DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

Similar documents
Installation and servicing instructions

CalMag Filter Installation Instructions

CalMag Heating Pack Installation Instructions

PRODUCT GUIDE. High performance heating system filter Improves energy efficiency Captures magnetic and nonmagnetic.

Greenstar System Filter

Electronic Thermostat With RF

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

Eliminator TotalGuard Installation Manual

Installation and Servicing Instructions

Model: RT310. Installation Manual

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

For commercial & industrial systems. Large volume dirt collection capacity

B OILER MAG XT. 2 flanged - COD flanged - COD flanged - COD flanged - COD flanged - COD.

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Digital Room Thermostat

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

it500 Internet Thermostat INSTALLER MANUAL

Model: RT310RF. Installation Manual

Model: RT510RF. Installation Manual

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF

Installation, commissioning and servicing instructions

Digital Thermostat Models: VS30W and VS30B

CPC-180-ABNAB. 180 litres, 535mm x 1550mm high

SUNOCO Heat Transfer Fluids

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

Installation Instructions Flute Tap Range

APPLIANCES CONTROL SECURITY HEATING

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS WARRANTY

BMW E36 Thermostat Removal And Coolant Flush

HEAVY DUTY BRASS SHOWER PUMPS

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Rycroft Supapac Plate Heat Exchangers

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

Enzo Concealed Shower Mixing Valve

INSTALLATION & TECHNICAL MANUAL

Installation, Operation & Maintenance Instructions

Troubleshooting the MPH 24FP Series Pedestal Hydrant

4 in 1 Digital Thermostat Control

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

Installation Instructions For Monsoon Universal Twin Pump

Pop-up Clicker Drain Installation and User Guide

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Go Greener, with Gas.

Installation Instructions For Monsoon Universal Twin Pump

Flipside Handshower and Showerhead Installation and User Guide

Boiler protection kit guide

Commercial product range

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

General System Layout Sketch

Manual / Handbuch Spare parts list / Ersatzteilliste

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS

Installation, Operation & Maintenance Instructions

OPERATOR'S MANUAL CD 400 / CD 500

Winchester Heated Towel Rail. Fitting Instructions

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Installation, Operation & Maintenance Instructions

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Beautifully Traditional

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Singulier Spout Tube Basin Mixer Installation and User Guide

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

SYSTEMS for CATALYTIC FILTERS

Installation, Operating and Servicing Instructions

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Operation, Maintenance and Installation Manual

Drinking Water Purification Systems

SYSTEM MANUAL Description

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

568X, 587X, 588X Series

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Boiler. Introducing the NEW RT520 / RT520RF. Thermostats PLUST

CP-JR STILL WATER CHILLER SYSTEM DESCRIPTION

METRO BATH FILLER MOUNTED CHR

ERGOMAX 7 INSTALLATION

Installation & Service Guide

Puro Mini Dual Control Shower Mixer PU90010CP

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

External Module Floor Standing Condensing Oil Boiler Range ADDENDUM ATTENTION INSTALLERS - UPDATED INFORMATION!

Intatherm Safe Touch Basin Tap IT1008CP

Transcription:

OPERATION MANUAL Y NT Y YEA Full Flow Magnetic Filter YEA RW ARRA NT DEFENDER FullFlow Flow Magnetic Full Magnetic FilterFilter DEFENDER Models: MD22A 5 5 RW ARRA

In the SALUS MD22A box: INTRODUCTION Today, high efficiency boilers offer excellent performance for heating systems, however this performance can be eroded significantly if little attention is given to the cleanliness of the complete central heating system. Historically the majority of systems suffer from iron oxide contamination, which takes the form of sludge deposits which are caused by corrosion of the heating system. The iron oxide particles vary in size and the sub-micron particles are present in the system fluid continuously during system operation. The oxide particles can cause premature failure of valves and pumps and boiler efficiency is reduced dramatically as the particles contaminate the boilers heat exchanger, and the complete system pipework. The SALUS Mag Defender offers system protection and increased efficiency, as it has been designed to remove the suspended iron oxide particles without reducing flow rate through the system. Installation is simple; isolation valves rotate 360º so a number of location options can be facilitated. An added advantage to installers is the bottom mounted valve for servicing. Once isolated the bottom valve allows the easy discharge of contaminants. The main body is 500mL, which allows the installer to add the correct amount of corrosion inhibitor when the isolation valves are closed. 2 MD22A INSTRUCTION MANUAL

QUICK REFERENCE GUIDE How to install 110mm 154mm How to service and clean INSTALLATION In order to achieve the best protection for the boiler, it is recommended that the Mag Defender is fitted after the last radiator before the boiler. Header Tank Boiler Vent Pipe Pump Boiler RETURN RETURN MD22A INSTRUCTION MANUAL 3

In determining a suitable location for installation, it is important to ensure you allow adequate access for servicing. The following instructions are designed to assist engineers in the safe and effective installation and servicing of the SALUS Mag Defender and should be followed at all times. Any queries arising from either installation or servicing, contact SALUS Controls direct on 01226 323961. Dos: Install the filler upright to enable the device to be fully evacuated of air during commissioning. Pipe runs are vertical, horizontal or any angle in between. The inlet and outlet can also be swapped to suit. Where the device is fitted to the metallic building structure earthbonding continuity is required around the device. All bonding connections must be accessible and labelled Safety Electrical Connection - Do Not Remove Don ts: Magnets may affect or interfere with sensitive mechanical and electronic instruments such as heart pacemakers, computers/magnetic media and watches. Always keep magnets at least 300mm (1ft) away from such equipment. NEVER close the INLET or OUTLET isolation valves, or UNDO the lid when the pump is running! 4 MD22A INSTRUCTION MANUAL

Release system pressure then drain the pipe run where the device is to be located (it may be necessary to drain the whole system). When installing below a boiler or other object, allow 250mm clearance from the top of the canister to beneath the object, to enable the lid assembly to be removed when servicing. The device has been designed to facilitate various inlet and outlet configurations. Most configurations will require Elbows. For soldering we recommend 28x Yorkshire Solder Ring Elbow YP1222mm (code08290), or for compression we recommend 2 Yorkshire copper KS61522mm (code 61124K) and the fitting instructions (which follow) are based around dimensions of these elbows. For clarity the recommended solder and compression fittings require the same dimension of cutout. Vertical pipe run: Measure and mark a 110mm section for a 22mm unit, as shown below. Remove this marked section using a pipe cutter as shown. Now create 64mm and 106mm of 22mm copper pipe to attach between the respective elbow and compression fitting on the inlet/ outlet. Tip: Reuse the cut out section. Horizontal pipe runs: Measure and mark 73mm section and remove the marked section with a rotary tube cutter. Create 64mm and 134mm lengths of 22mm copper pip to attach between the respective elbow and compression fitting on the inlet/outlet. Tip: Reuse the cut out section. 1 Prepare the pipe and fittings, lubricate the olives and connect the valves on the pipe work, only hand tighten the connections at first. MD22A INSTRUCTION MANUAL 5

2 Now Loosen off the valve flange nuts and insert the rubber washers provided. (There are 2 supplied with this product). 3 Fit the drain valve assembly to the bottom of the Mag Defender making sure the outlet is at the front of the assembly and being careful not to overtighten as this may cause damage. 4 Loosely secure the Mag Defender to the valves. 6 MD22A INSTRUCTION MANUAL

5 Grip the Mag Defender and tighten the compression fittings being careful not to over tighten as this may cause damage. 6 Now the heating system is ready to be filled, ensure the inlet and outlet valves are both in the open position, with the drain valve in the closed position, and then run the central heating system. NOTE: Drain valve closed 7 Bleed through top air vent, bleed the MD22A again after the system has reached temperature. Take care as the water may be hot. Always service (see page 8) the filter before leaving the premises. The Mag Defender spanner can be left with the customer. MD22A INSTRUCTION MANUAL 7

SERVICING 1 Important Before carrying out any servicing work, turn off electrical supply to the boiler and let the water cool down to a safe working temperature. Using the Mag Defender spanner provided turn both isolation valves to the OFF position. 2 Remove magnet and put in a safe place. 8 MD22A INSTRUCTION MANUAL

3 After approximately 30 seconds, remove drain valve cap and use to open drain valve. Have bucket or pipe connection ready to collect debris. 4 Open inlet to flush out debris. 5 Once all debris has been flushed re-insert the magnet. MD22A INSTRUCTION MANUAL 9

6 Close drain valve using drain cap, ensure the cap is alligned correctly so the valve is fully closed. 7 Open outlet. 8 Replace cap on drain valve and run the central heating system. Bleed air through air vent if required. 10 MD22A INSTRUCTION MANUAL

CHEMICAL DOSING 1 After step 4 in servicing, close inlet valve. 2 Close drain valve using drain cap, ensure the cap is alligned correctly so the valve is fully closed. 3 Replace cap on drain valve. MD22A INSTRUCTION MANUAL 11

4 Using the MAG Defender spanner provided, carefully unscrew the lid. 5 Remove magnet cover and rinse under tap if required. 6 Pour a bottle of water treatment corrosion and scale inhibitor, we suggest SALUS Inhibitor. The canister will hold 500ml. 12 MD22A INSTRUCTION MANUAL

7 Re-insert magnet cover. 8 Now replace the lid onto the canister and tighten with the Mag Defender spanner. (Do not over tighten). 9 Re-insert magnet. MD22A INSTRUCTION MANUAL 13

10 Open the isolation valves and start the heating system. 11 Bleed through top air vent, bleed the MD22A again after the system has reached temperature. Take care as the water will be hot. Always service the filter before leaving the premises. The Mag Defender spanner can be left with the customer. 14 MD22A INSTRUCTION MANUAL

IMPORTANT Ensure that the Standard Electrical Best Practice guidelines are followed when installing Mag Defender. A copy of these guidelines can be found at www.hse.gov.uk/electricity. The inlet and outlet on the Mag Defender are reversible and there is no flow restriction. Following installation, don t forget to complete the warranty card. Alternatively, complete the registration online at www.salus-tech.com. Faulty components must be returned under the SALUS warranty process. NOTES MD22A INSTRUCTION MANUAL 15

QUESTIONS AND ANSWERS Q A Q A Q A Q A Where can I fit the Mag Defender? In order to achieve the best protection for the boiler, it is recommended that the Mag Defender is fitted between the last radiator and the boiler (see diagram on Page 3). Which connection on the Mag Defender is the flow and which is the return? The inlet and outlet on Mag Defender are reversible and there is no flow restriction. How often do I service the Mag Defender? Servicing is required once a year with the annual boiler service. Can I use chemicals with the Mag Defender? Yes, you can use any chemical on the market with Mag Defender, however we recommend you use SALUS LX products with the Mag Defender. 16 MD22A INSTRUCTION MANUAL

Q A How long will the Mag Defender last? Mag Defender has been developed to last for the lifetime of the boiler, normally ten years. It provides continuous protection and comes with a five year warranty. Q A How do I isolate the valves? Simply turn the valves to the marked OFF position using the spanner provided. Important: Remember to switch off the electrical supply to the boiler when servicing the Mag Defender. Q A Will the Mag Defender affect my pacemaker? As with all magnetic products, if you have a pacemaker caution should be taken when handling the Mag Defender at all times. When the Mag Defender is installed, the magnetic field outside the canister is approximately one tenth of an average fridge magnet. MD22A INSTRUCTION MANUAL 17

WARRANTY SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product. Y E A R 5 W A R R A N T Y Customer Name:...... Customer Address:............ Post Code:...... Tel No:... Email:...... Engineers Company:...... Tel No:... Email:... 18 MD22A INSTRUCTION MANUAL

For more products in the SALUS range visit... www.salus-tech.com MD22A INSTRUCTION MANUAL 19

Specification and contents Nylon Compression Cap Hydrolysis resistant Nylon Lid assembly with EPDM O ring 500ml hydrolysis resistant circulation chamber Neodymium magnet assembly, hermetically sealed in SSTL304 ½ BSP drain valve 22mm compression Inlet and outlet 360 swivel isolation valve (x2) www.salus-tech.com Sales: Technical: Also Supplied: Mag Defender Spanner Instruction manual including warranty form SALUS DOC No. 00004 VER020 Email: sales@salus-tech.com Tel: 01226 323961 Email: tech@salus-tech.com Tel: 01226 323961 SALUS Controls plc, SALUS House, Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP