4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available

Similar documents
Neptronic Toll Free: TEL: (514) Fax:(514)

Visit our web site at

Custom Duct Heaters. Special Applications

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

Custom Duct Heaters. Special Applications

Electric Coils. Blower Coils. Product Information

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Electric Duct Heaters. IDHB & IDHC Series

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

FINNED WATER-TUBE POOL HEATERS

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

Networkable Fan Coil Controller Specification and Installation Instructions

DIVISION FINNED WATER-TUBE BOILERS

The SKE humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

ULTRA-SAFE Explosion-proof Duct Heaters

DIVISION FINNED WATER-TUBE BOILERS

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

Accuracy by Design Products for the HVAC Professional

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

NH-EL. The evolution of the industry s most trusted electrode steam humidifier NH SERIES. humidity.com

SEQUENCE OF OPERATIONS

DIVISION FINNED WATER-TUBE BOILERS

SINGLE DUCT TERMINAL UNITS

ULTRA-SAFE Explosion-proof Duct Heaters

Fan Coil Thermostat. Specification & Installation Instructions TFC54F3Y1. Technical Data

DIVISION FINNED WATER-TUBE BOILERS

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

( )

(770) wwww.southgateprocess.com

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Advantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

RE-PR3-E-27 3-Phase Panel Mount 27kW

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

"ESDDR" Series Electric Humidifier

Power and Energy Management Solutions

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

STEAM TO STEAM HUMIDIFIER

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Chilled Water DOAS Fan Powered Terminal Units

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Tankless On Demand Electric Water Heater

M1 SERIES DUCT HEATERS

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

STEAM TO STEAM HUMIDIFIER

Humidity Controller Specification and Installation Instructions. Model HRO20

Cultivator & Hybrid Cultivator

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

- Data Brochure Universal Reset Module 422

FINNED WATER-TUBE POOL HEATERS

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Custom modular design to fit any application

Flexible & Innovative. Cooling Solutions

Lynergy Comfort Control SCR Electric Heater Application Guide

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Sequence of operation

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

CAREL heatersteam Electric Element Steam Humidifiers

SECTION HUMIDITY CONTROL EQUIPMENT

L CONNECTION NETWORK Commercial Controls

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

opti-visor ultra-efficient chiller plant automation Typical specification

EHH SERIES DRAW THROUGH FAN COILS CFM

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

TABLE OF CONTENTS page 2

MEDICAL CHILLER SYSTEMS

Hydronic & HVAC Control Systems

State of the Art. Exceptional Reliability

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

Pressure Steam Humidifiers LS SERIES. humidity.com

SKG Advantages. Typical Applications. Typical Installation

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Circulating Water Temperature Controller

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in proven quality

RESISTIVE STEAM HUMIDIFIER

Electric Heat - Air Curtains

DAIKIN Air Handling Unit Modular

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

New Versa IC Platform

UNIFIED FACILITIES GUIDE SPECIFICATIONS

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

Transcription:

The Neptronic electric heater is manufactured using the most advanced technologies available. Total automation from design to production using integrated CAD/CAM systems not only assures maximum efficiency, but also prevents errors in plans and specification data.the most advanced CNC technology for sheet metal fabrication is used in manufacturing the heaters. All these factors are key to offering standard features that our competitors offer only as options, and allows us to respond in record time to your needs and to the most demanding specifications. Electric Heater Advantages 4HECB Networkable Electric Duct Heaters 4Patented EAS Electronic Air Flow Sensors (US 7,012,223) 4Unique interactive software 4Up to 40kW per sq. ft. (24 kw per sq. ft.) 4Modulating, ON/OFF or staging 4Standard from 0.5 to 1000 kw, larger loads available Typical Applications 4HVAC systems VAV boxes 4Fan coil units 4Load banks testing 4Make-up air / Air handlers 4Process air heaters 4Transport / Railcar / Marine Typical Installation Slip-In Flanged Round Collar The slip-in type electric heaters are designed so that the entire frame can be inserted into the duct. Using a slip-in heater permits the installation of the entire ventilation duct system before the heaters become available. Flanged heaters are designed so that the heater is an integral part of the duct work. The heater frame is attached to matching duct flanges. Standard 1" (25.4mm) flanges on the heater frame are used to attach it to the duct. Round collar electric heaters are available for installation on round duct systems with a standard diameter of 6" to 24" (152mm to 609mm). They are provided with one male and one female adapter for ease of installation.

System Overview Disconnect Switch (Lockable) Cuts the power supply to the heater in order to safely perform installation and maintenance tasks. (Standard when required by code, otherwise optional) Enclosure Manufactured with the appropriate galvanized steel gauge to assure rigidity and corrosion protection Slip-In type frame Permits the installation of the entire ventilation duct system before the heaters become available. Retrofits are much simpler, smaller dimension slip-in heaters require no extra supports Control terminal block Line voltage terminal block Stage fuses Protect the total load and/or the individual heater stages. (Standard when required by code, otherwise optional) Transformer Supplies power to the control circuit. Supplied with a fuse Contactor Provides power to the individual stages of the heater Variety of Heating Elements Control Panel Patented EAS Electronic Air Flow Sensors No mechanical air flow switch required. Shuts off heater if air flow is too low. Protective screen Prevents accidental contact with heating elements (optional) Open Coil Tubular Finned Tubular 4Grade C NiCr60 (60% Nickel and 16% Chrome) 4Grade A NiCr80 (80% Nickel and 20% Chrome) Advantages 4Excellent heat dissipation 4Minimal pressure drop 4Fast response time 4More kilowatts per sq.ft. 4Quick delivery 4Incoloy 800 (Nickel alloy) 4Stainless steel 304 or 316 4U or W shapes depending on heater dimension Advantages 4Less sensitive to humidity and dust 4Suited for demanding environments 4Excellent mechanical resistance 4Heating element not in direct contact with air 4Incoloy 800 (Nickel alloy) 4Stainless steel 304 or 316 4U or W shapes depending on heater dimension. Aluminum fins and available with stainless steel fins as an option to allow for more efficient heat dissipation. Advantages 4 Good heat dissipation 4 Less sensitive to humidity and dust 4 Suited for demanding environments 4 Excellent mechanical resistance 4 Heating element not in direct contact with air

Mounting Panel Options Bottom Control Panel A bottom control panel can be supplied, when required for easy installation and maintenance. This option is available for all heaters (Slip-in, flanged and round collar) of small dimensions. Insulated Control Panel INSULATION 1 (25.4mm) An insulated control panel is recommended for high duct temperatures. Insulation material, 1" (25.4mm) thick is installed between the panel and the hot area to prevent condensation on electrical components. Remote Control Panel In certain cases it may be more convenient to install the control panel remotely from the heater or in a separate room. A remote control panel can be supplied upon request. Zero Clearance Construction All Neptronic heaters are designed and approved for zero clearance to combustible material. Zero clearance construction means that there is no restriction on the distance between combustible materials and the section of the duct housing the heater, or the heater itself. The control panel must be accessible for servicing. Enclosure Types Neptronic heaters come with enclosure types Nema 1, Nema 12, Nema 4 and Nema 4x. Special Heaters 4Heater equipped with automatic and manual thermal cutouts 4Large Heaters with reinforcement and multiple cut-outs 4Process Heaters for applications requiring a high discharge temperature up to 1200ºF with proven standards

Neptronic introduces the first BACnet/Modbus Electric Duct Heater. Designed with today s energy efficiency expectations, it enables you to view real-time power consumption, to perform automatic/dynamic load shedding, limit consumption based on multiple variables, create energy optimization strategies as well as monitor trends and alarms. BMS Integration BACnet & Modbus Energy Management Monitor Alarms Remote Diagnostics Auto Load Shedding Unique Benefits 4Integrate with BMS and intelligent buildings via BACnet MS/TP or Modbus 4Real-time feedback output signal of heater capacity 4Built-in Current Transducers (1 per phase) Provides power consumption data (KW in real-time) 4Calculate T by using the provided supply and discharge temperature sensors. This allows the possibility to read the air temperature before and after the heater elements from your BMS 4Configurable BACnet scheduler (6 events) 4Optional wall-mount room thermostat with LCD (TRL24)Enables the user to remotely view the status of the heater and change the setpoint 4Built-in PID algorithm Maximizes the heater s efficiency when there is a sudden change of velocity or temperature within the system 4Remote monitoring (status, alarms, diagnostics, and trending) 4Multiple BACnet/Modbus points to propel you towards the Internet of Things

Heater Selection Software Our selection software allows access to technical data and formulas to specify Neptronic heaters and much more. Whether you are an engineer or a contractor, our software allows you to select the required electric heater by entering basic data (duct dimensions, airflow, power, voltage, number of stages, control signals, etc.) from a user friendly window. The selection software then calculates the optimum specifications for each electric heater. The comprehensive heater specifications, as well as the approval list, may be edited or inserted in the project file. Interactive Online Software Linked to an automated manufacturing process. Neptronic s web-based selection software allows you to easily select the required electric heater by entering the basic data. Specifications entered are transformed in parametric design Electric heater is produced by automated machines Heater is ready in record time produced with minimum human inputs. 4Multiple components & options available to design your heaters 4Allows you to make as many changes as you want in your selection 4Retrieve immediately your heater s schedule and specification 4Creates mechanical and electrical drawings 4Generates approval specification sheets 4Saves your project history in a database

Thermostats & Temperature Sensors for Electric Heaters TRO24-EXT1 Room controller thermostat TRO5404 Room controller thermostat STS3 / ITO3 Wall thermostat 4For modulating, ON-OFF, staging or pulsed heater 4Backlit LCD display 42 heat / cool analog ouputs (0-10VDC) 44 TRIAC outputs (for ON-OFF, pulse or floating signal) 4Selectable internal/external temperature sensor 4Selectable proportional control band 4Selectable internal/external temperature sensor 4Fahrenheit or Celsius scale selectable STR1 Room temperature sensor 4For modulating, ON-OFF, staging or pulsed heater 4Backlit LCD display 42 heat / 2 cool analog outputs (0-10VDC) 41 TPM (time proportional modulation) output (0 or 22VDC) 4Selectable internal/external temperature sensor 4Selectable proportional control band 4Fahrenheit or Celsius scale selectable STC8 Duct temperature sensor 4Modulating, ON-OFF or staging heater 4STS3 with sensor 3.3 KΩ or available in 10 KΩ 4ITO3 wall thermostat must be used with external duct or wall sensor 4Fahrenheit or Celsius scale selectable TMA54 Wall mount controller 4Wall sensor for remote temperature reading 4Sensor 3.3 KΩ or 10 KΩ available 4Duct sensor for remote temperature reading 4Sensor 10 KΩ 4High accuracy, fast thermal response 4Epoxy encapsulated sensor 4High stability 4Features a fully configurable Proportional- Integral-Derivative (PID) 42 heat / cool analog ouputs (0-10VDC) 4Selectable internal/external temperature sensor 4Fahrenheit or Celsius scale selectable

Heater-EBA-170313