READ AND SAVE THESE INSTRUCTIONS

Similar documents
1000 SERIES FLOW THROUGH POWER HUMIDIFIER 12-1/8 14-1/8

Read and Save These Instructions

INTELLIMIST Residential Atomizing Humidifier and Control

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

INTELLIMIST HUMIDIFIER

ASYSTAT625A Humidity Control

HE220, HE260 Humidifier Installation Kit

HE360 Humidifier Installation Kit

FLOW-THROUGH FURNACE HUMIDIFIER

HE120, HE160 Humidifier Installation Kit

Installation Instructions

TrueSTEAM. 1 Mount 2 Hang. 3 Plumb 4 Wire. As Easy as PROFESSIONAL INSTALLATION GUIDE

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

CUSTOMER SERVICE. Toll-free:

DS 2001 REVISED Humidifier Assembly and Instruction Manual

Duct Mount Atomizing Humidifier

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Automatic Digital Humidifier Control

Installation Instructions

Installation Instructions Owner s Manual

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

FLOW-THROUGH FURNACE HUMIDIFIER

Instant Hot Water Dispenser Owner s Manual

Operator: Save these instructions for future use!

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Model 1920/1920HPS/1920W Bottle Filler

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

Installation Instructions & Owner's Manual

LOW VOLTAGE CONTROL CIRCUIT WIRING

MX Series Indoor Modular Blowers ModuleFlex Electric or Hot Water Heat with available Variable-Speed High Efficiency ECM Motor

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

TrueDRY DR90 PROFESSIONAL INSTALLATION GUID OPTIONAL CONTROLS SOLD SEPARATELY

INSTALLATION, OPERATION AND MAINTENANCE

Duct Mount Rotating Drum Humidifier

Installation. Leveling

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Model 7611 Eye/Face Wash

INSTALLATION INSTRUCTIONS

Duct Mounted Atomizing Humidifier. Table of Contents

Steam Humidifier Fan Pack Installation & Maintenance Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

TECHNICAL MANUAL MBVC

G-100ES Duct Mount Humidifier

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

Owner s Manual. Humidifiers. For Models 350, 360, 400, 400M, 500, 500M, 600, 600M, 700 & 700M

Installation Instructions / Warranty

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

INSTALLATION INSTRUCTIONS Apartment Fan Coil

MD6-ES24VK. Installation, Operation, and Maintenance Manual

Installation Instructions / Warranty

Safety, Installation, and Operation Manual

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS MODELS 4000, 5000, 6000 & 7000 HUMIDIFIERS. Includes Safety, Operating and Maintenance Instructions

INSTALLATION. Glass Panel Doors (select models) CAUTION

INSTALLATION INSTRUCTIONS Fan Coils FEM4X, FSM4X, FSU4X, FXM4X

Installation Instructions WARNING WARNING. Variable Speed High Efficiency Blower Kit for Gas Furnace Applications 3. INSTALLATION

INSTALLATION INSTRUCTIONS

G-100ES Duct Mount Humidifier

Owner s Manual. For Models 350, 360, 400A, 500A, 500M, 600A, 600M, 700A & 700M. Includes Safety & Operating Instructions and Warranty Information

TECHNICAL GUIDE. Echelon MODELS: FC9T GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW TWO STAGE FURNACES UP TO 94% AFUE

Installation Instructions / Warranty

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Fan Coils FEM4X, FSM4X, FSU4X, FXM4X

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

W8703A Damper Interface Module

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Model 1730A Compact Dehumidifier Installation Instructions

HEAT HEAT HEAT COOL COOL

Owner s Guide. TrueIAQ Digital IAQ Control

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

Installation & Maintenance Instructions

HEALTHY CLIMATE HUMIDIFIER

Owner s Manual For Models 400, 500, 600 & 700

Serial No.: and Up OPERATING INSTRUCTIONS MODEL AR. STEAM GENERATORS CAUTIONS:

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS. The Best Cure For Dryness OWNER S MANUAL

F-LF AND F-PF SERIES

Model H1011.8/H1011.8HPS Water Cooler

Forteza Series Granite Kitchen Sink

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

MEGATRON MODEL TA, TA-LF

L A signature series TA T N E RE O, A L L A T S IN

model 1900 FEATURES & BENEFITS SPECIFICATIONS APPLICATIONS OPTIONS Bottle Filling Station

15" (38.1 CM) ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DE TABLE DE CUISSON ÉLECTRIQUE DE 15" (38,1 CM)

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON

Installation Instructions 36 Inch Refrigerator

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

WELLWORTH /HIGHLINE WITH PEACEKEEPER VITREOUS CHINA TOILET

nordica 36 ceiling fan

e Bath Fan with Light User s Guide

A/C-HEATER SYSTEM - MANUAL

Transcription:

OPENING LEAANE ABOVE THIS LINE PEFEED: 2 1/2 INH. MINIMUM: 1 1/2 INH. UT SHEETMETAL ALONG THIS LINE ENTELINE Fresh Indoor Air Quality EAD AND SAVE THESE INSTUTIONS INSTALLE: PLEASE FILL OUT AND MAIL GUAANTEE AD AFTE INSTALLATION IS OMPLETE. LEAVE INSTALLATION INSTUTIONS WITH HOME OWNE SL-16 PEAUTION: The installer should be an experienced service technician. Disconnect electrical power before beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures exceed 200 degrees F. When wiring into a multi-speed blower circuit see Step 7D. INSTALLATION: The humidifier may be mounted with the 6" outlet to the right or left by reversing the position of the Bypass over. The humidifier may be mounted on the warm or return air plenum with equal efficiency. See Typical Installations below. ADDITIONAL MATEIALS THAT MAY BE NESSESAY: 1. 1/4" diameter copper or plastic water supply tubing (G.F. #747-38 suggested) 2. 5/8" diameter drain tubing (G.F. #1099-16 suggested) 3. 3/4" O.D. drain tube clamp (G.F. #P-163 suggested) 4. 6" diameter galvanized by-pass pipe 5. 6" diameter galvanized elbow 6. 6" diameter galvanized damper 7. 6" diameter collar 8. wire, two-conductor #18 or heavier (G.F. #727-48 suggested) 9. transformer 120V, 60HZ primary 24V, 10VA or greater secondary (G.F. #727-58 suggested) 10. air pressure switch (G.F. Model #12500 suggested) ETUN AI 11. current sensing relay (G.F. Model #GA50 suggested) GENEALAire A SEIES HIGH EFFIIENY AI LEANE DAIN DAIN ETUN AI ETUN AI HIGH BOY OUNTE-FLOW LOW BOY DAIN 1 1 2 UT TEMPLATE ALONG THIS LINE UT TEMPLATE ALONG THIS LINE 2 Select location on vertical surface of warm or return air plenum for mounting humidifier and tape mounting template. Make sure the template is level. Do not install humidifier or 6" bypass pipe where the blanked off ends of a cooling coil will restrict air flow to the humidifier. Extend horizontal centerline from template to the adjacent plenum. Scribe 6 circle 10 to 15 from side of humidifier, on cabinet centerline. 4 4 3 OPPE TUBING Start the three initial mounting screws. Mount humidifier cabinet in level position and tighten screws. Install six additional screws at top and sides of cabinet. PLASTI TUBING ut 6 hole and install connecting collar, 6 elbow and by-pass pipe (not supplied). USE UNIMPED END IN IDIFIE ABINET. onnect by-pass pipe to collar and humidifier cabinet. Using holes at top and bottom of humidifier bypass opening, screw by-pass pipe to humidifier cabinet. Install bypass cover by placing the tab of the bypass cover marked "TOP" behind the top flange of the humidifier cabinet, push up on the bottom clip until it clears the opening of the humidifier cabinet then push in on the bottom of the bypass cover. NOTE: If furnace is used for summer cooling, install inline damper in by-pass pipe. Mount the self tapping saddle valve on either a cold or a hot water pipe. A side or top mount is best to avoid clogging from pipe sediment. onnect 1/4 O.D. tubing to the saddle valve. opper tubing requires a brass compression nut and brass sleeve. Plastic tubing requires a brass insert inside the tubing, a plastic sleeve on the outside with a brass compression nut. NOTE: DO NOT USE PLASTI TUBING ON HOT WATE O IN ONTAT WITH ANY HOT PLENUM SUFAE O DUT. INSTALLATION OF THIS SADDLE VALVE MUST MEET O EXEED LOAL ODES AND ODINANES.

SADDLE VALVE INSTALLATION INSTUTIONS opper Pipe 1. etract piercing pin into valve body by turning handle counterclockwise. 2. Screw valve body into upper bracket and tighten. 3. Place rubber gasket over piercing pin. 4. Assemble saddle valve over copper pipe using enclosed screws, nuts and lower bracket. 5. Tighten screws evenly and firmly. Brackets should be parallel. 6. omplete compression connection to saddle valve outlet. 7. Turn handle clockwise to pierce tubing and close saddle valve. 8. Turn handle counterclockwise to open saddle valve, leave open for Steel, Brass or Hard Plastic Pipe 1. Shut off water supply and drain pipe. 2. Turn handle clockwise to expose piercing pin and close saddle valve. 3. Place rubber gasket over piercing pin. 4. Drill 1/8" hole in pipe using a hand crank drill to avoid shock hazard. 5. Assemble saddle valve over steel, brass or hard plastic pipe using enclosed screws, nuts and lower bracket. 6. Tighten screws evenly and firmly. Brackets should be parallel. 7. omplete compression connection to saddle valve outlet. 8. Turn handle counterclockwise to open saddle valve, leave open for Threaded Pipe Fittings 1. Turn handle clockwise to expose piercing pin and close saddle valve. 2. Seal valve body threads using pipe tape or sealant. 3. Install valve into 1/8" NPT fitting. 4. omplete compression connection to saddle valve outlet. 5. Turn handle counterclockwise to open saddle valve, leave open for 6 5 OPPE TUBING PLASTI TUBING Attach solenoid valve into top of humidifier cover using 1/4 turn rotation. If using copper tube, leave two coils of tube next to cabinet to allow cover movement for changing pad. If using plastic tube, anchor tube 2 inches below humidifier and leave some slack. This will allow full cover movement. Loosen the fitting nut on the solenoid valve 1/2 turn. Push the 1/4" O.D. tubing straight into fitting until it bottoms on the fitting's shoulder. TIGHTEN NUT BY HAND. Additional tightening is not required. DO NOT OVETIGHTEN NUT AS THE THEADS WILL STIP AND THE FITTING WILL NOT FUNTION POPELY. DO NOT USE PLASTI TUBING IN ONTAT WITH ANY HOT PLENUM SUFAE O DUT. 2 6 TOP DUT IDISTAT FLUSH TEMPLATE 1. EMOVE ADHESIVE BAKING AND APPLY TO THE DUT IN THE SELETED LOATION. 2. AUATELY ENTE PUNH ALL S. 3. DILL FOU S SIZE 3/32", DILL NO. 42 O 2 mm. 4. DILL OTHE S WITH 1/8" O 3 mm DILL. 5. BEAK METAL FOM GOUP OF S, AND UT OUT ON SOLID LINE WITH SHEAS. HAUT GABAIT DE MONTAGE DE L'IDISTAT ENASTÉ DANS LE ONDUIT 1. ENLEVEZ LE SUPPOT ADHÉSIF ET POSEZ SU LE ONDUIT À L'ENDOIT HOISI. 2. ENTEZ TOUS LES TOUS AU POINTEAU AVE PÉISION. 3. PEEZ QUATE TOUS DE MONTAGE DE 3/32 PO (MÈHE Nº 42 OU DE 2 mm). 4. PEEZ LES AUTES TOUS AVE UNE MÈHE DE 1/8 PO OU DE 3 mm. 5. DÉTAHEZ LE MÉTAL DU GOUPE DE TOUS ET DÉOUPEZ SU LA LIGNE PLEINE AU MOYEN DE ISAILLES. UT ON LINE OUPE SU LA LIGNE TEMPLATE NO. 12807 EV. B MATIE N o 12807 ON THE ETUN AI DUT Do not install the humidistat on the warm air duct. 1. Locate the humidistat at least 24" upstream of the humidifier or bypass on the return air duct. Avoid areas of direct radiation like secondary heat exchangers in the fan compartment. 2. Place template using level. ut sensor hole as shown on template. Drill four 3/32 holes as shown. 3. emove the housing from the base by prying with a small screwdriver at the notch in the side of the housing. 4. Place the outer part of the foam gasket on the humidistat base and mount the base with four screws. Low voltage wire may enter the humidistat under the foam seal. 5. onnect wires to screw terminals on the control assembly as shown in wiring diagram. eplace housing. WALL INSTUTIONS 1. hose a location for the humidistat about five feet above the floor on an inside wall with average room temperature and humidity conditions. 2. Drill a small hole in the wall and run low voltage wiring to the location chosen. Pull about 6 of wire through the hole. Plug the opening to prevent drafts from affecting the humidistat operation. 3. emove the housing from the base by prying with a small screwdriver at the notch in the side of the housing. 4. Mount the base horizontally over the wires using level. Attach directly to the wall, using four screws provided. 5. onnect wires to screw terminals on the control assembly as shown in wiring diagram. eplace housing.

7 A N A L FUNAE WIE JUMPE ONTOL BOAD 24v. W 60Y. 7A A N A L NO WIE JUMPE 12500 AI PESSUE SWITH ON-OFF SWITH 727-58 24 V. TANSFOME L2 60Y. L1 7B FUNAE GA50 UENT SENSING ELAY OMMON LEAD HI LO MULTI SPEED BLOWE MOTO A N A L WIE JUMPE ON-OFF SWITH 727-58 24 V. TANSFOME N 60Y. W 24v. 60Y. FUNAE BOAD 7 A N A L WIE JUMPE ON-OFF SWITH 727-58 24 V. TANSFOME 60Y. 7D IDISTAT FUNAE ONTOL BOAD 24v. 60Y. 7E IDISTAT NO 12500 AI PESSUE SWITH ON-OFF SWITH 24 V. TANSFOME L2 60Y. L1 7F FUNAE IDISTAT 24 V. TANSFOME ON-OFF SWITH FUNAE BOAD 60Y. A EA 7G 24 V. TANSFOME IDISTAT ON-OFF SWITH GA50 UENT SENSING ELAY OMMON LEAD 60Y. HI LO MULTI SPEED BLOWE MOTO 7H 7A-7D Electronic Humidistat 7A - To furnace control board 24 volts 7B - To constant power using 24V transformer and pressure switch 7 - To furnace control board 115 volts with 24V transformer 7D - To constant power using 24V relay and current sensing relay 7E-7H Manual Humidistat 7E - To furnace control board 24 volts 7F - To constant power using 24V transformer and pressure switch 7G - To furnace control board 115 volts with 24V transformer 7H - To constant power using 24V relay and current sensing relay 8 9 emove plastic bag from 990-13 evaporator pad, replace 16-4 distributor trough and close 16-2 cover. Turn on water supply and check operation of humidifier. Set humidistat to a demand setting. With the furnace off, the solenoid valve should be closed. Start the furnace, the solenoid valve should open when the blower or burner circuit is energized. heck flow of water through distributor trough and evaporator pad. The solenoid valve will supply approximately 3.5 GPH of water at a line water pressure of 60 psi. Leave humidistat set at the recommended setting. onnect drain hose to 5/8" spout on humidifier cabinet using a 3/4" hose clamp. un 5/8" I.D. hose to suitable drain such as floor drain, sewer or laundry sink. Be sure hose has continuous slope and is not kinked at any point.

HOW THE IDIFIE WOKS The operating principle of the humidifier is based on the most efficient and economical means of evaporating water to the air. The humidifier uses only five watts of electrical power during operation, less than the smallest household light bulb. The heat necessary for evaporating water is produced by the furnace. The water supply to the humidifier is controlled by the electric solenoid valve. The humidistat connected in series with the solenoid provides low voltage control of the humidifier. The humidistat has a SPST switch and is designed for wall mounting in the living area or surface mounting on the return air duct. ANGE: 10% to 60% H ELETIAL ATING: 24 VA / 60 Hz. DO NOT SET ELATIVE IDITY TOO HIGH DUING OLD WEATHE. EXESSIVE IDITY MAY AUSE ONDENSATION ON WINDOWS O IN WALLS. EFE TO EOMMENDED SETTINGS ON IDISTAT. Water flows through a strainer, is metered through an orifice to provide the proper amount of water, and is supplied to the evaporator pad by the distributor trough. Approximately 200 FM of air is by-passed from the warm air plenum through the humidifier and returned to the cold air plenum. Moisture is evaporated to the air passing through the evaporator pad. Minerals are not blown into the air stream as occurs in atomizing humidifiers; they are left on the evaporator pad where a high percentage is carried off with the waste water. When the humidifier is installed and operating, no adjustments are necessary other than setting the control knob on the humidistat to the desired level of humidification. To turn the humidifier off, close water supply valve, switch electrical power off and turn humidistat off. If furnace is used for summer cooling or ventilating close inline air damper if installed.. AT OUTSIDE TEMPEATUE EOMMENDED SETTING -20 F -29 15% -10 F -23 20% 0 F -18 25% +10 F -29 30% +20 F - 7 35% +30 F - 1 40% AE AND MAINTENANE PATS LIST FO IDIFIE Your Humidifier is engineered to give helpful and trouble-free humidification. For maximum efficiency the following cleaning procedures should be carried out at the end of each heating season: 1. Turn off water supply and electrical power to humidifier. 2. Open humidifier cover, remove trough and evaporator pad. If water line prevents cover opening disconnect water line from solenoid valve. lean excessive mineral deposits from the distributor trough, humidifier cover and humidifier cabinet. A solution of 1/2 vinegar & 1/2 water will help loosen mineral deposits. 3. If the evaporator pad has excessive mineral deposits, replace with a new 990-13 evaporator pad. Install trough and replace cover. 4. In heavy mineral areas or if the solenoid valve fails to function disconnect the 1/4 water supply line from the solenoid valve. arefully pull the filter from the solenoid valve. lean the mineral deposits from all parts. If the orificebeyond the filter is clogged, it may be opened by inserting a small needle. einsert the filter into the solenoid valve. 5. econnect the 1/4 water line to the solenoid valve if necessary. Tighten nut by hand, additional tightening is not required. DO NOT OVETIGHTEN NUT AS THE THEADS WILL STIP AND THE FITTING WILL NOT FUNTION POPELY. Turn on the water supply and check all points for leakage. The operation of the unit may be checked by starting the furnace. The humidifier operates only when the furnace blower is running or the burner circuit is energized. The humidifier is now ready for operation. 6. During the summer, turn off water supply and electrical power to humidifier. lose inline air damper if installed. PAT #16-4 DISTIBUTO TOUGH PAT #990-13 EVAPOATO PAD PAT #16-1 IDIFIE ABINET PAT #16-5 OVE- BYPASS opyright 2012 GENEAL FILTES, IN. All ights eserved PATS NOT SHOWN: 800UST SADDLE VALVE IDISTAT ASSY. PAT #16-2 OVE PAT #16-20 SOLENOID VALVE ASS'Y PAT #16-12 STAINE SEEN PAT #P-236 SOLENOID FITTING HADWAE

PATS LIST FO IDIFIE LIMITED WAANTY This humidifier, if properly registered by the return of the warranty registration card to the manufacturer, is warranted to the consumer against defects in materials and workmanship for a period of ten years from the date of installation. Evaporator pads, water strainers or metering orifices are not covered by this limited warranty or any other warranties. Any other defective parts will be repaired without charge except for removal, reinstallation and transportation costs. To obtain repair service under this limited warranty, the consumer must send the defective part or the complete humidifier to the manufacturer. THEE AE NO EXPESS WAANTIES OVEING THIS IDIFIE OTHE THAN AS SET FOTH ABOVE, THE IMPLIED WAANTIES OF MEHANTABILITY AND FITNESS FO A PATIULA PUPOSE AE EXPESSLY EXLUDED. THE MANUFATUE ASSUMES NO LIABILITY IN ONNETION WITH THE INSTALLATION O USE OF THIS PODUT, EXEPT AS STATED IN THIS LIMITED WAANTY. THE MANUFATUE WILL IN NO EVENT BE LIABLE FO INIDENTAL O ONSEQUENTIAL DAMAGES. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow either limitations on implied warranties, or exclusions from incidental or consequential damages, so the above exclusion and limitation may not apply to you. Any questions pertaining to this limited warranty should be addressed to the manufacturer. (U.S.A.: The manufacturer has elected not to make available the informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.) TEHNIAL SUPPOT USA USTOMES General Filters, Inc. 43800 Grand iver Ave. Novi, MI 48375 www.generalaire.com Engineering@generalfilters.com Toll Free (866) 476-5101 ANADIAN USTOMES anadian General Filters, Ltd. 400 Midwest d. Toronto, ON M1P3A9 anada www.gfproducts.com Sales@cgfproducts.com Tel. (416) 757-3691 WAANTY EGISTATION You may register online at www.generalaire.com or mail form below Product Information: Serial Number: Model: Install Date: Month Day Year Owner Information: Name: Address: Address 2: ity: State: Zip ode: Phone: Email: ontractor Information: ontractor Name: Address: Address 2: ity: State: Zip ode: ontractor Phone: ontractor Email: Fresh Indoor Air Quality Mail Form To: General Filters, Inc Attn: Warranty Dept. 43800 Grand iver Ave. Novi, MI 48375 cut along dashed line cut along dashed line