Assuring Reliability of Compressors Using HFC Refrigerants By Hideto NAKAO Mitsubishi Electric Corporation Amagasaki-City, Hyogo, Japan

Similar documents
Selection of a refrigeration oil for the R32 refrigerant and evaluation of the compressor reliability

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Tribology Characteristics of HFO and HC Refrigerants with Immiscible Oils - Effect of Refrigerant with Unsaturated Bond -

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Chapter 2. Alternatives to HCFCs and their Characteristics

Evaluation of HFC Rotary Compressor and System (Improvement of Lubricating Ability and Capillary Tube Clogging)

Scroll Chillers Transition from HCFC-22 to HFCs

Compressor Durability Tests and System Tests with AB and HFCs

Development of centrifugal chiller and heat pump using low GWP refrigerant

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Reliability Study of Compressor for Room Air Conditioners Using HFC Based Refrigerant

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

R-407A R-448A R-449A

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21

Development of centrifugal chiller and heat pump using low GWP refrigerant

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

Refrigerants and lubricants

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Development of HFC-134a Compressor for Domestic Refrigerator

CHAPTER 1 INTRODUCTION

March 10, 2016 San Joaquin Valley RETA Meeting

A study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Air Conditioning Filter

A Performance-Enhancing Additive for Vapor- Compression Heat Pumps: Additional Test Results

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Refrigerant Transfer and Compressor Damage

APPLICATION OF HYDROCARBON REFRIGERANTS IN LOW TEMPERATURE CASCADE SYSTEMS

The Essentials Of Working With R-410A

Comparison of the High Side vs

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

Transcritical CO2 Bottle Cooler Development

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

The natural solution for domestic refrigeration

Study of R161 Refrigerant for Residential Airconditioning

Refrigeration Systems and Accessories

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Evaluation of HCFC Alternative Refrigerants

Oil Return Measurements In A Unitary Split System Air Conditioner Using Different Refrigerant Mixtures

High Efficiency R-134a Compressor for Domestic Refrigerator

System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller

An Experimental Investigation on Flow Characteristics of Refrigeration/Oil Mixture in Vertical Upward Flow

Harold Ag & Mobile Products

AUTOFROST Technical Discussions

How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action.

EN aquatech.piovan.com

Purdue e-pubs. Purdue University. T. Hamada Mitsubishi Heavy Industries Ltd. N. Nishiura Mitsubishi Heavy Industries Ltd.

Refrigeration & Air Conditioning Experiment No. 5. Experiment No. 5

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Diagnosing Troubles in Refrigeration Units with Screw Compressors

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Torad Rotary Spool Compressor

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Energy Saving & Eco-Friendly Refrigerant

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

DAIKIN's Experience in the production with R32

FACT SHEET 9 Large Air-Conditioning (air-to-air)

High-efficiency Turbo Chiller (NART Series)

VCR SYSTEM USING R-600a/ POE OIL/MINERAL OIL/NANO-SiO 2 AS WORKING FLUID: AN EXPERIMENTAL INVESTIGATION

Midea VFD Centrifugal Chiller Technology

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

Technical Development Program

REFRIGERANT CHANGEOVER

Gary Parker Refrigerants Product Manager

Heat Transfer Coefficient and Pressure Drop for Forced Convection Boiling and Condensation of HFC134a

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Danfoss scroll compressors CXH140 - single and manifold installation

HFCs or the Old Refrigerants - what is the best Choice?

Transcription:

Assuring Reliability of Compressors Using HFC Refrigerants By Hideto NAKAO Mitsubishi Electric Corporation Amagasaki-City, Hyogo, Japan Abstract In Japan, the refrigerant used in room air-conditioners has been changed from HCFC-22 (R-22) to R-410A, a blend of HFC-32 and HFC-125 (50/50 vt%), in order to protect the ozone layer. Generally, the miscibility between the refrigerant and refrigeration oil must be assured, because the oil needs to return to the compressor from the refrigeration cycle and lubricate the sliding parts. Alternative oils with good miscibility with HFCs have been developed, because mineral oil, the primary oil used with R-22, has low miscibility with HFC. The chlorine atoms which make up R-22 create excellent extreme pressure performance on the sliding parts in compressors; however, they are the cause of the depletion of the ozone layer. Because HFC does not have any chlorine atoms in its molecular structure, it is essential to prevent the sliding parts from scuffing (seizing) and wearing when using HFC in the compressors,. Therefore, anti-wear additives are added to the oils, and alternative sliding materials and surface treatments have been used in rotary, swing and scroll compressors which are fitted to room air-conditioners in Japan. The problems in using HFC in swing compressors are similar to those for rotary compressors. This paper describes the technical problems of ensuring the reliability of rotary and scroll compressors using R-410A. Background Both rotary compressors and scroll compressors use HFC refrigerants. In Japan air-conditioners, including room air-conditioners, packaged air-conditioners and multi air-conditioners for buildings, and refrigeration machines all use HFC refrigerants. Description of Compressors Figure 1 presents the cross-section views of rotary compressor. The main sliding parts in a rotary compressor are the sliding bearings, located at the upper and lower ends of the cylinder and supporting the crankshaft, and the vane tip in the cylinder. The suction gas is compressed until reaching the required pressure in the cylinder and discharged to the inside of the shell and then discharged to the refrigeration cycle from the discharge port. The reliability of the sliding bearing is ensured by maintaining the viscosity of the oil mixed with the refrigerant and the film thickness under operating conditions. However, the vane tip contacts the outside surface of the rolling piston linearly and high contact pressure is loaded between the two parts and the outside surface of the rolling piston slides on the vane tip. Therefore, anti-wear technology is required for the vane tip. 1

Crankshaft Rot or St at or Upper bearing Oldham coupling Orbiting bearing Frame Suction port Sub bearing Discharge valve Discharge port Fixed scroll Orbiting scroll Thrust bearing Main bearing Rot or St at or Main shaft Cylinder Lower bearing Vane Orbiting scroll Oldham coupling Crankshaft Frame Rolling piston (Roller) Fig. 1 Cross-section view of rotary compressor Fig. 2 Cross-section view of scroll compressor Figure 2 presents the cross-section views of a scroll compressor. The main sliding parts in a scroll compressor are the main and sub bearings supporting the main shaft, the orbiting bearing supporting the orbiting scroll, the Oldham coupling converting the rotating motion of the main shaft to the orbiting motion of the orbiting scroll and the thrust bearing supporting the axial compression load of the orbiting scroll. The suction gas is compressed until reaching the required pressure in the spaces between the fixed scroll and the orbiting scroll and discharged to the refrigeration cycle from the discharge port. The reliability of the sliding bearing is ensured by maintaining the viscosity of the oil mixed with the refrigerant and the film thickness under operating conditions. However, especially the Oldham coupling reciprocates on the undersurface of the orbiting scroll and the top surface of the frame and the oil film is not able to form. Therefore anti-wear technology is also required in scroll compressors. Characteristics of Alternative Table 1 shows the characteristics of R-22 and R410-A. The chlorine atoms in R-22, form a chloride film on the sliding surfaces. The chloride film has extreme pressure performance. However, the operating pressure of R-410A is about half as high as Table 1 Characteristics of refrigerants Refrigerant HCFC HFC R-22 R-410A components ----- HFC32/125 (ratio, wt%) ----- (50/50) zeotropic /azeotropic single near azeotropic ODP 0.055 0 GWP (100 years) 1700 1700 condensation pressure, MPa (40 ) 1.53 2.41 2

that of R-22 and the pressure tightness of the shell needs to be enhanced when using R-410A. Because R-410A has the highest performance of HFC refrigerants, R-410A was selected as the replacement for R-22 in newly manufactured equipment. Mineral oil, the primary oil used with R-22, has low miscibility with HFCs; therefore, ester and ether oils, which are highly miscible with HFCs, have been developed. However, anti-wear additives must be added to these oils and new sliding materials and surface treatments must be used because HFCs do not have any chlorine atoms in their molecular structure to form a film on sliding surfaces. In addition, wear and scuffing of the sliding parts need to be prevented by anti-wear additives. When the atmospheric temperature is low in winter, the liquid refrigerant dissolves in the oils and the viscosities of ester and ether oils are lowered. Therefore, alkyl benzene which has low miscibility with HFC has been used. 1,2 Identifying the Appropriate Anti-Wear Additives for R-410A Figure 3 presents the relationship between the quantities of the anti-wear additives in the ester oil and the scuffing pressure of cast iron in a HFC atmosphere. 3 When the optimum quantities of additives are added to the ester oil, the scuffing pressure reaches the highest value. Figure 4 presents the wear amounts of the vane and rolling piston (roller) in the rotary compressors lubricated by R-22 and mineral oil, compared to R-410A and ether oils. 4 When surface treated high speed steel is used for the vane, the amount of wear of the roller is reduced. Figure 5 presents the wear depth of the sliding bearing material using R-410A and alkyl benzene compared to the wear depth of R-22 and mineral oil and R-410a and polyester oil. The wear depth for R-410A and alkyl benzene is lower than that using R-22 and mineral Relative roller wear quantity oil, or R410A and ester oil. 1 However, a special oil returning mechanism is needed in Scuffing Pressure[MPa 0 Ref Vane Roller Oil 250 200 150 100 50 TypeA TypeB 0 0 a 1 a 2 a 3 a 4 Quantity of anti-wear additives Quantity of EPA[wt.%] Fig. 3 Relationship between quantities of anti-wear additives and scuffing pressure Operating time : 1000hs Inverter frequency : 100Hz 2.0 1.0 R22 High speed steel Cast iron A Mine Carbon - Al Cast iron B R410A Fig. 4 Comparison of roller wear Surface treated high speed steel Cast iron C Ether 3

order to use alkyl benzene as the refrigeration oil for HFCs. 2 A wear reduction method is also needed for scroll compressors using HFCs. 5, 6 There is concern regarding the Oldham coupling wear in the scroll compressor. Figure 6 shows the result of a wear test using gray cast iron (FC250) and the Oldham coupling material. 6 An Oldham coupling made from sintered iron without surface treated is not able to reduce the amounts of wear. However, when sintered iron treated by steam treatment and gas nitro-carburizing, the amounts of wear are reduced. Oldham coupling material Gray cast iron Fig. 5 Wear depth of shaft after flooded-start test Fig. 6 Wear amounts of Oldham coupling Impact of Switch to Alternative The manufacturing costs increase when changing the refrigerant from HCFC to HFC because the refrigeration oils are changed from mineral oil to ester and ether oils, and surface treatments and alternative materials to be used for the sectional sliding parts and the pressure tightness of the shell needs to be enhanced. However, the performance of room air-conditioners using R-410A is better than those using R-22. In addition, the operational costs, namely electricity, are the same. References 1) Shin Sekiya, Yoshinori Shirafuji, Susumu Kawaguchi, Taro Kato, Takeshi Izawa: Alkylbenzenes for Split Air-Conditioners with R410A Part 1: Reliability Evaluation of Compressors, 1998 International Compressor Engineering Conference at Purdue (1998) 465. 2) Yoshihiro Sumida, Masahiro Nakayama, Sou Suzuki, Susumu Kawaguchi: Alkylbenzenes for Split Air-Conditioners with R410A Part 2: Oil Return Characteristics, 1998 International Compressor Engineering Conference at Purdue (1998) 471. 3) Hideto Nakao, Koei Matsukawa, Yoshinori Shirafuji, Shin Sekiya: The Effect of Water Contents of POE on Scuffing Characteristics, 2000 International Compressor Engineering Conference at Purdue (2000) 207. 4

4) Kazuaki Fujiwara, Kenzo Matsumoto, Takahiro Nishikawa, Takeshi Sato: Performance and Reliability Evaluation of Rotary Compressor for HFCs, The International Symposium on HCFC Alternative Refrigerants 98 (1998) 145. 5) Hideki Matsuura, Masahiro Minowa, Yukio Fudemato, Susumu Hiodoshi, Masaki Nomura: Evaluation of Refrigerant Oil for HFC Refrigerants and Selection of Sliding Materials, The International Symposium on HCFC Alternative Refrigerants 98 (1998) 423. 6) Yodhiyuki Futagami, Hideo Hirano, Mototaka Esumi, Hideto Oka, Hiroyuki Kawano, Keizo Nakajima: Development of the Materials for Sliding Part of the Compressor for HFC s, 1998 International Compressor Engineering Conference at Purdue (1998) 135. 5