Automations and ACLinks. Technical Support Engineering Rosslare Security NA For more information please see

Similar documents
SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

NextGen Home Security. Quick Reference Guide

D3D Wi-Fi GSM Smart Alarm System -User Manual

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Condominium Security Management System

Paradox Integration Module Settings Guide

Version 1.03 January-2002 USER S MANUAL

Input Type: 42: Medical: This is a 24 Hr type input it will activate the external sounder and report a CID event 100.

Challenger Version 8 Programming Relays.

Application Version: 2.0 and above Date Written: 03/09/2010. Copyrights , Global Security Devices, All Rights Reserved

Integration Guide AXIS Camera Station and AXIS A8004-VE

Summit 3208GLD USER MANUAL. Electronics Line

RE6100 Series Helix Security and Automation Platform

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Simon XTi Quick Operation Guide

Using Your. Security System With LED Keypad S5030, S5031, S5032

2000 Series. Program Entry Guide. Control Panels

U ser's Guide PC6010

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Access Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

Digiplex LED Keypads User s Manual

Alarms Updated 03/26/2018

HARDWIRED CONTROL PANELS

PROGRAMMING PROCEDURES (Table 3)

Challenger Series Users Manual

Table of Contents. Appendix A Special Characters 31

IQ PANEL USER GUIDE SMARTHOME.

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Security System. User Guide for the LED Command Center

DS7446KP. User Guide. Keypad

abode Web app Functionality

C2 Compact Range Installation & Programming Manual

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

ELT-KLED EliteSuite LED Keypad Installation Manual

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Master User Guide Premier Elite Series

Advisor Advanced User Guide

XT30/XT50 U S E R G U I D E

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

AXI LED USER MANUAL (REV. 1.0)

DESCRIPTION OF KEYPAD (Access module with segments)

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

GV2 Series Control Panels

IDoorBell Fon DP68 Quick Installation Guide

BURGLAR ALARM PANEL BS-468

Lonix Access Control Operation & Maintenance Manual

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

XR500/XR100. User s Guide

User Reference Guide. Ref: LCP500-L /15 Rev. C

HILLS Series LED Code Pad User Manual

XTL/XTLN/XTLN-WiFi USER GUIDE

DCS2000 DEMENTIA CARE SYSTEM USER GUIDE. For Software Version 1.2 1

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

Contents. Glossary

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

First Alert 1200C Installer Notes M. Leuck

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Silencing an Alarm All/Perimeter or Home/Sleep/Away System What to do when a trouble tone is sounding

Wireless Alarm System Extended User Guide. Alarm Panel Time 10:09 c

XRSuper6. User s Guide

XTL Series USER GUIDE

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Intelligent Security & Fire Ltd

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Lyric Gateway. User Reference Guide. Ref: LCP300-L/LCP300-LC /16 Rev A

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

Underfloor Heating Programmable Thermostat

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

3D_ISS. Integrated Software System. User Guide Manual

Synergis Master Controller 2.2 Integration Guide for Assa Abloy IP Locks

System User Guide. XR Series Control Panel

VISTA-50P VISTA-50PUL

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

Safewatch Pro 3000 System Manual

WELCOME TO CÔR HOME AUTOMATION HOMEOWNER S USER GUIDE. This Homeowner s User Guide will provide information to customize your Smarter Home.

S6 Titan Security System. Wi-Fi and 3G GSM

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

IDS816 User Manual H Issued January 2009

SYSTEM USER GUIDE X R S E R I E S C O N T R O L P A N E L

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

Introduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055).

What to do when a trouble tone is sounding

Midco SmartHOME TM Subscriber Portal User Guide. Jamaica 6.0

SECURIT 700L PLUS ENGINEERING MANUAL

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

EURO 46 V10 User Manual

Midco SmartHOME Quick Start Guide. Learn how to protect the things that matter most using this Midco SmartHOME instruction guide.

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

M800, M800iD Plus, M1000 and M3000. User's Guide

Transcription:

Automations and ACLinks Technical Support Engineering Rosslare Security NA For more information please see www.axtraxng.com

AC Links are used to create automations and perform custom operations on access control panel. The simplest and most common use is to unlock a door on a schedule. AC Links may also be used to augment the logic in a panel, to make use of unused inputs or redirect inputs to perform a different function, i.e. use the 1A input for a motion detector request to exit. AC Links also provide a method for triggering relays to drive external alarms for events such as door forced open or held open. AC Links may be used to trigger an action from a reader, a door bell is a common application.

Automatic Door Operation

The first example is for an Automatic Door Operation to open a door on a schedule. For the schedule I am using a time zone active from 8:00 AM until 4:00 PM Monday through Friday. The steps to create this time zone are shown on the next 4 slides. While this schedule is very simple, more complicated schedules may be created with up to 16 time segments per day, 7 days per week plus holidays.

Expand Timing by clicking on the + to the left. Select Time Zone then the Green + to create a new time zone. Left click and hold the mouse button at the beginning of the time period (8:00) and drag the end (16:00). Change the name to Weekdays.

Right click in the dark blue area and select create. It should turn light blue with the red bar as shown.

Repeat the previous 2 steps for each day. Click OK to save the new Time Zone.

Right click in the time segment to edit, a properties box will open as shown. Change the start or finish time as required and click OK to save. Click OK to close the properties window.

The next step is creating the AC Link. An Automatic Operation AC Link must be created for each door that is to be opened. They may not be created using output groups. Only one Automatic Operation AC Link may be used at a time for an output. In other words, you may not have two different time zones controlling the same door, you must build all of the time segments into one time zone required for the door. AC Links When creating an AC Link for an exterior door it is advisable to enable First Person Delay. This is a per door property that is accessed on the door properties window, it prevents the door from opening on an automatic operation until a user has entered a valid code(pin or card) after the start of the time zone. This prevents an outside door from unlocking in the event of bad weather such as snow days at a school.

Expand AC Networks, Network 1, Panels 1 as shown and select AC Links. Click the green + to create a new AC Link Select the following; Source Type Output Source Output 1 Event Automatic Operation Time Zone Weekdays OK to save and close

This slide shows how to enable the First Person delay on a door. Expand AC Networks, Network 1, Panel 1 and highlight Doors. Move to the right in the table view and highlight the door you want to edit. Click the edit icon at the top, this opens the door properties window. Check the box labeled First person delay on automatic unlock Click OK to save and exit.

Door Alarms

This example is an AC Link to generate an alarm or alert when a door is forced open or held open. The door forced and door held alarm functions are built into the panel firmware by default, they both require the use of a door monitor switch. The door forced alarm will be triggered any time a door is opened without a valid credential or REX input to open the door, if a motion detector is used to open a door it must either be connected through the panel or provide a shunt across the door monitor switch to prevent the alarm from triggering. The door held open alarm is triggered when a door is held open longer than the door held open timer which is set in the door properties, by default 30 seconds. In the first example of door forced open, the alarm will be used to trigger the built in siren located in the panel and generate a popup on the PC. (Popup only works when AxtraxNG client is open.) In the second example of door held open the alarm will trigger only a chime tone from the sounder in the panel.

To enable the door alarms, expand AC Networks, Network 1, Panel 1 and select doors. Highlight the door to modify and click edit to open the door properties window. Check the boxes as shown and adjust the timeout as desired. Click OK to save and exit.

To create an AC Link, expand AC Networks, Network 1, Panel 1 and select AC Links Click the green + to create a new AC Link. Select; Source Type Door Source Door 1 Event Door Forced Open Destination Type Sounder Destination Siren Operation Sounder Timer Time as required, default is 4 S Time Zone Always (by default) OK to save and close

To enable popup, check the box Generate Alarm then select Alarm Handler. Check the box Popup Enabled, optionally select a different color and add an alarm message as shown. Click OK to save and exit.

When an alarm occurs a popup will appear on the PC screen as shown. To immediately cancel the siren check the box Alarm Clear. Click OK to close and exit.

To create an AC Link, expand AC Networks, Network 1, Panel 1 and select AC Links Click the green + to create a new AC Link. Select; Source Type Door Source Door 1 Event Door Held Open Destination Type Sounder Destination Chime Operation Sounder On Time Zone Always (by default) OK to save and close