QUIETFLO OWNER S MANUAL

Similar documents
CHAMPION PUMP OWNER S MANUAL

Elite Primer Baldor Series External Pond Pump

SMF PUMP OWNER S MANUAL

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

AQUA-FLO A SERIES. The Bronze Pump designed exclusively for any swimming pool or spa application.

SuperFlo High Performance Pump

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

INSTALLATION INSTRUCTIONS

CHALLENGER CENTRIFUGAL PUMP

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS. Super Pump Series

HIGH PERFORMANCE PUMP

LC Series - Light Commercial Pump Station Installation and Operation Manual

Pump - Owner s Manual

HIGH PERFORMANCE 3-PHASE PUMPS

VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

50 HZ. MAX-E-PRO CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

HIGH PERFORMANCE PUMPS

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

Jacuzzi. J-VSP150, J-VSP250 Pump Installation and Operating Instructions

Variable Speed. Installation and User s Guide. Programmable Pump IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

OWNERS GUIDE TO INSTALLATION AND OPERATION

Perfect Settings Warranty Information

VL Series Pump. Owner s Manual. NOTE - To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.

Installation, Operating, and Service Manual. Badu. EcoM3. Swimming Pool Pump

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

BEFORE OPERATING THE MACHINE: WARNING

MAX-E-GLAS 2 SPEED CENTRIFUGAL PUMPS with TRAP

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

MDX² INSTALLATION MANUAL

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

CONSTANT SUCTION UNIT

HIGH PERFORMANCE POOL & SPA PUMPS

SSHM-2. Call Self-Priming Horizontal Multistage Pump. For further operating, installation, or maintenance assistance:

Food Waste Disposer Instruction Manual

QUIETFLO PLUS OWNER S MANUAL INSTALLATION, OPERATION & PARTS SAVE THIS INSTRUCTION MANUAL

SuperKlean Washdown Products

OWNER S MANUAL. SilentFlo. Pool Pump. For the Installation, Operation and Service of

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS SAVE THIS INSTRUCTION MANUAL

16 OUTDOOR MISTING FAN

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

HAYWARD POOL PRODUCTS, INC. 620 DIVISION STREET ELIZABETH, NJ (908) OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

Pool Power Pak. III with On/Off Switch UL Models (1 HP), (1-1/2 HP) NEC Models (1 HP), (1-1/2 HP)

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

569, 570, 571, 572 Series

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

This label warns for risk of electrical shock when failing to observe.

BACK WASH INSIDE THE SPA

569, 570, 571, 572 Series

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

SERIES ABG SWIMMING POOL PUMP

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:

SwimPro by HAYWARD 620 Division Street Elizabeth, NJ Tel:

Audi-Larm Audible Alarm

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

SAVE THIS INSTRUCTION MANUAL

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

HAYWARD POOL PRODUCTS POMONA, CA CLEMMONS, NC NASHVILLE, TN

Water Boilers ME10EN, ME15EN. Table of Contents

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

INSTRUCTION MANUAL DN0136 REVISION D

DYNA-PRO TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

17 GALLON PROFESSIONAL RESTROOM CLEANER

FOOD WASTE DISPOSER OWNER S GUIDE

Next Generation Corona Discharge Installation & Operation Manual

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Residential Gas Hybrid Water Heater

568X, 587X, 588X Series

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Single Lever Pull Out Kitchen Faucet

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

PRO SERIES IMPORTANT SAFETY INFORMATION

Wall Mount Electric Fireplace

Instructions for installation and use English. More documents on: H B /09

Transcription:

QUIETFLO OWNER S MANUAL INSTALLATION, OPERATION & PARTS To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completley. CAUTION - We highly recommend a qualified prefessional install and service this product. WARNING - This manual contains important safety information that must be funished to the end user of this product. FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY. SAVE THIS INSTRUCTION MANUAL 624 South B Street * Tustin, CA 92780 Toll Free: 800.636.8866 * Tel: 714.505.1166 * Fax: 714.505.1160 advantageman.com

PRODUCT REGISTRATION (Retain for Your Records) DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER) PUMP MODEL HORSEPOWER FILTER MODEL IMPORTANT SAFETY INSTRUCTIONS Before installing or servicing this electrical equipment, turn power supply OFF. Basic safety precations should always be followed, including the following: Failure to follow instructions may result in injury. This is the safety-alert symbol. When you see this symbol on your pump manula, look for one of the following signal words and be alert to the potential for personal injury. WARNING - Warns about hazards that could cause serious personal injury, death or major property damage and if ignored presents a potential hazard. CAUTION - Warns about hazards that will cause or can cause minor or moderate personal injury and/or property damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe. The NOTICE label indicates special instructions that are important but not related to hazards. WARNING - Read and follow all instructions in this owner s manual and on equipment. Failure to follow instructions can cause severe injury and/or death. NOTE: When pump is mounted permanently within 5 ft. of the inside walls of a swimming pool, you must use a NO.8 AWG or larger conductor to connect to bonding conductor lug. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all time. CAUTION - For hot tubs and spa pumps, do not install within an outer enclosure or beneath the skirt of the hot tub or spa unless so marked. 2

GENERAL INFORMATION WIRING WARNING: Risk of electrical shock or eletrocution. This pool pump must be installed by a licensed or certified electrician or qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage property. Always disconnect power to the pool pump at the circuit breaker before servicing the pumo. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. 1. Make sure all electrical breakers and switches are turned off before wiring motor. 2. Make sure that the wiring voltage matches the motor voltage (230v or 115v). If they do not match the motor will burn up. 3. Choose a wire size from Chart 1. When in doubt use a heavier gauge (larger diameter) wire. Heavier gauge will allow the motor to run cooler and more efficient. 4. Cut wires to the appropriate length so they don t overlap or touch when connected to the terminal board. 5. Make sure all electrical connections are clean and tigh. 6. Permanently ground the motor using the internal, green ground terminal located on the inside of the motor canopy or access plate, see Figure 1. Use the correct wire size and type specified by the National Electrical Code. Make sure the ground wire is connected to an electrical service ground. 7. Bond the motor to the pool structure in accordance with the National Electrical Code. Use a solid NO. 8 AWG or larger copper conductor. Run a wire from the brass external bonding clamp, see Figure 1, to the pool bonding structure. 8. Connect the pump permanently to a circuit. Maker sure no other lights or appliances are on the same circuit. NOTE: If the pump is installed below the water level of the pool, close return and suction lines prior to opening hair and lint pump. Make sure to re-open valves prior to operating. 3

THE PUMP STRAINER BASKET This unit, sometimes referred to as the Hair and Lint Trap, is the unit in front of the volute. Inside the chamber is the basket which must be kept clean of leaves and debris at all times. View basket through the See Through Lid to inspect for leaves and debris. Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint pot basket at least once a week. A dirty basket will reduce the efficency of the filter, heater and also put an abnormal amount of stress on the pump motor which would result in a costly repair bill. MAINTENANCE WARNING: DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personla injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to the touch, then with extreme caution only open the strainer pot. CAUTION: To prevent damage to the pump and filter and for proper operation of the system, clean pump strain and skimmer baskets regularly. PUMP STRAINER BASKET CLEANING PROCEDURES 1. Turn both motor and power off at house circuit breaker. 2. Relieve pressure in the system. 3. Turn the Lid in a counter-clockwise direction until it stops. 4. Lift lid and remove basket. 5. Put the debris from the basket into the trash and rinse out the basket. If the basket is cracked, it should be replaced. 6. Replace the basket and fill the pump pot and volute up to the inlet port with water. 7. Clean the cover, O-ring and sealing surface of the pump pot. Grease the O-ring with Teflon or silicone lubricant. 8. Re-install the lid. See Figure 2. a. Make sure the lid O-ring is properly placed. Seat the lid then turn clockwise until hand tight (Do not over tighten with tools). See Figure 3. 9. Turn the power ON at the house circuit breaker. Reset the pool time clock to the correct time. 4

WARNING: THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATION SYSTEM (e.g. LOCK RING, PUMP, FILTER, VALVES, ETC.) IS PRESSURIZED AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS. 10. Open the manual air relief valve on top of the filter. 11. Stand clear of the filter. Start the pump. 12. Bleed air from the filter until a steady stream of water comes out. Close the manual air relief valve. WINTERIZING 1. If the air temperature drops below 35* F the water in the pump can freeze and cause damage Freeze damage is NOT warrantable. 2. To prevent freeze damage follow the procecures listed below. a. Shut off electrical power for the pump at the house circuit breaker. b. Drain the water out of the pump case by removing the two drain plugs from the case. Store the plugs in the pump basket. c. Cover the motor to protect it from severe rain, snow, and ice. d. Do not wrap the motor in plastic. It will cause condensation and rust on the inside of the motor. CARE OF ELECTRIC MOTOR 1. Protect from heat. a. Shade the motor from sun. b. Any enclosure must be well ventilated to prevent overheating. c. Provide ample cross ventilation. 2. Protect against dirt. a. Protect from any foreign matter or splashing water. b. Do not store (or spill) pool chemicals near motor. c. Avoid sweeping or stirring up dust near motor while it is operating. d. If a motor has been damaged by dirt it voids the warranty. 3. Protect against moisture. a Protect from splashing pool water. b. Protect from the weather. c. Protect from lawn sprinklers. 5

3. Protect against moisture. (CONTINUED) d. If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has been flooded. e. If a motor has been damaged by water it voids the motor warranty. NOTE: DO NOT wrap motor with plastic or other air tight materials. The motor may be covered during a storm, for winter storage, etc., but never when in operation or expecting operation. SERVICE WARINING: Risk of electrical shock or electricution. This Pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or damage to property. Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electric shock. WARNING: DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personla injury, make sure the suction and discharge valves are open and strainer pot temperature is cool to the touch, then with extreme caution only open the strainer pot. PUMP DISASSEMBLY 1. All moving parts are located in the rear sub-assembly of this pump. Tools required: a. 1/2 inch open end wrench. b. 9/16 inch open end wrench. c. Flat and Phillips head screwdrivers. 2. To remove and repair the motor sub-assembly perform the following procedures. a. Turn off the pump circuit breaker at the main panel. b. Drain the pump by removing the drain plugs. c. Remove the 6 bolts that hold the main pump body (strainer pot/volute) to the rear subassembly. d. GENTLY pull the two pump valves apart, removing the rear sub-assembly. e. Remove the diffuser. CAUTION: Be sure not to scratch or mar the polished seal faces. Seal will leak if faces are damaged. 6

PUMP DISASSEMBLY - (CONTINUED) f. Hold the impeller securely in place and remove the impeller lockscrew by using a Phillips head screwdriver. The screw is a left-handed thread and loosens in a clockwise direction. g. Remove the shaft cap located at the back of the motor and hold the shaft secure with a flathead screwdriver (Century) or 7/16 inch open end wrench (Franklin). h. To unscrew the impeller from the shaft, twist the impeller counter clockwisee. i. Remove the four bolts from the seal plate to the motor, using a 9/16 inch wrench. j. Place the seal plate face down on a flat surface and tap out the carbon/spring seal. k. Clean the seal plate, seal housing, and motor shaft. PUMP REASSEMBLY/SEAL REPLACEMENT - SEE FIGURE 4 1. When installing the replacement ceramic/ carbon seal, use silicone sealant on the metal portion, before pressing into the seal plate. 2. Before installing the ceramic section of the seal into the impeller, be sure the impleller is clean. Use a light density soap and water to clean the seal. Press the seal into the impeller with your thumbs and wipe off the ceramic and carbon faces with a clean cloth. 3. Remount the seal plate to the motor. 4. Screw the impeller onto the motor shaft. 5. Screw in the impeller lock screw (counter clockwise to tighten). 6. Remount the diffuser onto the seal plate. 7. Grease the O-ring with Teflon or Silicone lubricant. 8. Assemble the motor sub-assembly to the strainer pot-pump body. Do not tighten down any of the bolts until all 6 bolts are in place and finger tight. 9. Fill pump with water. 10. Reinstall the pump lid by turning clockwise until hand tight (Do not over tighten with tools). 7