Operating Instructions. For. Alarm Control Module. Model SSR 500

Similar documents
Power Supply Display Module PSDM. Installation and Operation Manual

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Motogard. Over Temperature Protection System. Installation Instructions

DTA. Motor thermistor relay. Benefits. Description

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

MBCE-110/230FR Flame Sensor Module

Model 4001 Series Single Channel Controller

DTA04. Motor thermistor relay. Benefits. Description

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

SAFETY INFORMATION AND WARNINGS

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Honeywell ENERGY SAVINGS KIT

Instruction Manual August sitrans CU 02

Global Water Instrumentation, Inc.

Operating Instructions

ph COOLING TOWER CONTROLLER

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Table of Contents. Protective Relays

RELEASE DEVICE CONTROLS

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Model 17A00 Expansion Enclosure

FEC400 Series. Installation Manual

M15051) INSTRUCTION MANUAL

MBCE-110/230FR Flame Sensor Module

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Greentrol Automation, Inc.

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

ISIS SAFETY SYSTEM Installation guide

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Battery Fail Monitoring System

Bulletin 1608N MiniDySC Dynamic Sag Corrector

MANUAL RESET ALARM RELEASE

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

CR Series Command Relays

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INSTALLATION INSTRUCTIONS

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Process Alarm Module RTA 421

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

7800 SERIES RM7888A Relay Module

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Sitron s CF Line of Flow Switch Monitors

Water Detection Controllers

Flame Rod Manual. Publication Rev A

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Warranty Registration

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

SET-2000 Hi Level/Oil

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

ACS-30-EU-EMDR- 10-MOD

INSTALLATION INSTRUCTIONS

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

GL-CO-RFG Channel Gas Leak Alarm System

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

HD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair.

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

MODEL B2 INSTALLATION MANUAL

ESRB and ESRN Installation & Safety Instructions

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

DISPOSER CONTROL CENTER

Q7800H Integrated Burner Control Subpanel

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

OilSET-1000 (12 VDC)

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

MANUAL RESET ALARM RELEASE BOX

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

MTRA-FSP Level Control Relay. Installation & Operation Manual

Instruction Manual December 2001 ENACOCU02

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Electric Release Panel Wiring Tips

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Transcription:

SSR 500 LEVEL CONTROL RELAY MODULE Operating Instructions For Alarm Control Module Model SSR 500 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7

1. Note Please read and take note of these operating instructions before unpacking and commissioning. The instruments may only be used, maintained and installed by qualified personal familiar with the operating instructions and the applicable health and safety requirements. 2. Contents 1. Note 2. Contents 3. Specific Applications 4. Operating Principle 5. Instrument Inspection 6. Mechanical Installation 7. Technical Specifications 8. Electrical Connections 9. Start Up 10. Troubleshooting 11. Maintenance 3. Specific Applications The Alarm Control Module has been designed for use in level alarm applications. The module consists of a transformer, control circuit and output relays The SSR is an switch type control module with two SPST relay contacts output. Inputs should be dry (potential free) contacts, for example reed switch contacts from a float type level detector. The module generates 24VDC to detect input switch closure; the current is limited to 20 ma on the inputs, in order to protect the level switches. In addition the module has built in time delay on the inputs, which avoids false triggering due to switch bounce or nuisance tripping from process vibration, waves or bubbles. 4. Operating Principles The module is designed to provide detection of two levels in a process tank and controls indicate a high and low level alarm. The multifunctional relays of the SSR 500 series are contact protection relays to connect to double contacts. The increase in switching safety and the switching capacity of the reed switch has increased when used with the SSR 500. Multifunctional relays are absolutely recommended for use with reed switches immersed in oil. SSR Operation Instructions Rev. 1 Jan 01 Page 2/7

5. Instrument Instructions The instruments are thoroughly inspected by the factory prior to shipment and sent in perfect condition. Should any damage to the device be visible, we recommend a thorough inspection of the delivery packing. In case of damage please inform your parcel service/forwarding agent immediately, since they are responsible for damages incurred during transit. Scope of delivery: Level Control Alarm Module Operation Manual 6. Mechanical Installation The relay module enclosure is rated IP 20 (approx. equivalent to NEMA 1), which is intended for use in dry, dust free environment. If the relay module will be located in harsh, wet or dusty environments, the user should mount in an appropriate enclosure to protect the device. For example - NEMA 4X electrical enclosure. The relay module can be mounted on to a standard DIN mounting rail, according to DIN 46277, EN50022. The device snaps on to the DIN rail and can be removed from the rail by releasing the spring-loaded clip, located on the bottom of the device. Drawing Pending Operation Instructions Rev. 1 Jan 01 Page 3/7

7. Technical Specifications Preliminary Technical Data Sheet Instrument Type Electromechanical Contact Protection Relay Model SSR 500 Housing Size 75mm x 50mm x 100mm Housing Material Polyamid 6.6 Supply Voltage 115 VAC +/- 10% 50 60 Hz Power Consumption 5 VA (typical) Control Voltage 24 VDC Control Current 20 Ma Input Impedance 3300 Ohm, 100 nf +/- 20% Maximum Contact ON Impedance 4700 Ohm, 47 nf at inputs Delay Period (initiating) 10 ms Delay Period (dropping) 20ms Output 2 SPDT relay contact Permissible Load 250 VAC / 8A resistive / 1840 VA Temperature range -20 deg. C to 60 deg. C Type of protection IP 20 Operation Instructions Rev. 1 Jan 01 Page 4/7

8. Electrical Connection ATTENTION: Ensure that the voltage levels of your supply system are in agreement with the voltage levels given on the Type Label of the device. Make sure that the electric supply lines are not active during connection to this device. Improper wiring can lead to damage of this device as well as injury to the user. Make sure that installation; wiring and circuit protection are in accordance with all local electrical codes. Make sure the supply circuit provides adequate fuse or circuit breaker protection that is in accordance with the circuits current rating. Make sure that a alarm contacts ratings do not exceed the SSR 500 Level Control s relay rating. Electrical connections to the relay module are made by - connecting the wires to the numbered screw terminals. Wiring is per attached drawings and specifications. Wiring Table Terminal # Description Function A1 Mains Connection Connect to 115 VAC Supply A2 Mains Connection Connect to 115 VAC Supply 22, 23 High Alarm Connect top switch direct to 22 and 23 12, 13 Low Alarm Connect bottom switch direct to 12 and 13 52 Common High Output high alarm common 51 N/C High Output N/C high alarm 53 N/O High Output N/O high alarm 42 Common Low Connect low alarm common 41 N/C Low Output N/C low 43 N/O Low Output N/O low 82 & 81 24 VDC Excitation Sensor Supply Maximum 20 ma not used in standard mode Operation Instructions Rev. 1 Jan 01 Page 5/7

Wiring Diagram SSR 1000 ALARM CONTROL RELAY MODULE 9. Start-Up Ensure that all wiring to the Level Control Module is correctly installed and the level switches are installed and functioning correctly. The Relay Module is now ready for operation and the supply power to the level control circuit can be applied. In the alarm mode of operation, the relay should operate in accordance with the description in section 4. Operating Principals. 10. Troubleshooting The relay does not operate: Check the mains voltage is applied to the L and N terminals on the module. Check that there is 24 VDC across terminals 82 and 81. If mains voltage is applied and no 24 Volts is measured across 82 and 81 the module may be defective. Check level switch operation and cabling from the tank location to the module. Temporarily remove the switch inputs from the module and simulate level switch closure using jumper wires across input terminals. When simulating level switch closures, the relay does not activate, the relay may be faulty. If the relay activates but does not close the relays, the output wiring circuit may be faulty. 11. Maintenance The Level Relay Module requires absolutely no maintenance. Depending on the type of level sensors used and the process conditions, maintenance to the sensors may be required. Verify and follow maintenance procedures according to the sensor maintenance manual. Verify and follow maintenance procedures according to the pump or solenoid manufacturer s maintenance manual. There are no user serviceable parts inside the SSR 1000 module. If repair is required please contact your local distributor to return for repair. Operation Instructions Rev. 1 Jan 01 Page 6/7

Your Distributor Is Operation Instructions Rev. 1 Jan 01 Page 7/7 Specifications are subject to c hange