Optical laser distance sensors. Dimensioned drawing

Similar documents
Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

SRK 96. Safety Reto-reflective Light Barrier. CONNECTING AND OPERATING INSTRUCTIONS Original Instructions

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

SELECTION TABLE x 42 x x 48 x x 50 x M12 x 70. Housing material. Typ. operating range/scanning range [mm]

HRTL 96B Laser light scanner featuring background suppression for object detection and accurate positioning

MSI Safety relays. MSI-T functions

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

Series 25B Photoelectric Sensors and Light Scanners PRODUCT INFORMATION

CATALOGUE LASER POINTERS

Class 1 laser beam sensor safe for your eyes

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

Class 1 laser beam sensor safe for your eyes

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Laser Distance Sensor Type M Analog-Output

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Class 1 laser beam sensor safe for your eyes

Laser Collimated Beam Sensor

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

BOS 23K. Photoelectric Sensors BOS 23K

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

LIGHT CURTAINS. Measuring and switching light curtains for a wide variety of applications.

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

64 Max IR Thermometer

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Optical system Beam shape Sensing distance Resolution*1 Model Diffuse reflective Spot beam 40±10 mm 2 µm ZX-LD40. Line beam 40±10 mm 2 µm ZX-LD40L

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

M12 Class 1 Laser Emitter

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

Important Safety Notice

E3M-V. Mark Sensor. Applications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Multi Line Laser Level Model: L203

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

INTERNATIONAL STANDARD

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

M12 Class 2 Laser Emitter

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Retro-reflective Sensing range: 0mm to 2000mm

PHOTOELECTRIC AMPLIFIER SERIES

2 General Application Photoelectric Sensors

CAPACITIVE SENSORS. Reliable detection of objects and fi ll levels.

Automatic Self-Adjusting General Purpose Sensor

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

M5200 Industrial Pressure Transducer

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

SCHMIDT LED Measured Value Display MD Instructions for Use

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

U5300 Industrial Pressure Transducer

MLDSET Light Beam Safety Device Sets for access guarding with muting function

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

The Affordable, All-Purpose Sensor That's EZ To Use!

Beck. The differential pressure transmitter for air

02/11/2015

General Purpose Photoelectric Sensor

2 General Application Photoelectric Sensors

46C SERIES. powerreserve. Photoelectric sensors and light scanners with maximum function reserve.

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Instruction Manual. Self-Leveling Laser Level Model No

64 Max IR Thermometer

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

2 General Application Photoelectric Sensors

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

GuardShield TM Safe 4 GuardShield TM Safe 4 PAC

M5800 Pressure Transducer with Rotatable Display

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

Information for Proper Posting & Laser Area Sign Templates

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

G4 Pulsed Fiber Laser

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Apollo Intelligent Auto Aligning Beam Detector. User Guide

2 General Application Photoelectric Sensors

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

CL3 HYBRID MULTI-LINE LASER INSTRUCTION MANUAL

UNIVERSAL COMPACT SENSORS

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

WIO200 Water In Oil measuring instrument

02/11/2015

100 Ft. LASER DISTANCE METER

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

WIO 200B and WIOI200B Water in oil sensor

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

Transcription:

Optical laser distance sensors Dimensioned drawing en 08-2014/07 50103924-02 150 2300mm We reserve the right to make changes DS_ODSL96KV662300_en_50103924_02.fm Reflection-independent distance information Analog voltage output 1 10V (can be inverted, teachable) 2 teachable switching outputs (push-pull) Easy alignment through visible red light IEC 60947... IEC 60947... IP 67 Accessories: (available separately) Mounting systems Cable with M12 connector (K-D ) A Green indicator diode B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK nut M5, 4.2mm deep H Teach button Electrical connection Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.com www.leuze.com ODSL 96K/V 66-2300-S12-08

Specifications Optical data Measurement range 1) 150 2300mm Resolution 2) 1 5mm Light source laser Wavelength 650nm (visible red light) Max. output power <1.2 mw Pulse duration 4ms Light spot divergent, 3x8mm² at 2300mm Error limits (relative to measurement distance) Absolute measurement accuracy 1) ±3% Repeatability 3) ±2% B/W detection thresh. (6 90% rem.) 1% Temperature drift 0.1%/ C Timing Measurement time 2 7ms Response time 20ms Delay before start-up 300ms Electrical data Operating voltage U B 18 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current 150mA Switching output/function 4) 2 push-pull switching outputs pin 2: Q2, PNP light switching, NPN dark switching pin 4: Q1, PNP light switching, NPN dark switching Signal voltage high/low (U B -2 V)/ 2V Analog output voltage 1 10V, R L 2kΩ Indicators Green LED continuous light ready flashing (no teach) fault, teach values were not applied off no voltage Yellow LED continuous light object within teach-in measurement distance (output Q1 5) ) flashing (no teach) teach values were not applied off object outside teach-in measurement distance (output Q1 4) ) Mechanical data Housing plastic Optics cover plastic Weight 140g Connection type M12 connector Environmental data Ambient temp. (operation/storage) -20 C +40 C/-30 C +70 C Protective circuit 6) 1, 2, 3 VDE safety class 7) II, all-insulated Protection class IP 67 Laser class 2 (acc. to EN 60825-1) Standards applied IEC 60947-5-2 1) Luminosity coefficient 6% 90%, at 20 C, measurement object 50x50mm² 2) Minimum and maximum value depend on measurement distance and configuration of the analog output 3) Same object, identical environmental conditions, measurement object 50x50mm² 4) The push-pull switching outputs must not be connected in parallel 5) No display for output Q2 6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 7) Rating voltage 250VAC Characteristic curve of analog output: A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Tables Diagrams Characteristic curve of switching outputs: A Hysteresis B Switching point Q1 (teach point) C Switching point Q2 (teach point) D Measurement distance Remarks Intended use: The ODSL 96 distance sensors are optoelectronic sensors for the optical, contactless measurement of distance to objects. Operate in accordance with intended use! This product is not a safety sensor and is not intended as personnel protection. The product may only be put into operation by competent persons. Only use the product in accordance with the intended use. Order guide Designation Part no. With M12 connector and analog output ODSL 96K/V 66-2300-S12 50101881 Measurement time depends on the reflectivity of the measurement object and on the measurement mode. ODSL 96K/V 66-2300-S12-08 2014/07

Optical laser distance sensors Laser safety notices ATTENTION, LASER RADIATION LASER CLASS 2 Never look directly into the beam! The device fulfills the EN 60825-1:2008-05 (IEC 60825-1:2007) safety regulations for a product in laser class 2 as well as the U.S. 21 CFR 1040.10 regulations with deviations corresponding to "Laser Notice No. 50" from June 24th, 2007. Never look directly into the laser beam or in the direction of reflecting laser beams! If you look into the beam path over a longer time period, there is a risk of injury to the retina. Do not point the laser beam of the device at persons! Intercept the laser beam with an opaque, non-reflective object if the laser beam is accidentally directed towards a person. When mounting and aligning the device, avoid reflections of the laser beam off reflective surfaces! CAUTION! Use of controls or adjustments or performance of procedures other than specified herein may result in hazardous light exposure. The use of optical instruments or devices (e.g., magnifying glasses, binoculars) with the product will increase eye hazard. Adhere to the applicable legal and local regulations regarding protection from laser beams acc. to EN 60825 (IEC 60825) in its latest version. The device must not be tampered with and must not be changed in any way. There are no user-serviceable parts inside the device. Repairs must only be performed by Leuze electronic GmbH + Co. KG. NOTICE Affix laser information and warning signs! Laser information and warning signs are affixed to the device(see ). In addition, self-adhesive laser information and warning signs (stick-on labels) are supplied in several languages (see ). Affix the laser information sheet with the language appropriate for the place of use to the device. When using the device in the US, use the stick-on label with the "Complies with 21 CFR 1040.10" notice. Affix the laser information and warning signs near the device if no signs are attached to the device (e.g. because the device is too small) or if the attached laser information and warning signs are concealed due to the installation position. Affix the laser information and warning signs so that they are legible without exposing the reader to the laser radiation of the device or other optical radiation. 50101928-02 LASERSTRAHLUNG NICHT IN DEN STRAHL BLICKEN Max. Leistung (peak): 1,2 mw Impulsdauer: Wellenlänge: LASER KLASSE 2 DIN EN 60825-1:2008-05 RADIAZIONE LASER NON FISSARE IL FASCIO Potenza max. (peak): 1,2 mw Durata dell'impulso: Lunghezza d'onda: APARRECCHIO LASER DI CLASSE 2 A LASER RADIATION DO NOT STARE INTO BEAM Maximum Output (peak): 1.2 mw Pulse duration: Wavelength: CLASS 2 LASER PRODUCT RAYONNEMENT LASER NE PAS REGARDER DANS LE FAISCEAU Puissance max. (crête): 1,2 mw Durée d`impulsion: Longueur d`onde: APPAREIL À LASER DE CLASSE 2 B AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THIS APERTURE EXPOSITION DANGEREUSE UN RAYONNEMENT LASER EST ÉMIS PAR CETTE OUVERTURE RADIACIÓN LÁSER NO MIRAR FIJAMENTE AL HAZ Potencia máx. (peak): 1,2 mw Duración del impulso: Longitud de onda: PRODUCTO LÁSER DE CLASE 2 RADIAÇÃO LASER NÃO OLHAR FIXAMENTE O FEIXE Potência máx. (peak): 1,2 mw Período de pulso: Comprimento de onda: EQUIPAMENTO LASER CLASSE 2 LASER RADIATION DO NOT STARE INTO BEAM Maximum Output (peak): Pulse duration: Wavelength: CLASS 2 LASER PRODUCT Complies with 21 CFR 1040.10 1.2 mw GB7247.1-2012 1.2 mw A B Laser exit opening Laser warning sign Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 ODSL 96K/V 66-2300-S12-08 info@leuze.com www.leuze.com

T I teach-in with teach button 1.Position measurement object at the desired measurement distance (➀). ➀ 2.The respective teach function is activated by operating the teach button (➁) for different amounts of time. The activated teach function is signaled by a flashing of the LEDs. Teach function Duration of teach button operation Green LED Yellow LED Switching output Q1 2 4s Flash synchronously Switching output Q2 4 6s Flash alternatingly 1V analog output 6 8s On Flashes 10V analog output 8 10s Flashes On 3.Release teach button (➁) and wait for optical confirmation by end of flashing signal (green LED on). Reset of the analog output to factory settings Reset 1V analog output at 150mm: 1.Position measurement object just below start of measurement range (150mm). 2.Press teach button for 6 8s (green LED on, yellow LED flashes). 3.Release teach button and wait for optical confirmation by end of flashing signal (green LED on). Reset 10V analog output at 2300mm: 1.Position measurement object just beyond end of measurement range (2300mm). 2.Press teach button for 8 10s (green LED flashes, yellow LED on). 3.Release teach button and wait for optical confirmation by end of flashing signal (green LED on). Error messages Continuously flashing LEDs signal an unsuccessful teach event (sensor not ready): Green LED Yellow LED Error Flash synchronously Teach switching output Q1 unsuccessful Flash alternatingly Teach switching output Q1 unsuccessful On Flashes Teach 1V analog output unsuccessful Flashes On Teach 10V analog output unsuccessful Remedy: Repeat teach event or Press teach button for more than 10s or Disconnect sensor from voltage to restore the old values. ➁ Teach button ODSL 96K/V 66-2300-S12-08 2014/07

Optical laser distance sensors Typical areas of application of optical distance sensors Continuous distance measurement Positioning tasks Filling level control ODSL 96 ODSL 96 New stack ODSL 96 Positioning Installation instructions Mounting systems are available which have to be ordered separately at Leuze electronic. Apart from this, the drilled-through holes and threaded holes are suitable for the individual mounting of the ODSL 96, depending on the area in which it is used. When mounting, avoid application of excessive force on the housing. Preferred movement of the objects Preferred mounting in connection to objects with structured surface View through a chase If the ODSL 96 has to be installed behind a cover, the chase has to have at least the size of the optical glass cover. Otherwise, a correct measurement is not possible or can not be guaranteed. Alignment to measurement objects with reflecting surfaces If the measurement object to be detected has a reflecting surface, a measurement may not be possible depending on the angle in which the light is reflected by the measurement object's surface. Adjust the angle between the sensor and the measurement object such that the sensor can reliably detect the measurement object. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 ODSL 96K/V 66-2300-S12-08 info@leuze.com www.leuze.com

ODSL 96K/V 66-2300-S12-08 2014/07