Energy-saving operation

Similar documents
Air Conditioner CONTENTS

Create an Environment that Benefits Your Business

AIR CONDITIONING REVERSE-CYCLE INVERTER

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

2 &3-4 Head Multi System

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

AIR CONDITIONING REVERSE-CYCLE INVERTER

Pure Efficiency Meets Healthy Living NEW 2013

JUNE & 3-4 Head Multi System

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Light commercial range. Passion at work

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Heat Pump Air Conditioning Systems

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

TABLE OF CONTENTS. Air Conditioner CS-F18DTE5 CU-J18DBE5

Hi-spec Design model. Photo : LT series

Ducted Air Conditioning

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

(Non-Inverter & Inverter) R410A

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Inverter Ducted Air Conditioners

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

Technology that works fast. Inverter Ducted Systems

Ducted Air Conditioning

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AIR CONDITIONING AERO SERIES REVERSE-CYCLE INVERTER

Inverter console UFV system. Compact design and personalised air flow selection

Split System Air Conditioning

Inventor of the Inverter Digital Inverter System

What do I need for my bedroom?

DC Inverter Smart VRF Products(R410A)

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Inverter Ducted Air Conditioners

INVERTER DUCTED SYSTEMS

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Just feel well. 2017/2018 Air conditioning

Q Series. Inverter Split Systems

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

Ducted inverter reverse cycle air conditioning

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

HI-WALL SPLIT SYSTEMS

3 rd Generation of VRV. The professional solution for your professional project

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Wall Split System Air Conditioning

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

MULTI SPLIT. Control several indoor units with one outdoor unit. Build the optimum system you desire.

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Why Choose Mitsubishi Electric?

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

The New Generation of Heat Pumps

G Series Inverter Split Systems

FREE MULTI SYSTEM Z R32 GAS. NEW FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit R32 NEW REFRIGERANT GAS

Air Conditioner CONTENTS CS-E18EKU CU-E18EKU CS-E21EKU CU-E21EKU. Order No: MAC C1

Residential and Light Commercial Ductless Systems Catalog

Mitsubishi System Technologies:

Deluxe High Wall/ Floor Console Air Conditioner

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

AIR CONDITIONERS LINE-UP

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Ultimate VRF System R410A, 50Hz

Panasonic RAC/PAC Training

Product Brochure N Series

AIR CONDITIONING AERO SERIES ECONAVI REVERSE-CYCLE INVERTER

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Monozone/Multizone (NH5, QH5) Summit (YH5) Bigflow (G4, GH4) Technical Catalogue

AIR CONDITIONING ECONAVI REVERSE-CYCLE INVERTER

Product Brochure N Series. Hi Wall Split System

DUCTLESS SPLIT SYSTEMS

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Innovative air conditioning

LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises

Transcription:

DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and high-efficient operation and reduces the running cost. Hyper Wave Inverter The Panasonic group s experiences and actual results in the development of inverters are realised in the control. This control of the inverter demonstrates the maximum compressor torque. The FS series quickly warms the room up to the set temperature and maintains a comfortable condition, whilst ensuring energy efficiency and savings. Our conventional inverter Hyper Wave Inverter Power is wasted. 1 The current waveform deviates from the motor voltage waveform, so power is wasted. The current waveform closely matches the motor voltage waveform, so power consumption is reduced. Compare this to a car rounding a corner. 3 Power is wasted when the car swings off course. When the car stays right on course, there's no power loss. High-Efficiency Compressor 2 Hyper Wave Inverter DC Inverter Compressor New Large Diagonal Air Flow Fan Using a powerful neodymium magnet for a motor allowed us to make the mot compact. The winding rotor motor of less magnetic field distortion attains higher efficiency. 4

and energy-saving operation Advanced Turbo-Fan Efficiency The cassette indoor unit is equipped with a newly-developed turbo fan; the new shape produces low noise and high air flow rate. In addition, the DC fan motor is able to give complete control, this is almost twice as efficient as a conventional motor and enables comfortable and energy saving operation. The Advanced Air Path Design Key to Efficiency. Newly Designed Turbo Fan newly developed three-dimensional blade shape 1 The stabilises the air flow. Both air inlet and outlet are improved. layout of the indoor heat exchanger 2 Optimising and the fan enables the increase in the fan diameter. Space-saving design Space-Saving Outdoor Unit The improvement of the outdoor unit fan makes it possible to install the outdoor unit into a smaller space where the conventional model cannot be installed. Without sacrificing quietness, higher efficiency is also attained. More freedom in installation contributes to easy piping and facilitates installation. It will cut the installation cost. The Sophisticated Air Path Design Key to Compact Size. Top view These three improvements minimise the air resistance. 1 Outdoor unit 32 cm (Air discharge side) Only 30 cm needed More than 50 cm needed (conventional) New large diagonal air flow fan The newly designed fan blades reduce the frontal discharge distance. 2 Improved front grille opening shape 3 Improved front grille grid shape 5

Pursuing the Perfect Design In Air Q Comfort in every detail Panasonic s FS Series includes the knowledge of carefully designing for comfort. Careful consideration has been given to both air flow and air quality. A wired remote control is also available, which is equipped with a high-performance timer to program the operation mode to meet the requirements of each user. For cassette models Multi Comfort Air Control Newly developed control technology offers the various selection of fine air blowing angle. Select from the 3-pattern auto swings so as to not be exposed to the air directly (total 50-degree swing width). 0 0 10 0 10 10 30 30 40 30 40 50 40 50 60 70 AUTO 1 70 50 60 70 AUTO 2 50 60 70 AUTO 3 40 70 Can be operated with the wireless remote control. For all models Odour Wash Odour Wash reduces any unpleasant odours produced from the air conditioner s heat exchanger. Dual-system of odour control 6 Odour Removing Odour Clear# ONE PUSH 3 SEC. PUSH When the air from the outlet smells musty. Moisture in the heat exchanger washes away odours. When odours are strong, and before and after the air conditioning season. The heat exchanger heats up to clear odours. Can be operated with the wireless remote control. # Applicable Models: Inverter Models Only

Quality, Airflow, and Convenience For all models Weekly timer settings (each day of the week) are available to control the air conditioner. Max. 6 settings/day and 42 settings/week can be executed. The setting temperature can be also programmed for optimal comfort. Weekly Timer Set like this for these uses Shop with regular holidays The number of persons varies depending on time zones. Example: Closed Saturday afternoon and all day Sunday. Example: Set a lower temperature at lunch time when a lot of persons may visit. Example: To prevent forgetting to switch OFF weekdays Mon-Fri On 9:00, Off 18:00 Everyday Mon-Fri Sat On 9:00, Off 12:00 On 12:00 23 C Sun Not set On 14:00 28 C The timer can have different settings for every day of the week. Not to forget to switch OFF Off :00 In this case, the temperature can be set at the same time. The timer can be set for simple shut-off operation. How to set 1 2 Select the day. Enter the time. *Simple Timer Mode Using the 24-hour On/Off timer, the operation of On/Off can be set at a same time everyday. For all models For all models Economy Mode Ventilation An approximate %* energy-saving operation is attained. The air conditioner judges the stable condition and moderately shifts the set temperature in 0.5-degree steps to control the energy-saving operation. (Max. 2 degrees) When an external device such as a ventilator is connected to the indoor unit, the ON/OFF switch for the ventilator can be controlled by the wired remote control. Either link-ventilation or independent-ventilation is selectable. Temperature Setting temperature (digital connection) Heating 2ºC ON 2ºC Setting temperature Cooling 30min ON 30min 30min 2 hours 30min Time * During operating in the cooling mode at the remote control set temperature of 25º under the cooling standard temperature conditions. Can be operated with the wireless remote control. Ventilators are not included in the product line. Optional printed circuit board (Interface Adapter for External Signals: CZ-TA30P*) is needed. 7

Ceiling - Suspended Selectable Remote Control * Customer needs to choose either wired or wireless. Wired Remote Control Wireless Remote Control Easier Maintenance and Cleaning Versatile Functions Anti-Mould Long Life Air Filter Auto Restart Function Auto Fan Mode 3-Direction Pipe Lead-Out The refrigerant piping can be lead out in one of three directions (right, rear-right and top-right), and the drain pipe direction can be selected from four directions. Top-right Anti-Mould Long Life Air Filter Rear-right * For optimum comfort, we recommend cleaning the air filter every 1.5 months. Right (Wired Remote Controller only) 24-Hour On/Off Real Setting Timer Odour Wash Economy Mode Low Ambient Cooling Operation *See page 11 for details. Auto Changeover Function Dry Mode Function Wide Air Discharge, Comfortable Control Wide-Angle Airflow 100 Degrees Horizontal Weekly Timer Hot Start Control Self-Diagnostic Function Auto Swing Louvre Wall-to-Wall Comfort Even in Large Rooms Top View Side View Manual louvre Swinging louvre (automatic) Specifications (min-max) Ceiling Models (min-max) * For pipe lengths greater than 30 metres, add refrigerant R410A at 50 grams/metre. 10

Outdoor Units 6.3kW - 7.1kW 10.0kW - 14.0kW Flexible Installation in Smaller Spaces A variety of improvements has reduced installation time and space. Space-Saving Outdoor Unit Flexible 4-Way Piping By improving the fan, we were able to make the outdoor unit small enough to fit in spaces too tight for conventional units. Piping can be routed in any of four directions. Top view Outdoor unit 32cm (Air discharge side) Only 30cm needed Centralised Drain Method The drain outlets can be gathered into a single drain pipe even when multiple outdoor units are installed to a wall. More than 50cm needed (conventional) 50m Long Piping Max. 50m # Piping can be extended up to 30 metres without additional gas charging, and up to 50 metres with additional gas charging. By giving you more flexibility in positioning the outdoor unit, this gives you a wider range of installation options. Pipe length Max. 30m # Height difference Allowable Pipe Length # Additional gas is required. 6.3kW - 7.1kW 10.0kW 12.5kW - 14.0kW Max. Length # 50 m 50 m 50 m Max. Chargeless Length 30 m 30 m 30 m Max. Height Difference # 30 m*1 m*2 30 m*1 m*2 30 m*1 m*2 *1 When installing the outdoor unit at a higher position than the indoor unit. *2 When installing the outdoor unit at a lower position than the indoor unit. Drain Pipe Side-by-Side Continuous Installation Even outdoor units with different capacities can be installed side by side in an efficient, orderly layout. To make this possible, we have positioned the service port in the front and given all models the same depth. Low Ambient Cooling Operation The unit can be used for cooling even when the outdoor temperature is extremely low. This is ideal for locations that require cooling even in winter. Quiet, Efficient Design A host of silencing technologies achieve super-quiet operation. We've also improved operating efficiency and reduced energy consumption. Regular cooling conditions: -5 C* to 43 C (outdoor temperature) * However, cooling operation at -15 C is possible in non-residential computer rooms, etc., where the temperature is not less than 21 C and humidity is not more than 45%. Regular heating conditions: - C to 24 C (outdoor temperature) Noise-Suppressing Winglet Fan 11

OUTDOOR UNITS Inverter: 140 100 500 Air intake side Space for piping, wiring 100 and maintenance Air outlet side 6 140 100 500 Air intake side Space for 0 piping, wiring and maintenance 300 140 355 6 3 140 10.0kW - 14.0kW Air outlet side 40 (Inverter) 40.5 (Non-Inverter) 900 900 300 6.3kW - 7.1kW CU-L34DBE5/CU-L43DBE5/ CU-L50DBE5/CU-L50DBE8 355 CU-L24DBE5/CU-L28DBE5 3 Inverter: 40 3-ø27 Conduit hole 1340 (Inverter) 1170 (NonInverter) Right piping hole (Knock out hole) Front piping hole (Knock out hole) 24 300 24 795 Front piping hole (Knock out hole) 12 3-ø27 Conduit hole Right piping hole (Knock out hole)

CASSETTE TYPE CS-F24DB4E5/CS-F28DB4E5 CS-F34DB4E5/CS-F43DB4E5/CS-F50DB4E5 880 795 fresh air inlet position 60 840 880 700 840 pipe(gas side) 80 333 108 25 300 or less 500 or more 68.5 63 Required space for installation drain port pipe(liquid side) 500 or more Beam 500 or more Beam Obstacles 950 950 Obstacles 2500-3000 500 or more 1000 256 188 113 291 108 25 drain port pipe(liquid side) Required space for installation 346 60 300 or less 68.5 63 2500-3000 346 60 91 80 840 1000 pipe(gas side) When raising the drain head above the unit When raising the drain head above the unit drain port down-slope (1/50~1/100) drain port down-slope (1/50~1/100) 950 indoor unit Wireless remote control Photo receiver unit position 750mm or less 950 Wireless remote control Photo receiver unit position indoor unit 750mm or less 840 113 151 298 880 700 fresh air inlet position 60 188 880 795 CEILING TYPE CS-F34DTE5/CS-F43DTE5/CS-F50DTE5 Required space for installation 13

Wired Remote Control Wireless Remote Control CZ-RD513C CZ-RL513B (For Cassette Type) CZ-RL513T (For Ceiling Type) (For Cassette Type and Ceiling Type) Wireless Control Receiver (For Cassette Type) Wireless Control Receiver (For Ceiling Type) * A wired remote control is included with hide-away types. Group Control by a Single Remote Control Separate Control by Twin Remote Controls Common Control by Both Wired and Wireless Remote Controls Receptor unit Indoor units Indoor units Remote-side remote control Remote-side remote control All indoor units operate in the same mode. Local-side remote control (either wired or wireless) Wired remote control Each indoor unit can be operated by either of the two remote controls. Apart from the timer setting time, the displays for the two remote controls are identical. The last button pressed has priority (The main or slave attribute is set with the remote control). The System of Model Numbers Wireless remote control The last button pressed has priority (using either wired or wireless remote controls). CS - F 28 D B4 E 5 CU - L 28 D B E 5 1 2 1 Model Type 3 4 5 4 Type CS: Split Type (Indoor Unit) CU: Split Type (Outdoor Unit) Split Type: Indoor/Outdoor Unit B4 : Cassette (4-Way) D1 : Ducted (High Static Pressure Models) T : Ceiling B : Outdoor Unit for Cassette, Ceiling and Ducted Indoor Unit 2 Function Indoor Unit F: Can be used with Inverter, Non-Inverter Models Outdoor Unit L: Inverter Models 3 Capacity Value = Capacity (Btu/h) x 1/1000 e.g. 28,000 Btu/h x 1/1000 28 5 Power Supply 5: 50Hz (Single Phase) 8: 50Hz (3-Phase) SPECIFICATIONS Outdoor Unit Sound Pressure Level is 1 metre from front & 1.5 metres from base of unit.. Guaranteed Operating Range Rating Conditions Inside air temperature Outside air temperature Cooling Heating Cooling Heating 27 C DB/19 C WB C DB Minimum -5 C DB 24 C DB 35 C DB 7 C DB/6 C WB Maximum 43 C DB - C DB Outdoor Where specified energy efficiency values, EER (PL), part load, complies with AS/NZS3823.. 15