A New Sucker Rod Coupling Material: An Economical Solution for Downhole Wear in Deviated Unconventional Wells

Similar documents
Steel Sucker Rod Fatigue Testing Update on Phase I

Experience Rod Pumping Deviated CBM Wells

Pumping Unit Gear Reducer Failures

11 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 15-18, 2015

Complete Stress Analysis of Sucker- Rod Pumping Installations

Runtimes for Deviated Rod Pump Wells in the Fruitland Coal Formation

A Case for Developing a Wear Model for Sucker Rod System Design

Hollow Sucker Rods: Development and applications in Beam Pumping

Modified Everitt-Jennings (MEJ) Method and the Gibbs Method: Downhole Card Comparison

Design Your Rod String to Unseat the Pump But NOT Overload the System

Sucker Rod Pump Handling and Rig Crew Safety

Double String Pumping Systems *Patent Pending Dennis R. Wilson, Advisor, Artificial Lift Engineering ConocoPhillips, Lower 48, San Juan Business Unit

Improving the Reliability & Maintenance Costs of Hydraulically Actuated Sucker Rod Pumping Systems

System Design & Diagnostic Analysis of Group 2 Systems

Partial History of the Industry

Update on Sandia Downhole Dynamometer Testing

Quick Rod (QROD) String Design Tools

Validating Vertical-Hole Diagnostic Models with Measured Sandia Data

Design of Sucker Rod Systems

Development of a High Pressure Gas Gun for H 2 S and CO 2 Service

Downhole Dynamometer Card Validation Method

Rod String Design Software Simulation of Sandia Downhole Load Cell Wells

Pump Stroke Optimization: A Better Way

Recording Dynagraph on Bent / Misaligned Polished rod.

Horizontal Well Downhole Dynamometer Data Acquisition

Enhance Plunger Lift While Reducing CAPEX and OPEX

Interactive 3D Wellbore Viewer

Sucker Rod System Analyst

The Horizontal Rod Pumped Well s Ultimate Production System

UNDERSTANDING, ECONOMIC ANALYSIS OF & EFFICIENTLY MITIGATING DOWNHOLE FAILURES

Casing Gas Separator: A New Gas Separation Technology

Ventura Field Rod Well Systems

Comparing & Validating Deviation Surveys

Mitigate slug flow to increase the maximum rod pumping rate and allow earlier transition to rod pumping

Regulatory Roundup and Automation Scott Jackson Regional Sales Manager Mid Continent OleumTechitle

Understanding Hazardous Locations Concepts

Horizontal Well Downhole Dynamometer Data Acquisition: Prototype is ready!

Better Design and Control of Deviated and Horizontal Wells: HWDDDA

The Lowest OPEX Producer Wins the Production Game

Sucker Rods. Main Technical Parameters. Nominal dia mm(in) 15.88(5/8) 19.05(3/4) 22.23(7/8) 25.40(1) (1 1/8) Nominal outer dia.

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Analysis of Eccentric Wear of Sucker Rod and Design of Multi-Stage Flexibility Stabilizer

High-Pressure Jet Kerf Drilling Shows Significant Potential To Increase ROP

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

FISHING WITH THE AGITATOR SYSTEM

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

Standard Specification for Hardened Steel Washers [Metric] 1

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

BOP Ram Sensing and Interface Concept Rationale Intelligent BOP RAM Actuation Sensor System

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INTERNATIONAL STANDARD

Standard Specification for Hardened Steel Washers [Metric] 1

High Temperature InfraRed Thermometer with Laser Pointer

Low Cost Kinematic Couplings 2.75 Fall 2001

PlateScrape Plate Pre-Scrapper Test Report

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Model/Sprinkler Identification Numbers

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

Embedded Linux with VAR-SOM-MX6 Course

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

AMIS CAN High Speed Transceiver Application Note Loss of V33 Digital I/O Supply

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Installation Instructions

Artificial Lift. Integrated lifting solutions for enhanced well production

CO 2 EVAPORATOR DESIGN

Drive Power and Torque in Paper Machine Dryers

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

MODEL PR16 POWER ROTARY

Tom Miesner Principal Pipeline Knowledge & Development

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

Wells and Pump Servicing Tifft Symposium September 23, 2015

ISO INTERNATIONAL STANDARD. Road vehicles Four-pole electrical connectors with pins and twist lock Part 2: Tests and requirements

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

TECHNOLOGY ASSESSMENT FOR DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM CONTRACT NO. DE-FC26-02NT41664

TECHNICAL DATA. Wet 26a. February 22, 2009

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Induction Heating Technology for the Tube and Pipe Industry

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

NOVEL BOREHOLE- AND TEST PROCEDURES FOR UNDERGROUND GAS STORAGE ASSETS BY USING AN INTELLIGENT PIG FOR DOWNHOLE INSPECTIONS

NEMO BY. Industrial applications in all business fields for low to high viscosity fluids, with or without solids

Model Number Structure

ISO INTERNATIONAL STANDARD

Tube press Booster range. Superior performance

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Experimental Assessment of the Thermal Performance of Storage Canisterm01d ing Fix ture Conj?gurations

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

The original VAD development work at A Finkl & Sons,

55-Gallon Dispenser Package

Johnson Rice Energy Conference

Unequaled I Unrivaled I Performance

TecnoClean Coatings. Benefits

Transcription:

12 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 27 30, 2016 A New Sucker Rod Coupling Material: An Economical Solution for Downhole Wear in Deviated Unconventional Wells Seth Silverman and Logan Stoner Hess Corporation, Houston, TX William Nielsen and Diane Nielsen Materion Corporation, Mayfield Heights, OH

INTRODUCTION Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 2

Bakken ToughMet Pilot Project Develop a new base material for sucker-rod couplings Produce prototypes using production scale process Investigate torque/turn behavior relative to existing technology Make modifications to coupling surfaces interfacing with rod Select candidate wells Install ToughMet couplings during workovers Evaluate performance Sept. 27-30, 2016 2016 Sucker Rod Pumping Workshop 3

2015 Failure Statistics Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 4

ToughMet 3 UNS C72900 Copper-Nickel-Tin Heat-treatable alloy Very successful high strength, non-galling oilfield material over nearly 20 yrs and use is still growing Widely used for key components in directional drilling tools. Materion made selective property upgrades to ToughMet 3 that provide an ideal material for coupling Increased fatigue strength Increased fracture toughness Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 5

ToughMet 3 TS 95 Material UNS C72900 Cu-Ni-Sn alloy > 95 ksi minimum yield strength > 40 ksi fatigue limit > 30 ft-lb Charpy impact energy Resistant to chloride SCC, pitting and crevice corrosion Resistant to erosion, HE, SSC and general corrosion (including in mildly sour wells) Anti-galling to typical steel production tubing and sucker rods. Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 6

Typical Mechanical Properties of ToughMet 3 TS95 0.2% Offset YS, ksi 102ksi UTS, ksi 112ksi Elongation in 2in., % 24% RA % 57% CVN, Ft-lbs 55,55,70 Hardness 98HRB (20.5HRC) Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 7

Improved Fracture Toughness in ToughMet 3 TS 95 temper material Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 8

Comparison of T-Coupling, Spraymetal and ToughMet 3TS-95 T-coupling Spray Metal ToughMet 3TS-95 Surface Finish 125RMS in µ-in. 63 RMS in µ-in. 125RMS in µ-in. End Finish 125RMS in µ-in. 125RMS in µ-in. 250 RMS in µ-in. Hardness 16-23 HRC 55-60 HRC 20 HRC Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 9

ToughMet 3 Structure Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 10

Typical Sliding Friction Coefficients Selected Materials in Contact with Carbon Steel Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 11

Tribology Metal-on-Metal Wear Bearing Material Clearance Increase Due to Wear (inches) Oscillating axial motion with side loading. Average bearing stress @ 2,000 psi. Carburized steel shaft. Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 12

Fatigue Strength ToughMet 3 TS95 40 KSI 4-point bending; Rotating beam; R=minus 1; Room temperature Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 13

Corrosion fatigue strength ToughMet 3 TS95 4-point bending; Rotating beam; R=minus 1 Tests conducted for drilling mud environments Ending ph approximately 8 Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 14

Controlled Makeup/Breakout Tests at Key Energy Services Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 15

Field Trials Thirteen deviated wells running in Bakken shale locations Typically 10,000 ft vertical / 10,000 ft horizontal Sweet: range of water cut, sand, brine Typically six pump strokes per minute L80 production tubing Wells have history of elevated, frequent failure rates for target cause > 1 failure per year Installed 1 inch slim hole Couplings in deviated sections both nearsurface and deep No failures in 19 to > 31 months of continuous running 100% of inspected couplings suitable for placement back into service Wells continuing to run Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 16

Status of Initial Ten Pilot Wells GO Biwer 157-98-2635 H1 GO Braaten 156-07-3329 H1 GO Strahan 15-22 H GO Elvin Garfield 156-97-1819 H1 SC Tom 153-98-1514 H4 SC Tom 153-98-1514 H1 SC Tom LS153-98-1514 H1 GN Alice 158-97-1324 H3 GN EJ 158-97-0706 H1 GN-Ring-158-98-1522 H1 937 days 853 days 783 days 945 days 622 days 595 days 615 days 584 days 576 days 605 days Run time as of September 20, 2016 Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 17

Case History 1 GO ELVIN GARFIELD Pilot Testing Phase 1 Run-Time Enhancement Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 18

Improvement in Run Time with 24 ToughMet Couplings This well is still running. Runtime increased five-fold Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 19

GO Elvin Garfield Well Appearance of Coupling after 6 months in the well no evidence of wear or metal transfer Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 20

New and Used Coupling (Strahan) Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 21

Case History 2 GO STRAHAN 15-22 H WELL Pilot Testing Phase 1 Run-Time Enhancement Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 22

Strahan 15-22 H Well New Coupling 1.998 1.998 1.999 1.997 1.997 2.000 Average Reading = 1.998 Used Coupling 1.968 1.959 1.959 1.985 1.989 1.995 1.990 1.956 1.987 1.965 1.993 1.987 Average Reading = 1.978 Apparent diametric loss = 0.020 inches after 20 months running Apparent surface loss = 0.020/2 = 0.010 inches Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 23

Tubing Inspection ¾ inch full Steel SM Couplings; guided rods 1 inch slim ToughMet Couplings; guided rods Sept. 29-30, 2016 2016 PUMP Sucker Rod Pumping Workshop 24

Fewer Damaged Tubes Coupling Material SM ToughMet % of tubes having > 30% wall loss after 551 days 50 0 % of tubes having > 30% surface pitting after 551 days 25 0 Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 25

Reduced Tubing Damage ToughMet couplings increase MTTF of tubing by at least 3X (highest, lowest and mean values are shown) Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 26

Case History 3 GO BRAATEN WELL Pilot Testing Phase 1 Run-Time Enhancement Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 27

GO Braaten Well History March 2013 15 month runtime Deep tubing leak required WO May 2014 14 month runtime Deep tubing leaks due to wear Ran ToughMet couplings Feb. 2016 Deep tubing leak, 2 joints above seating nipple Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 28

ToughMet 3 Sucker Rod Couplings after 20 Months in a Well Evidence of contact between coupling and tubing. Insignificant wear: no flat spots and no evidence of metal transfer. Serial number still visible on the coupling 0.010 inches lost from outer surface Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 29

Coupling after 20 Months in the GO Braaten Well Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 30

Coupling after 20 Months in the GO Braaten Well Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 31

Coupling after 20 Months in the GO Braaten Well Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 32

Coupling after 20 Months in the GO Braaten Well Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 33

ToughMet Coupling and SM Coupling After 20 months in same section of well ToughMet SM Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 34

Case History 4 EN L CVANCARA WELL Pilot Testing Phase 2 Productivity Enhancement Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 35

1 st New Operating Trial 55 ToughMet Couplings ToughMet couplings installed in bottom 1,400 ft section 24 each ¾ Full; 31 each 1 Slim on bottom; one crossover Guided Tube/coupling friction coefficient Pump stroke (in.) Prior Standard Practice 0.2 ToughMet hypothesis 0.1 ToughMet hypothesis 0.05 ToughMet Actual 0.035 141 146 148 151 Liquid production (bpd) 233 240 243 248 Polished rod load (lbs) 33,000 32,500 32,200 31,570 Gear box max design load exceedance (%) 5 3 1 minus 2 Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 36

EN-L-Cvancara Well Pump Card Before Installation of ToughMet Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 37

EN-L-Cvancara Pump Card After Installation of ToughMet Fluid Output Up 6% Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 38

EN-L Cvancara Well Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 39

Oil Production Rates - Pre and Post Workover Rates Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 40

EN Leo Well Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 41

2 nd New Operating Trial 176 ToughMet Couplings Prior performance Pump Stroke Up 24% ToughMet performance Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 42

SUMMARY Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 43

Summary Costs of working over shale wells operating on artificial lift run into the hundreds of millions of dollars per year across our industry. Almost half of the failures in such wells are related to either tubing or sucker rod coupling failures, primarily caused by wear damage when couplings contact the inner tube wall. Materion and Hess Corporation collaborated to develop and field test a new coupling manufactured from ToughMet 3 TS-95, Materion s spinodal copper-nickel-tin alloy. Well run-times have improved significantly Well production has increased significantly 40 wells are now running; the program will be expanded. Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 44

Summary (continued) Results indicate the ToughMet Couplings can mitigate the most common causes of well failure, reducing work over costs by $100,000 per well per year. The return on investment is high and the payback is quick. Results indicate the ToughMet Couplings may reduce overall system friction and increase production. There have been NO failures of the ToughMet couplings and run times have improved up to five times over what they were previously. Material recovered from two wells after 6 months and 20 months show the couplings to be in almost new condition. The Hess pilot will be expanded to include up to 75 wells this year. Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 45

QUESTIONS? Sept. 29-30, 2016 2016 Sucker Rod Pumping Workshop 46

Copyright Rights to this presentation are owned by the company(ies) and/or author(s) listed on the title page. By submitting this presentation to the Sucker Rod Pumping Workshop, they grant to the Workshop, the Artificial Lift Research and Development Council (ALRDC), and the Southwestern Petroleum Short Course (SWPSC), rights to: Display the presentation at the Workshop. Place it on the www.alrdc.com web site, with access to the site to be as directed by the Workshop Steering Committee. Place it on a CD for distribution and/or sale as directed by the Workshop Steering Committee. Other use of this presentation is prohibited without the expressed written permission of the author(s). The owner company(ies) and/or author(s) may publish this material in other journals or magazines if they refer to the Sucker Rod Pumping Workshop where it was first presented. Sept. 27-30, 2016 2016 Sucker Rod Pumping Workshop 47

Disclaimer The following disclaimer shall be included as the last page of a Technical Presentation or Continuing Education Course. A similar disclaimer is included on the front page of the Sucker Rod Pumping Web Site. The Artificial Lift Research and Development Council and its officers and trustees, and the Sucker Rod Pumping Workshop Steering Committee members, and their supporting organizations and companies (here-in-after referred to as the Sponsoring Organizations), and the author(s) of this Technical Presentation or Continuing Education Training Course and their company(ies), provide this presentation and/or training material at the Sucker Rod Pumping Workshop "as is" without any warranty of any kind, express or implied, as to the accuracy of the information or the products or services referred to by any presenter (in so far as such warranties may be excluded under any relevant law) and these members and their companies will not be liable for unlawful actions and any losses or damage that may result from use of any presentation as a consequence of any inaccuracies in, or any omission from, the information which therein may be contained. The views, opinions, and conclusions expressed in these presentations and/or training materials are those of the author and not necessarily those of the Sponsoring Organizations. The author is solely responsible for the content of the materials. The Sponsoring Organizations cannot and do not warrant the accuracy of these documents beyond the source documents, although we do make every attempt to work from authoritative sources. The Sponsoring Organizations provide these presentations and/or training materials as a service. The Sponsoring Organizations make no representations or warranties, express or implied, with respect to the presentations and/or training materials, or any part thereof, including any warrantees of title, non-infringement of copyright or patent rights of others, merchantability, or fitness or suitability for any purpose. Sept. 27-30, 2016 2016 Sucker Rod Pumping Workshop 48