FCHM Hydromatic Pump Control Module

Similar documents
Pressurisation units & expansion vessels

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

AS950 REFRIGERATED SAMPLERS

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

CMT MANUAL 6. NMC SENSORS

Installation & Technical Guide. Domestic & Commercial.

F25 CORROSION RESISTANT FLOW SWITCHES

Chlorine gas leak detector

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

ISIS SAFETY SYSTEM Installation guide

RE-PR3-E-27 3-Phase Panel Mount 27kW

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Trade Product List 2013 BIOMASS ACCESSORIES

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

EVAPORATIVE COOLER PUMPS

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

Sitron s CF Line of Flow Switch Monitors

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

The Professional s Choice

INTRODUCTION / TABLE OF CONTENTS

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Installation, operating and servicing instructions

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

MEGAFLO HE Iss 1

Oxygen Sensing Solutions

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

D3000. Installation & Setup Guide

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

Controller Specification Sheet

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

INSTALLATION & OPERATION MANUAL

AQUAIR S SERIES. of Water to Air Space Heaters INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONSS. Aquair S-10 Aquair S-16 Aquair S-20

Fill Point, Level Gauges, and Control Range

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Models Series Series

Unvented Electric Water Heater 10/15 litre Undersink

Zip InLine Electronically controlled instantaneous water heaters

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Broag Pressurisation equipment

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

ZIP WATER HEATING 100 ZIP INSTANTANEOUS WATER HEATERS 106 INSTANTA WATER BOILERS 107 ZIP HYDROBOIL WATER BOILERS 108 ZIP HYDROBOIL PLUS WATER BOILERS

Bristol Babcock Oil Content Monitor "oil in water"

INSTALLING AND USING THE KELCO F50 PUMP CONTROLLER

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Ultrasonic Proximity Sensor

UFM-T100H US ES CA Power Alarm Test TM

Cable Actuated Sensor Industrial Incremental Encoder Output

MAINTENANCE AND SERVICE GUIDE

SUBMERSIBLE WATER PUMPS

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Installation and User Instructions HS10U, HS15U.

Installation Instructions & Operating Manual. Heat Exchanger PLEASE READ CAREFULLY BEFORE INSTALLING. Incorrect Installation Will Affect Your Warranty

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

Low Temperature Zirconia Oxygen Analyzer

Metering systems 0548EN April 2014

Bulletin , March Electric Hot Gas Bypass Valves

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Construction Electrical

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

Intelligent addressable fire alarm control panel

OPERATION & MAINTENANCE INSTRUCTIONS

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

A/23 MFFI - A/27 MFFI

Manual / Handbuch Spare parts list / Ersatzteilliste

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

OPTISENS TUR 2000 Technical Datasheet

INSTALLATION & TECHNICAL MANUAL

PT9420 (Extended Range)

Models Series Series

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

M7100 Pressure Transducer

U5700 Submersible Liquid Level Pressure Transducer

AS950 PORTABLE SAMPLERS

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Operating Instructions

Cable Actuated Sensor Industrial User Scalable VDC Output

DP86 Constant Voltage with Fitting

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

Transcription:

FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to allow optimum performance of gas boilers or heaters, while preventing cycling and consequent temperature variations in the various appliances. Description A compact unit, which combines all the functions of a complete pressurising system, ie. Pressure Switch, Dry Running cut-out, Control Panel, Pressure Reservoir and Non-return Valve. The system employs a hydraulic chamber, equipped with a damping system to protect against water hammer, and a patented electromechanical control board, to be connected to 240Vac power source, with an internal 24V secondary circuit. Compared with conventional systems this is not only more compact, but easier and quicker to install, and makes for significant energy savings and reduced pump wear. It is also maintenance free, as the pressurisation unit does not require precharging with air. This system combines the versatility and control of conventional pressure switches with the advantages of pressure/flow switches. Avoids the need for pressure reservoirs, along with their associated maintenance costs. System enables maintenance of constant flow, elimination of shock loads, totally independent management of the electric pump, and can regulate start-up pressure between 1 and 3.5 bar. System shuts down pump if water supply fails, or the flow falls below 1.5L/min. Units must be mounted with the inlet & outlet aligned within 5 of vertical. SPECIFICATION Supply voltage 240Vac 50-60Hz Max operating power 1KW IP Rating 55 Max pressure 10 bar Max flow rate 100 l/min Max fluid temperature 55 C Max ambient temperature 55 C Minimum start-up pressure adjustable 1-3.5 bar Pump shutdown Flowrate 1.5L/min. Minimum output pressure = start-up pressure plus 0.5 bar Body material reinforced Polyamide 30% Membrane material EPDM Every effort has been made to ensure that the descriptions and specifications quoted are correct, however, no liability can be accepted for any errors or omissions in this data. The detail specifications are subject to change without prior notice. FCHM2000UK Visual indication and manual reset for water circuit faults, caused by low pressure or flow. Control of circuit pressure by differential pressure switches, which can be set from 1 to 3.5 bar for the minimum pressure. Auxiliary fuse to protect the pump control circuit. Crydom Magnetics Ltd 7 Cobham Road Ferndown Industrial Estate Wimborne Dorset BH21 7PE Tel: +44 (0) 1202 897969 Fax: +44 (0) 1202 891918 magnetics@crydom.com www.crydom.co.uk

FCHM Hydromatic Pressure Regulator FCHM SCHEMATIC Pressure Vessel Dumper System Adjustable Max. Pressure DISCONNECT POWER BEFORE OPENING 164mm RESET M IP 55 MAX 55 C MAX 10 bar - 1 MPs 230 V 50-60 HZ MAX 1KW PUMP POWER FAILURE Adjustable Min. Pressure 1" BSP Foot Valve Dry Running 215mm Control Panel WITHOUT FCHM Pressure Vessel Dry Running Press Switch Max. Press Press Switch Min. Press Control Panel Foot Valve WITH FCHM

FCTE Pump Dry Running Sensor The FCTE is a heat sensor, which is attached to the outlet pipe from a pump. This device works by reacting to the temperature at the outlet of any centrifugal type pump, which will rapidly rise past 45 C if the inlet water level falls below the centre line of the inlet. The unit will cut off the electrical supply to the pump, so protecting it from damage. Manual resetting of this unit allows the pump to restart. SPECIFICATION Set Temperature 45 C 113 F Switching voltage max. 250Vac Switching current max. resistive 16A Pipe diameter range 20-200mm IP Rating 21 TE thermostat Heat accumulation zone due to vapour formation TE thermostat also protects the seal T E Prevents dry-running of pump Prevents overheating of seals High power switching capacity Level of water when TE cuts in Dia. min 20 max 400 Spring clip fixing sensor to pipe Every effort has been made to ensure that the descriptions and specifications quoted are correct, however, no liability can be accepted for any errors or omissions in this data. The detail specifications are subject to change without prior notice. FCTE2000UK Crydom Magnetics Ltd 7 Cobham Road Ferndown Industrial Estate Wimborne Dorset BH21 7PE Tel: +44 (0) 1202 897969 Fax: +44 (0) 1202 891918 magnetics@crydom.com www.crydom.co.uk

FCTE Pump Dry Running Sensor INSTALLATION Top View 72 46 reset button T E heat sensor 46 64 brass strip diameter. min 20 max 400 indicator light cable entry pipe spring clip fixing sensor to pipe reset button indicator light cable entry 46 brass heat conductor strip heat sensor Side View 50 20 A - A three-phase motor pump protection pump thermic relay examples of positioning 16 A 250V TE thermostat 250V single - phase motor pump protection

Flow Switch Series Our range of Flow Switches are reed switch based devices which are manufactured in Acetal resin. These switches are designed for use in liquid flow systems up to 10 Bar pressure. Advanced design ensures minimal fluid flow restriction. ELECTRICAL SPECIFICATIONS Contact form ALL TYPES VA Rating 15 N/O Switching Voltage AC 240 Switching Voltage DC 120 Switching Current maximum A 1.0 All ratings are for resistive load only TECHNICAL SPECIFICATIONS FS15A FS15LF FS22A Operate Flow Rate* litres/min 2.0 0.90 3.75 US gals/min 0.53 0.24 0.99 Release Flow Rate** litres/min 0.3 0.25 1.40 US gals/min 0.08 0.07 0.37 * The switch will have operated when the flow rate rises above this value. ** The switch will have released when the flow rate falls below this value. Installation Flow switches can be mounted horizontally or vertically. As the operating piston is returned to it's original position by gravity the cap must always be upwards. Greater operate flow sensitivity is achieved with vertical installation. Supplied with 25cm Cable. OUTLINE DIMENSIONS FS15 15mm (0.59") FS22 22mm (0.87") Maximum Operating Pressure 10 bar. (140 PSI) Low flow version available WRAS approval Temperature rated to 85 C (185 F) 107mm (4.21") 114mm (4.48") 56mm (2.20") 58mm (2.28") Every effort has been made to ensure that the descriptions and specifications quoted are correct, however, no liability can be accepted for any errors or omissions in this data. The detail specifications are subject to change without prior notice. Crydom Magnetics Ltd 7 Cobham Road Ferndown Industrial Estate Wimborne Dorset BH21 7PE Tel: +44 (0) 1202 897969 Fax: +44 (0) 1202 891918 magnetics@crydom.com www.crydom.co.uk

Flow Switch notes General Note These flow switches are designed for use in low pressure, hot or cold, water systems. They may also be used with alcohol or dilute weak acids, including organic acids, up to a maximum concentration of 5%, at ambient temperatures. N.B. These switches are not suitable for used with any type of chlorinated liquid. Installation Note Check the free movement of the switch plunger, before installation, by gently shaking the switch. The Flow direction is indicated by arrows moulded on the flow switch body. These switches may be installed, either vertically or horizontally, using compression fittings. The cable entry cap should always be upwards. N.B. Care should be taken, when using metal compression fittings, to avoid overtightening the fitting onto the flow switch body. The cap should not be unscrewed from the body as the components are factory present and can not be set by the user. Electrical Caution Do not put strain on the connecting wires, as this may cause damage to the switch. The use of plastic plumbing fittings may affect electrical earth continuity bonding, as required by IEE regulations. Please consult a qualified electrician, if in doubt. Pressure loss There will be a pressure loss due to the restriction caused by the flow switch. This will increase, with the flow rate, as shown on the chart. Pressure Loss Fig. 1 600 mbar 8 p.s.i. 500 7 257-076 338-9823 257-082 400 6 5 300 4 200 3 2 100 1 0 0 20 40 flow rate 60 80 100 litre/min

flowsonic Ultrasonic Flow Meter This innovative design provides a high accuracy, non-invasive, flow measurement device at a fraction of the cost of other current non-invasive systems. The unique measurement technique automatically compensates for viscosity and temperature variations. The measurement of flow is by ultrasonic transit time in-line cell. The flow path is designed to minimise pressure drop and, having no moving parts within, will not clog or jam. The flowsonic sensor also allows contaminants to pass through without affecting its performance. The flowsonic sensor can be supplied with either a 0-5Vdc analogue output, or a pulsed 5V output. Technical Specifications UF10V UF10P UF25V UF25P Max. flow L/min 10 25 Min. flow L/min 0.1 0.25 Output 0-5VDC Pulse 0-5VDC Pulse Performance UF10V UF10P UF25V UF25P Accuracy 3% of reading or ±0.1L/min ±0.25L/min Repeatability 1% of reading or ±0.05 L/min ±0.1L/min Linearity The flowsonic meter can be used, in addition to flow rate measurement, for very accurate batch control of liquids in processes, such as chemical dosing or food processing. Accurate dispensing of drinks over the counter or in vending machines can be achieved by interfacing this flow meter with the dispensing system. Interface UF10V UF10P UF25V UF25P Connection Supply Output load Operation Principle Ultrasonic transit time in-line flow cell Temp. range (fluid) -10 C to 85 C Continuous fluid sound 1% of full scale Resolution better than 0.05L/min 0.1L/min Reverse flow 0-10L/min 0-25L/min Response time Better than 0.4s 3 wires (RED input, BLUE common, GREEN output) 7-15VDC (input current <60mA @ 9VDC) 100k (for 4.8VDC output, lower impedance loads will reduce maximum output voltage) Output 0-5VDC 1500 pulses/l 0-5VDC 752 pulses/l Max. output 5VDC 250 pulses/sec 5VDC 314 pulses/sec Min. output 0VDC 0 pulses 0VDC 0 pulses Maintains performance regardless of fluid type, temperature or viscosity for speed measurement fluids with sound speeds 1250-1750 m/s Non-invasive sensor technology No moving parts Automatic viscosity and temperature compensation Unaffected by fluid contaminants Low pressure drop Push fit connection option Crydom Magnetics Ltd 7 Cobham Road Ferndown Industrial Estate Wimborne Dorset BH21 7PE Tel: +44 (0) 1202 897969 Fax: +44 (0) 1202 891918 magnetics@crydom.com www.crydom.co.uk

flowsonic Ultrasonic Flow Meter Sound transmitted in direction of flow is accelerated; sound transmitted against flow is decelerated. The resulting time difference is proportional to flow and converted by a microcontroller into an output signal. Liquid Flow Ultrasound Flow characteristics Dimensions Pressure drop (bar) 1.4 1.2 1 0.8 0.6 0.4 0.2 A B A B C D E 62mm 45mm 90mm 33mm 3/8 BSP 0 0 5 10 15 20 25 30 35 40 Flow (L/min) C D Physical characteristics Flow tube material Glass filled plastic, Grivory HTV-4X1 (WRAS approved) Flow tube internal diameter 12.5mm Connection thread 3/8 BSP Internal bore of connection 10mm Pushfit adaptor (to fit 1/2 OD Tube) John Guest Speedfit PI451613S Maximum pressure 15 bar Case material Nylon 66 Case integrity Ultrasonically welded, not liquid proof Connection 6 core shielded, PVC sheathed, 50cm long standard Ordering Code Series Flow range (10 = 0 to 10L/min) (25= 0 to 25L/min) UF 10 P 050 Cable length (cms) Output (P = pulse, V = volts)