Outside Air Humidity & Temperature Sensor

Similar documents
Duct Humidity/Temp Sensor

Room Humidity/Temp Sensor

Duct Temperature Sensors

Web-Enabled Thermostat IP-MT-101

Potential Applications

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

PT9420 (Extended Range)

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

HIH-5030/5031 Series Low Voltage Humidity Sensors

HIH-4030/31 Series Humidity Sensors

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

Model 5190-F Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

HM1520LF Relative Humidity Module

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

M7100 Pressure Transducer

SEC Signature Process Gas Analyzer

Warranty Registration

HIH-4602 A & C Series.

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

HIH-4602-L Series Humidity Sensors

User s Guide. Shop online at. Made in China. Two-wire Display and Control Unit

HM1500LF Relative Humidity Module

HIH-4010/4020/4021 Series Humidity Sensors

NT DUAL CHANNEL DISPLAY. User Guide

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

HIH-4000 Series Humidity Sensors

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

TL-105 COLUMN HEATER

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information


GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

MEAS CAL ALARM WASH CONF APT4000 TC

Ultrasonic Reflective Sensor

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

SKORPION Process Air Heater

Airflow Sensors Line Guide

Reacti-Therm I and III Heating Modules

Toroidal Conductivity Transmitters Series APT4000 Specifications

Airflow Sensors Line Guide

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Duct Mount. Installation Instructions

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

User s Guide. FLSW Series ROTAMETER WITH ALARM. Shop online at omega.com. For latest product manuals:

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

NTC THERMISTOR SENSOR PERFORMANCE

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

PM-200 Power Module Operating Instructions

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Cable Actuated Sensor Industrial User Scalable 4 20mA

OSRAM 8/12/00 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

FSS-SMT Series. Low Profile Force Sensor

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

(HSTAT Series) Instruction Manual

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

Sensors in Ventilators

OPERATION MANUAL MODEL & ACCELEROMETER

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

LVCN-302 Set-Up Manual for Sump Model

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Installation, Operation, and Maintenance Manual

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

OPERATING INSTRUCTIONS

Transcription:

Outside Air Humidity & Temperature Sensor RoHS Model HU-227 Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing element from condensation, fog, salt air, pollutants and other contaminants Conformal coated and moisture sealed electronics Rugged steel enclosure and thick-walled aluminum probe rated NEMA-4 (IP-65) to withstand weather extremes NIST traceable ±2% RH or ±3% RH calibration accuracy Two temperature compensated humidity...output versions, 4-20 ma 2-wire or field...selectable 0-5 VDC/0-10 VDC Conforms to EMC and RoHS standards The HU-227 Outside Air Humidity and Temperature Sensor is designed to handle 100% condensing humidity. The electronics are moisture sealed with an acrylic coating, and the sensing element is protected with an eptfe (expanded Teflon) filter media. The unit can be directly mounted inside fresh air hoods of air handlers or underneath roof overhangs of any building. The sensor can also be installed inside the air handler fresh air duct. The Teflon protected cross-linked capacitive humidity sensor is not affected by prolonged exposure to condensing humidity, harsh environments, contaminants, fog or other extreme environmental conditions. The rugged NEMA-4 (IP-65) rated steel enclosure, thick-walled aluminum probe and gasket sealed cover offer a reliable solution for factory-mounted applications. Each HU-227 is calibrated at multiple points in a NIST traceable calibration chamber to meet or exceed ±2% RH or ±3% RH accuracy. Units are temperature compensated over -30 F (-35 C) to +130 F (55 C) temperature range operation with negligible error. HU-227 is available with more than 16 types of interchangeable NTC thermistors, precision platinum, nickel or balco RTDs for universal compatibility. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 DN227.4 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 Registered trademark MAMAC SYSTEMS, Inc. 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876

The HU-227 incorporates a cross-linked bulk polymer capacitive humidity sensor and precision NTC thermistor, platinum or balco RTD temperature sensor. Both temperature and humidity sensors are immune to most contaminants and at the same time provide a stable, repeatable, accurate humidity and temperature measurement with negligible hysteresis. The sensing elements are not affected by condensation. In fact, the probe may be immersed in distilled water without degrading the calibration accuracy. The HU-227 utilizes sophisticated integrated circuits to provide a high level, fully conditioned, and temperature compensated humidity output. The thermistor temperature sensors are available with more than 16 different industry standard resistance to temperature curves offering compatibility to most if not all control systems. All thermistor sensors offer ±0.2 C interchangeability/accuracy and strictly conform to industry standard R/T curves. The platinum RTD s are available with 100 ohm or 1000 ohm DIN 43760 standards with ±0.12% accuracy at 0 C. All temperature sensors have more than 3.0 mw/ C heat dissipation constant. On VDC output units (humidity only), two additional field selectable options are available; dual outputs 0-5 or 0-10 VDC, and dual unregulated supply voltages 12-35 VAC or 12-40 VDC. By merely moving a switch, one can select the desired output for the specific application. As far as supply voltage is concerned, the unit automatically configures for AC or DC and no field selection is necessary. The VDC output unit is also designed to handle low impedance circuits. In fact, the unit can drive up to 1K ohm minimum. In this way, multiple controllers, indicators, or other devices can be paralleled to the output without performance degradation. The ma output units (humidity only) function over a wide unregulated supply voltage range: 12-40 VDC without any effect on calibration or performance. The unit has reverse polarity protection built in. As a result, it is next to impossible to damage the unit by wiring incorrectly. By using sophisticated low dropout voltage regulators and CMOS integrated circuits, the ma output unit can drive very high output impedance. In fact, with only 12 VDC supply, the unit can drive 250 ohms. At 40 VDC, the unit is capable of handling up to a 1500 ohm load. In this way, the output loop can be tied in series to multiple controllers, indicators, and other devices without degrading the performance. The humidity sensor is protected by an eptfe (expanded Teflon) filter media that incorporates a proprietary process of expanding or stretching an ultra thin Teflon sheet during the manufacturing process to create less than 1.0 micron (0.000039 inch) pores or holes. The hydrophobic and oleophobic characteristics of Teflon force moisture, condensation and other contaminants to form a bubble larger than the pore size, and the surface tension of the Teflon stops the water or other contaminants from passing through the filter media, thereby protecting the sensing element. However, air with absorbed moisture can easily penetrate the filter media. The PCB electronics are coated and sealed with an acrylic conformal coating to protect against moisture, condensation and contaminants. The HU-227 incorporates a rugged NEMA-4 (IP-65) fully gasketed, dust proof and splash proof enclosure. The enclosure has an external mounting bracket to facilitate field installation. A ½" (.875"/22.25 mm diameter) knock-out for conduit connection is also provided. A liquid tight cable connector is supplied if the unit is not being hard wired. Once installed, the enclosure maintains its environmental rating and protects the electronics and the sensing element from condensation, corrosive contaminants and other environmental pollutants. The enclosure also has additional features for ease of installation including unpluggable terminal block and easily accessible zero and span trimmers. 2

HUMIDITY TRANSDUCER SPECIFICATIONS: Accuracy*: ±2% / ±3% RH Range: 0-100% RH Hysteresis: ±1% Supply Voltage: 12-40 VDC 12-35 VAC (VDC output units only) Compensated Temp Range: -30 F to 130 F Load Impedance: 1.5K ohms max. at 40 VDC (ma output units) 1K ohms min. (VDC output units) * Includes non-linearity and non-repeatability PLATINUM RTD SENSOR SPECIFICATIONS: Accuracy: 0.12% at 0 C Resistance: 100 or 1,000 ohm at 0 C Standard: DIN 43760 Heat Dissipation: 3.0 mw/ C R/T Characteristics: Refer to TI.700-11 (See Temperature Sensor section) Operating Temp Range: -30 F to 130 F THERMISTOR SENSOR SPECIFICATIONS: Interchangeability: ±0.2 C Heat Dissipation: 3.0 mw/ C R/T Characteristics: Refer to TI.700-11 (See Temperature Sensor section) Operating Temp Range: -30 F to 130 F GENERAL SPECIFICATIONS: Environmental: 10-100%RH Enclosure: 18 Ga C.R. Steel NEMA 4 (IP-65) Finish: Baked on enamel - PMS2GR88B Termination: Unpluggable screw terminal block Wire Size: 12 Ga maximum Weight: 1.0 lbs. (.45 kg) CONFORMANCE & TESTING: RoHS Compliant EMC Testing: BS EN 55022:1998, BS EN 55024:1998, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 ORDERING INFORMATION: HU-227- Accuracy Output Temperature Sensor ±2% ±3% ma (4-20 ma 2-wire) VDC (0-5 VDC/0-10 VDC field selectable) Example: HU-227-2-mA-3: Outside Air Humidity and Temp Sensor, ±2%RH accuracy with 4-20 ma output and 1,000 ohm Platinum RTD. For Resistance vs. Temperature Tables, please refer to TI.700-11. 1 100 ohm Platinum RTD 2 1,000 ohm Nickel RTD (5000 PPM) 3 1,000 ohm Platinum RTD 4 1,000 ohm Nickel RTD (6000 PPM) 5 1,000 ohm Balco RTD 7 10,000 ohm NTC thermistor (Type III) 8 10,000 ohm NTC thermistor (Carel) 10 3,000 ohm NTC thermistor 12 10,000 ohm NTC thermistor (Type II) 13 5,000 ohm NTC thermistor 14 1,035 ohm Silicon PTC 15 100,000 ohm NTC thermistor 16 10,000 ohm NTC thermistor (Eliwell) 17 20,000 ohm NTC thermistor 18 2,252 ohm NTC thermistor 21 1,800 ohm NTC thermistor CAUTION: Do not use in explosive/hazardous environment or with flammable/combustible media. 3

4.50" (115.0) 2.00" (50.0) 2.15" (55.0) 5.00" (127.0) 1.00" (25.0) 3.20" (81.0) 2.65" (67.3) 4.00" (102.0) 2.25" (57.0) 0.50" (13.0) (mm) DN227.4 Registered trademark MAMAC SYSTEMS, Inc. 4

MAMAC Systems is the leading global manufacturer of sensors, transducers, control peripherals and web browser based IP appliances. MAMAC products are used for HVAC and environmental controls, remote monitoring, alarming, energy metering and industrial automation. All MAMAC products are manufactured in the USA. WARRANTY: MAMAC Systems, Inc. and its subsidiaries (hereinafter referred to as MAMAC Systems) warrants its products to be free of defects in material and workmanship for a period of five (5) years from date of shipment. If a unit is malfunctioning, it must be returned to the factory for evaluation. A return authorization number (RMA) will be issued by the customer service department and this number must be written or prominently displayed on the shipping boxes and all related documents. The defective part should be shipped freight pre-paid to the factory. Upon examination by MAMAC Systems, if the unit is found to be defective, it will be repaired or replaced at no charge to the customer. However, this warranty is void if the unit shows evidence of being tampered with, damaged during installation, misapplied, misused, or used in any other operating condition outside of the unit s published specifications. MAMAC Systems makes no other warranties or representations of any kind whatsoever, expressed or implied, except that of title. All implied warranties including any warranty of merchantability and fitness for a particular purpose are hereby disclaimed. User is responsible to determine suitability for intended use. LIMITATIONS OF LIABILITY: The remedies of buyer set forth herein are exclusive and the total liability of MAMAC Systems with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the product upon which liability is based. In no event shall MAMAC Systems be liable for consequential, incidental or special damages. MAMAC Systems reserves the right to change any specifications without notice to improve performance, reliability, or function of our products. Every precaution for accuracy has been taken in the preparation of this manual, however, MAMAC Systems neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the product in accordance with the information contained in the manual. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876