FireMaster Instrument cable tray fire protection

Similar documents
FireMaster fire protection systems

Fire Protection Industry

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

BANK UNDERDRAIN (ALTERNATE LOCATION) (PIPE SHALL BE WRAPPED WITH GEOTEXTILE) DRAINAGE LAYER GRANULAR MATERIAL CLASS II 3" NOMINAL DEPTH

CERTIFICATE OF FIRE APPROVAL

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Darchem Thermal Protection

Why Passive Fire Protection of Critical Controls? Why K-Mass? Why Thermal Designs, Inc.?

PERFORMANCE OF PASSIVE FIRE PROTECTION IN JET FIRES

Installing Protectowire Linear Heat Detector

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Test Report: ICL/H18/9039 Rev 1

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

INSTALLATION AND OPERATION MANUAL FOR HUUM DROP ELECTRIC SAUNA HEATER

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Public Comment No. 1-NFPA [ Section No ]

Fire Test Methods ASTM NFPA UL ISO IEC

Cleanroom Materials Flammability Test Protocol

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

OIL AND GAS INDUSTRY

Protective & Marine Coatings Europe, Middle East, Africa & India

First Revision No. 6-NFPA [ Section No. 2.2 ]

CSST Test Report. Report Date: April 19, Prepared By: Richard B. Loucks, PhD, PE Senior Mechanical Engineer

Cablosam Tapes for Fire-Resistant Cables

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

ProTek Fire and Blast Wall Certification Summary

EUTECTIC EC-10DV Series

Darchem Thermal Protection

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

Welding Job Knowledge

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

HRS Hand Rail System 1

Catalogue Power Cables

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

Always make sure to check the heating film before, during, and after installation of the floor covering.

Passive protection against hydrocarbon hazards

HOTFOIL HB MODULE HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL HB.IOM.R3

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Understanding Etched Foil Flexible Heaters

Refrigeration Technology in Building Services Engineering

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

NFPA 30 FLC-SWC First Revisions Page 1 of 10 11/6/2015 9:21 AM. First Revision No. 208-NFPA [ Section No ]

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

SECTION FIRE PUMP AND CONTROLS

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

STUDY ON THE REACTION TO FIRE OF MEDIUM VOLTAGE CABLES SYSTEMS

Cartridge Heaters. Components. Application Guidelines

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

Method Statement. General Site preparation by others: Preparation for screed system by others: Preparation for plate system by others:

Are Your Kitchen Hood Filters Compliant?

HVS S Splice Series

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

DUAL MIRROR ALUMINIZED FABRICS. Protection You Can Count On. Value You Can t Beat.

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Type CODE Speed Heating Cooling

Snohomish County PUD #1 HEAT PUMP SYSTEM INSTALLATION STANDARDS

Saving lives with coatings

Containment of Basket Filtration Centrifuges ABSTRACT

Installation Instructions Wall Ovens

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Mineral Insulated Band Heater

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Catalogue Telecommunication Cables INTRODUCCIÓN

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

Catalogue. Instrumentation & Control Cables

Two (2) Side Rail Cable Tray

NS1100 / NS2200 Installation Guide & Owner s Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

FLANGE ISOLATION KITS

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

FIRE TESTING OF LOW SLOPE ROOF ASSEMBLIES AN INTERNATIONAL REVIEW

NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX

VACUUM VALVES AND HOSES

This document is a preview generated by EVS

3gb53231b.fm5 Page 12 Friday, April 11, :21 PM

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

Vacuum Bonding of Safety and Architectural Glass Laminates

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

04.SOIL MOISTURE MEASUREMENT

High Performance Heater with More Efficient Heat

Dust Explosion Protection Consistent with North American Practice

C-01 FIRE DECKS AND BULKHEADS

Transcription:

FireMaster Instrument cable tray fire protection FIRE PROTECTION 41

Instrument cable tray fire protection 30 minute hydrocarbon fire protection FireMaster products insulate cable trays carrying instrument control cables to ensure that the cables can operate long enough to allow process shut down during fires. The FireMaster cable tray wrap system provides 30 minutes hydrocarbon fire protection to cable trays carrying control cable wiring. The FireMaster cable tray wrap consists of FireMaster Marine Plus blanket fully encapsulated in aluminium foil supplied and in a roll form. It is wrapped around the exterior of the cable tray and held in place with steel banding straps. Additional weather protection can be installed if required using corrugated aluminium sheeting. 42

The FireMaster cable tray wrap system has been installed in many chemical process plants worldwide and is fire tested to the stringent ASTM E1725 method. It can be installed in one single layer which means installation time is quick and the wrap can be easily removed from the cable tray if retrofitting of cables is required. 43

Instrument cable tray fire protection 30 minute hydrocarbon fire protection a b c d e f Cable tray containing instrument control cables. Banding strap at 150mm centres used to support mesh lining on top of open trays. Mesh lining used to prevent cable tray wrap from slumping on top of tray. Stainless steel banding straps minimum 12mm wide installed at 40mm from the edge of each cable tray wrap piece with one strap placed in the centre. If 1220mm wide cable tray wrap is being installed, use a maximum spacing of 250mm between the band straps. The bands must be tightened so as to securely hold the cable tray wrap to the tray, but not so tight as to cut it. FireMaster cable tray wrap 50mm thick supplied in widths of 610mm or 1220mm. Installed in one layer with overlapped joints of 75mm. Additional bands may be placed as needed such as at elbows and 90 degree bends to assure tight joints. Overlap of 75mm between adjacent cable tray wrap pieces. a b c d e f 44

Instrument cable tray fire protection with optional weather proofing system a b c d e f Cable tray containing instrument control cables. Banding strap at 150mm centres used to support mesh lining on top of open trays. Mesh lining used to prevent cable tray wrap from slumping on top of tray. Stainless steel banding straps minimum 12mm wide installed at 40mm from the edge of each cable tray wrap piece with one strap placed in the centre. If 1220mm wide cable tray wrap is being installed, use a maximum spacing of 250mm between the band straps. The bands must be tightened so as to securely hold the cable tray wrap to the tray, but not so tight as to cut it. FireMaster cable tray wrap 50mm thick supplied in widths of 610mm or 1220mm. Installed in one layer with overlapped joints of 75mm. Corrugated aluminium sheeting 0.6mm thick for weather protection. a b c d e f 45

Cable tray fire protection fire testing and certification Instrument cable tray fire protection has several purposes. These are: Maintain cable function in a fire Prevent corrosive/toxic gas emission when cable burns Protect fire fighters Aid evacuation Minimise long-term damage to cable facilities 1200 1100 1000 900 800 ASTM E1529 and UL 1709 Fire Curves Specified Heat Fluxes ASTM E1725-95 Standard Test Methods for Fire Tests of Fire Resistive Barrier Systems for Electrical System Components is designed to measure and describe the response of electrical system materials, products or assemblies to heat or flame under controlled conditions. This test can be carried out using either cellulosic or hydrocarbon fire curves (ASTM E119 and E1529 respectively). Temperature ( C) 700 600 500 400 ASTM E1529: 158 kw/m² heat flux (±8 kw/m²) UL 1709: 204 kw/m² heat flux (±16 lw/m²) API 2218 Fire Proofing Practices in Petroleum and Petrochemical Processing Plants references ASTM E1725-95 test method and states that for applicability to petroleum and petrochemical processing plants, the fire test should be carried out using a hydrocarbon fire temperature/time curve. API 2218 considers the ASTM E1529 and UL 1709 hydrocarbon fire curves to be functionally equivalent. These fire curves are similar. The ASTM E1529 curve is slightly higher in temperature than UL 1709 and specifies a heat flux taken from measurements of hydrocarbon pool fires (see Appendix 1 of ASTM E1529 for further information). The two fire curves are shown opposite right. 300 200 100 0 0 10 20 30 40 50 Time in minutes UL 1709 Curve ASTM E1529 Curve 60 70 The ASTM E1529 test method has stringent requirements for performance of cable tray fire insulation systems. The key features of the test are: The test is run at positive pressure over at least ½ the test assembly Thermocouples are arranged in sets, fixed into the tray every 150mm on both rails of the cable tray, and every 150mm on a bare copper wire centered in the tray The cable tray is intended to be run empty of cables, providing approval for 0% to 100% cable loading Failure is determined when one thermocouple set reaches an average temperature rise of 250 F, (121 C) or any single thermocouple reaches 325 F (163 C) 46

Cable tray fire protection fire testing and certification Assessing the performance of cable tray fire insulation systems using cable temperature versus circuit integrity ASTM E1725 uses cable tray temperature as the failure criterion because circuit integrity has been shown to be unreliable as an indicator of failure of a cable. This is the result of research that indicated cables believed to be of identical composition and rating had different functional failure temperatures. This means that circuit integrity failure cannot be assumed to reliably occur at the same time point in a fire. Therefore, it is more reliable to establish a maximum temperature beyond which any cable can be considered to be at risk of failure. Using cable temperature as the failure criterion ensures that the maximum temperature at which functionality of any cable can be assumed to be maintained is not exceeded, even if circuit integrity can be maintained by the sample cable used in the fire test. Furthermore, the measurement of tray rather than cable temperature, with an empty tray, allows any cable loading to be used in practice. Certification approval The FireMaster instrument control cable tray system is Factory Mutual Approved for 30 minute hydrocarbon fire protection of instrument control cable trays in accordance with ASTM E1725-95 method using the ASTM E1529 hydrocarbon fire curve. The FM Approval is valid for manufacture of FireMaster cable tray wrap at a number of Morgan Thermal Ceramics factories worldwide. 47