OR Replacement Instructions Heat Exchanger Assembly, ASME

Similar documents
Ti/Lx 150 ASME HX ASSEMBLY

Detailed Cleaning Instructions

TECHNICAL INSTRUCTIONS

Heat Exchanger Block Replacement Instructions

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

HX Field Replacement Kit

Evergreen Liquid Propane Conversion

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE

INSTALLATION INSTRUCTIONS

FSB Series II Gas-Fired Hot Water Induced Draft Boilers

TECHNICAL INSTRUCTIONS

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

INSTALLATION INSTRUCTIONS

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

TECHNICAL INSTRUCTIONS

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Crown Boiler Company

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

Please read this manual completely before attempting to install, operate or service this equipment.

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Installation Instructions ZUG30 Heater Kit/Cover

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

Installation Instructions for the PITCO Self-Cleaning Burner System

Ceiling Fan Blade Arm Replacement

HOT WATER BOILER ( MBH)

IMPORTANT SAFETY INFORMATION

User s Information Manual

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

INSTRUCTION AND REPAIR MANUAL

RESIDENTIAL GAS WATER HEATERS

Heater with Air Conditioning. E-Series Ford Aeromaster

COMMERCIAL 24 VOLT FLUE DAMPER

MODEL : WDP4* / LWP-277*

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

INSTALLATION INSTRUCTIONS

KIT CONTENTS Ref Qty Part Description Part Number

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

TECHNICAL INSTRUCTIONS

Replacement parts. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS REPLACEMENT PART NUMBERS. REINSTALL Jacket door

GV Series 4 Section Assembly

SERVICE MANUAL Troubleshooting Guide and Instruction for Service

USER'S INFORMATION MANUAL

Prestige Gas Vent Stainless Termination Kit

EcoVision Door Manual

LGB Gas fired boiler

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

TECHNICAL INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

USER'S INFORMATION MANUAL

THERMOSTAT RETROFIT INSTRUCTIONS

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Table of Contents. Models/Tech Data Sheet Location. Grille/Filter Removal. Power Supply. Fan Operation Adjustment. Temperature Limiting Switches

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

Preparing the 6850 Series II GC for 597x MSD Installation

Installation. Leveling

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

INSTALLATION INSTRUCTIONS

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

Sunpak Infrared Heater. Model S34 TSR

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

HOT WATER BOTTLE BATH PART NUMBER

PVK-80 Power Vent - Installation Instructions -

Ultra Boiler Series 1 & 2 Jacket Parts

USER'S INFORMATION MANUAL

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

USER S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS

TECHNICAL INSTRUCTIONS

Fireboxes: (NL)FB32C, (NL)FB36C, FB42C, (NL)UV32C, CGFB32C and CGFB36C Series. Stoves: CSDBN, SDVB, MSDVB MSTD, CDV, S39T and S26T Series

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Water Distiller Service Manual

SERVICE MANUAL. Atmospheric ECO-MAGNUM SERIES Ultra Low NOx Gas Water Heaters. Troubleshooting Guide and Instructions for Service

PrecisionTemp Shower-Mate

MAINTENANCE AND SERVICE GUIDE

Flammable Vapor Ignition Resistant Water Heater

Vitodens 100W WB1B - Service and Maintenance

V Refrigeration Module

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

INSTALLATION INSTRUCTIONS

Summer Breeze Heater Service Manual

Section 12 - REPLACEMENT PARTS Use only genuine LAARS replacement parts.

RAYPAK ILLUSTRATED PARTS LIST

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

GB162 Concentric Horizontal Vent Kit

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

INSTALLATION INSTRUCTIONS

Niles Steel Tank Hot Water Generator Installation and Operation Manual

Transcription:

NY Thermal Inc. Tel: (506) 657-6000 Toll Free: 1-800-688-2575 Fax: 1-506-432-1135 Web: www.nythermal.com Email: info@nythermal.com Applicable Boiler Models Ti100-150(C) (ASME Models) Ti200 Lx150(ASME Models) Matrix M100(V) (ASME Models) Kit Contents 83012 83012-1 OR 82597 Replacement Instructions Heat Exchanger Assembly, ASME c/w Burner Door and Flue Box 83012 Heat Exchanger Assembly Ti100-150, Lx150, Matrix M100(V) 82054-2 (84299) Venturi Gasket, Cork 82766 Blower Gasket (C/W Pn#83012) 83291-1(100.3/150.3) Flue Adapter Kit (C/W Pn#83012) 83140 Flame Probe Wire Kit Contents 82597 82597 Heat Exchanger Assembly (Ti200) 82719 Blower Gasket (C/W Pn#82597) 83291-1(200.3) Flue Adapter Kit (C/W Pn#82597) Tools Required Pliers Phillips #2 screwdriver Flat Screwdriver ¼ nut driver or wrench 5/16 nut driver or wrench 10mm wrench ½ Wrench 7/16 Wrench 9/16 Wrench Pipe wrench Torx T25 Torx T20 Screwdriver Saw to remove venting Adjustable wrench This boiler must be service by a qualified heating technician. Failure to properly maintain or service this appliance may result in property damage, serious injury to occupants or, death. The installation of this kit must be performed by a qualified boiler technician. Installing this kit without the proper background and training is hazardous and may result in 1

property damage serious injury or death. Disassembly Instructions Boilers: 1) Turn off power and gas to the boiler. 2) Drain the boiler: use a wet/dry vacuum to help remove excess water. 3) Remove the exhaust venting. 4) Remove the gas line from the gas valve. 5) For Lx boilers Refer to page 6, Matrix boilers refer to page 9. Disconnect the supply and return piping from the heat exchanger. Return 1 Supply 2 Flue adapter Field Wiring Remove field wiring. Remove the jacket top and flue adaptor assembly. 2

Disconnect the air inlet from the venturi. 3 Remove the vinyl tube from the gas valve. Vinyl tube connection Venturi 4 Remove all the wiring attached to the burner door, blower, gas valve and safety limits. 3

5 Remove the hold down clips and brackets. Loosen the left side of the boiler jacket. 6 Remove the upper heat exchanger mounts. Remove the lower heat exchanger support over the condensate tubing. Remove condensate tubes from the bottom of the heat exchanger. Remove the heat exchanger. Do not over-tighten the nuts on the upper heat exchanger mounts during reassembly. Over tightening could cause a leak which could cause property damage. Transfer the blower motor, gas valve, and sensors to the new heat exchanger 4

Gas Leakage: Failure to properly reconnect the gas line and check for leaks may result in gas leakage causing serious injury or death. Failure to properly attach the venting or condensate drain and check for leaks, may cause flue gas leakage causing serious injury or death. Failure to correctly attach and seal the boiler piping will result in water leakage causing property damage. Transfer sensors and safety limits from the old heat exchanger to the new heat exchanger. Safety limit wiring shown in figure 7. Ti and Matrix Boiler Safety Limit Wiring. Pressure Switch Stack Limit 7 Safety Limits- Failure to correctly install and wire the safety limits on the replacement heat exchanger may result in a boiler malfunction causing injury or death. Manifold Limit 5

Disassembly Instructions Lx: Lx150 Disconnect the supply and return piping from the heat exchanger. 8 Supply and return 9 Lx150 Remove display and display housing as an assembly. Remove front jacket top. 6

Lx150 Venturi 10 Remove wiring attached to the burner door, blower motor, gas valve, and safety limits. Remove the air inlet from the venturi. Remove the condensate tubing from the Y fitting. Y fitting 11 Flue adapter Lx150 Remove the flue adapter from the flue box. Remove the brackets. Remove the lower heat exchagner that coveres the condensate tubeing. Brackets 7

Lx Burner door Burner is keyed 12 Ti Burner door Flame rod location Lx 150 Only: Remove the burner door assembly from the new heat exchanger and replace it with the original door. The new burner may be used with the old burner door. Inspect the burner door gasket and refractory for damage and replace them as necessary. Failure to install the original Lx burner door, may result in a boiler malfunction leading to boiler malfunction causing serious injury or death. Failure to replace damaged or excessivly worn gasets or refractory may result in a boiler malfunction lead to, flue gas leakage or fire causing serious injury or death. Lx150 Remove the upper heat exchanger mounts. 13 Remove the heat exchanger. Do not over-tighten the nuts on the upper heat exchanger mounts during reassembly. Over tightening could cause a leak which could cause property damage. Transfer the blower motor gas valve, and sensors to the new heat exchanger. Install the new heat exchanger in the reverse order. Gas Leakage: Failure to properly reconnect the gas line and check for leaks may result in leakage causing serious injury or death. Failure to properly attach the venting or condensate drain and check for leaks, may cause flue gas leakage causing serious injury or death. Failure to correctly reattach and seal the boiler piping will result in water leakage causing 8

property damage. Matrix Disconnect the supply and return piping from the heat exchanger. 14 15 Matrix Remove wiring attached to the burner door, blower motor, and gas valve. Remove the air inlet from the venturi. Venturi Remove the wiring attached to the safety limits. Refer to Page 5 for safety limit wiring. 9

Matrix 17 Remove the condensate tubing from the Y fitting. Remove the lower heat exchanger support. 17 Matrix Remove the flue adapter from the flue box. Remove the brackets. Remove the heat exchagner. Transfer the blower motor, gas valve, and safety limits to the new heat exchanger. Install the new heat exchanger in the reverse order. Gas Leakage: Failure to properly reconnect the gas line and check for leaks may result in leakage causing serious injury or death. Failure to properly attach the venting or condensate drain and check for leaks, may cause flue gas leakage causing serious injury or death. Failure to correctly reattach and seal the boiler piping will result in water leakage causing property damage 10