Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

Similar documents
C1050ES Tankless Water Heater

C1210ES Tankless Water Heater

940ES Tankless Water Heater

940ES Tankless Water Heater

C1210ESC Tankless Water Heater

940ESO Tankless Water Heater

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Tankless Condensing High Efficiency Water Heaters

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Concentric Vent / Air Intake Kit Stainless Steel

Residential Gas Tankless Water Heater

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Residential/Commercial Gas Condensing Tankless Models

Commercial Tankless Rack System

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Commercial Tankless Rack System

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

Commercial Tankless Rack System

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Greentherm 9800 SE 160/199 SEC 199

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Bosch Greentherm Series

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

TL-Pro 175C/199C INDOOR MODEL. TL-Pro 175/199 C - Natural Gas TL-Pro 175/199 C- Propane (LP Gas) Installation and Operation instructions

INFINITI K APPLICATIONS MANUAL. Indoor Residential and Tankless Water Heaters. Warning: Follow each appliance's instructions precisely.

C 950 / 1050 ES C 950 / 1050 ES - Natural Gas / C 950 / 1050 ES - Liquefied Petroleum (LP) Gas

GB Condensing Gas Boiler

RTG 199 HE INDOOR MODEL. RTG 199 HEN - Natural Gas RTG 199 HEX - Propane (LP Gas) Installation and Operation instructions

iq1001, Gen II Submittal Data

iq251, Gen II Submittal Data

C 1050 ES - Natural Gas C 1050 ES - Liquefied Petroleum (LP) Gas

Date: Project #: Engineer: Prepared By: Bid Date:

GB Condensing Gas Boiler

C 1210 ES/ESC - Natural Gas C 1210 ES/ESC - Liquefied Petroleum (LP) Gas

GB Condensing Gas Boiler

The WCGH High Efficiency Commercial Water Heater with Storage Tank

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Utica Boilers MAC Submittal

Automatic Circulating Water Heaters

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

On-Demand Water Heater Installation Manual and Owner s Guide

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

C 1210 ES/ESC C 1210 ES/ESC - Natural Gas / C 1210 ES/ESC - Liquefied Petroleum (LP) Gas

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

G515/7 Cast Iron Boiler

i200, Gen II i250, Gen II Submittal Data

Installation Manual CONDENSING TANKLESS GAS WATER HEATER DANGER WARNING CAUTION CAUTION

Greentherm 9800 SEO 160/199 SECO 199 FOR OUTDOOR INSTALLATIONS ONLY

Tankless Water Heaters

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

G615/11 Cast Iron Boiler

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE BOILERS

10 : 1 Turndown Ratio

TRONIC 6000C WH17 & WH27 Electric Tankless Water Heaters

Installation and Operation Instructions Manual

WATER-TUBE POOL HEATERS

Suggested Specifications Prestige Excellence 110

Commercial Gas Water Heaters

MECHANICAL VENTING VERSATILITY

DIVISION FINNED WATER-TUBE BOILERS

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Installation Manual REVOLUTION WATER HEATER. Model VRP-150 VRP-199 VRS-150 VRS-199

WATER-TUBE POOL HEATERS

Installation and Operation Instructions Manual

Commercial Applications

DIVISION FINNED WATER-TUBE BOILERS

On-Demand Water Heater Installation Manual and Owner s Guide

MODEL GWH 2400 ES NG and GWH 2400 ES LP - INDOOR MODEL

DIVISION FINNED WATER-TUBE WATER HEATERS

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

FINNED WATER-TUBE POOL HEATERS

iq751/iq1001/iq1501 Specifications (Floor-standing units)

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

On-Demand Water Heater Installation Manual and Owner s Guide

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

MODEL GWH 2700 ES NG and GWH 2700 ES LP - INDOOR MODEL

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

T H2 DV / T H2 OS. On Demand Condensing Water Heater Installation Manual and Owner s Guide WARNING WARNING. Model T H2 DV and T H2 OS

Raptor 320HB & 399HB Submittal Sheet

Project Name: Location: Engineer: Contractor: I. GENERAL

TANKLESS WATER HEATER HEATING SOLUTIONS

RG7D 1-Stage Heat Series

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

G315/6 Cast Iron Boiler

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

Transcription:

Engineering Submittal Sheet Product Overview & Certifications Engineering Specifications The system shall consist of gas tankless water heater model Greentherm T9800 SE 199 as manufactured by Bosch Thermotechnology. Water Heater shall be CSA/ANSI Z21.10.3 listed, and operate with a 100% thermal efficiency. The Greentherm 9800 SE 199 water Heater shall have an input of 199,000 BTU/Hr with natural or propane fuel. Water Heater shall have Low NOx emissions and be 2016 SCAQMD NOx certified to rule 1146.2. CONSTRUCTION Water Heater shall be gas fired, condensing tank less design with a segmented power burner and modulating gas valve. Burner shall be capable of 22:1 turndown of firing, without loss of combustion efficiency. Primary heat exchanger/combustion chamber shall incorporate a multi pass copper tube and fin design. Secondary condensing heat exchanger shall incorporate a multi-pass stainless steel heat exchanger with bank tubes for lower water pressure drop. Heat exchangers shall be rated for maximum working pressure not less than 150 psig. The Water Heater shall be equipped with an active bypass valve to achieve water temperature stability of less than +/- 2 of. On the cold water inlet connection the Water Heater shall be equipped with an externally accessible in-line water filter. The Water Heater s external control panel shall consist of a high resolution LCD display with capacitance touch keys. The internal control board shall be field replaceable. The combustion safeguard/flame monitoring system shall utilize spark ignition and a rectification type flame sensor. The control panel hardware shall support wireless remote communications if the wireless module is installed. The controls shall include extensive self-diagnostic capabilities that incorporate a minimum of 38 separate fault codes. 1 of 8 reserves the right to make changes without notice due

Engineering Specifications The Water Heater shall come equipped with power cord and shall operate on 120V/1/60Hz electrical service. INSTALLATION All aspects of installation of Water Heater system shall be in strict accordance with manufacturer s instructions. Materials shall conform to all manufacturer s recommendations including a manufacturer listed vent system. Venting options shall include 2 and 3 Flex PP, Rigid PP, Concentric PP, Common PP Vent, PVC (sch40), PVC-DWV, CPVC (sch40), and ABS-DWV (sch40). Venting length will be limited to 60 when using 2 pipe and 280 when using 3 pipe. Water Heater will include a barometric pressure sensor that will be used to determine the altitude of installation. Water Heater will have top mounted water connections and bottom mounted flush ports. Water Heater shall include an ASME approved temperature/ pressure relief valve with a setting of 150 psig. Water Heater shall require a minimum gas pressure of 5.0 W.C. of natural gas and 8 W.C. for propane. MODE OF OPERATION Water Heater shall include integral factory wired operating controls to control all operation and energy input. The outlet water temperature shall be controlled using the integrated digital display with a field adjustment of 100 F to 140 F. Water Heater shall be capable of maintaining the outlet temperature within an accuracy of ±2 F*. This shall be accomplished by modulation of firing rate and the use of the active bypass valve. MULTI UNIT CASCADES The Water Heater shall be capable to cascade configurations with up to 24 Water Heaters plumbed in parallel when using the Cascading Kit. This Cascading Kit accessory shall stage Water Heaters based on demand activating or deactivating other Water Heaters as needed. WARRANTY The heat exchangers shall carry a 15-year limited warranty against leakage due to defects in materials or workmanship in a residential, non-direct recirculation system, subject to the manufacturer s warranty terms and conditions and water quality requirements. All other parts and components provided by Bosch shall carry a 5 year limited warranty against defects in materials or workmanship subject to the terms and conditions of the manufacturer s warranty. The Water Heater shall carry a 1-year limited warranty for Service labor cost against defects in workmanship subject to the terms and conditions of the manufacturer s warranty. Performance Data Unit Value Maximum flow rate at a 35 F (19.4 C) rise GPM (l/min) 11.2 (42.4) Maximum flow rate at a 45 F (25 C) rise GPM (l/min) 8.7 (32.9) Maximum flow rate at a 55 F (30.6 C) rise GPM (l/min) 7.2 (27.5) Maximum flow rate at a 75 F (41.7 C) rise GPM (l/min) 5.2 (19.7) Maximum flow rate at a 90 F (50 C) rise GPM (l/min) 4.4 (16.6) Maximum gas input¹ BTU/hr (kw) 199,000 (58.3) Minimum input BTU/hr (kw) 9,000 (2.6) Maximum output BTU/hr (kw) 197,010 (57.7) Thermal efficiency (Efficiency in %) % > 99% ¹)Input rating is based on sea level operation and need not be changed for operation up to 2000 ft (610 m) elevation. For operation at elevations above 2000 ft (610 m), input rating is automatically reduced at the rate of 4 percent (US) or 10 percent (Canada) for each 1000 ft (305 m) above sea level. 2 of 8 reserves the right to make changes without notice due

Operational Data Unit Value Temperature Control² Selection range F ( C) 100-120³) (38-49) Default temperature F ( C) 120 (49) Temperature stability4) F ( C) ± 2 (± 1) Gas Requirement Gas connection inches ¾ Max. Inlet gas pressure NG / LP Inch W.C. 3.5" - 10.5" / 8" - 13" Water Top hot water connection NPT inches ¾" Top cold water connection NPT inches ¾" Minimum water flow6) GPM (l/min) 0.45 (1.7) Maximum water pressure PSI (bar) 150 (10.3) Minimum recommended water pressure PSI (bar) 18 (1.2) Minimum well pressure PSI 30 Water valve material Polymer (PPS) (Polypropylene Combustion CO level ppm 250 (measured) CO2 level (set from factory) % see installation manual Weight Net weight pounds (kg) 77.5 (35.15) Gross weight pounds (kg) 83.67 (37.95) Electrical Voltage V AC 120 Frequency Hz 60 Amperage (Idle) ma 40 Amperage (operation) A 2.7 Water protection7) IP X4D Venting Venting category IV Approved vent or combustion air pipe material - United States Approved vent or combustion air pipe material - Canada PP flexible/concentric/rigid PVC sched. 40, PVC-DWV, CPVC sched. 40, ABS-DWV sched. 40 CSA or ULC certified only (ULCS636) ²) With constant flow. ³) Can be reprogrammed to achieve 140 F (60 C). ⁴) Requirements: Steady flows, single unit installations, up to 140 F (60 C). ⁵) To measure Gas Pressure, see Measuring Gas Pressure, chapter 4.13, page 36. ⁶) Activation varies with inlet water temperatures. ⁷) Protection against water drops. 3 of 8 reserves the right to make changes without notice due

Dimensions and Connections 27 / / 2 2 4 of 8 reserves the right to make changes without notice due

Water Heater Pressure Drop Curve Pressure Drop (psi) 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 Water Flow (GPM) 6720813634-37.1V 138.6 134.0 129.4 124.7 120.1 115.5 110.9 106.3 101.6 97.0 92.4 87.8 83.2 78.5 73.9 69.3 64.7 60.1 55.4 50.8 46.2 41.6 37.0 32.3 27.7 23.1 18.5 13.9 9.2 4.6 0 Feet of Head Clearances Description Unit Recommended Minimum clearance* TOP (A) Inch 12 FRONT (B) Inch 1 BACK Inch 0 SIDES Inch 1 FLOOR (C) Inch 12 * For servicing access, a 2ft clearance is recommended to the front cover. 5 of 8 reserves the right to make changes without notice due

Required direct vent terminal clearances (twin pipe / concentric penetration) Clearance Data Item Description Canadian installations ¹ ) U.S. installations ² ) A Clearance above grade, veranda, porch, deck or balcony 12 in. (30cm) 12 in. (30cm) B Clearance to window or door that may be opened 36 in. (91cm) 12 in. (30cm) below or to side of opening; 12 in. (30cm) above opening. C Clearance to permanently closed window * * D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft (61cm) from the center line of the terminal. * * E Clearance to unventilated soffit * * F Clearance to outside corner * * G Clearance to inside corner * * H Clearance to each side of center line extended above meter/regulator assembly 36 in. (91cm) within a height 15 ft (4.6m) above the meter/ regulator assembly I Clearance to service regulator vent outlet 36 in. (91cm) * J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance. 36 in. (91cm) * 12 in. (30cm) K Clearance to a mechanical air supply inlet 6 feet (1.83m) 36 in. (91cm) above if within 10 ft (3m) horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft (2.13m)³) * M Clearance under veranda, porch deck or balcony 12 in. (30cm) ⁴) * 1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code 3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. 4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. * For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2.20, or; b) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. 6 of 8 reserves the right to make changes without notice due

Required other than direct vent terminal clearances (single pipe penetration) Clearance Data Item Description Canadian installations ¹ ) U.S. installations ² ) A Clearance above grade, veranda, porch, deck or balcony. 12 in. (30cm) 12 in. (30cm) B Clearance to window or door that may be opened. 36 in. (91cm) 48 in. (1.2 m) below or to side of opening; 12 in. (30cm) above opening) C Clearance to permanently closed window * * D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) from the center line of the terminal * * E Clearance to unventilated soffit * * F Clearance to outside corner * * G Clearance to inside corner * * H Clearance to each side of center line extended above meter/regulator assembly 36 in. (91cm) within a height 15 ft (4.6m) above the meter/ regulator assembly I Clearance to service regulator vent outlet 36 in. (91cm) * J Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 36 in. (91cm) * 48 in. (1.2m) below or to side of opening; 1 ft (300mm) above opening K Clearance to mechanical air supply inlet 6 ft (1.83 m) 36 in. (91cm) above if within 10 ft (3m) horizontally L Clearance above paved sidewalk or paved driveway located on public property 7 ft (2.13m) 3) * M Clearance under veranda, porch deck or balcony 12 in (30cm) 4) * 1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code 3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. 4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. * For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2.20, or; b) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. 7 of 8 reserves the right to make changes without notice due

Tankless Components T9800 SE 199 Components [1] Inlet water filter [2] Air fan [3] Control unit [4] Gas manifold [5] Burner [6] Heat exchanger [7] Condensing unit [8] Main water valve [9] By-pass pipe [10] HE drain [11] Power cord [12] Gas connection [13] Condensate drain [14] HE drain [15] Gas valve [16] Condensate trap [17] By-pass water valve [18] Ionization sensor [19] Ignition electrodes [20] PRV connection DISCLAIMER Specifications subject to change without notice. All dimensions shown on these engineering submittal sheets are for reference only and should not be used for field installation purposes. Please refer to current product installation manuals for detailed installation instructions and dimensions. 8 of 8 reserves the right to make changes without notice due