Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

INTELLIKNIGHT 5820XL. Installation and Operation Manual. Addressable Fire System. Part Number H, 10/03

SILENT KNIGHT IFP-1000

4.1 Mounting the 5820 Cabinet Removing the 5820 Assembly from the Housing AC Connection Battery Connection...

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

INTELLIKNIGHT MODEL 5808

INTELLIKNIGHT MODEL 5700

Fire Alarm Control Systems

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

PART IV DETAILED SPECIFICATION

FARENHYT ORDER FORM Page 1 of 5

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

INTELLIKNIGHT 5820XL. Installation and Operations Manual. Addressable Fire System. Document L8 05/09/2012 Rev: T P/N L8:T ECN

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

INTELLIKNIGHT 5820XL. Installation and Operations Manual. Addressable Fire System. Document L8 04/01/2011 Rev: S P/N L8:S ECN

Silent Knight Software Suite Intelliknight Training

INTELLIKNIGHT Model 5808

Addressable Fire Alarm Control Panel

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

INTELLIKNIGHT MODEL 5700

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

INTELLIKNIGHT MODEL 5700

MODEL IFP-2000/ RPS-2000

Section 8 System Operation

IFP-2000 F r a en e h n y h t y PH P D

Fire Alarm Control Systems Simple. Smart. Reliable.

MODEL IFP-100. Installation and Operations Manual. Analog/Addressable Fire Control Panel. Part Number Rev L

DS7400Xi Addressable Control/ Communicator

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

Intelligent 2 & 4 Loop Fire Alarm Control Panels

D7024 Fire Alarm Control Panel

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

SILENT KNIGHT. IntelliKnight Smoke Detector Cleaning and Testing Instruction. Equipment Needed. Testing Equipment. Cleaning Equipment

Intelligent Single Loop Fire Alarm Control Panel

Section 9 System Operation

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

NETWORK FIRE ALARM CONTROL PANEL. Features

Version /17. Honeywell Gamewell-FCI Honeywell Security and Fire 12 Clintonville Road Northford, CT 06472

4007ES Fire Control Panels

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

Integrated Security Solutions

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

intelligent fire alarm ID60series panels

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

good things in small packages

LifeAlarm Fire Alarm Control Panels

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Conventional Releasing Control Panel

INTELLIGENT FIRE ALARM CONTROL PANEL

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

4007ES Fire Control Panels

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC Listed, FM Approved* Features

CATALOG NUMBER. Features. Description

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Innovative protection that combines power and flexibility

Integrated Security Solutions

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

AFP-400 Analog Fire Panel MEA E. City of Chicago Class 1: 1291E Class 2: 1792E GENERAL FEATURES. A Pittway Company

CODESEC FIRE ALARM SYSTEMS. security technologies

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Multiplex Eight Input Remote Modules

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

AND ARCHITECT SPECIFICATIONS

Mircom FX /01/16

Intelligent Addressable Fire Alarm System

Vigilant V-Series Intelligent Analog Life Safety Systems A practical overview of product highlights and competitive advantages

ID50series. intelligent fire alarm panels

SECTION FIRE ALARM SYSTEMS

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Control/Communicator

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

AX Series INTELLIGENT FIRE ALARM CONTROL PANEL INSTALLATION & OPERATION MANUAL ( AND )

FMR Installation Instructions. Addressable Fire System Controller

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Specification/ Data Sheet

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

D720 and D1255 Command Centers

Sophisticated. io-series Intelligent fire alarm solutions for small buildings. An EDWARDS brand.

Fire Control Units. Addressable Fire Detection and Basic Control Unit Modules and Accessories. UL, ULC Listed, FM Approved* Features

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

30.45 Electric Release PDRP-2001

Intelligent addressable fire alarm control panel

Data/ Specification Sheet

Transcription:

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability. With support for a wide variety of detectors, modules, and accessory devices, the 5820XL is configurable for a variety of installations. The 5820XL has one built-in signaling line circuit (SLC) to which all detectors and modules are connected. Add up to three additional SLCs with the 5815XL signaling line circuit expanders. Six onboard Flexput circuits are individually configurable for auxiliary power, notification outputs, or conventional smoke detectors. The 5820XL also has a built-in dual-line digital fire communicator, a Form C trouble relay, and two programmable Form C general purpose relays. 2

Selling Strategies IntelliKnight 5820XL Sales Guide Target Customers Medium to large size customers Customers involved in: - New construction - Retrofitting existing construction - that is, replacing older or outmoded fire alarm systems in existing buildings Customers in vertical markets such as the healthcare, education, manufacturing, financial and other similar facilities Typical Customer Profiles Customers with large campus operations Customers requiring a cost effective solution to retrofit their facility with a new fire alarm system Customers who require effective monitoring and maintenance tools for ongoing customer support Qualifying Questions 1. Are you considering a conventional fire system for your new installation? The advanced capabilities of the 5820XL will increase the effectiveness of your alarm system. With pinpoint addressable capabilities and advanced maintenance capabilities, the 5820XL FACP can actually reduce the total installed cost and reduce the long-term operating expenses associated with the system. Additionally, it is expandable for future upgrades. 2. Are you considering replacing an older conventional or addressable system? The 5820XL does not require special wire or installation strategies and can often be installed using existing fire system wiring within the building. This flexibility can be a big savings when installing a retrofit fire system. 3. Do you want the ability to expand your fire alarm system in a cost-effective way? The 5820XL is ideal for growing businesses. If your facility grows, and your SLC is at maximum capacity, add up to three 5815XLs. Add the 5895XL intelligent power supply to provide additional power, connectivity for additional SLCs, or additional accessories. 3

Selling Points Analog addressable architecture enhances reliability, pinpoints problem area, and reduces false alarms With features like individual point identification, drift compensation, and maintenance alert this system is designed to help reduce the number of false alarms and service calls that can be so frustrating and costly. Designed for expandability and flexibility Comes with a full range of detectors, modules, and power supplies to meet installation needs. SLC expanders give you the ability to accommodate a growing business while avoiding the hassle and expense of getting a new system. Critical system programming and event information can be stored and updated remotely by the installation company The 5660 Silent Knight Software Suite (SKSS) allows your installation company to connect to the 5820XL from their offices or at your location, which means they can efficiently maintain and troubleshoot the fire system. Easy to install The JumpStart feature scans all SLC loops and SBUS circuits, determines device type, adds the device to FACP memory, and automatically selects some system options based on device type. This saves the installer from having to program options for each device. When it comes to wiring the system, the Silent Knight SLC loop does not require special wire such as shielded wire or twisted pair, making retrofits a breeze. Because detectors and modules each have a unique address, troubleshooting is a snap. 4

Features & Benefits Built-in support for 127 devices, expandable to 508 devices Support the minimum or expand to the maximum number of devices or add devices in the future. Uses standard wire. Shielded or twisted pair is not required Upload and download programming information, event history, and detector status onsite or from a remote location using SKSS software Configure Flexput I/O circuits as auxiliary, notification outputs, or conventional smoke detector inputs JumpStart autoprogramming adds all devices connected to the system automatically. Nonvolatile event history stores up to 1,000 events Using standard wire for new installations can reduce installation time and costs over shielded or twisted pair. For retrofit installations, existing wire runs can be used, eliminating the expense of running new wire. To easily service and maintain the 5820XL system, your facility manager can view and save event history to identify any system problems using 5670 SKSS. Your installer can program or view event history and detector status using 5660 SKSS. Patented Flexput circuits let you retrofit an existing conventional installation, without additional hardware, so existing detectors do not have to be replaced. As well, expand system functionality by adding new devices that fully are compatible with the 5820XL. Run when installation is complete to quickly add all detectors and modules to the system. Saves installation time. Your installer can view event history to assist in troubleshooting and system maintenance. 5

Figure 1: 5820XL Configuration Example 6

7

Ordering Information The range of SLC devices, SBUS accessories, and miscellaneous accessories compatible with the 5820XL are described briefly in this section. SLC Detectors & Modules Detectors and modules connect to the signaling line circuit (SLC) loop on the FACP or 5895XL. All these devices are SLC devices. SD505-APS Photoelectric smoke detector. SD505-AHS Fixed temperature heat detector. SD505-AIS Ionization smoke detector. SD505-ADH Duct detector housing for use with SD505-APS or SD505-AIS to detect smoke and combustion products in HVAC ducts. SD505-ADHR Duct detector house for use with SD505-APS or SD505-AIS to detect smoke and combustion products in HVAC ducts. SD500-AIM Dry contact input module provides an interface to contact devices. SD500-MIM A compact input monitor module that provides an interface to contact devices. SD500-ARM Relay module with two Form C relay contacts. SD500-ANM Notification module. SD500-SDM Two-wire interface module. SD500-LIM Line isolator module. SD500-LED LED driver module for up to 80 LEDs. SD500-PS Single action pull station. SD500-PSDA Dual action pull station. SD505-6AB 6 mounting base for use with SD505-APS, SD505-AHS, SD505-AIS. SD505-4AB 4 mounting base for use with SD505-APS, SD505-AHS, SD505-AIS. 8

Ordering Information (cont.) SD505-6SB 6 mounting base with built-in sounder. IntelliKnight 5820XL Sales Guide SD505-6RB 6 mounting base with one built-in Form C relay contact. SD505-6IB 6 mount base with built-in isolator for use with SD505-APS, SD505-AHS, and SD505-AIS. SD505-DTS Remote test switch for use with the SD505-ADHR. SBUS Accessories SBUS accessories connect to the 5820XL SBUS on the FACP or an intelligent power module. 5860 Remote annunciator with four-line, 20 character per line LCD display. 5815XL Signaling line circuit expander used to add another SLC loop to the system. 5895XL Six amp intelligent power supply that adds six Flexput I/O circuits and two Form C relays to the system. 5496 Six amp intelligent power supply that provides four notification appliance circuit outputs. 5824 A serial/parallel interface module used to connect a printer to the system. 5880 LED I/O module provides 40 programmable LED outputs and eight supervised dry contact inputs. 5865-3 & 5865-4 LED fire annunciators provide a visual indication of the current state of system zone inputs. 5883 Relay interface board provides 10 general purpose Form C relays used to control any device that requires a dry contact closure. 9

Ordering Information (cont.) Miscellaneous Accessories A variety of accessories are available to support the FACP operations, troubleshooting, and maintenance. 5660 Silent Knight Software Suite used for programming and viewing events. This is a Windows-based, user-friendly application that can be used at the installation site or remotely with a modem. 5670 Silent Knight Software Suite used for facility management. This is a powerful end-user facility management software that allows for viewing of detector status and event history via a modem or a direct connection. Plex-1 Door accessory that combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions to satisfy those jurisdictions where required. RBB Remote back up battery box accessory cabinet that is used if backup batteries are too large to fit into the FACP cabinet. 10

Features Summary Onboard Addressable Points 127 Maximum Addressable Points with Optional 5815XL SLC Expanders 508 Notification Appliance Circuits 6 Onboard; Expandable to 56 Power Supply 6A ANSI Compliance 3.41 Cadence Uploading/Downloading System Programming, Detector Status, and Event Information Digital Communicator Local using 5660 SKSS or Annunciator and remote capability using 5660 SKSS Built-in Relay Outputs 3 Remote Annunciator Display Types Available LCD and LED Onboard Annunciator 80 Character LCD Alarm Reporting By Point or Zone Communication Bus RS-485 Panel Connectivity for Programming USB or Serial Event History Storage 1,000 Events Stored in Non-volatile Memory Device Naming Printing Customizable text labels for detectors and modules for easy point identification Detector Status, Event History, and Real Time Event Log with Optional 5824 Approvals NFPA; UL; CSFM 7170-0059: 135; MEA 429-92-E Vol. VI; FM 11

7550 Meridian Circle N, Suite 100 Maple Grove, MN 55369 800-328-0103 www.silentknight.com p/n 350931 A 6/06