Scalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population Safety Issues Hidden Costs of Status Quo ASSE 1016 Update

Similar documents
Serving hotel, healthcare, education, commercial and residential markets since Proven superior valve technology

IntelliStation. The Smart Mixing & Recirculation System. For Domestic Hot Water in Commercial and Institutional Facilities. PowersControls.

Scald Hazards Associated

March

Thermostatic Mixing Valves

Water Heater Mixing Valve

Legionella Policy and Procedure

DIGITAL HOT WATER SOLUTIONS

Recommended Installation Practices for Residential Storage Type Water Heaters to Reduce the Danger of Scalds

Healthcare Solutions. Water, faucets, and the fight against healthcare-associated infections (HAIs)

Scald Hazards Associated

Water Tempering Innovation Since 1891

Frequently Asked Questions About Carbon Monoxide Detectors

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

R o n G e o r g e D e s i g n & C o n s u l t i n g N. D i x i e H w y. M o n r o e, M i c h i g a n

WATER TEMPERATURE MANAGEMENT POLICY

Nostracernium detore. Health and Care

Mixing Safety and Performance

Water Tempering Innovation Since 1891

Healthcare Solutions. The Right Remedies for Patient Safety and System Efficiency

Australasian Health Facility Guidelines. Part D - Infection Prevention and Control D Physical Environment

The Evolution of. Hot Water. Generation Systems. -Ron George. Geysir at Haukadalur, Iceland ( Ron George, 2016)

Safe Heating in Sheltered and Social Housing

The Dangers of Heat Stress

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

The Safety Valve Specialist Thermostatic Shower Controls

Take Back Control of Hot Water With Electronic Technology

Automatic Humidifiers

CHARACTERISTICS OF HOME FIRE VICTIMS

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

PROTECT WHAT YOU VALUE MOST

research highlight Canadian Housing Fire Statistics Findings

The Safety Valve Specialist TMV2. Thermostatic Mixing Valves. Engineered to a high specification, designed for safety and comfort

FREQUENTLY ASKED QUESTIONS

Domestic Hot Water Application manual

Build on Uponor with Aqua Port Central. Central fresh domestic hot water stations for private homes, hotels and healthcare

Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage

PartG. of the building regulations Sanitation, Hot Water and Water Efficiency (formerly Hygiene)

Structure Fires in Hotels and Motels

RCD , D 577, 417 US

The Safety Valve Specialist TMV3. Thermostatic Mixing Valves. Engineered to a high specification, designed for safety and comfort

INSTRUCTIONS FOR THE SUPERVISOR

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

HORNE 15 and 20 thermostatic mixing valve specification manual 2009

RHAPSODY. Recumbent bathing system. with people in mind

Digital Hot Water Systems

Carbon Monoxide Detection in Buildings Frequently Asked Questions

Humidity Control Combats Healthcare Associated Infection

Boil Water Advisories: Questions and Answers

Distribution Restriction Statement

New. Caprice Range 3 YEAR WARRANTY

Perfect Air Purifiers

plumbing PINPOINTING PRESSURE PROBLEMS

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

humantouch.com use & care manual

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put Into Perspective Electrocutions Can Be Prevented

SETS Systems * HOMEOWNER MANUAL *

OPERATING AND INSTALLATION MANUAL

WASHINGTON STATE PATROL

Hot water safety in bathrooms

GEOTHERMAL STORAGE TANKS

Ways to Save Water & Money

STUDY ISSUE PAPER ON THE RESIDENTIAL SPRINKLER ORDINANCE

Welcome to the 2 nd edition of idronics Caleffi s semi-annual design journal for hydronic professionals. caleffi.com. Mark Olson

Risk Assessment and Control Measures for Household Hot Water Systems

SELECTIONS FROM HOME COOKING FIRE PATTERNS AND TRENDS CHARCOAL GRILLS

NOTE TO EQUIPMENT OWNER:

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Issues Shaping the Outlook for the Remodeling Industry

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Trin & Stor Model Numbers: S, S-SR, SL Series Version Date:

Residential Structure Match or Lighter Ignited Fires

Domestic Water Heating Systems CEU 255. Continuing Education from the American Society of Plumbing Engineers. January ASPE.

OPERATING AND INSTALLATION MANUAL

Automatic Temperature Controller (ATC)

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual PT-30 PT-40 PT-50 PT-60 PT-80 PT-120

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Manifesto for the 2017 General Election: Preventing deaths and injuries in the home

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Distributed By: M&M Control Service, Inc SURFACE MOUNT SHOWER SYSTEMS

MODEL 7000 SUCTION UNIT

Instantaneous Water Heaters (IWH)

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

If you have any questions regarding this report, please contact Assistant Commissioner Bob Meier at or

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

T HE U NIVERSE E LECTRONIC F AUCETS

The Latest Innovations in Hand Washing Technology

Laird Engineered Thermal Systems Application Note. Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS

Model TWBS.SHE Tempered Water Blending System

Architectural Specification in the Healthcare Market

RADON LAZERWEB SERVICES

Machine Guarding BLR B L B R usi ne B s u s si & n e L s e s g a & l L R e e g s a o l u r R c e e s s o(u 1rc 7 e 1 s 0) 1

CHILDCARE SETTINGS. Childcare Settings

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Flow Factor ~

Thermostatic mixing valves with replaceable cartridge for centralized systems

Indoor Mold and Health A Fungus among Us

Honeywell Water Solutions. Thermostatic Mixing Valves

Transcription:

Special Report_0408.qxd 2/24/04 11:30 AM Page 2 SCALDING RISK LEGIONELLA AGING POPULATION HIDDEN COSTS CODES & STANDARDS The Rising Need for Advanced Shower Valve Technology Scalding Now a Healthcare Worry Legionella Cases on the Rise Aging Population Safety Issues Hidden Costs of Status Quo ASSE 1016 Update Prepared by Bruce Fathers Powers, a division of Watts Water Technologies, Inc.

Foreward Much of the information in this report was prepared in response to specifying engineers, healthcare facility managers, and an increasing SCALDING RISK 3 LEGIONELLA 4 AGING POPULATION 5 HIDDEN COSTS 6 number of inquiries from institutional and commercial facility managers who are concerned about shower valve safety. Powers welcomes any and all comments or questions regarding the content of this report. CODES & STANDARDS 7 Comments or Questions? Please call 1-800-669-5430 x6207 Or email: info@powerscontrols.com 2

Scalding Risk More than 112,000 individuals are admitted into hospital emergency rooms each year for scald-related injuries. American Hospital Association Medical statistics reveal that scald burns caused by hot water, flowing into the tub or shower, are the leading cause of severe burn injuries in the United States. Scalding cases have become so common in fact, that many hospitals have invested in scald victim treatment rooms. Why Are Scalding Incidents Rising? In 2001, an estimated 99,400 children were treated in hospital emergency rooms for burn related injuries. Of these, over 27,000 were scald burns. National Safe Kids Campaign Children under the age of five, the elderly, and people with mental and physical disabilities are more susceptible to scald burns. However, while higher birth and aging trends have brought more incidents of scalding into the healthcare, public, and legal arenas, the risk of scalding has long existed for several reasons. Thermal Shock is Another Danger Thermal shock is the physical reaction of a person to a rapid and uncomfortable change in shower water temperature. The temperature change can be either toward colder or hotter water. The danger of thermal shock is that the individual s sudden movement away from the water coming from the shower could cause a fall and serious injury. Effects of Water Temperature Plumbing that is lacking temperature control devices 140 F 1st degree burn, 3 sec. Improper plumbing maintenance or lack of maintenance Bathing of patients with delicate healing tissue concerns Inattentive bathing care of the elderly Unattended bathing of children, the handicapped, and the Normal dish/clothes washing and shaving range 130 F 120 F 1st degree burn, 30 sec. 1st degree burn, 8 min. elderly (those with diminished or undeveloped mental and physical capacities) 110 F Very hot shower 98.6 F Body temperature Causes of Temperature Change within a Plumbing System Seasonal temperature changes in water supply Authorized or unauthorized adjustment of upstream master tempering valve Failure of upstream tempering valve System pressure fluctuations, i.e. changing demand Boiler/hot water heater malfunction Improper valve selection (oversized) and/or hot water recirculation design Manufacturer Warnings / Forewarnings For years, shower valve manufacturers have included scalding warnings in the installation manuals that come with their pressureonly compensating shower valves. These pressure balancing shower valves have remained the prevailing valve choice, largely due to their relatively lower cost to facility owners and long time familiarity among plumbing contractors. See page 7 of this report for additional information about improved shower valve options. 3

Legionella on the Rise The CDC has estimated that the disease infects 10,000 to 15,000 persons annually in the USA. OSHA estimates that over 25,000 cases of the illness occur each year, causing more than 4,000 deaths (CDC estimates 30% who contract will die), still others estimate as many as 100,000 annual cases and between 2002 and 2003, the disease has doubled or tripled in some regions of the country. Association of Water Technologies Legionella 2003, June, 2003 Bacteria Thrives in Water 68-122 F Legionella is a type of pneumonia caused by Legionella, a bacterium found primarily in warm water environments. The disease can be contracted by inhaling airborne water droplets containing the bacterium. Legionella thrive within a narrow water temperature range of 68 122 F. Therein lies both the problem and the solution: To control the disease, facilities need to control the temperature of the water in their storage and delivery systems. Unless specifically targeted, many cases of Legionella are misdiagnosed as pneumonia because of symptom similarities. Even if detected, Legionella often goes unreported to public health authorities if incidences are low or are not associated with an outbreak investigation. Of the many hundreds of thousands of pneumonia cases that occur each year in the United States, some 10,000 to 100,000 are actually cases of Legionnaires disease. Effects of Water Temperature Ideal growth range 95-115 F Legionellae growth range 68-122 F Rapid Kill Range 158-176 F 50 F 75 F 100 F 125 F 150 F 175 F Below 68 F, Legionellae can survive but are dormant. Cold water in storage tanks, piping, decorative fountains, and other equipment should ideally be kept below 68 F. Hot water need capability of heating water to 158 F for disinfection 151 F Legionellae die within 2 minutes 140 F Legionellae die within 32 minutes 131 F Legionellae die within 5-6 hours Above 122 F Legionellae can survive but do not multiply Control of Water Temperature is Critical OSHA, ASHRAE, the CDC and other authorities have all published recommendations to control Legionella. In every case, these authorities point to the water delivery system as being critical. OSHA recommends that domestic hot water should be stored at a minimum of 140 F and delivered at a minimum of 122 F to all outlets to minimize the growth of Legionella. In their latest guidelines for bacteria control and Legionella risk reduction, both the CDC and ASHRAE recommend hot water recirculation at a minimum of 124 F (51 C) and installing temperature control valves at the point-of-use to reduce scalding risk. This health concern magnifies the importance of using a water delivery valve that is not of a pressure-only design, but is thermostatic or a combination of each to prevent scalding. 4

Our Aging Population The number of US citizens aged 65 and older will reach 70.18 million by 2030. This represents the highest ever, a full 20% of the population. Source: U.S. Census Bureau New High Risk of Scalding Injuries By the year 2050, the U.S. Census Bureau estimates our senior population will grow to in excess of 80 million, more than double its current size. Add to this the percentage of young children, and the total population most at-risk to scalding injuries will exceed 75%. Elderly people lose the ability to respond quickly Injuries occur due to falling when reacting suddenly to thermal shock Momentary exposure to excessively hot water can result in 2nd or 3rd degree burns Related incidents of scalding will increase with the aging population Increased scalding injuries will result in increased litigation The baby-boomer population will drive scald prevention legislation Population Growth Chart (in millions) 100 80 60 40 20 28.42 33.16 33.65 35.32 40.10 53.35 70.18 77.01 80.11 0 1985 1994 1995 2000 2010 2020 2030 2040 2050 Table 1 - Population ages 65 Years and Over: 1985-2050 (Source: US Census Bureau) A Painful Lesson Learned Hospital patients, those with disabilities or in physical rehabilitation, and most people within nursing facilities are known to have delayed reactions to a sudden rise in water temperature. Pain is the body s means of protecting itself. Yet illness or medication, as well as the delayed reactions of the elderly, can all affect the pain warning mechanism. For this reason, the aging population is exponentially exposing more people to the risk of severe tissue damage, burns, and death. Healthcare Facilities Finding the Cure The healthcare industry has been the first to evaluate an apparent Catch-22 dilemma. Decreasing hot water temperature in a delivery system reduces the danger of scalding, but increases the risk of bacteria growth. Increase the hot water temperature and just the opposite risks occur. Now add to this the need for energy conservation and the common practice of reducing thermostat settings for water heaters and the conclusion to all of this has revealed itself: Past methods of water delivery are no longer adequate. 5

Hidden Costs WARNING: Failure to adjust the limit stop screw properly may result in serious scalding. CAUTION: This valve does not automatically adjust for inlet temperature changes, therefore someone must make the necessary Rotational Limit Stop adjustments at the time of the installation and further adjustments may be necessary due to seasonal water temperature change. YOU MUST inform the owner! CAUTION: Due to season temperature change of the cold water supply, the temperature limit must be readjusted accordingly to maintain the desired maximum discharge temperature. Leading Manufacturers of Pressure Balancing Type Shower Valves Old Problem Under New Scrutiny To prevent a person from drawing water that is dangerously hot, pressure balancing valves come with a limit stop that needs to be installed and adjusted seasonally to allow for cold water temperature changes flowing into the water system. For decades, this limitation in pressure valve design has prevailed despite the manufacturer warnings and cautions. Limit Stops Are Rarely Adjusted Common sense and common practice are two different things. While manufacturers have long warned facility managers to routinely and seasonally set the limit stop on all of their shower valves, the cost and aggravation of doing so defies common practice. Take for example, a 500-room facility. With twice-annual seasonal adjustments, and allowing just 10 minutes per valve, and at an hourly rate of $25 per hour, the annual cost for setting the limit stops would be $4,166. As early as the 1980 s, the Consumer Product Safety Commission warned of the need to set the temperature-limiting devices on pressure balancing type shower valves. In a June 1984 report, the Commission reported it was aware of 12 incidents, including 4 deaths, associated with a single brand of pressure balancing shower valve. And yet, today, pressure balancing type shower valves continue to be specified at the risk of being improperly installed and without seasonal adjustment in motels, hotels, apartments, nursing homes, institutional care facilities and athletic facilities. Anticipating a rise in litigation related to scalding injuries, specifiers, installers, and facility managers now have an additional potential cost to consider when installing pressure type shower valves a cost that can be significantly higher than the proper installation of limit stops and perennial limit stop adjustments. Seasonal Cold Water Adjustments Seasonal cold water increase & affect on type P valves* HOT WATER TEMPS PRESSURE BALANCING RESPONSES 160 125.0 128 140 122.5 124 120 122 100 120.0 120 80 117.5 118 60 116 115.0 40 114 20 112 0 40 50 60 70 80 110 COLD WATER TEMP. * without adjustment of limit stop OUTLET WATER TEMP. 6

A Higher Standard The American Society of Sanitary Engineers (ASSE), with its membership of shower safety valve manufacturers, has authored performance standards that govern water safety valves. ASSE 1016 governs point-of-use shower valves ASSE recognizes three basic types of bath and shower valves Type P Pressure balancing valves for pressure regulation Type T Temperature valves for temperature and some pressure regulation Type T/P Both temperature and pressure regulation The Limits of Pressure Balancing Valves Type P While pressure-balancing valves will compensate for pressure fluctuations within a plumbing system, these types of valves cannot make adjustments for sudden or gradual changes in supply temperature. If hot water supply line temperature unexpectedly increases to a dangerous level while inlet water pressure remains constant, the pressure balancing valve will continue to pass water but at a dramatically increased temperature. Pressure balancing valves react to water pressure changes only. They are not designed to sense temperature changes and so do not provide true temperature regulation. Pressure balancing valves can provide some level of protection against scalding when limit stops are adjusted seasonally. Pressure balancing valves do not provide complete protection when coupled with upstream thermostatic valves (master mixers) in the event of a valve failure. WARNING: This shower system may not protect the user from scalding when there is a failure of other temperature controlling devices elsewhere in the plumbing system. Type T/P Valves Prevent Problems Also known as combination valves, Type T/P valves are required to meet ASSE 1016 s most stringent performance requirements for both temperature and pressure changes. Type T/P valves allow water to be generated at higher temperatures, distributed at higher temperatures, and delivered at safe temperatures to the bather alleviating the risks of scalding and the growth of Legionella bacteria in a water delivery system. In addition, Type T/P valves require no seasonal adjustment of the limit stop, saving potentially thousands of dollars over the life of a system. Valve Type Protection Provided per ASSE 1016 Hot Water Supply pressure Point-of-use temperature fluctuations increases up to 50% -Type P- Pressure Balance NO YES Leading Shower Valve Manufacturer -Type T- Thermostatic YES NO The Limits of Common Thermostatic Valves Type T -Type T/P- Combination YES YES Handle only 20% pressure fluctuations, not 50% Very expensive, 3 to 4 times that of pressure balancing Other ASSE Standards ASSE 1017 Hot water distribution (Powers e430, 1430 series) ASSE 1070* Water tempering at sinks and lavatories (Powers model e480) ASSE 1069* Water tempering to gang or multiple showers (Powers model e427/e428) ASSE 1062 Temperature activated, flow reduction valves (Powers model HT115) *under development 7

ASSE 1016 T/P Technology Total Protection is Now Affordable Powers has developed the first affordable type T/P shower valve to minimize the risk against scalding, Legionella, and the elimination of labor costs associated with pressure balancing valve limit stop adjustments. The e700 features an improved valve design and actuation technology, and is priced competitively with less protective Type P and T valves. Originally developed for healthcare facilities, the e700 valve is now being widely specified for institutional, commercial, lodging, sports and recreational facilities to provide the highest ASSE 1016 rated solution. Powers has also introduced the first T/P valve for lavatory tempering as well, so now you can specify the e480 for total bathroom protection. HydroGuard T/P e700 Series for Bath and Showers HydroGuard T/P e480 Series for Lavatories For a free brochure or to talk to a Powers engineer, please call 1-800-669-5430. Or visit: www.powerscontrols.com USA Phone: 800.669.5430 Canada Phone: 888.208.8927 www.powerscontrols.com Form # SRSVS 0408 2004 POWERS, a division of Watts Water Technologies, Inc. Printed in U.S.A.