DataSheet. Thermocouple Logger

Similar documents
DataSheet. Thermocouple Logger

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Tinytag Ultra Data Logger Manual

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD

Specifications Minimum Typical Maximum Unit

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-TC Thermocouple Data Logger with USB Interface

EasyLog Data Logger Series

ELMTEC. Kattreppeln Königslutter / /

EasyLog Data Logger Series

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

EL-OEM-3 OEM Packaged Voltage Data Logger

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface


The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Refrigerator/Freezer Thermometer

Temperature Data Logging

Refrigerator/Freezer Thermometer

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

USER MANUAL USB Multi-Function Datalogger Model RHT35

Introduction. OM-THA2

LogTag TICT - is0 Tag

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

Accessories, interfaces, sensors and complete solutions.

Accessories, interfaces, sensors and complete solutions.

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Compact Ultra Low Temperature Chamber

THERMOMETERS Dataloggers/Refrigerator

MIRADOR Real Time Monitoring

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

HOBO U14 Data Logger User Manual

ECOLOG Data logger series we prove it.

Liquid Helium Level Instruments

ISO New Product Catalog. Addendum 2014 TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Precision Infrared Thermometer. Users Manual

portable gas analyser

Global Laboratory Catalog

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

EL-OEM-3 OEM Packaged Voltage Data Logger

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Omniguard 4: Features

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Module Features are-configurable, no module jumpers to set

WH7016E Thermostat Product Manual

FLOOD SERIES DATA SHEET

2014, TempSen Electronics Company

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

iminiplus PDF User Guide Version 2.0

UTRED day Logger with display

Sirius Technologies, Inc.

Dräger Pac 6000 Single-Gas Detector

Monitoring system. testo 160 Monitoring system for the monitoring of temperature, humidity, light intensity, UV radiation and CO 2. concentration.

ST Wiring diagram. Product description. Standard temperature controller. Order number

Measuring Recording Online Monitoring Regulation Alarming

Measurement Solutions for Refrigeration Technology.

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

portable gas analyser

Model KBF 240 Constant climate chambers with large temperature / humidity range

D-TECT 3 IP. GJD260 IP Motion Detector

Measurement Solutions for Refrigeration Technology.

K100A Insertion Probe Thermometer

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

AirTest Technologies Inc.

LIBERO PDF Logger for Cryogenic Container Monitoring

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Exceptional data integrity. Complete peace of mind.

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Microtherm Heat Stress WBGT

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

THX-DL Data Logger USER & INSTALLATION MANUAL V

LTE Scientific Ltd. Touchclave-R. The dynamic new range of cylindrical-section autoclaves from LTE Scientific

ECOLOG Datalogger Series

COA-2010-F Electronic CO 2

data logger DL200H DL200D DL200L

Nardalert S3 TM Non-Ionizing Radiation Monitor

Thermohygrometer with Single Type K Input and Superheat Function

User Manual. Humidity-Temperature Chart Recorder. Model RH520

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

ECOLOG Data Sheets Status May 2015

Product Catalogue. Air and Gas Sensors. Save Life and Energy

Di-440 The Modular Analyser

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

VD8. mode VD8. Digital Compact Vacuum Meters Data Loggers

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

User Guide. Shaft Speed 6 6-Channel Shaft Speed Monitor. Calibration and Operation Software Reference UDJ701-5

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Part of the Crop Monitoring and Automatic control range. The most advanced automatic fan control and crop monitoring system available

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Transcription:

DataSheet Thermocouple Logger For Type K, J, T & N Standard & miniature plugs Burnout response Cost-effective The Tinytag Ultra 2 Thermocouple data logger uses a thermocouple sensor for the cost-effective monitoring of temperature in a wide variety of applications. Thermocouples are temperature sensors that are popular because of their versatility and low cost. They typically have a fast response time, can be very small in size and are often cheap enough to be treated as disposable. Thermocouples are available for specific applications as diverse as aluminium smelting, air temperature monitoring and food preparation. The Tinytag Ultra 2 Thermocouple logger supports four different types of thermocouple sensor and is compatible with both standard and miniature thermocouple plugs.

Tinytag Ultra 2 Thermocouple Logger Features Supports four types of thermocouple - the logger supports Type K, J, T and N thermocouples. Different thermocouple types work over different temperature ranges and are used in different applications (see the next page for further information on thermocouple types). Built-in in temperature channel - the data logger has a built-in temperature channel that allows ambient temperature to be monitored at the same time as the thermocouple temperature. This channel can be turned off to increase the reading capacity of the logger if required. Cold junction compensation - the logger uses automatic cold junction compensation, ensuring the accuracy of the logger between -10 and +70 C. Type K thermocouple included - a Type K thermocouple, that can measure from -100 to +250 C, is included with this logger. Tinytag Explorer - this logger works with the popular Tinytag Explorer software, that allows users to easily combine data from different Tinytag data loggers and to export data to other programs. The software is also used to set the type of thermocouple being used. Two connection types - the logger supports both standard and miniature thermocouple plugs. Burnout response - the logger can be set to drive readings low or high in the event of a fault with the thermocouple, highlighting that there is a problem.

Thermocouple Types The logger can be used with four types of thermocouple: Types K, J, T and N. These sensors have different characteristics and temperature ranges and are suited to different applications. Below is some guidance on selecting the best type of thermocouple for your application. Note: the temperature ranges stated in this section are the ranges supported by this logger. Thermocouples from different suppliers may have a narrower range for a given type than the figures quoted below. Type K (-270 ( to +1370 C / -454 to 2498 F) A general purpose thermocouple that can be used in most applications. A wide variety of low-cost probe types are available in this type. Generally a good choice of sensor, but Type T probes may be preferable at low temperatures, and Type N at high. A Type K thermocouple for use between -100 and +250 C is supplied with the logger. Type J (-210 ( to +1200 C / -346 to 2192 F) A popular type of thermocouple that is commonly used to monitor temperatures of inert materials and in vacuum applications. This type of thermocouple is susceptible to oxidisation so is not the best choice for damp conditions or low temperature monitoring. Also, the accuracy of this type of sensor can be permanently impaired if used above 760 C. Type T (-270 ( to +400 C / -454 to 752 F) Good for low temperature and cryogenic applications. Used widely in the food industry because of its good accuracy and because it performs well in the presence of moisture. Type N (-270 ( to +1300 C / -454 to 2372 F) Another thermocouple with a wide temperature range, this one is better suited to high temperature monitoring than the Type K because it is more stable and resists oxidisation. Common applications include engine exhaust temperatures, smelting and kiln monitoring.

Specification Features Reading Capacity 22,000 readings (approximately) Memory type Non Volatile Trigger Start Magnetic Switch Delayed Start Relative / Absolute (up to 3650 days) Stop Options When full Never (overwrite oldest data) Reading Types Actual, Min, Max Logging Interval 1 sec to 10 days Alarms 4 fully programmable; latchable Measurement Specification Thermocouple Sensor Type Type K, J, T or N Thermocouple Type K -270 to +1370 C (-454 to 2498 F) Type J -210 to +1200 C (-346 to 2192 F) Type T -270 to +400 C (-454 to 752 F) Type N -270 to +1300 C (-454 to 2372 F) Reading Resolution 0.01 C Cold Junction Compensation -10 to 70 C Accuracy Better than ±1.0 C across all thermocouple ranges when the logger is between -10 & +70 C. Note: The above accuracy figures do not include the thermocouple probe. Logger Temperature Sensor Type Response Time Reading Resolution Accuracy -40 to +85 C (-40 to +185 F) 10K NTC Thermistor 20 mins to 90% FSD in moving air 0.02 C or better Better than ±0.5 C Physical Specification IP Rating IP51 Working Temperature -40 to +85 C (-40 to +185 F) Case Dimensions Height 72mm / 2.83 Width 60mm / 2.36 Depth 33mm / 1.30 Weight 65g / 2.29oz Supplied Type K Thermocouple Temperature -100 to +250 C (-148 to 482 F) Lead length 1m / 39.37 Battery Information Battery Type Tekcell SBAA02P; SAFT LS14250 or LST14250 The logger will operate with other ½AA 3.6V Lithium (Li- SOCl2) batteries but performance cannot be guaranteed. Battery Life Greater than one year. The Tinytag Explorer software will prompt the user when a new battery is required (about a week before the battery runs flat). If the logger is being used for long term monitoring, the battery should be replaced annually. A service kit, containing a replacement battery and instructions for servicing the data logger, can be ordered using the part number SER-9500. Before replacing the battery the data logger must be stopped. Data stored on the logger will be retained after a battery is replaced.

Specification Notes If used at low temperatures the data logger should be allowed to warm to room temperature before it is opened to avoid condensation forming inside it. The IP51 rating is valid only when the logger s connector cover is fitted and the unit is orientated with its hanging tab uppermost. Trigger Start The trigger start option allows a unit to be set up as required and then started at a later time with a magnet. The position of the unit s trigger start switch is indicated by the label on the back of the logger. When the "Wait until trigger event" option is selected in the Tinytag Explorer software, the green LED on the unit will flash once every eight seconds, indicating that the unit is waiting to log. When a magnet passed over the label, the green LED will light briefly to indicate that the unit has been activated. Once activated, the green LED will flash every four seconds to indicate that the logger is recording. Calibration This logger is configured to meet Gemini s quoted specification during its manufacture. Approvals Gemini Data Loggers (UK) Ltd. operates a Business Management System which conforms to ISO 9001 and ISO 14001. Part Numbers TGU-4550 4550: Tinytag Ultra 2 Thermocouple data logger. To use these data loggers you will also require a copy of the Tinytag Explorer software (SWCD-0040) and a USB download cable (CAB-0007-USB). The following starter kit contains a thermocouple data logger, a copy of Tinytag Explorer and a USB download cable. TGU-4550 4550-SPK: Tinytag Ultra 2 Thermocouple (K/J/T/N) Starter Pack. Service Kit SER-9500 Tinytag Data Logger Service Kit We recommend that the calibration of the logger should be checked annually against a calibrated reference meter. A certificate of calibration, traceable to a national standard, can be supplied for an additional charge either at the point of purchase, or if the unit is returned for a service calibration. Issue 3 (26th January 2018)