intrinsically safe detector for hydrocarbon gases

Similar documents
Datalogging as standard

GAS ANALYSIS / DETECTION Gas Detector

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

T.ex Single Gas Detector VISA

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

MicroRay IR-100 NEW. Inspection MicroRay IR-100

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Operate the Mutli-Gas Monitor PID

ALTAIR 5X Multigas Detector Product Specification

Dräger X-am 7000 Multi-Gas Detection

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

For the Safety of Your

Polytector III G999 for Ex zone 0

CD100A COMBUSTIBLE GAS DETECTOR

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

CALIDUS tm the Modular micro Gas Chromatograph

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Moisture and Hydrocarbon Dew Point Measurement

Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

Gas Detection - GD -

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Dräger X-am 5000 Multi-Gas Detection

GasAlertMicroClip X3 Specifications

We measure it. testo 316-Ex CH 4 testo 316-1

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

F-900 Portable Ethylene Analyzer

CO warning instruments and gas spillage detectors

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Mobile CWA Detection and Identification. Innovation with Integrity. Mobile Mass Spectrometer MM2 CBRNE

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Complete Gas Analysis

portable gas analyser

Process Gas Chromatograph

PERSONAL COMBUSTIBLE GAS DETECTOR

multi-gas detector Go the distance, and save Wear yellow. Work safe.

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

portable gas analyser

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

G-TECTA TM. Portable Gas Detection Instruments

Dräger X-pid 9000 / 9500 Multi-Gas Detection

ALTAIR 5X Multigas Detector

Dräger X-am 5000 Multi-Gas Detection

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Fixed Gas Detection Equipment

Series 9000 Total Hydrocarbon Analyzer

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Refrigerant Leak Detection Solutions

Parker icount Oil Sampler (IOS)

FirstCheck+ 1000, 2000, 3000 & 5000 User Manual V1.7

AGT 1 Confined Space. Authorised Gas Tester 1. Scienco Limited. Authorised Gas Tester 1 1

gas monitoring system

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Unrivalled Detection.

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Safe Operation Manual. Honeywell IQ Force Gas Detector

IT S WHAT S INSIDE THAT

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Choosing the best confined space gas detector

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Monitores Personales. Personal Monitor

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

SIMRAD GD10PE IR GAS DETECTOR

Chemtron Science Laboratories Pvt. Ltd.

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

LS1. Operator Manual. Kane International Ltd

931D Style B Process Gas Chromatograph

MICROpeL 75 Combustible Gas Sensor Part Number: PM

IT S WHAT S INSIDE THAT COUNTS

Dräger Pac 6000 Single-Gas Detector

Process Gas Chromatograph

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

RAE Systems Systems. User Presentation. October Protection Through Detection

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

icount Oil Sampler (IOS)

Reference Manual. MultiVision Gas Detector

APPLICATION DATA SHEET

REFRIGERANT LEAK DETECTOR

Reference Manual MultiPro Gas Detector

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

Tetra 3. User Manual. Personal Multigas Monitor. M07654 January 2007 Issue 3

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

HFID Heated Total Hydrocarbon Analyzer Module

GASMAN II PERSONAL SINGLE GAS MONITOR INSTRUCTION MANUAL

Personal & Portable Gas Monitors

Instruction Manual MSI Sensit HXG

Nardalert S3 TM Non-Ionizing Radiation Monitor

Transcription:

portable flame ionisation detector intrinsically safe detector for hydrocarbon gases

Intrinsically safe detector for hydrocarbon gases Monitoring gases in confined and potentially explosive situations has become increasingly important particularly in the wake of new environmental legislation. Autofim II and Autofim II GC give you the flexibility and confidence you need to detect, measure and analyse hydrocarbon gases in virtually any hazardous location from petrochemical plants and gas works to landfill sites. These versatile products cover a wide range of applications including: volatile organic compound monitoring, fugitive emissions, process control, gas leak surveying, contaminated land and landfill sites. Supported by one of the leading names in gas detection, with over 25 years experience, these two detectors are fast, accurate, reliable and, most importantly, intrinsically safe. Intrinsically safe To safely detect gas in hazardous areas, it is essential your equipment is certified as intrinsically safe. Autofim II and Autofim II GC have been designed so you can be confident that staff and plant are fully protected. Reliable, fast and highly sensitive The Autofim range has been engineered to provide outstanding stability. So you can always rely on the results without the need for weekly re-calibration. To localise leaks quickly and safely your detector must react rapidly and accurately. The flame ionisation detector ensures a rapid response: within 2 seconds. Expanded scales allow you to detect and measure gases with pinpoint accuracy even at the lowest levels. Simple to use Autofim is easy to use with the operator being guided by user-friendly, menu-driven software. For maximum clarity the signal is displayed in both digital and analogue formats plus a variable pitch audible output. Furthermore, the audible signal can be set only to trigger above an adjustable alarm level.

The system can operate for over 40 hours without changing the batteries or cylinder. However, replacement of these in the field is a simple operation for remote or extended use. Easy to read in the dark The back lit display allows you to take readings in tunnels, basements and other dark spaces without the need for additional lighting. Unrivalled measurement range Autofim covers the full range of measurement from 0 to 10,000 ppm in a convenient range of scales. The optional range extender/diluter allows measurements above 10,000 ppm as well as from oxygen depleted atmospheres. Light, portable and robust Weighing just over 4 kilos Autofim is truly portable.

for gas detection and analysis Autofim II GC, with in-built gas chromatography, can not only detect gas with all the benefits of Autofim II but can also determine its composition on-site. There are many situations where it is necessary to determine the exact nature of the detected gas. Analysis is highly beneficial for compliance monitoring and essential for differentiating between natural gas and other hydrocarbons. Autofim II GC displays the chromatograph immediately, avoiding the delays and cost of laboratory analysis. Versatile Having detected gas, a sample is stored in a holding loop. This can be analysed immediately or later, if more Benzene, toluene & xylene convenient. After analysis the GC data is stored in memory for subsequent reference. Wide range of gases A series of high-resolution, chromatography columns are available; tailored to most applications including VOC s, natural gas, petrol vapours, and landfill emissions. These can be easily interchanged, by the user, to address a variety of different site emissions. Detailed analysis Data can be downloaded to an external PC for further analysis and presentation. The Integraf software package, specifically designed for Autofim, analyses the data and displays a range of parameters including: retention times, peak identification, peak areas, methane/ethane ratios and relative concentrations. Graphical and tabular formats are available. The overlay facility allows comparisons between Ketones your sample trace and a library of reference chromatograms.

Datalogging as standard for expanded performance Autofim II and Autofim II GC have a sophisticated datalogging system, as standard, which enables you to keep a permanent data record. The memory is capable of storing 200,000 individual readings. Logging on demand This facility simplifies site surveying by allowing the operator to store readings in a single file, as desired. Photo: Courtesy of Shell Global Solutions Timed interval logging Autofim automatically measures and stores data at user defined time intervals without an operator needing to be present. In this way gas concentration contours can be recorded over a period of time which is especially useful for process monitoring. Data transfer to PC The detachable infra-red, fibre-optic link allows data transfer to a computer for further manipulation and presentation. The software is compatible with most recognised spreadsheets enabling you to integrate Autofim data with your reports and other records.

performance Range: 0 to 10,000 ppm (methane) Detection limit: 0.1 ppm (methane) Response time: less than 3 seconds Hydrogen cylinder discharge time: Refillable: up to 45 hours (30 hours in GC mode) Disposable: up to 30 hours (20 hours in GC mode) Sample flow rate: 700 ml/min (automatically controlled) display 240 X 64 pixels (132 x 370 mm ) power Battery life: up to 40 hours with 6 MN1400 Duracell alkaline batteries (certified Intrinsically Safe) operating conditions Temperature: 0ºC to 40ºC Humidity: 30% to 90% ERH non-condensing GC column: operates at ambient temperature dimensions Autofim II / II GC: 370(l) x 135(w) x 225 (h) mm Weight: with refillable hydrogen cylinder Autofim II: 4.2kg Autofim II GC: 4.5kg output Audio output: variable pitch and adjustable volume Electrical output: infra-red fibre optic cable to RS232 link certification Approvals: EEx ib IIC T4, EEx d IIC T4 Standards: EN 50014, EN 50018, EN 50020 RF radiation: EN 50081-1 RF immunity: EN 50082-1 standard accessories Autofim II Autofim II GC Fitted carrying case with strap Telescopic probe & detachable survey head Rechargeable hydrogen cylinder Batteries Particulate and hydrophobic filters Downloading kit with fibre optic RS232 link to IBM compatible PC Syringe & needle Standard GC column optional accessories Autofim II & Autofim II GC Range extender/diluter Acoustic earphones Probes: bore hole probe, roller probe Spare fuel cylinders Range of GC columns Hydrogen filling panel Integraf GC SW package (PC) Calibration kits: Methane in balanced air Clean air kits for zeroing Servicing: Service schemes incorporating maintenance and calibration. distributed by: 217142066 217145674 (A division of Crowcon Detection Instruments Ltd) info@ert.pt www.ert.pt TELEGAN GAS MONITORING LTD Telegan Gas Monitoring (A division of Crowcon Detection Instruments The Fleming Centre Fleming WayLtd)Crawley 2 Blacklands Business Park Abingdon West Sussex Way RH10Abingdon 2NN England Oxfordshire+44 OX14 1DY 528866 United Kingdom Telephone (0)1293 Fax +44 (0)1293 528811 Telephone +44 (0) 1235 553057 Fax +44 (0) 1235 553062 e-mail: telegan@netcomuk.co.uk e-mail: sales@telegangas.co.uk www.telegangas.co.uk Rua Soeiro Pereira Gomes, Lote 5, Cave Drt. P2845-387 Amora Portugal PO 1105 Issue 1 ISONo. 9001 Certificate FM21228 Cert. No FM 12734 BS EN ISO 9002:1994