Plant Growth Room MBDW Walk In Room

Similar documents
Plant Growth Chamber MPGR14

Reach-In. PLanT GROWTh. Reach-In

PGW36. WALk-IN PLANT GROWTH. WALk-IN

Tissue Culture Room MTCR

TCR. Features: TISSUE CULTURE

TPR. Features: TALL PLANT

SPC-56 SHORT PLANT.

TCC-34. Features: TISSUE CULTURE

SPC-7-2H SHORT PLANT.

BDR16 User Manual ENG R00

THE ULTIMATE ROOFTOP SOLUTION

STABILITY ICH. ICH Stability Tests

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

30GN FLOTRONIC II AIR-COOLED CHILLERS

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

30GT FLOTRONIC AIR-COOLED CHILLERS

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

CLIMATRON GROWTH CABINETS

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

DRYAIR Turnkey Dry Room Standards

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Vision and Skyline Semi-custom Air Handlers

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

MACH N-407 Heat Pump Air-Cooled Chiller

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

Guide Specifications for InRow Direct Expansion

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Appendix 13. Categories of Cooling and Heating systems

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Solar Walk In Cooler Robust Construction, Technology, Quality, Reliability and Repeatability for extreme Tropic Conditions

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

MAC N-407 Air-Cooled Chiller

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

PHOTOSTABILITY CHAMBERS

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

Refrigerated Incubators / Environmental Testing Chambers

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

The ultimate fresh air solution.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

CHAPTER 4. HVAC DELIVERY SYSTEMS

NFZP Variable Refrigerant Flow Guide Specification

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

- TECHNICAL NOTES SUPPLEMENT TO PROJECT WORKSHEET -

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

Heated and Refrigerated Incubators

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

500 EX Fusion Compressor Series

Air-Cooled Condensing Units with Compact Screw Compressors

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

MAC-120HE-03 Air-Cooled Chiller

20 Series INSTALLATION MANUAL ENG-R00

The following is a University standard specification and shall be reviewed and edited by the Design Professional to be project specific.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

FITOCLIMA 600 & 1200 STABILITY

INSTALLATION and OPERATION INSTRUCTIONS

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Thermal Management INDEX. Management. Thermal TM-1

VERTICAL FAN COIL UNITS

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Advance Release September 2009

Structural features: (Please refer to the accompanying draft sketch of the facility).

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

FITOCLIMA 600 & 1200 PHARMA

"ER" Series Electric Humidifier

Stability & Shelf Life

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Glass Door Merchandiser. Model RM-45-SD

WALL-MOUNT HEAT PUMPS - (60HZ)

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Glass Doors, Hinged Bottom Mounts

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

FOGEL Caribbean Corporation

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

REFRIGERATED AIR DRYERS

REFRIGERATION PRODUCTS

Glass Door Merchandiser. Model RM-49

Transcription:

Plant Growth Room

Product Overview/Applications The MBDW series walk-in chamber is based on a modular platform available in increments of 40ft2 (3.7m2). These units offer a precise chamber environment typical of research involving C4 high-light plants grown to maturity. Unique is the top-down airflow pattern which ensures consistent plant canopy temperatures throughout the chamber. Spectral aluminum on the interior walls produces unparalleled light uniformity, while the discreet lamp loft area uses a separate cooling system to mitigate heat produced by the lighting system. Lighting The standard lighting package for the MBDW series chamber generates moderate to high level light intensity and incorporates metal halide and tungsten incandescent lamps. The result is a broad based light spectrum ideally suited for plant growth. The optional lighting packages available include higher intensities as well as programmable closed-loop lighting control. Airflow Utilizing an innovative design, a top-down airflow pattern uniformly disperses conditioned air from the top of each plenum and returns the air through conditioning coils located at the bottom of the chamber area. Using an independent ventilation and conditioning system for the lamp loft helps to reduce heat transfer to the chamber area. Filtered and adjustable fresh air intake and exhaust openings enable researchers to manage exchange air to the chamber. control while ensuring quiet operation. Pressure transducers are included for monitoring the status of the refrigeration system. Alternative refrigeration methods are available depending on site-specific and/or user defined requirements. Consult the factory for heat rejection information and other refrigeration options. Experiment Protection User programmable set and forget alarms track the chamber s operation versus user-defined set points. This allows for exceptionally accurate monitoring without the need for adjustment every time the set point is redefined. Backup high/low alarms provide a further level of protection while visual and audible notification is provided when any alarm is activated. Contacts for connection to a building management system are also included. Key Product Attributes High light availability with unparalleled light uniformity Discrete lamp loft mitigates heat transfer to chamber area Top down airflow for uniform plant canopy temperatures Extended height for growth of large plants to maturity Modular design to accommodate larger sizes Product certifications/markings : CE Refrigeration Cooling for the MBDW series is provided by a self contained water-cooled condensing unit with hot gas bypass for continuous compressor operation. An electronic modulating valve provides tight temperature Performance Data Temperature Range ( C) Interior Capacity Growth Area Growth Height Exterior Dimensions (WxDxH) Light Intensities (6in. from lamp) Electrical Service Weight MBDW40-2 C to +40 C Lights Off 316 ft³ 40 ft² 95 120 x 70 x 114.25 1100 µmoles/m2/s 120-1Ø- 60Hz 2485 lb +5 C to +45 C Lights On 8920 L 3.7 m² 2415 mm 3050 x 1780 x 2900 (mm) @ 25ºC 220-1Ø- 50Hz 1127kg MBDW80-2 C to +40 C Lights Off 640 ft³ 80.9 ft² 95 120 x 132.25 x 114.25 1100 µmoles/m2/s 120-1Ø- 60Hz 3860 lb +5 C to +45 C Lights On 18075 L 7.5 m² 2415 mm 3050 x 3385 x 2900 (mm) @ 25ºC 220-1Ø- 50Hz 1751kg MBDW120-2 C to +40 C Lights Off 964 ft³ 121.7 ft² 95 120 x 196.25 x 114.25 1100 µmoles/m2/s 120-1Ø- 60Hz 5240lb +5 C to +45 C Lights On 27130 L 11.3 m² 2415 mm 3050 x 4991 x 2900 (mm) @ 25ºC 220-1Ø- 50Hz 2377kg

1.0 Control System: 7 Meditech touch screen controller MBDW40 2.0 Construction:(Note: All dimensions are nominal.) 2.1 Exterior Dimensions: 10 0 W x 5 10 D x 9 6.25 H (3050mmW x 1780mmD x 2900mmH) 2.2 Interior Dimensions: 7 9 W x 5 2 D x 7 11 H (2360mmW x 1575mmD x 2415mmH) 2.3 Growth Area: 40.0ft² (3.7m²) 2.4 Growth Capacity: 316ft³ (8,920 liters) 2.5 Growth Height: 95 (2415mm) from floor to underside of barrier. 2.6 Exterior Finish: White enamel baked on stucco 26ga. galvanized steel. 2.7 Interior Finish: White enamel baked on smooth 24ga. galvanized steel with specular aluminum to 48 (1220mm) below lamp barrier. 2.8 Cabinet Construction: Wall panels of bonded panelling construction with 4 (100mm) of foamed-in-place CFC free polyurethane insulation. 2.9 Door: One (1) infitting door 34 x 78 (865mm x 1980mm) with inside safety release latch and cam-type self-closing hinges. Door has positive closer device, thermal plastic gasket with magnetic core, and door stop. 2.10 Observation Window: Dual pane with light tight cover 14 x 14 (355mm x 355mm). 2.11 Control Panel: Left hand (right hand model optional) 2.12 Instrument Ports: Two ports, 2 (50mm) diameter with light tight cap. 3.0 Lighting: 3.1 Intensity1: 1,100 micromoles/m²/s (Higher light intensities are optional) 3.2 Programming and Control: Independent, 3 level programming of each lamp type. 3.3 Lamps: Balanced spectrum for plant growth using metal halide and tungsten incandescent lamps. 3.4 Lamp Fixture: Separated from the growth area by a transparent barrier. Barriers are hinged for easy lamp access from inside the growth area. 3.5 Lamp Heat: Removed by a dedicated water cooling coil (water or glycol supply must be 24 C (75 F) or cooler. If water is warmer, select refrigeration cooled DXLL or air-cooled ACLL option). 3.6 Ballasts: High efficiency electronic and easily accessible. 3.7 Light Meter: Quantum light meter for display and recording of light output. 4.0 Temperature Control: (Maximum design ambient temperature is +35 C) 4.1 Range: +4 C to +40 C lights OFF, 10 C to 40 C lights ON 4.2 Control2: ± 0.5 C at the control point. 4.3 Lamp Loft Control: Sensor located in lamp loft air stream, shielded from direct radiant heat. 1 Average light measurement at 39 (1000mm) from lamp barrier on a 6-inch grid, ambient temperature of 25 C. Light intensities are nominal values measured at the rated chamber supply voltage. 2 Measured by Precision Thermistors, measured without test materials or optional accessories.

4.4 Temperature Safety Limits: Primary: A programmable min and max temperature limit alarm or a limit tracking alarm that automatically follows the programmed set point. Secondary: An independent factory-set high and low temperature limit is also provided for increased assurance. An audible alarm is standard for both limits. Activation of temperature safety limit set points turns off power to the chamber. 4.5 All components utilized for temperature control such as heaters and proportional valve are energized and deenergized by solid state devices. No electro-mechanical relays or contactors. 4.6 Aspirator: Sensors are located in a self-contained, portable aspirator. This allows accurate measuring and recording by sensing at plant location. 5.0 Cooling System: 5.1 Condensing Unit: Cabinet is supplied with a water-cooled hermetically sealed condensing unit with hot gas bypass system for continuous compressor operation, extended compressor life and close temperature control. Condensing unit is located in the machine compartment, and includes a 3- way water modulating valve and hand operated shut off bypass valve. Maximum pressure drop across the condenser and water valve not to exceed 10pis (0.7 bar). 5.2 Valve: Electronic modulating valve that smoothly regulates the heating and cooling functions of the chamber. 5.3 Heat Exchanger Coil(s): Copper-tubed construction/aluminum fin. 5.4 Refrigerant: Refrigeration system is charged with CFC-free refrigerant. 5.5 Monitoring: a) Refrigeration system operation is monitored by the control system, including visual and audible alarm. b) Pressure transducers allow for real-time diagnostics for preventative maintenance & repair. 6.0 Air Flow: 6.1 Vertical: Downward from perforated diffusers surrounding each lamp canopy, located just below the lamp barrier. 6.2 Fresh Air: Filtered inlet, 50 cfm (24 liters/second). 6.3 Plenums: Dual side wall air handlers with integral heat exchangers. 7.0 Humidity Control:(Optional) 7.1 Range: No control on basic unit. (Refer to Humidity under Optional Accessories) 8.0 Carbon Dioxide Additive Control: (Optional) 8.1 Range: No control on basic unit. (Refer to Carbon Dioxide Additive Control under Optional Accessories) 9.0 Utility Requirements3: (Rating increases with some options.) 9.1 Electrical Service: : 60Hz: 50Hz (Alternative services available, consult factory) 1. Control Panel: 120/208-3Ø-60Hz-4 wire, plus ground 2. Condensing Unit: 208-230-3Ø-60Hz-3 wire, plus ground separate service 1. Control Panel: & Condensing Unit: 220/380-3Ø-50Hz-4 wire, plus ground 9.2 Drain: Floor drain must be provided within footprint of room. 10.0 Installation: (Optional) 10.1 Not Included, to be performed by customer. Installation is available upon request, please consult factory. 10.2 Should installation or technical support be required thorough Meditech Technical Service group, additional charges may apply.

OPTIONAL ACCESSORIES Plant Growth Room PROGRAMMING Can be modified according to customers requirements UPS LIGHTING Uninterrupted Power Supply Surge protection and uninterrupted power supply, on controller only, for continuous operation of the controller during power interruptions, duration of the UPS is approx. 15 minutes. (Consult factory for increased duration, if required.) HID High Intensity Discharge Lighting HUMIDITY (Based on +21 C and 50% RH ambient condition) High intensity discharge lighting using 400 watt metal halide and 400 watt high pressure sodium lamps with a light intensity of 1100 micromoles/m²/s at a distance of 1 meter from the barrier. Upon start-up, lamps experience a 5 to 10 minute warm up period before full light intensity is achieved. Please contact the factory for other lighting possibilities including electronic ballast and dimming control. DHS Dry Humidity Sensor Dry Electronic Sensor that directly measures and displays relative humidity in %RH by means of constant display (Not required if ordering additive humidity control option.) ASNH Air Mist Humidification Range: Up to 90% RH lights OFF and 80% RH lights ON, limited by a 29 C maximum dew point. Additive humidity provided by siphon fed, air assisted atomizing spray nozzles. Programming: See Control System documentation. Control: ±3% RH. System uses a dry humidity sensor to directly measure humidity in %RH (no wet sock). System requires a clean water to the following specification; ph = 7.0 ± 0.5, filtration <2 microns (0.00008 in) and resistivity between 0.5 and 1.0 Meg Ohms. Maximum water usage to maintain specified levels is 2.7 liters/hr per nozzle. System also requires oil-less, pressurized air supply of 1 CFM (0.5 liters/second) per nozzle at 50 PSI (3.5 bar) pressure. Contact factory for total consumption. BDH Bypass Dehumidification A precisely controlled volume of chamber air bypasses the heat exchanger by means of a proportionally controlled air damper. Using excess capacity in the refrigeration system, moisture is removed from the remaining air by cooling and reheating. Amp draw increases, please consult factory. Note 1. Amp draw increases, please consult factory. 2. Must be ordered with additive humidity control option.

Carbon Dioxide Additive Control CO2 Carbon Dioxide Package includes gas analyzer, control valve, and injection system. Additive Control CO2 tank not included. CONSTRUCTION GH83 Growth Height Extension Reduced growth height by 12 (305mm). Exterior height becomes 8 6.25 H (2600mm). GH112 Growth Height Extension Extended growth height by an additional 17 (430mm). Exterior height becomes 10 11.25 H (3335mm). GH143 Growth Height Extension Extended growth height by an additional 48 (406mm). Exterior height becomes 13 6.25 H (4120mm). RHC Right-Hand Control Panel Right-hand control compartment gives you the convenience and flexibility to arrange your chambers in a compact orderly fashion, back to back and end to end, or to facilitate its location in any appropriate space. HB Hose Bib Interior hose connection for watering within growth area. RECP Receptacle Wall mounted 2 amp convenience electrical receptacle within growth area (consult factory for additional amperage, if required). MAN Manual Additional Operator s Manual. (One supplied with basic unit.) REFRIGERATION DXLL Lamp Loft Cooling by DX Lamp heat removed by dedicated refrigeration cooling coil connected to chamber system (separate refrigeration condensing unit for BDW120). Independent temperature control to ensure maximum intensity from lamps. Sensor located in lamp loft air stream, shielded from direct radiant heat. ACLL Lamp Loft Cooling by AC Lamp heat removed by proportional forced ventilation to surrounding space. Cooling air filtered by high capacity pleated filter. Independent temperature control to ensure maximum intensity from lamps. Sensor located in lamp loft air stream, shielded from direct radiant heat. Recommended to minimize refrigeration system size and operating cost if suitable room ventilation is available. Contact factory for heat rejection.

Carbon Dioxide Additive Control RAC OACU Remote Outdoor Air-Cooled Condenser Outdoor Air-Cooled Condensing Unit Remote outdoor air-cooled condenser complete with all weather housing, low ambient operation controls and low noise level operation. Remote location (up to 50 [15m] combined horizontal and vertical distance) of condenser only - compressor, receiver and other refrigeration components remain in cabinet machine compartment. Order RACH for climates with ambient temperatures from +35 C to +45 C for extended periods. Electrical: 60Hz - 208-230-1Ø-60Hz-3 wire plus ground, 50Hz - 220-1Ø-50Hz-2 wire plus ground. Consult factory for either amperages or other voltages available. Notes: 1. Inter-connecting refrigeration and electrical lines are not included and must be provided by others. 2. RAC and RACH require a separate electrical service. 3. For remote location distances over 50 (15m) please consult factory. Outdoor air-cooled condensing unit containing condenser, compressor, receiver, suction accumulator, control and pressure regulating valves and electrical disconnect. The OACU comes complete with weatherized hood and crankcase heater for low ambient conditions. Inter-connecting refrigeration and electrical lines are not included and must be provided by others. OACU requires a separate electrical service. Electrical: 60Hz - 208-3Ø 60Hz-3wire plus ground, 50Hz - 400-3Ø-50Hz-3wire plus ground. Consult factory for either amperages or other voltages available. GLY Glycol Glycol heating/cooling designed to work with a central chiller refrigeration system. Includes proportional valve control. FMU Floor Mounted Where ceiling space above cabinet does not allow roof top location, unit is placed on fl oor adjacent to cabinet. All refrigeration and electrical interconnecting piping and wiring is supplied, providing condensing unit is no more than 5 feet from cabinet. ESSENTIAL SPARE PARTS ESP Essential Spare Parts Consult factory. SLS Spare Lighting Set Consult factory.

FOLLOWING ARE THE DIFFERENCES BETWEEN THE MBDW SERIES CHAMBERS MBDW80 2.1 Exterior Dimensions: 10 0 W x 11 1.25 D x 9 6.25 H (3050mmW x 3385mmD x 2900mmH) 2.2 Interior Dimensions: 7 9 W x 10 5 D x 7 11 H (2360mmW x 3180mmD x 2410mmH) 2.3 Growth Area: 80.9ft2 (7.5m2) 2.4 Growth Capacity: 640ft³ (18,075 liters) 6.2 Fresh Air: Filtered inlet 100 cfm (48 liters/second). MBDW120 2.1 Exterior Dimensions: Cabinet - 10 0 W x 16 4.5 D x 9 6.25 H (3050mmW x 4991mmD x 2900mmH) 2.2 Interior Dimensions: 7 9 W x 15 8 D x 7 11 H (2360mmW x 4790mmD x 2410mmH) 2.3 Growth Area: 121.7ft2 (11.3m2) 2.4 Growth Capacity: 964ft2 (27,130 liters) 6.2 Fresh Air: Filtered inlet 150 cfm (72 liters per second).

MBDW40 PLANT GROWTH CHAMBER NOTES: 1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4"Ø (19mmØ) CONNECTION). 2. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 3. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1" (25mm).

BDW80 PLANT GROWTH CHAMBER NOTES: 1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4"Ø (19mmØ) CONNECTION). 2. CONDENSING UNIT REQUIRES SEPERATE ELECTRICAL SERVICE (60HZ APPLICATION ONLY). 3. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 4. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1" (25mm).

BDW120 PLANT GROWTH CHAMBER NOTES: 1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4"Ø (19mmØ) CONNECTION). 2. CONDENSING UNIT REQUIRES SEPERATE ELECTRICAL SERVICE (60HZ APPLICATION ONLY). 3. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 4. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1" (25mm).