Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

Similar documents
EC 5.10 FIRE PREVENTION MANAGEMENT

WHEA FSE inspections.

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

Final EC Inspection Report 03/2010

TIPS FOR BETTER JOINT COMMISSION SURVEYS

Measures (ILSM) Process

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

Standards Revisions Related to Life Safety Code Update

Procedure DESCRIPTION/OVERVIEW

Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

This policy may also be used for routine work orders that are Life Safety in nature and cannot be completed within 45-days.

UNIVERSITY OF TOLEDO

2017 Accreditation Updates

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

Are there any policies regarding outlets that contain USB ports?

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

Renovation Program. Renovation Program GENERAL

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH)

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6

UPDATE. The Healthcare Environment. George Mills, Sr. Engineer Standard Interpretation Group The Joint Commission. Copyright, The Joint Commission

Interim Life Safety Assessments and Infection Prevention Assessments

POLICY NUMBER ISSUE DATE REVISED DATE REVIEW DATE

Crosswalk of 2014 HFAP Standards against HFAP Standards Acute Care Hospital Manual

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Agency for Health Care Administration

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

LIFE SAFETY CODE MAINTENANCE MANUAL

Compliance w/ the 2012 Life Safety Code

Winnipeg Fire Department Fire Prevention Branch

2014 and 1 st Qtr Ron Neet, CPE, CEM Life Safety, EOC, & EM Manager Providence Health and Services

The University of Chicago Medical Center

The Surveyor s Perspective. Understanding How The Joint Commission Surveyors Conducts Surveys

Agency for Health Care Administration

Lauzon Life Safety Consulting

Statement of Conditions

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Standards Revisions Related to Life Safety Code Update

TJC's New 2009 Scoring System

Welcome to the Keys to a Successful Fire / Life Safety Inspection and Sustained Tenant & Building Safety

Agency for Health Care Administration

THE HEALTHCARE ENVIRONMENT UPDATE. Anne M. Guglielmo, Engineer Engineering Department The Joint Commission. Copyright, The Joint Commission

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Agency for Health Care Administration

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

4/9/2014. Life Safety Code. Nursing Facility Life Safety Code Today and Tomorrow. Kenneth Daily, LNHA.

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

2016 Joint Commission Update

Beth Israel Deaconess Medical Center BIDMC Manual

FIRE AND SAFETY PROJECT REVIEW REPORT

Agency for Health Care Administration

1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time.

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

Agency for Health Care Administration

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

Emergency Planning for Institutional Facilities

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance

Written Fire Safety Plans

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

DUKE CLINIC SITE-SPECIFIC FIRE PLAN Part II General Statement. Fire Procedures

OXNARD FIRE DEPARTMENT Fire Watch Guidelines

THE HEALTHCARE ENVIRONMENT UPDATE. George Mills, Director Engineering Department The Joint Commission. Copyright, The Joint Commission

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

California Society for Healthcare Engineering, Inc. Environment of Care, Life Safety, and Emergency Management Update 2017

FIRE SAFETY PLAN. BUILDING NAME: Pathobiology / AHL BUILDING NUMBER: 089. DATE: 15-August-10 FPO #2

System Test Report CLEAN AGENT

5/19/2011. Fire Safety Survey. Hi, we re from the Health Department and would like to speak with the Administrator and Maintenance Director

Agency for Health Care Administration

Accreditation Program: Hospital

What's New January 2017 Release

Osceola County Department of Fire Rescue and Emergency Medical Services

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

INSPECTION AND TESTING FORM

Center for Clinical Standards and Quality /Survey & Certification Group

Policies, Practices, & Procedures

Fire Protection Coffee Break Training May 2016

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

Fire & Life Safety Code Compliance. Common Safety Deficiencies and Tips for Compliance for Long Term Care and Skilled Nursing Facilities

Southaven Fire Department Fire Marshal s Office 8710 Northwest Drive Southaven, Mississippi Phone: Fax:

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012)

The Physical Environment Portal: Module 5, LS Leadership

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Agency for Health Care Administration

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

Transcription:

Documentation required by the Hospital Accreditation program Life Safety (LS) and selected Environment of Care (EC) standards is presented in the following pages. These documents will be reviewed by the Life Safety surveyor upon their arrival for the on-site survey. Other EC and LS documents may be requested by surveyors, as needed, throughout the survey. This tool is provided to organizations for use in their continuous compliance and survey readiness efforts.

LS.01.01.01 C NC NA IOU Buildings serving patients comply with NFPA 101 (2000 edition) EP4 Individual assigned to assess LSC compliance Current e-soc maintained Timely completion of PFIs Documentation of inspections and approvals made by state or local AHJs LS.01.02.01 C NC NA IOU Interim Life Safety Measures (ILSM) Alarms / sprinklers out of service 4 or more hrs in 24 hrs - Fire watch / Fire Dept. notification Addressed in Policy? Implemt. as required? Signs for alternate exits posted ILSM policy identifying when and to what extent ILSM implemented EP 4 Daily inspection of routes of egress (See also 19.7.9.2 RE: daily inspections) EP 5 Temporary but equivalent systems while system is impaired EP 6 Additional fire fighting equipment provided EP 7 Smoke tight non-combustible temporary barriers EP 8 Increased surveillance implemented EP 9 Storage and debris removal 0 Additional training on fire fighting equipment 1 Additional fire drill per shift per quarter 2 Temporary systems tested and inspected monthly 3 Additional training on bldg deficiencies, construction hazards, temp measures 4 Training for impaired structural or impaired compartment fire safety features Page 2 3/25/2016

EC.02.03.01 C NC NA IOU Hospital Manages Fire Risk - Fire Response Plan EP 9 0 The hospital has a written fire response plan. The plan describes the specific roles of staff and LIPs at and away from fire. *when and how to sound and report fire alarms, * how to contain smoke and fire *how to use a fire extinguisher, *how to evacuate to areas of refuge EC.02.03.03 C NC NA IOU Fire Drills FREQUENCY 1st QTR 2nd QTR 3rd QTR Fire drills once per shift per quarter: Health Care and Ambulatory Health Care (If available, please provide five quarters of fire drill data) Quarterly Fire drills every 12 months from date of last drill: Business Occupancies Annually 4th QTR/ Ann. When quarterly fire drills are required, at least 50% unannounced. Quarterly EP 4 EP 5 Staff participate in the drills according to the hospital's fire response plan. Critiques include fire safety equipment & building features and staff response. Page 3 3/25/2016

EC.02.03.05 C NC NA IOU Fire Protection and Suppression Testing and Inspection FREQUENCY 1st QTR/ Semi 2nd QTR 3rd QTR/ Semi 4th QTR/ Ann. Supervisory Signals-"fire pump running & fire pump failure" trouble signals Quarterly Water flow devices -- Deemed Hosptials and CAHs Water flow devices -- Non-Deemed Hospitals Tamper switches Quarterly Semiannually Semiannually Duct, heat, smoke detectors, pull boxes, elect. releasing devices Annually EP 4 Notification devices (audible & visual) Annually EP 5 Emergency services notification transmission equipment Quarterly EP 6 Fire pump(s) tested - under no flow Weekly EP 7 Water storage tank high & low level alarms Semiannually EP 8 Water storage tank low water temp alarms (cold weather only) Monthly EP 9 Sprinkler systems main drain tests on all risers Annually 0 Fire department connections inspected (Fire hose connections N/A) Quarterly 1 Fire pump(s) tested - underflow Annually 2 Standpipe flow test every 5 years 5 years 3 Kitchen suppression semi-annual testing Semiannually 4 Gaseous extinguishing systems inspected (no discharge req) Annually 5 Portable fire extinguishers inspected monthly Monthly 6 Portable fire extinguishers maintained annually Annually 7 Fire hoses hydro tested 5 yrs after install, every 3 yrs thereafter 5 yrs / 3yrs 8 Smoke & fire dampers tested (fusible links removed when applicable) 4-6 years 9 Smoke detection shutdown devices for HVAC tested Annually 0 All horizontal & vertical roller & slider doors tested Annually 5 Deemed Hospitals: Documentation includes activity name, date, frequency, contact info for person performing activity, NFPA standard, activity results Annually Page 4 3/25/2016

REVIEW EC.02.05.07 C NC NA IOU Emergency Power Systems are Maintained and Tested FREQUENCY Battery powered egress lights tested monthly - 30 seconds Monthly Battery powered egress lights tested annually - 90 minutes Annually / Missing Date Quarterly functional test of SEPSS for 5 min/class and 60% full duration of class annually Note 1: Non-SEPSS tested per manufacturer's specifications. Note 2: SEPSS for critical areas and equipment tested monthly Note 3: Class defines minimum time which SEPSS is designed to operate Qtrly/Ann. Per Mfg. Monthly EP 4 Generator load test monthly for 30 min under load (plus cool-down) Monthly EP 5 Monthly load test 30% or exhaust gas temp or annual load bank 25/50/75% Monthly/Ann. EP 6 All Transfer switches monthly/12 times per Yr. Monthly EP 7 Generator load test once every 36 months for 4 hours 36 Months EP 8 Generator 4 hour test @ at least 30% nameplate 36 Months EP 9 If generator testing fails, review contingency & implement protective measures Per occurrence 0 If load test fails retest after making repairs Per occurrence EC.02.05.09 C NC NA IOU Medical Gas and Vacuum Systems are Inspected and Tested THIS MAY BE SCORED AS CONDITIONAL OR STD Test, inspect & maintain: master panels, area alarms, automatic pressure switches, shut-off valves, flexible connectors and outlets. No prescribed frequency; recommend risk assessment if < annual. Per Policy Review med gas installation/modification/breech certification results for: As applicable cross-connection, purity and pressure Med gas supply and zone valves are accessible and clearly labeled On Bldg Tour Page 5 3/25/2016