Instruction Manual WARNINGS

Similar documents
SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

SURFACE WARM CEILING HEATERS

Recessed Warm Ceiling Heaters

Commercial Fan Heater

Surface Warm Ceiling Heaters

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

AIR CURTAIN HX RECESSED RANGE

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

The CAB & DAB Air Curtains

AIR CURTAIN T SURFACE MOUNTED RANGE

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

RE-PR3-E-27 3-Phase Panel Mount 27kW

Installation, operating and servicing instructions

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

RF Programmable Room Thermostat Installation Instructions

Imperial Electric Fires

Installation, operation and Maintenance Manual

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

OPERATING AND MAINTENANCE MANUAL

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

Contact Details. Please note that some of the contact details on this PDF document may not be current.

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

WHHR Midi & Midi Lite

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

Warnings, Safety Information and Guidance

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Lo-Carbon SELV Tempra

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

HW3 Handwash Installation and Operating Instructions

Installation and Operating Manual Drying Cabinet

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Installation and User Instructions HS10U, HS15U.

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

3480/RCH SERIES INSTALLATION INSTRUCTIONS

Hand Dryer Installation & User Manual

HP RECESSED HEAT PUMP RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. For use with Mr Slim Outdoor Units

Programmable Room Thermostat Installation Instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Smoke Vent Control Panel PCB4 V4 Installation Manual

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

TECHNICAL INFORMATION Touchtronic Clothes Dryers

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

AC500T, AC1000T, AC1500T, AC2000T

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

30KW ELECTRIC FAN HEATER

NEW RANGE OF WARM AIR CURTAINS

15KW ELECTRIC FAN HEATER

INSTALLATION & USER INSTRUCTIONS

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

FLUEBOOST. flueboost 350 gas fire model

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Air curtain SMART

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

5KW ELECTRIC FAN HEATER

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

OWNERS INSTRUCTION MANUAL

PANTHER. Condensate removal pump Installation and operating guide

Original instructions AR

AIR CURTAIN COMPACT 2 SURFACE MOUNTED RANGE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Whole Room Dryer WRD, WRD/110

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

LC3000 Level Controller Installation and Maintenance Instructions

Baxi Maxflow Combi WM

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Installation and Maintenance Manual Please retain this manual for future reference.

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

CREDA STORAGE RADIATORS

Electronic Dual Cylinder Thermostat Installation Instructions

2.8KW ELECTRIC FAN HEATER

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

ESRTD2 Electronic Room Thermostat, with LCD Display

Lo-Carbon T-series Window & Roof Models

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

LC2200 Level Controller Installation and Maintenance Instructions

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

INSTALLATION AND OPERATION INSTRUCTIONS FOR

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Transcription:

Instruction Manual LARGE COMMERCIAL RECESSED AIR CURTAIN HSACR9000, 12000 & 18000 ELECTRICALLY HEATED RECESSED AIR CURTAINS WITH ENERGY SAVING CONTROLS INSTALLATION AND OPERATING MANUAL INDEX Section General information ----------------------------------------------------------- 1 Dimensions ---------------------------------------------------------------------- 2 Technical Specification -------------------------------------------------------- 3 Wiring Details ------------------------------------------------------------------- 4 Energy Saving Configuration--------------------------------------------------5 Installation Diagrams ---------------------------------------------------------- 6 Servicing & Maintenance ----------------------------------------------------- 7 Spare Parts ---------------------------------------------------------------------- 8 Fault Finding -------------------------------------------------------------------- 9 Parts replacement ------------------------------------------------------------10 User Instructions --------------------------------------------------------------11 WARNINGS 1 This appliance must only be installed by a competent person in accordance with the requirements of the Codes of Practice or the rules in force. 2 All external wiring MUST comply with the current IEE wiring regulations. 3 Warning this appliance must be earthed.

Document Index. 1 Installation Requirements 1.1 Introduction 1.2 General 1.3 Electrical Supply 1.3.1 Electronic Controller 1.4 Location 1.5 Clearance Distance 1.6 Health and Safety 1.7 Standards 2 Dimensions 2.1 Electronic Controller 2.2 Air Curtain 3 Technical Specifications 3.1 Electrical Heated 3.2 Electronic Controller 4 Wiring Diagrams 4.1 Installer Wiring 9&12kW 4.2 Installer Wiring 18kW 4.3 Factory Wiring 9&12kW 4.4 Factory Wiring 18kW 4.5 Network Wiring Electronic Controller 5 Energy Saving Configuration 5.1 Overview 5.2 Control with outdoor temperature sensor 5.3 Control with indoor temperature sensor 5.4 Optional features General Information 6 Installation Requirements 6.1 Mounting 6.2 Electrical Supply 6.3 Installation 6.4 Standard Controller 6.5 Wiring 7 Servicing & Maintenance Instructions 8 Spare Parts 8.1 General 8.2 Electronic Controller 9 Fault Finding Guide 9.1 General 9.2 Electrical Heated 9.3 Electronic Controller 10 Replacing Parts 10.1 Rotor and Motor 10.2 Electrical Element 11 User and Operating Instructions 11.1 Keypad 11.2 Manual Operation 11.3 Automatic Control 11.3.1 Auto Mode 11.3.2 Door Switch Mode 1.1 Introduction This instruction manual describes the Heatstore Large Commercial Recessed range of air curtains. Models range from 1000mm to 2000mm in length and are available in Electrically heated versions only. They are designed for discreet positioning in a suspended ceiling or bulkhead in the doorways of retail or commercial premises. Each air curtain is supplied with a electronic controller giving multi fan and heat settings via a simple key pad which can be mounted up to 50m from the air curtain. Optional BMS time control, external thermostats and door interlocks can be installed. The Electronic programmer shown above allows the user to control either a single air curtain, or a network of up to 6 air curtains with the same settings, and provides the following functions:- 2 - Heat On Off or Auto via optional thermostat - Off or Low, Medium and High Fan Speeds For further details please refer to section 10.2 1.2 General All installations must be in accordance with the regulations in force in the country of use. fig.1. Electronic program keypad

These instructions must be handed to the user on completion of the installation. Installers and service engineers must be able to demonstrate competence and be suitably qualified in accordance with the regulations in force in the country of use. To ensure continued and safe operation it is recommended that the appliance is serviced annually. The manufacturer, offers a maintenance service. Details are available on request. The air curtain outlet grille and case air inlet slots must not be obstructed during use. 1.3 Electrical Supply. For full electrical loadings, please refer to the individual technical data sheets within this manual. It is recommended that the electrical supply to the base unit in the air curtain is via an appropriate switched isolator in accordance with the regulations in force in the country of use and must be via a fused isolator having a contact separation of greater than 3mm in all poles. BMS control, time switches, room thermostats and door interlocks can be installed at the discretion and responsibility of the installer. All units must be wired in accordance with I.E.E regulations for the Electrical Equipment of Buildings and the installer should ensure that a suitable isolating switch is connected in the mains supply. Warning For safety reasons a good earth connection must ALWAYS be made to the heater and control box. 1.3.1 Electronic controller Electrically heated supply is either 230V 1 phase (6kW options) or 415V 3 phase (9 to 24kW), Neutral and Earth. Max cable inlet size is 4mm² or 6mm² (refer to individual technical specification) Remote unit is wired to the base unit via a Belden 9174 cable (or direct equiv). 1.4 Location All units should be installed horizontally directly over the door opening. It is recommended that the air curtain is installed on the inside of the building, within the ceiling void or roof space. Care must be taken to allow complete free air movement into the inlet grilles of the unit to ensure correct working operation of the air curtain. The discharge opening should be as close to the top of the door as possible and to cover the entire door width. Units can be mounted adjacent to each other to cover the full door opening across wider entrances. 1.5 Clearance distances It is recommended that a minimum clearance of 100mm is allowed around the case sizes detailed below. The clearance allows for cable entry and prevents combustible surfaces overheating. The minimum mounting height (floor to grille) is 1.8m. The recommended mounting height is 3m for standard and 4m for high capacity models. 1.6 Health and Safety Sole liability rests with the installer to ensure that all site safety procedures are adhered to during installation. Sole liability rests with the installer to ensure that protective safety wear such as hand, eye, ear and head protection is used during installation of the product. Do not rest anything especially ladders against the product. 1.7 Standards Units conform to the European electrical standard BS EN 60335-2-30 and to the following European CE directives- 73/23/EEC - amended 98/68/EEC low voltage; 89/336/EEC electromagnetic compatibility. 3

2. Dimensions. 2.1 Air Curtain DIM 'C' DIM 'F' DIM 'G' DIM 'B' DIM 'D' DIM 'E' DIM 'A' DIM 'J' DIM 'H' Dimensional detail (mm) Size HSACR9000 HSACR12000 HSACR18000 A 253 B 1220 1520 2020 C 1182 1482 1982 D 454 E 395 F 1205 1505 2005 G 1242 1542 2095 H 160 J 200 4

2.2 Electronic program keypad 87.0 60.3crs 13.35 60.3crs 43.5 Fig.2. Surface mount Cable Entries SELECT 7.35 75.0 60.3crs 7.35 60.3crs Fig.3. optional flush mount Earthing point Cable Entries 3. Technical Specification. 3.1 Program Controller General Data Sensor input Protection Fan Output Connection Supply Dimensions Mounting positions Temperature Display Push buttons NTC 2 x slow blow fuse for the protection of the heater switching devices. 3 off Relay for High, Medium and Low Fan setting 3A max 240Vac Screw terminals 4 for supply, 6 for heater output, 4 for fan output, 2 for BMS (time) control, 2 for sensor input, 2 for external thermal trip, 2 for external door switch. 230V 1Ph or 415 3Ph dependent on model type. Program panel 88mm(L) x 88mm(W) max. Program panel fixing centres 60.3mm 5 to 50 ºC operating; -20 to 65 ºC storage Three 7-segment LCD red for parameter display 3 positive feedback tactile push buttons 5

3.2 HSACR9000 HSACR9000 HSACR9000 General Data Maximum height M 3.0 Door width M 1.0 1.5 2.0 Heat medium Electric heated Heat setting kw 4.5 / 9 6 / 12 9 / 18 Fan type / dia Crossflow / 100mm Fan settings 3 Switching type AC-ACR-PANEL Weight kg 28.0 34.0 49.0 Electrical Data Supply voltage 415V 3ph 50Hz Total load kw 9.1 12.1 18.1 A/pha 12.6 16.8 25.2 Motor power W 60 90 Max Starting current* amps 0.96 1.5 Max Running current* amps 0.65 0.75 External fuse size amps A/pha 16 20 32 Programmer keypad pt. no. AC-ACR-PANEL Program keypad control wiring Belden 9174 (or similar) Cable terminal size 4.0mm² Max 6.0mm² Max Bottom of base unit. Separate din rail Mains terminal block position Terminals N; L1; L2 & L3 E: N; L1; L2 & L3 Control terminal block position Right side of base unit terminals +12V, DATA & Air Data Air volume Low speed m³/h 1164 1475 2013 Medium speed m³/h 1405 1780 2432 High speed m³/h 1646 2085 2851 Air velocity Low @ 0M m/s 4.3 5.4 Medium @ 0M m/s 5.6 6.9 High @ 0M m/s 7.0 8.4 High @ 1M m/s 3.5 4.2 High @ 2M m/s 1.6 2.1 High @ 3M m/s 0.8 1.0 Delta T Low speed C 26 25 21 Medium speed C 23 22 20 High speed C 20 19 19 Noise level @ 1M Low speed dba 59 in free field Medium speed dba 62 High speed dba 64 Dims Data Length mm 1182 1482 1982 Depth (width) mm 395 Total height* mm 200 Outlet length mm 1125 1425 1945 Outlet depth (width) mm 85 Grille height mm 40 Mounting bracket centres length mm 1220 1520 2020 Side to 1 st bracket centre mm 18 Mounting bracket centres height mm Flush with top of unit Top to 1 st bracket centre mm Flush with top of unit * Motor current only at high speed 6

4.2 Installer Wiring - Electrically Heated 9 & 12kW THREE PHASE ONLY The program panel is connected to the base unit via a set of 3 way connectors marked "+12V, DATA and ". Interconnecting wiring is via Belden 8132 or equivalent cable as shown. Max length 50m. It is recommended that this control cable is run separately within its own trunking to avoid external interference. Door switch to be volt free and wired normally closed contacts to terminals D1, D2. (Contacts broken when door is open). External switch (ie BMS enable) to be volt free and wired via normally open contacts to terminals B1, B2. DATA +12V Optional internal/external sensor to be wired to terminals S1, S2. Door Switch PROGRAM PANEL (rear view shown) screen Sensor S1 S2 DATA D1 +12V D2 B1 BASE UNIT (located in air curtain) B2 External Switch J1 T1 T2 F1 N N F3 F2 F2 F1 AC2-T1 L1 AC1-T1 AC2-T2 L2 AC1-T2 AC2-T3 L3 AC1-T3 Remove link J1 for external time switch Chassis Earth 415V 50Hz Mains Supply Pcb Terminal Description N L1 L2 L3 +12V DATA (s) D1, D2 Protection B1, B2 S1, S2 External circuit breaker with the appropriate rating should be installed for the protection Pcb Fuses F1 of the installation. F2 7 Neutral 3 phase supply 3 phase supply 3 phase supply Supply to remote unit Data to remote unit 0v Terminal option door contact option BMS switch option internal/external Sensor Rating (A) T2A (slow blow) T3.15A (slow blow) Cable 4mm² max 4mm² max 4mm² max 4mm² max Cable 1.0mm2 max

4.3 Installer Wiring - Electrically Heated 18kW THREE PHASE ONLY The program panel is connected to the base unit via a set of 3 way connectors marked "+12V, DATA and ". Interconnecting wiring is via Belden 8132 or equivalent cable as shown. Max length 50m. It is recommended that this control cable is run separately within its own trunking to avoid external interference. Door switch to be volt free and wired normally closed contacts to terminals D1, D2. (Contacts broken when door is open). External switch (ie BMS enable) to be volt free and wired via normally open contacts to terminals B1, B2. DATA +12V Optional internal/external sensor to be wired to terminals S1, S2. Door Switch Sensor PROGRAM PANEL (rear view shown) screen S1 S2 DATA D1 +12V D2 External Switch J1 B1 B2 T1 T2 BASE UNIT (located in air curtain) F1 Remove link J1 for external time switch Chassis Earth AC1-T3 L3 AC2-T3 AC1-T2 L2 AC2-T2 AC1-T1 L1 AC2-T1 F1 F2 F3 N N F2 Contractors Terminal Protection 415V 50Hz Mains Supply External circuit breaker with the appropriate rating should be installed for the protection of the installation. Terminal Description Cable N Neutral 6mm² max L1 3 phase supply 6mm² max L2 3 phase supply 6mm² max L3 3 phase supply 6mm² max Pcb Terminal Description Cable +12V Supply to remote unit DATA Data to remote unit (s) 0v Terminal Cable 1.0mm 2 D1, D2 Option door contact max B1, B2 Option BMS switch S1, S2 Option internal/external sensor Pcb Fuses Rating (A) F1 T2A (slow blow) F2 T3.15A (slow blow) 8

4.5 Factory Wiring - Electrically heated 9 & 12kW THREE PHASE ONLY SENSOR DOOR BMS THERMAL DATA +12V Overheat AC1-T3 L3 AC2-T3 AC1-T2 L2 AC2-T2 AC1-T1 L1 AC2-T1 F1 F2 F3 N N Elements Fan Motor Pcb Terminal Description L1 Heater Elements phase 1 L2 Heater Elements phase 2 L3 Heater Elements phase 3 N Neutral to fan F1 Fan - low speed F2 Fan - medium speed F3 Fan - high speed T1 Thermal Overheat trip T2 Thermal Overheat trip J1 Factory BMS link The element output is connected to the right and left side of each terminal block marked "AC1-T1, AC2-T1, AC1-T2, AC2-T2, AC1-T3 and AC2-T3 The fan output is connected to a 4 way connector marked "N, F1, F2 and F3". The thermal trip is connected to a 2 way connector marked "T1" & T2 9

4.6 Factory Wiring - Electrically heated 18kW THREE PHASE ONLY J1 S1 S2 D1 D2 B1 B2 T1 T2 DATA +12V Overheat AC1-T3 L3 AC2-T3 AC1-T2 L2 AC2-T2 AC1-T1 L1 AC2-T1 F1 F2 F3 N N T1 L1 T2 L2 Elements T3 A2 AC1 L3 A1 T1 L1 T2 L2 Elements T3 A2 AC2 L3 A1 Fan Motor Contractors Terminal E N L3L2 The element outputs are connected to contactors "AC1 and AC2 on terminals T1, T2 and T3. The fan output is connected to a 4 way connector marked "N, F1, F2 and F3". The thermal trip is connected to a 2 way connector marked "T1" & T2 L1 Pcb Terminal Description AC1/2-T1 Heater Elements phase 1 AC1/2-T2 Heater Elements phase 2 AC1/2-T3 Heater Elements phase 3 T1 Thermal Overheat trip T2 Thermal Overheat trip N Neutral to fan F1 Fan - low speed F2 Fan - medium speed F3 Fan - high speed J1 Factory BMS link 10

4.7 Network Wiring - Electronic controller PROGRAM PANEL (rear view shown) DATA +12V Screw terminals screen BASE UNIT (located in air curtain 1) BASE UNIT (located in air curtain 2) DATA +12V DATA +12V DATA +12V Networking This diagram refers only to the data cable wiring of 2 or more networked air curtains. (maximum 6 air curtains per control panel). For mains wiring refer to section 4 of this manual installer wiring details. The program panel is connected to the base unit in the first air curtain via a set of 3 way connector marked "+12V, DATA and ". Each subsequent air curtain is linked to it s corresponding terminal. Interconnecting wiring is via Belden cable 8132 or equivalent as shown. Max length 50m. (Total length of cable used between program panel and last air curtain in network). It is recommended that this control cable is run separately within its own trunking to avoid external interference. BASE UNIT (located in air curtain 3) 3 core screened cable, To subsequent air curtains (maximum of 6) 11

5. Energy Saving Configuration. 5.1 Introduction. Shops, warehouses and factories are all subject to the problems caused by frequently opened doors. The open door not only causes a draft but greatly increases energy loss and, therefore, the running cost of the building. Screenzone units offer a costeffective, energy efficient solution to these problems by reducing heat loss. The installation of a Screenzone air curtain with energy saving controls provides a barrier of air that keeps the conditioned or warm air inside the building. The energy saving control unit when run under automatic control reduces both the power consumption and energy cost. The key benefits of the energy saving controls are: Simple installation wiring connections are direct to the controller, no intermediary terminal blocks are required. Easy programming the user sets two temperatures and three fan speeds enabling the air curtain to vary the required heat output depending on the selected temperatures. In conjunction with a door switch the controller can be set to change the fan speed when the door opens. Compatible with Building Management Systems The air temperature sensor can be mounted outside or inside to enable temperature control. No specialist commissioning required. Reduced payback period of your investment thanks to the energy saving generated. Cabling from the air curtain to the program panel requires only 3 core cable. One control unit can control up to six air curtains. A centralised control unit can be mounted up to 50m from the air curtain. 5.2 Control with outdoor temperature sensor. This type of temperature control is suitable for open door trade or frequently used doorways in large areas where heat from the heater would not affect the indoor ambient temperature. The controller can be set to vary the heat output depending on the outside temperature. This type of control shouldn t be used in small areas, between two sets of doors or small shops. In this configuration the heater is running on a preset speed and variable heat output depending on two user selected temperatures t1 and t2. (range 0 to 30 degrees C) If the outside temperature around the sensor falls below the selected t2 temperature the heater will be working on 100% heat output. If the temperature is above the selected t2 temperature but below t1 selected temperature the heater will be 12 working on 50% heat output. If the outside temperature is above the user selected t1 temperature there is no heat output but the fan is running on a selected speed. For example: t1-16 deg C t2-7 deg C Temperature below 7 - full heat Temperature above 7 but below 16 - half heat Temperature above 16 - no heat, cold blow only 5.3 Control with indoor temperature sensor. This type of temperature control is suitable when the heater is used in small areas, between two sets of doors or in small shops where running the heater on full heat setting for a longer period will bring the room temperature to a very high level. With a temperature sensor mounted inside the building the controller can be set to vary the heat output depending on the inside ambient temperature. In this configuration the heater is running on a preset speed and variable heat output depending on two user selected temperatures t1 and t2. (range 0 to 30 degrees C) If the ambient temperature around the sensor falls below the selected t2 temperature the heater will be working on 100% heat output. If the temperature is above the selected t2 temperature but below the t1 selected temperature the heater will be working on 50% heat output. If the ambient temperature around the sensor is above the user selected t1 temperature there is no heat output but the fan is running on a selected speed. For example: t1-20 deg C t2-15 deg C Temperature below 15 - full heat Temperature above 15 but below 20 - half heat Temperature above 20 - no heat, cold blow only 5.4 Optional features Both types of control can be used in conjunction with a door switch which will change the fan speed as selected by the user. In the case where the door switch is not used a standard one pole switch can be used to change the fan speed in auto mode. The heater can be also connected to a Building management system or 24h 7day timer to run the heater in fully automatic mode. If the heater is not connected to a Building management system or timer the available terminals can be connected to a standard one pole switch (light switch) to turn the heater off or on.

6. Installation Details. 6.1 Mounting All units should be installed horizontally directly over the door opening. It is recommended that the air curtain is installed on the inside of the building, within the open room space against a wall or ceiling. Care must be taken to allow complete free air movement into the inlet grilles of the unit to ensure correct working operation of the air curtain. The discharge opening should be as close to the top of the door as possible and to cover the entire door width. Units can be mounted adjacent to each other to cover the full door opening across wider entrances. 6.3 Installation. It is the sole responsibility of the installer to ensure that the points of attachment to the building are sound. Consultation with the consultant/architect or owner of the building is recommended to ensure that a sound, mechanically stable installation is achieved. All attachments must be capable of supporting the weight of the product detailed in Section 3. Step 1 Before fitting or wiring the air curtain, ensure casing faces as below and see general installation guidance notes. 6.2 Electrical Supply. These units are suitable for connection to a 415 Volt, 50Hz 3 phase and neutral supply for Electrically heated 18-24kW models or 230/240 Volt 50 Hz single phase supply for Electrically heated 6kW models. Electrically heated models consume 6kW at 230 volts and 9kW, 12kW & 18kW at 415 Volts when switched to the full heat position depending on their model and capacity size. The appliance shall be connected to the supply via an appropriate switched fused double pole isolator having a contact separation of greater than 3mm. Test for correct operation and refit the cover. For connection to the mains supply it will be necessary to open the hinged lid from the unit. The base unit is located on a base plate. It will be necessary to connect the mains supply and the lead from the remote key pad prior to refitting the cover. Wire in accordance to diagrams in section 4.1 to 4.3 Step 2 ENSURE AIR OUTLET LOUVRES ARE NEAREST TO DOOR APPERTURE. Using a pozidrive screwdriver remove the M5 screws at the side of the grille. For safety reasons, a sound earth connection must always be made to the unit before it is put to use. The unit should be wired in accordance with IEE Regulations for the Electrical Equipment of Buildings. 13

Step 3 Access to the inside of the air curtain grille can be made. Open the grille. The grille is hinged to prevent the inner frame from dropping. Step 6 Either drop rods or catenary wire (available from manufacturer) can be used to fasten the air curtain to the ceiling support structure. Note When using drop rods the casing mounting brackets are slotted and the mounting plates provided must be used on assembly. Step 4 The grille assembly can now be removed from the case to allow fitting of the product in the ceiling recess. Remove the screws from the outer frame to the top of the product case. Step 5 Attachment of the air curtain to the ceiling structure is by means of the two brackets attached to the side of the air curtain. The brackets may be removed to assist in passing the air curtain through the recess then reattached when in-situ. Step 7 The height between the ceiling face and the face of the air curtain case needs to be adjusted to circa 40mm to enable the grille assembly to fit flush with the ceiling. Adjust accordingly. 14

After fitting the product in the ceiling recess and adjusting the height to ensure that the grille sits flush to the ceiling (when re-fitted) take the grille assembly and refit using the screws removed during Step 5. 6.5 Installation wiring With case removed, connect the electrical supply and program panel interconnecting wiring to the appropriate terminals on the controller base unit (See relevant wiring diagram section 4) 6.4 Installation details - Electronic programmer The Electronic base unit is pre-installed inside the air curtain. All the external electrical connections are via screw terminals onto this base unit. The program keypad is installed on a separate facia plate and connected to a surface mounted back box in a suitable location. Please see fig 5. 87.0 60.3crs 13.35 43.5 Cable Entries Fig. 4. Surface mount location holes. Alternatively, the program panel can be flush wall mounted with the addition of a suitable conduit box MK part number 861 ZIC or equivalent. Fig. 5. Alternative conduit box The distance between the base unit and the program panel can be up to 50m maximum if Belden 8132 or equivalent cable is used. 15

7. Servicing & Maintenance. ALWAYS ENSURE THAT THE MAIN EXTERNAL ELECTRICITY SUPPLY IS SWITCHED OFF BEFORE COMMENCING ANY MAINTENANCE ON THIS HEATER. Step 2 Access to the inside of the air curtain grille can be made. To obtain the best results from the heater, it is essential to avoid the accumulation of dust and dirt within the unit on the air inlet and discharge grilles. For this reason regular cleaning is necessary, paying particular attention to the removal of dirt build up on the rotor blades. Cleaning of the fan is best carried out with a soft brush. A single drop of light oil should be applied to the motor bearing from time to time. The product should be serviced annually. Servicing shall be undertaken by a competent person. Step 1 Using a pozidrive screwdriver remove the M5 screws at the side of the grille. Open the grille. The grille is hinged to prevent the inner frame from dropping Step 3 With a soft brush clean away any dust from the motor and elements. Check all connections and components for soundness or signs of deterioration and replace as necessary. Re-assemble and test. 16

8. Spare parts 8.1 General Description HSACR9000 HSACR12000 HSACR18000 Motor 100003 100012 Contactor n/a 900078 Rotor Left Hand 100001 100006 100010 Rotor Right Hand 100002 100007 100011 Thermal cut out 900001 Element assembly Rating 9kW 12kW 18kW Part No 100004 100008 100013 Length 1.0m 1.5m 2.0m 8.2 Electronic controller Due to the nature of its construction, it is not advisable to repair damaged electronic components on either the base unit or Electronic program panel Program Keypad AC-ACR-PANEL Base Unit AC-ACR-PCB Outside Air Sensor SC-OS 17

9. Fault Finding. 9.1 General If the air curtain does not operate after running through the detail provided in Section 6, then a suitably competent service engineer should be called to identify the nature of the fault. Note The manufacturer operates a service function from the address provided in these instructions. All Air Curtains are fitted with fuse protection and motor thermal protection. Other faults in relation to the element, motor and wiring should be identified using conventional fault finding techniques. In the event that electrical components are replaced, please ensure that electrical safety checks in accordance with the regulations in force in the country of use are undertaken. 9.2 Electrically heated units For the service engineer, please note that there is a thermal cut-out incorporated in the air curtain which needs to be manually reset. The cut-out is located near to the mains terminal block. Re-setting the thermal cut-out may help to identify the nature of the fault however we do not recommend re-set without a thorough investigation into why the cut-out operated. fig.7 Electronic controller 1: Polarity: Use a multimeter to check correct polarity between all three cores i.e. that +12V goes to +12V, DATA goes to DATA, and to. 2: Continuity: Use a multimeter to check continuity between each end of all three cores. 3: Short circuit: Use a multimeter to check that there are no short circuits between any of the three cores. N.B. This test should be done with both ends of the cable disconnected to avoid false readings. 4: Plugs: a) Check that the correct length of insulation has been stripped from each core. b) Check the tightness of the cables in the plugs. fig.6. Thermal cut-out 9.3 Electronic Controller If the air curtain goes into thermal trip (overheat) the Electronic panel keypad displays an ERR code. Refer to air curtain instructions to remedy. The electronic control base unit is protected from any short circuit on the air sensor or heatsink sensor as the short circuit will cause the temperature to go high and trigger over temperature alarm. 18

10. Parts replacement. 10.1 Electrical element replacement. Step 1 Using a pozidrive screwdriver remove the M5 screws at the side of the grille. Access to the inside of the air curtain grille can be made. Open the grille. The grille is hinged to prevent the inner frame from dropping. Step 2 Disconnect element wires and if necessary remove cut-off plate fixing screws. 10.2 Rotor and motor replacement. Step 1 Using a pozidrive screwdriver remove the M5 screws at the side of the grille. Access to the inside of the air curtain grille can be made. Open the grille. The grille is hinged to prevent the inner frame from dropping. Step 2 Remove fastening holding rotor support bracket Step 3 Remove element top fixing screws. Locate and remove element fixing screws by inserting a screwdriver through the hole indicated below. Step 3 Move rotor support bracket towards outside of case. Step 4 Lift out element cartridge, replace as required. Step 4 Disengage rotor bearing. 19

Step 5 Disconnect rotor from motor shaft. Step 6 Ensure on replacement of rotor that the flat on the rotor bearing aligns with the flat on the motor shaft. Step 7 Disconnect motor facing clips (2) using a large screwdriver and exerting downward pressure. A sharp tap can help in releasing the clip. Disconnect the wires from the motor to the mains terminal rail. motor. Replace motor in reverse order. Carefully close the grille and refit the fixing screw. Test product as shown in the User Instructions. 20

11. User Instructions. 11.1 Keypad fig.8. Electronic Programmer The The The button will allow you to navigate. button will allow you to increase the setting. button will allow you to decrease the setting. 11.2 Manual operation On first power up, the display panel will have the following default settings: F. 0 (no fan - heater in stand-by, waiting for external signal to operate ie door switch ) H. 0 (no heat) Note: Subsequent power ups will retain any entered settings in the display panel internal memory. Press the or buttons to toggle between the F (Fan), H (Heat) and On/Off Parameters. Prefix F denotes the FAN SPEED. This can be either 1: slow ; 2: medium or 3: fast speed. 0 setting denotes the unit is in stand-by mode. This setting can be used in conjunction with a door switch or movement sensor connected across terminals D1 and D2. When the switch is activated the heater is running on a preprogrammed speed and heat setting. See 11.3.3 To alter the current speed, press the value will start flashing. button. The Press the or buttons to increase/decrease the desired setting. Press the button to confirm the new setting. If not pressed within 7 seconds will return to the original display. Prefix H denotes the HEAT setting. This can be either 1: low heat; or 2: high heat. 0 setting denotes the unit is set at fan only. To alter the current setting, press the value will start flashing. button. The Press the or buttons to increase/decrease the desired setting. Press the button to confirm new setting. If not pressed within 7 seconds will return to the original display. 21

The next parameter will either turn the unit On or Off. To turn the unit Off, press the flashing. button. On will start Press the Press the button. Off will start flashing. button to confirm new setting. To turn the unit On, press the flashing. button. Off will start Press the button to alter to On. Press the button to confirm new setting. A delay of 7 seconds will return to the F Fan parameter. To switch the heater On or Off automatically the terminals B1 and B2 can be used to connect the heater to a Building management system or 24h 7day timer. If the heater is not connected to a Building management system or timer a standard one pole manual switch (light switch) can be used. The heater may be operated in manual mode however you will not be able to benefit from the energy saving features which are available in auto mode. 11.3 Automatic Control 11.3.1 Auto Mode The controller can be set to automatic control only when used in conjunction with a temperature sensor. In this configuration the heater is running on a preset fan speed (1: slow ; 2: medium or 3: fast speed. 0 setting denotes the unit is in stand-by mode) selected in manual mode before entering auto mode setting and variable heat output depending on t1 and t2, two user selected temperatures. (Range: 0-30 degrees). Auto mode can be used in conjunction with a door switch or movement sensor connected across terminals D1 and D2. When the switch is activated the heater is running on a pre-programmed speed and heat setting. See 11.3.3 To access the auto mode setting, first ensure that the display is in the (H) HEAT parameter. Press and hold the b button for 5 seconds. 22

11.3.2 Auto Mode Settings After entering auto mode settings the set point t1 will appear on the display. The first number is indicating setting point t1 and the second number selected t1 temperature. If the air temperature around the temperature sensor is above this value the heater is working on 0% heat output. (Range: 0-30 degrees). To alter the setting, press the button then the or buttons to increase/decrease the value. Press the button to confirm new value and use the button to move to the next setting. (A delay of 7 seconds will return to the original display.) If you have previously pressed the button the set point t2 will appear on the display. The first number is indicating setting point t2 and the second number selected t2 temperature. If the air temperature around the temperature sensor falls below the t2 value, the heater is working on 100% heat output. If the temperature is above this value but is below set point t1, then the heater is working on 50% heat output. (Range: 0-30 degrees) To alter the setting, press the button then the or buttons to increase/decrease the value. Press the button to confirm new value and use the button to move to the next setting. If you have previously pressed the A.OF will appear. button, setting This setting will enable the Auto Mode. (Range: On/Off) To alter the setting, press the button then the or buttons to toggle between the A.OF and A.On modes. A.On enables the air curtain to run in automatic mode. A.OF enables the air curtain to run at fan speed and heat setting previously selected in manual mode. When the display shows A.OF it is possible to access the auto mode parameters by using or buttons. To return from auto mode settings to manual operating mode setting press and hold the button for 5 seconds. 23

11.3.3 Door Switch Mode The door switch can be used in both manual and auto mode. The controller can be set to a preset fan speed when the door opens. This function can only when used in conjunction with a door switch. In the case where the door switch is not used a standard one pole switch can be used to change the fan speed in auto mode. To access the engineers setting, first ensure that the display is in the (F) FAN parameter. Press and hold the b button for 5 seconds. Setting d will appear. The air curtain operates as normal under the program of the Fan and Heat settings. As the door opens the air curtain changes state to the settings preset in this mode. As the door closes, the air curtain returns to normal. (Range: 1: slow ; 2: medium or 3: fast speed. 0 setting denotes the fan is not running.) To alter the setting, press the button then the or buttons to increase/decrease the desired setting. Press the button to confirm new setting. A delay of 2 seconds will return to the original display. HEATSTORE Avon Riverside, Victoria Road Avonmouth, Bristol BS11 9DB Tel: 0117 9235375 Fax: 0117 9235374 Document reference number: 41000924 Iss 02 24