble (blk) 1605430... Wall support band Number Description TC-5DL6...6 Pipe Length TC-5DL1...12 Pipe Length TC-5DL2...24 Pipe Length TC-5DL4...48 Pipe Length TC-5DLF... 36 Flexible Length TC-5DLT...12 Pipe, Adjustable, Galvalume TE-5DE45...Swivel 45 Elbow, Galvalume TE-5DE90...Swivel 90 Elbow, Galvalume TM-5SS...Square Support / Radiation Shield TM-5RDS... Round Support / Radiation Shield TM-5CS... Ceiling Support / Firestop TM-OS...Offset Support TM-SR...Roof Support TM-WS...Adjustable Wall Support TM-5WT... Insulated Wall Thimble TM-5TR... Trim Ring, Black TM-5AS...Attic Radiation Shield / Firestop 18 200617-24_TCVT.PVVT

Wiring Diagram for Series D Fireplaces Figure 21: Town & Country Series D wiring diagram. 200617-24_TCVT.PVVT 19

Replacement Parts TCRP.805701 Rain Shield 1 TCRP.805704 Air Deflector 2 3 TCRP.BLOW 7-110-A TCRP.80571.1 Locking Bracket 4 TCRP.5071 SPST, ON/OFF, Black Rocker Switch 5 Figure 22: TCVT.PVVT Parts. 20 200617-24_TCVT.PVVT

TCVT.805720 Upper riser plate 805720 Riser 805721 Lower riser plate Figure 23: Chase. 200617-24_TCVT.PVVT 21

22 200617-24_TCVT.PVVT

200617-24_TCVT.PVVT 23

2017 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For Technical Support, please contact your retailer. www.townandcountryfireplaces.com 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada