SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

Similar documents
SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Express Lavatory System SS-Series

SS-3N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

AV30 Advocate Lavatory System AV-Series

Express Lavatory System MG-Series

AV60 Advocate Lavatory System AV-Series

Express Lavatory System MG-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

AV60 Advocate Lavatory System AV-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

AV60 Advocate Lavatory System AV-Series

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

AV90 Advocate Lavatory System AV-Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

Installation Instructions

LD-5010 OmniDeck with WashBar 5000 Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

HL45, HL80 Thermostatic High-Low Valves

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Model Z Sundara Reef Triple Basin Hand Washing System

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation Instructions

FL-3H, FL-3L Frequency Lavatory System FL-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation Instructions

Installation Instructions

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

LVSD2 Verge Wash Basin LVS-Series

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Washfountain Application Guide

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

Model Z Sundara Float Double Basin Hand Washing System

LVQD3 Verge with WashBar Technology LVQ-Series

Installation Instructions

School Solutions Ideabook

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

LVQD1 Verge with WashBar Technology LVQ-Series

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

Installation Instructions

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation Instructions OBSOLETE

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

TMV45 & TMV80 Standard Thermostatic Mixing Valves

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Geo Series KPF-1702 / KPF-1750 Make a Bold Statement in Your Kitchen

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

DESIGN AND CONSTRUCTION STANDARDS July 2011

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

cygnet stainless Product Catalog toll free

Durability within reach

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

LA45 DISCONTINUED IMPORTANT!

PRO SERIES IMPORTANT SAFETY INFORMATION

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Product Specification

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

A. Section Joint Sealants: Seal fixtures to walls and floors.

LA60 DISCONTINUED IMPORTANT!

Distributed By: M&M Control Service, Inc SURFACE MOUNT SHOWER SYSTEMS

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

FAUCET PARTS - EXPLODED VIEW Model: K-59

Installation Instructions

Tube Clamp Submittal Information Revision A: July 25, 2013

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Transcription:

SN2003, SN2023, SN2004, SN2024 cupc Certified Reliable Push Button Activated Air Metering, Infrared, or TouchTime Control Available in a 54" or 36" Bowl Size Wall-Mounted or Floor-Mounted Standard Height Models with Air Valve Hand, Infrared or TouchTime Control are ADA Compliant Factory Tested and Shipped Pre-assembled Vandal Resistant and Easy to Clean Specifications Size and Capacity Accommodates 3 users (36" models) or 4 users (54" models) at a time, using less water, energy and space than lavs equipped with conventional faucets. The sectional sprayhead module is controlled by a push button, which actuates an air valve (hand or foot control models), an infrared sensor-actuated solenoid valve, or a TouchTime push button, which actuates a solenoid valve. Flow restrictor keeps flow rate constant at 0.5 GPM per station for all pressures. Operating range is 20-80 PSI. Construction Bowl and Pedestal All exposed materials are type 304 stainless steel polished to a #4 finish. Bowl, pedestal and access panels, frame, foot control housing; support tube; and sprayhead are heavy gauge stainless steel. Exposed fittings are chrome plated. Vandal Resistance Bowl and support tube are an integrally welded assembly, with the support tube welded to an extruded flange from bowl. Sprayhead nozzles and push buttons/infrared sensors are secured to unit from inside the sprayhead module. Air valves/solenoid valves are safely concealed inside the washfountain. Access panels are removable. All supply and waste connections are concealed within the pedestal. Standard Equipment Valves and Fittings In addition to the bowl and pedestal, the following valves and fittings are standard: Navigator thermostatic mixing valve, flexible stainless steel supply hoses and stops. Stops are 1/2" compression female. Activation Controls Air Valve Hand Control Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates one valve which, in turn, activates one station. Push button requires less than five pounds of pressure. Air Valve Foot Control Each push button pneumatically actuates a hold-open air single temperature valve with slow closing upon release of foot pressure. Push button requires less than five pounds of pressure. Infrared Control Each of the stream formers is controlled by a separate solenoid valve. Hands placed within the bowl are detected by an infrared sensor module, which activates a flow of tempered water from one spray nozzle. Shut-off is automatic after hands are removed from the detection area. The infrared sensor module uses two zone-focused infrared transmitting beams, having a detection area that does not exceed the bowl perimeter. The detection range projects 6 9 inches forward at a 30 angle to each side and reaches 15 below horizontal. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low voltage transform as standard equipment: Solenoid 24V, 50/60 Hz, 5/16" tube fitting. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Transformer Class II UL/CSA listed, 110/24 VAC hard-wire transformer designed to mount on a conduit box. Location of transformer per local electrical code. Page 1 of 6 SN2004 (Air Valve Hand Control, Backsplash) SN2004 (Air Valve Foot Control) SN2004 (Infrared Activation) TouchTime Hand Control Each low-voltage button actuates a non-hold-open, slow-closing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each push button activates one valve which, in turn, activates one station. TouchTime controls water flow at each station through the use of solid state, digital circuitry. Timing is electronically controlled at 15 seconds. Push button requires less than five pounds of pressure. Code Compliance and Certifications cupc Approval Sentry Washfountains are Uniform Plumbing Code (UPC), International Plumbing Code (IPC) and National Plumbing Code of Canada (NPC) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). Manufactured in compliance with IGC 156-2009, CSA B45 Series-2002 (R08) & ASME A112.18.1-2005/CSA B125.1-2005. ADA and TAS (Texas Accessibility Standards) Compliant All floor and wall mounted standard height models, with hand or infrared control, comply with all ADA guidelines on reaches, clearances and operation. Models with a 36" bowl and TouchTime, hand or infrared controls, in juvenile height comply with ADA guidelines for children. Floor and wall mounted models with a 36" bowl, hand or infrared controls, in standard height or juvenile height (children ages 4 to 10 or 11) comply with all TAS guidelines on reaches, clearances, and operation. Wall mounted 36" bowl models, with hand or infrared control, mounted 2" lower than standard height, comply with TAS guidelines for children ages 11 to 14 or 15. Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement. Certified to NSF/ANSI 372

SN2003, SN2023, SN2004, SN2024 Models (Must select one) Standard Selections (Must select one from each category) Drain Type (select one) A Off-line vent with supplies from below B Centrally rising vent with supplies from above Controls (select one) AST4 Hand Control Metering Air Valve IR Model Size Stations Description SN2003* 36" 3 Floor-Mounted SN2004* 54" 4 Floor-Mounted SN2023* 36" 3 Wall-Mounted SN2024* 54" 4 Wall-Mounted Infrared Activation Rough-In Dimensions for Bowl and Pedestal Wall Anchors H O AST4-F Centrally rising vent with supplies from below Off-line vent with supplies from above TT TouchTime Foot Control Hold-Open Air Valve# (SN2003 and SN2004 only) Pedestal Height (Models SN2003 & SN2004 only) (select one) STD Standard Pedestal Height JUV Juvenile Pedestal Height Supply Fittings (select one) TMA Thermostatic Mixing Valve PBV Pressure Balance Mixing Valve TL Tempered Line Supply Soap Dispenser (select one) LSD Liquid Soap Dispenser NSD No Soap Dispenser Backsplash (select one) BS Backsplash NBS No Backsplash Optional Selections Paper Towel Dispensers CTD (2) C-Fold, Multi-Fold Dispenser SFTD (2) Single-Fold Dispenser Stainless Steel Shroud (Option available on wall mounted only) SH Stainless Steel Shroud (Conceals overhead plumbing) * Models in standard height with TT (TouchTime), AST4 (Hand Control Metering Air Valve) or IR (Infrared)controls are ADA compliant # Non-cancelable, not-returnable Available with the NSD (No Soap Dispenser) option only 36: 13-3/8" (340) 54: 22-3/8" (568) 36: 13-3/8" (340) 54: 22-3/8" (568) 4" (102) 1-3/4" (44) 32-1/2" * (826) 4" (102) 24-3/4"* (629) Rough-In Notes Anchor locations for 3/8" diameter bolts, both supplied by installer. Wall mounted 54" and 36" models with TouchTime, Infrared or hand control are ADA compliant when mounted at standard height dimensions. * Subtract 4" (102) from this dimension for juvenile height. Page 2 of 6 110 Volt Electrical Box for Units with IR Activation (Recommended Location; See Local Electrical Codes Before Roughing in) 8-3/8" JUV 8" STD (203) Floor Mounted Only 9" (229) 8-3/8" JUV 8" STD (203) Floor Mounted Only Floor Mounted Only 9" (229) 4-3/4" (121) 14-3/4"* (375) 14-1/2"* (368)

Dimensions - Sentry 54" Floor Mounted Infrared Control with Optional Backsplash SN2003, SN2023, SN2004, SN2024 Dimensions - Sentry 36" Floor Mounted Infrared Control with Optional Backsplash 16-3/8" (416) 25-1/4" (641) Hand Control Hand Control 16-3/8" (416) 25-1/4" (641) Foot Control Foot Control 8-11/16"* (221) 25-1/4" (641) 2-1/4" (57) Standard height 36" and 54" models with TouchTime, Infrared or hand control are ADA compliant when mounted at standard height dimensions. * Subtract 4" (102) from this dimension for juvenile height. Page 3 of 6 4-1/8" (105) 3-1/16"* (81) 1 (476) 2-1/4" (57) 3-15/16" (100)

SN2003, SN2023, SN2004, SN2024 Dimensions - Sentry 54" and 36" Wall Mounted 54" Infrared Control with Optional Backsplash 54" Hand Control 16-3/8" (416) 35-1/4" (895) 16-3/8" (416) 35-1/4" (895) 36" Infrared Control with Optional Backsplash 36" Hand Control 26" (660) 9" (229) Wall mounted 54" and 36" models with TouchTime, Infrared or hand control are ADA compliant when mounted at standard height dimensions. * Subtract 4" (102) from this dimension for juvenile height. Page 4 of 6

Rough-In Dimensions for Drain and Supplies SN2003, SN2023, SN2004, SN2024 Type A Off-line vent with supplies from below 2-3/4" (70) Stub Up 3" (76) (Optional) Type B Centrally rising vent with supplies from above Stub Up 3" (76) (Optional) 2-3/4" (70) 1/2" Nom. Copper Tube Supplies from Above Must Be Located on These Centers to Pass Through Washfountain Shroud and Sprayhead 5" (127) 1/2" Nominal Copper Tubing Supplies 5" (127) 4-1/2" (114) Centerline of Washfountain Supplies Through Floor Stub Up 2-1/2" (64) (Optional) : Stub out to Suit Trap 36: 7-9/16" (192) 54: 8-1/16" (205) 36: 54: 9-1/4" (235) Vent from Above Centerline of Washfountain Supplies from Above Supplies Supplies and Drain Through Floor (Optional) ** Vent from Above : Stub out to Suit Trap Drain Through Floor (Optional) ** Std: 12" (305) Juv: 8" (203) ** Floor Mounted Units Only Type A Drain Supplies below Off-drain vent P-Trap furnished by others Type B Drain Supplies above Centrally-rising vent P-Trap furnished Rough-In Notes 1. Maximum flow rate required to washfountain is 1.5 GPM for Models W2003 and W2023 or 2.0 GPM for Model W2004 and W2024. Size supply lines accordingly. 2. Unit with A drain and paper towel dispensers and/or a shroud, should use H drain Rough-Ins. Page 5 of 6

Rough-In Dimensions for Drain and Supplies SN2003, SN2023, SN2004, SN2024 Type H Drain Centrally rising vent with supplies from below Type O Drain Off-line vent with supplies from above Stub up 3" (76) (Optional) 1/2" Nominal Copper Tubing Supplies 5" (127) 36: 54: 9-1/4" (235) 2-3/4" (70) 1-1/2" NPT Vent from Above 4-1/2" (114) 4-1/2" (114) Centerline of Washfountain Supplies Through Floor: Stub up 2-1/2" (64) (Optional) Vent from Above 2-3/4" (70) 1/2" Nom. Copper Tube Supplies from Above Must Be Located on These Centers to Pass Through Stub up 3" (76) (Optional) Washfountain Shroud and Sprayhead 5" (127) 36: 7-9/16" (192) 54: 8-1/16" (205) Centerline of Washfountain 1/2"Nominal Copper Tubing Supplies from Above Through Wall: Stub out to Suit Trap Supplies Supplies and Drain Through Floor (Optional) ** Through Wall: Stub out to Suit Trap Drain Through Floor (Optional) ** Std: 12" (305) Juv: 8" (203) ** Floor Mounted Units Only Type H Drain Supplies below Centrally-rising vent P-Trap furnished Type O Drain Supplies above Off-drain vent P-Trap furnished by others Rough-In Notes 1. Maximum flow rate required to washfountain is 1.5 GPM for Models W2003 and W2023 or 2.0 GPM for Model W2004 and W2024. Size supply lines accordingly. 2. Unit with "O" drain and paper towel dispensers and/or a shroud, should use "B" drain Rough-Ins. Page 6 of 6