DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

Similar documents
Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Using the DewTrak II Dew Point/ Humidity Transmitter

Using the Model 1500 Portable Chilled Mirror Hygrometer

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

GE General Eastern Instruments

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

User s Guide. RHCL-2 Portable RH/Temperature Calibrator. Shop online at omega.com

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Humidity Measurement Technology Pros & Cons. Helping you make a better measurement.

Dew-Point Transmitters and Instruments

Vacuum drying oven for non-flammable solvents

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

Cabinet Cooler Systems

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Safety vacuum drying oven for flammable solvents

Inductive Conductivity

PDM 75 Portable Hygrometer OPERATORS MANUAL

Instruction Manual Model A

Pressure Swing Desiccant Dryers

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Model D12-IR. Digital Gas Transmitter...

Toxic Gas Detection. Model F12. Toxic Gas Detection

ACCURATE ELECTRONICS INC

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

DGC-500 DIGITAL GENSET CONTROLLER

Electronic Pressure Digest. Pressure and Temperature Transmitters

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

UDC100 Universal Digital Controller Specifications

TPF Series Ozone Generators

Model Q45P/R. ph/orp Monitor...

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

A New Standard of Excellence

Intelligent addressable fire alarm control panel

Model Q45P/R. ph/orp Monitor...

Leak Detection and Location Systems

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

The next generation thermometer from the global leader

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

HIH-4602 A & C Series.

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

NTC Thermistor Temperature Sensors. Product Information and Application Notes

Stability & Shelf Life

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Centro-Matic Automated Lubrication Systems System Controls

MR SERIES CARD LOGGERS

Optidew & Optidew Vision High Performance Optical Dew-Point Transmitter User s Manual

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Model DewTech390. Model DewTech 390. Chilled Mirror Dew Point Hygrometer. Instruction Manual

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Temperature Solutions Line Card

Humidity Measurement Technology

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Flow Level Pressure Temperature. Rugged tactile response keys. Try the all new Fluidwell Configurator at:

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Analog Room Pressure Monitor RPC Series

E340 BOILER CONTROL INSTALLATION MANUAL

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Model OEM-2 INSTRUCTIONS FOR USE

DAWN Electronics, Inc.

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

Series 5000 Hydrazine Analyzer Model 60002

Instruction Manual E4 ChamberIR Heater

RAM 50 Series Operation Manual

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Factors one should consider while selecting thermal equipment.

When reliability is vital. Alemite Carbon Shield TM Systems deliver

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Heatless Desiccant Compressed Air Dryers

OPTISENS TUR 2000 Technical Datasheet

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Rev B, 9/2/2009. Kodiak Chiller Overview

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

300/400 UNITS - MODULAR CONFIGURATION

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses

UDC 700 Universal Digital Controllers and Indicator Specifications

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002

"ESDDR" Series Electric Humidifier

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Transcription:

General Description The DPH-2020 is a two stage dew point hygrometer using the chilled mirror principle to determine the absolute humidity of a gas in terms of its dew- or frost-point temperature. It was specifically designed for critical industrial process applications. A state-of-the-art digital control system maintains the sensor mirror at the equilibrium point the point where a dew or frost layer is established on the mirror surface. A platinum resistance thermometer monitors the mirror temperature, which represents the dew- or frost-point temperature. Depending on the actual dew point, settling time from ambient may take a few seconds to one minute. Frost point measurements to 60 C or lower can be made. The high temperature Model DPH-2012 can make dew point measurements up to +120 C. Features Rugged stainless steel sheeted mirror provides extra durability in industrial applications Convenient front panel digital readout Multi-stage/extend operating range Both analog and RS-232 serial outputs Two alarm limit relays for control use Applications Chilled mirror dew point hygrometers are used in a wide variety of industrial process-control and laboratory applications to ensure product quality, including: Real time process control for pharmaceutical, painting, plate glass, paper, and injectionmolding production Production monitoring for dried foods and dry snack processing Monitoring of storage environments and special purpose rooms such as museums, warehouses, computer and clean rooms Manufacturing quality control for fabrication of sensitive electronic components such as semiconductors Building HVAC or air quality monitoring Heat treating furnace controls Sensor can be remotely located from electronics enclosure For very low dew point temperature applications, an integral chilled coolant loop DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 DPH-2020/2012 Dew Point Hygrometer Mechanical Configuration The DPH requires a sample stream of air or gas. The sample enters and exits the sensor via 1/8 National Pipe Thread (NPT) ports. Flow rates should be maintained between 0.2 and 1.0 standard cubic feet per hour (SCFH). The sensor operates between temperatures of 60 C to +80 C. A front panel DPM indicates the current dew point temperature to the user and set point relay contacts are provided. A Windows application supports remote viewing or integration with SCADA systems. The DPH-2020 can run from AC line or 12Vdc battery power; the DPH- 2012 requires AC power. Maintenance Unlike other sensors (polymer or aluminum oxide) that must be discarded once contaminated, a chilled mirror hygrometer can easily be cleaned to restore its performance. To restore proper operation of the sensor, the measurement chamber can be easily opened, inspected, and cleaned. A mirror microscope provides a means of inspecting the condition of the mirror prior to opening. The top of the sensor hinges open easily without tools via a single finger-operated spring clip. The cleanliness of the sample gas governs how often the mirror will need to be cleaned, but it is typically an interval from days-to-months.

Compare these features we offer at no extra cost: DPH sensor cross-section view DPH sensor rear view DPH sensor showing access to mirror for cleaning DPH sensor bottom view of heat sink and integrated cooling fan

Mechanical Interface Side view - dimensions in inches [cm] Top view - dimensions in inches [cm]

Specifications Dew/frost point range* Accuracy Sensitivity Repeatability Hysteresis 2020: 65 C depression; from room ambient temperature of 22 C, dew/frost point measurements can be made to approx. -40 C with room temperature installations; 2012: +120 C to 40 C; down to 60 C with customer-supplied 20 C liquid coolant loop ±0.1 C ±0.01 C ±0.01 C None Response time Power Supply Gas contacts Output signals Storage Temp Range * 35 seconds (typical) 2020: 110/220 Vac or 12Vdc 2012: 110/220 Vac only approximately 100 watts Anodized aluminum, Viton, stainless steel, glass ±5 Vdc analog, limit (Form C relay), RS-232 Sensor: -50 C to +80 C Electronics: -50 C to +50 C *Note: working depression limit is a function of ambient sensor temperature. A customer-supplied chilled coolant loop permits lower dew point range. Measurement span of one-and two-stages Standard Accessories Provided at No Extra Charge Totally inert mirror sensor chamber Full digital control for precise operation Analog and digital outputs, PLUS alarm relays Mirror microscope permits visual verification of dew layer and mirror state during operation Forced air cooling improves reliability Auxiliary liquid cooling loop permits even lower temperature depression operation REGULATED LED SUPPLY AMP GAS SAMPLE P N POWER SUPPLY -22.2 o C Chilled mirror principle of operation 4 WIRE 100 OHM Copyright 2003 Yankee Environmental Systems, Inc. All Rights Reserved. Specifications subject to change without notice.