Project demonstrates benefits of traceable on-line measurement of siloxanes in industrial biogas Solving the siloxane measurement problem

Similar documents
Uses Fleet fueling stations or CNG as vehicle fuel Local power generation for Turbines, Engines or Boilers Augmentation to the CNG gas lines

Field Validation of an On-Line FTIR Analyzer for Measuring Total Siloxane Content in Landfill Gas

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

The leader in gas dehydration & filtration

Complex Solid Waste Air Permitting Issues

On-site Detection of Siloxanes and other unwanted VOCs in Landfill/Sewage/Biogas using Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS)

Chemistry Instrumental Analysis Lecture 14. Chem 4631

Maintaining a Biogas Purification System SARBS 1

Mobile CWA Detection and Identification. Innovation with Integrity. Mobile Mass Spectrometer MM2 CBRNE

Activity Watering and Plant Growth

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

Strategies in Optimizing Condensate Return

Emission Monitoring System

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

BUSINESS PLAN CEN/TC 249 PLASTICS

Siloxanes: Quantifying a New Emergent Pollutant in Water, Air and Soil

SILOXA FAKA Gas Cleaning System

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Challenges and Methods of Estimating a Conceptual HVAC Design

Ramon 2.2 Radon-Monitor

ELD500 PRECISION LEAK DETECTOR

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

Aquamax KF Oil Evaporator. User Manual

Inline Sludge Screens Municipal and Industrial Applications

MetroRADON project and its potential impact on mitigation practices Dobromir Pressyanov Sofia University St. Kliment Ohridski Bulgaria

Gas Temperature Measurements with High Temporal Resolution

AEROSOL SPECTROMETERS

CS744 Series: Carbon/Sulfur by Combustion

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Model S FT-IR SPECTROMETER

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

HYDROCARBONENGINEERING June June 2015

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

CALIBRATION HOW IT WORKS

An FT-NIR Primer. NR800-A-006

Problem. Can paper mill sludge be used as a fertilizer for plants and does it change the ph of the

Measurement Devices. Topic 5 - Audio 56

OPEN PATH DETECTION OF ACROLEIN LEAKS

PCT Workshop Before you leave the office

Chemtron Science Laboratories Pvt. Ltd.

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

Milano, 25 novembre 2015

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

East Park Academy Science Year 4: Living things and their habitats Overview of the Learning:

Improving Productivity, Quality and Security

CALIBRATION HOW IT WORKS

HIBC/B INTERMEDIATE BULK CONTAINER HEATER

HEAT REGENERATED ADSORPTION DRYERS

Reducing the Carbon Footprint of Existing Domestic Heating: A Non-Disruptive Approach

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Displacement Ventilation in Classrooms

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

THE COMPLETE SOLUTIONS PACKAGE

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Gas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time.

Notifier by Honeywell: SMART Detection. SMART Detection. The Ultimate in False Alarm Technology...Make the SMART choice

Huber s New Q-Press. Presented by: Steve Macomber Huber Technology, Inc.

HEAT REGENERATED ADSORPTION DRYERS

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

Application of a Reagentless Direct Conductivity Online TOC Analyzer for Clean-in-Place Verification

Frequently Asked Questions Refuse (Garbage) Rates, July 1, 2015

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

Treatment of Digester Gas

Operation and Maintenance Manual

PSA Series. Particle Size Analyzer

Nedap Cow Positioning with integrated Heat Detection and Health Monitoring

ACTIVITIES OF THE MEASURING GROUP

HEAT REGENERATED ADSORPTION DRYERS

NTC THERMISTOR SENSOR PERFORMANCE

Final Background Report. Viruses, illnesses, diseases - these are words that come to mind when most people

MAKING A LASTING MARK: Cable Identification Products

and Refrigerant Identifier

Heat Exchanger Excellence DESIGN BUILD SUPPLY INSTALL MAINTAIN.

Please read this sheet as it contains important information

Tackling the mounting e-waste problem

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Trials of Vexo inhibitor in domestic central. heating systems

LAB 8. FIGURE L8.1 A rock sculpted by wind erosion in the Altiplano region of Bolivia. FIGURE L8.2 A dust storm in Casa Grande, Arizona

Drying Simulation the most effective way to save energy

CHAPTER 1 INTRODUCTION

Responsible Care Product Stewardship for Refrigerants

Water Efficiency. Industry Specific Processes. Metal Finishing. for Commercial, Industrial and Institutional Facilities

Molekule Produces No Ozone or Other Secondary Pollutants, and Actually Reduces Ozone in the Air.

BUREAU OF METEOROLOGY

Temperature Data Logging

Homework Chapter2. Homework Chapter3

ALTAIR 5X Multigas Detector

testo 316-EX gas leak detector Instruction manual

E. Elnahrawy, X. Li, and R. Martin

Datalogging as standard

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Transcription:

Project demonstrates benefits of traceable on-line measurement of siloxanes in industrial biogas Solving the siloxane measurement problem Of all the hurdles the biogas economy has faced, the challenge of impurity measurement remains at the forefront of industrial and scientific interest. A recent project funded by the European Metrology Research program for Innovation and Research (EMPIR) has taken steps towards providing a solution to one of biggest measurement challenges in biogas quality. There are currently no standardised methods for the measurement of siloxanes in biogas or biomethane, so scientific research projects such as this are proving vitally important for underpinning the growing biogas economy. During the novel 18 month project, the UKs National Physical Laboratory (NPL) worked in collaboration with UK based company Protea to demonstrate the benefits of traceable online measurements of siloxanes in industrial biogas. The results indicate that moving towards real-time measurement provides a large advantage over more traditional methods, which have been plagued with issues. The siloxane challenge Amongst the diverse impurity content of biogas, siloxanes are amongst the most problematic both in terms of measurement challenge and their harmful effects on infrastructure. Siloxanes can cause irreversible damage to gas processing equipment, as abrasive silicon dioxide deposits are formed during combustion. The fouling of thermocouples and oxygen sensors has also been observed, causing feedback errors and efficiency loss. Siloxanes are a relatively new impurity found in biogas, as their use within household products has gradually increased over the last few decades. They are now commonly added to products such as cleaning agents, deodorants and cosmetics to improve their consistency and performance. Figure 1: Molecular structure of L2, L3, D4 and D5 siloxanes (C: black, H: white, O: red, Si: teal) Once disposed of, these products become part of the waste streams that are typically used for biogas production. Due to their volatility, the siloxanes become entrained with the biogas during the digestion stage, and must be removed to below a threshold level before the biogas can be safely used to produce energy. This total silicon limit level varies by application, and the limit values themselves are still under scrutiny at European standardisation level. The need for a new gold standard The current gold standard for siloxane quantification involves collecting samples within sampling media such as sample bags, which are then sent to laboratories for analysis, and results provided after several days. Although offline methods do not require an initial investment, over time they prove to be an expensive technique. Looking beyond the figures reveals a bigger problem, as studies have widely reported problems with the short-term stability of siloxanes within media such as sampling bags. This often leads to large differences in results when samples are sent to separate laboratories, as the sampling method fails to provide a representative view of the siloxane content. So while the laboratory based measurement techniques may be accurate, the sample they are measuring is often compromised as the technique is not fit for purpose. Spectroscopic solution

UK based company Protea has developed an instrument that utilises Fourier Transform Infra-Red (FTIR) detection to identify and quantify siloxanes in real-time. The full spectrum technique utilised by their AtmosFIR instrument also allows for the measurement of methane and carbon dioxide, which are the main biogas components. Figure 2: FTIR spectrum showing siloxanes in biogas and AtmosFIR instrument Although siloxanes appear similar to the detector, there are small changes in response due to differences between the molecules. This enables each siloxane to leave a unique fingerprint, and allows for multiple biogas components to be measured simultaneously, providing a holistic measurement solution. Traceable reference siloxane standards In order to validate Protea s FTIR technique, traceable gas standards containing siloxanes in biogas were prepared by NPL in order to provide a reference. NPL is the UK's national standards laboratory, a world-leading centre in the development and application of highly accurate measurement technology. The gas and particle metrology group has refined their techniques through over six years of biogas impurity research, and their reference standards are at the cutting edge of accuracy. Figure 3: Reference mixtures are prepared by weighing each component Traceability is vitally important, as it ensures that measurement results are valid through using an unbroken chain of comparisons back to national standards. In this case the mixtures are traceable to the SI kilogram, as components are individually weighed using high precision balances as they are added to the gas cylinder. The standards are then validated using a high precision gas chromatograph, which separates the siloxanes on a thin capillary column before detecting them with a mass spectrometer. In contrast to Protea s FTIR technique, this lab-based solution is not appropriate for performing online measurements due to its high cost and maintenance requirements. It is barriers such as this that has thus far posed a challenge to biogas upgraders, as there is often a trade-off between accuracy and cost.

Figure 4: Lab based techniques are accurate, but expensive Field trial The AtmosFIR instrument was taken to a UK based wastewater treatment plant. The plant uses anaerobic digestion to convert waste sludge into biogas, which is burnt in gas turbines to generate renewable energy. Raw biogas from the digester is upgraded using a series of activated carbon beds before it is fed to gas turbines. Figure 5: Plant schematic showing sampling points The beds undergo a nine hour regeneration cycle, in which a bed is taken off line after six hours for cleaning. The biogas flow is diverted onto a clean bed whilst the previous bed regenerates to ensure there is no interruption to the process. Real time data collected from Protea s instrument clearly captures how this regeneration cycle affects the amount fractions of individual siloxanes within the biogas. D4 siloxane in particular can be seen to follow a clear rise and fall pattern, which aligns with the bed regeneration schedule.

Amount fraction (ppm) Siloxanes measured by FTIR D3 L3 D4 L4 D5 Total SiOx 5.7 3.8 1.9 0.0 1.59 1.06 0.53 0.44 0.33 0.22 0.11 1.23 0.82 0.41 0.33 0.22 0.11 0.105 0.070 0.035 0 L2 2.46 1.64 0.82 22 Sep 23 Sep 24 Sep 25 Sep 26 Sep 27 Sep Date Figure 6: On line measurements captures the trends that grab samples may miss The real time data also captured a surprising result when it was switched to measure raw biogas (see 27 th Sep in graph). Although some of the heavier siloxanes were seen to increase as expected, the total silicon was lower overall in the raw biogas. NPL and Protea chemists have theorised that this is likely due to the chemistry of the carbon beds and a feature of aging material. After contacting the site it was discovered that the carbon beds were indeed due for replacement, which served to explain the anomalous result and highlight the advantage that continuous monitoring would provide During the field trial, NPL s traceable gas standards were used to perform calibration checks on the AtmosFIR. Traceability in instrument calibration is important for providing confidence in results, so a full lab-based validation of the AtmosFIR took place at NPL in advance of the trial. It is through this mechanism that the results are validated, through an unbroken chain of comparisons back to the SI. Figure 7: On line sampling

Conclusion The growing industry need for the fast and accurate measurement of biogas quality is a vital one to address. Impurities such as siloxanes currently have no standardised methods for their quantification, so it is important to develop new solutions to feed into future standardisation. The development and validation of on line instruments such as Protea s AtmosFIR are taking important steps in moving the biogas quality framework forward. The monitoring of individual siloxanes in real time is currently not widely practised, but in this case has proved valuable by highlighting breakthrough of lighter siloxanes in aging carbon beds. Direct on line measurement has the advantage of removing the uncertainty associated with existing sampling methods, which is widely recognised as one of the largest sources of error. This project has demonstrated that techniques such as FTIR provide a viable solution to the siloxane measurement challenge, revealing hidden trends that would have otherwise gone unnoticed and providing plant operators with quality assurance and a platform for process optimisation. The validation of measurement techniques such as this, will ensure that biomethane can play a significant role in delivering a sustainable and secure energy future. This article was written by Lucy Culleton, Higher research scientist at NPL. Visit NPL.co.uk