QTC15 Temperature Controller Operation Manual

Similar documents
GTC15 Temperature Controller Operation Manual

BTC15 Temperature Controller Operation Manual

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

QMF MAINFRAME Installation Manual

INSTRUCTIONS FOR THD-U SERIES HOT AIR MATERIAL DRYERS

flexibility programmed settings.

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Static Pressure Control

7-Day. Digital Thermostat. residential. & 2-cool

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

TEMPERATURE CONTROLLER

SSV-DC user manual. Phason

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

5+2 Day. up to HEAT COOL

Oakton TEMP 9500 Advanced Multiparameter Controller

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

SC Installation, Operation & Application Guide

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Introduction... 1 System Overview... 1 System Diagram... 2

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

1 For All Programmable Digital Thermostat

TC515 and TC600 Installation Manual. a Winters company

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Intelligent Electronic Enclosure Thermal Management Systems

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

MV2 SERIES Temperature Controller. Instruction Manual

M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

RC-2000 Thermostat Installation Instructions

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

IMAGE PRESS & IMAGE PORCELAIN OVEN. 120V, 50/60 Hz Models and 230V, 50/60 Hz Models. Operator s Manual

Programmable Digital Thermostat

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Secondary Sensing System

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Oakton TEMP 9000 Advanced Thermocouple Controller

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Operating Manual. PRO 1000 Series EFS-01. Non-Programmable Thermostat

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

For Quick Set-Up go to Page 14

INSTRUCTIONS FOR HL-3 HOPPER LOADER HL-3 PPE SOUTH

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode)

B-40/B-41 Modulating Temperature Controller

Custom Products for Research. Kugelrohr Short Path Distillation

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

SC Installation, Operation & Application Guide

CG Series Digital Temperature Controller OPERATIONS MANUAL

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Mark 25 Ultrapure Water Conductivity Analyzer

INSTRUCTIONS FOR HL-9 HOPPER LOADER HL-9 PPE SOUTH

Multiple Boilers Electro TS Series Application EB-C-STG5

Application Manual Loop Water Controller

Blade Series Heat Exchanger Operation and Installation

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

SC Installation, Operation & Application Guide

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

TEMPERATURE CONTROLLER (STANDARD MODEL)

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS

RCS Residential Control Systems Inc.

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Product Manual SZ1145

CA5000 Liquid CO 2 Freezer Backup System

User Manual DME Company

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Installer Manual KNX Touchscreen Thermostat

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

CT500 Electronic Thermostat

FRUIT RIPENING CONTROLLER USER MANUAL SZ-FR INDIA

Series: MBC1-TC Mini Benchtop Temperature Controller

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

DCC-2200 / DCC-2300 CLIMATE CONTROL MODULE for Vintage Air Gen II Modules

General Purpose IO Technical Manual

INSTALLATION & OPERATION MANUAL

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

Protocol Station Remote Alarm

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

Product Manual SZ1144

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Transcription:

PLASTIC PROCESS EQUIPMENT, INC. QTC15 Temperature Controller Operation Manual PLASTIC PROCESS EQUIPMENT, INC. PPE WEST 6385 Montessouri Street, Las Vegas, Nevada 89113 702-433-6385 800-258-8877 Fax: 702-433-6388 PPE SOUTH 8303 CORPORATE PARK DRIVE, MACEDONIA (Cleveland), OHIO 44056, U.S.A. 216-367-7000 Toll Free: 800-321-0562 Fax: 216-367-7022 Order Fax: 800-223-8305 www.ppe.com e-mail: sales@ppe.com 11218 Challenger Avenue, Odessa, Florida 33556 727-834-8888 800-282-6783 Fax: 727-834-8873 Toll Free: USA, Canada & Mexico 800-362-0706

Table of Contents Controller Layout... Pg. 3 Basic Operation Procedures... Pg. 4 Parameters... Pg. 8 Parameter Description... Pg. 9 Display Codes... Pg. 11 Warranty This product is guaranteed to be free from defects in materials and workmanship for a period of two years from the date of delivery. If the unit should malfunction, it must be returned to the factory for evaluation. Upon examination, if the unit is found to be defective, at our option, it will be repaired or replaced at no cost to the customer. Warranty does not cover: card edge contacts, fuses, or triacs. Warranty is null and void when: Signs of abuse or tampering are found, incorrect fuse type is used, application of High Voltage rated over the system s required specifications, or application of High Voltage to thermocouple inputs. Liability PPE accepts no responsibility or liablity for the APPLICATION by the customer of temperature controllers. This liability is assumed by the customer. Upon inspection, if the returned product does not meet our warranty requirements, customer may be subject to a reasonable service charge. There are no warranties, expressed or implied, for temperature controllers except as stated herein. In no event shall PPE be liable for consequential, incidental, or special damages beyond our control. The buyer s sole remedy for any breach of this agreement shall not exceed the purchase price paid by the buyer to PPE. 2013 Plastic Process Equipment, Inc. All rights reserved. 2

Controller Layout Set-Point Value Display Process Value Display When decimal is lit, manual percentage power is engaged When decimal is lit, output power is on When decimal is lit, voltage is displayed ± 3% User Input Keypad When decimal is lit, K type T/C is selected When decimal is lit, amperage is displayed When decimal is lit, temp. is displayed in Celsius Blown Fuse Indicator LEDs LED indicates when fuses F1 or F2 have blown. Mode Indicator LEDs Up/down keys For adjustment of setpoint/ parameters Mode Select key Manual, Auto, Standby, and Boost Global key See Global Functions (Pg. 4) SOFT MAN AUTO STBY BST - Soft Start - Manual/Open loop - Auto/Closed loop - Standby Mode - Boost Mode Parameter key Scroll through parameters Enter/Start key Save changes or press once to exit Halt, or twice to start Amps/Volt key View Current and voltage Halt key Halts the controller (inhibits output) 3

Basic Operation Procedures The QTC15 temperature controller is ready to run from factory settings. Global Functions: GLOBAL FUNCTIONS allow individual controller parameters or modes to be sent to the system or groups of controllers. Group setup is confi gurable in parameter (P01). Up to 4 groups can be set. GLOBAL POWER ON/OFF: power on or off all controllers from any controller. Key sequence: *GLBL*, *POWER*, then *ENTER/START* Note*: If a controller is manually powered off, the function is disabled until powered back on manually. GLOBAL SETPOINT/PARAMETERS: Adjust setpoint or parameters on a single unit, and send the settings to all controllers. Key sequence: *GLBL*, *PMTR*, then *ENTER/START* GLOBAL MODE CHANGE: Change the mode on a single unit, then change mode system wide or within a group. (e.g. STANDBY or BOOST) Key sequence: *GLBL*, *MODE*, then *ENTER/START* GLOBAL CURRENT/VOLTAGE VIEW: View current and voltage on all controllers in the system. Key sequence: *GLBL*, *AMPS/VOLT*, then *ENTER/START* Notes*: If changes need to be made to individual controllers, just apply changes and press *ENTER*. Basic Operations: Turn power on by pressing the *POWER* button. SOFT START mode: The controller will start in SOFT START mode if the process value is below 212 F or 100 C. After the SOFT START duration time (parameter P20), the controller will go into AUTO mode (factory default). Note*: MODE changes cannot be made during SOFT START mode unless the lock is disabled in parameter (P21). SETPOINT CHANGE: To change the setpoint value, use the *UP* and *DOWN* keys to select the desired temperature then press *ENTER*. The minimum and maximum values for temperature and setpoint are 32-999 Fahrenheit (5-650 Celsius). 4

Mode: There are 4 running modes available: manual (open loop), automatic (closed loop), standby (idle), and boost. A solid lit LED indicates the mode the controller is in. To change mode: Press the *MODE SELECT* key until the blinking LED is over the desired mode, then press the *ENTER* key. A solid lit LED will indicate the current running mode. NOTES*: To exit the mode function with no changes, press the *MODE SELECT* then the *UP* or *DOWN* key. Siren will momentarily sound when status changes occur (e.g. when BOOST is enabled). ENTER MUST BE PRESSED AFTER ANY ADJUSTMENT (SUCH AS SETPOINT, PARAMETER, OR MODE) IS MADE TO STORE NEW INFORMATION. Standby and Boost: The controller has two confi gurations for standby and boost modes: auto or manual. Standby: AUTO-STANDBY - controller goes to the preset standby set-point temperature set in parameter (P19) MANUAL-STANDBY - controller goes to the preset % power set in parameter (P18). The controller will remain in STANDBY mode until it is manually changed to another mode, or by pressing *MODE SELECT* then *UP* or *DOWN*. Boost: AUTO-BOOST - controller goes to the preset BOOST set-point temperature set in parameter (P16). MANUAL-BOOST - controller goes to the preset % power set in parameter (P17). Controller will remain in BOOST mode until preset time has elapsed, set in parameter (P15). 5

Parameter Changes: 1. Press the *PMTR* key until the desired parameter is reached. (List of parameters is available on page 8). 2. Press the *UP* or *DOWN* key to change the options for the selected parameter. 3. When complete, press the *ENTER* key to store to memory. (Changes can be made to all parameters before pressing *ENTER*). To exit at any time, press the *ENTER* key. Error Reset: Upon detection of THF, TSH, or HIA, the controller must be powered off, then on, to clear the error once the issue has been corrected. Refer to Pg. 11 for error codes. Special Functions: Even Temperature Rise: controllers will follow the slowest rising temperature in the system. Even temperature rise is an active procedure, so fl uctuation will occur during rise. Thermocouple Slaving at Startup: At startup, in the event of a thermocouple break, the controller will slave from a controller in the same group. Live-Swap: In the event of a controller change-out, the new controller will automatically inherit the parameters and settings of the previous controller. External Alarm Output: Relay for external alarm or light. Pinout on page: 7 Remote Standby Input: Switch input for system standby. Pinout on page: 7 6

QMF Mainframe Mainframes come with communication and interface board with siren, which enables global functions, grouping, thermocouple slaving, even temperature rise, and Live Swap features. External alarm relay, and remote standby interface connector is located at the rear of the mainframe. Figures 3 a, b, and c below shows connector and external wiring circuits needed for these functions. Alarm/Relay Output & Remote Standby Input Connector Pin # Function 1 Remote Standby Input 2 3 Alarm/Relay Output 4 Figure 3a Standby Input Pin 1 Input Signal Relay or switch (customer s source) Figure 3b To mainframe connector (Figure 3a) Pin 2 Alarm/Relay Output Light or secondary alarm Match to source voltage Pin 3 External Voltage Source (Up to 240VAC 5A) To mainframe connector (Figure 3a) Figure 3c Pin 4 7

QTC15 Parameters # Parameters Defaults P01 Group - (1-4) 1 P02 TRIAC Shorted Time - (0-20) 10 P03 Even Temperature Rise - (YES or NO) YES P04 Thermocouple Slaving - (YES or NO) YES P05 Auto Power On - (YES or NO) YES P06 Control Type - Power Control Type Phase or Burst PH mode (PH or BT) P07 Over Current Limit - (1-21) Amps 16 P08 Celsius or Fahrenheit ( C or F) F P09 Thermocouple Type - (J or K) J P10 Over-temp. Alarm Limit - (8-30 Fahrenheit), (6-30 17 Celsius) P11 Under-temp. Alarm Limit - (5-30 Fahrenheit), (5 30-17 Celsius) P12 T/C Pinched - (1-250) seconds or (000 = disabled) 60 P13 Open TRIAC, Heater, or Fuse - (1-240) seconds or 30 (000 = disabled) P14 APO Enable - (YES or NO) YES P15 Boost Time Setting - (5-999) seconds 30 P16 Boost Temp. - (5-250 Fahrenheit), (5-120 75 Celsius) P17 Manual Boost Power - (5-100%) 25 P18 Manual Standby Power - (5-100%) 10 P19 Standby Temp. - (50-350 Fahrenheit), (50-175 250 Celsius) P20 Soft Start Time - (0-20) minutes 5 P21 Soft Start Lock - (YES or NO) YES P22 Audible Alarm - (YES or NO) YES P23 Siren Enable LOCAL (per module) - (YES or NO) YES P24 Siren Enable GLOBAL - (YES or NO) YES P25 Address - DISPLAY ONLY P26 Tune Stabilization - (50-100) 60 P27 Keypad Lock - (YES or NO) NO 8

Parameter Description P01) Group - Set controller for specifi ed group 1-4. P02) TRIAC Shorted Time - Time, in seconds, the controller will take to detect a TRIAC shorted error. P03) Even Temperature Rise - Controllers follow slowest rising temperature in the system. P04) Thermocouple Slaving at Startup - At startup, in the event of a thermocouple break and controllers are below 140 F, the controller will slave from a controller in the same group. P05) Auto Power On - After a power outage, controller will automatically power up upon the return of power if enabled. P06) Control Type - Power output type (PH or BT) PH half cycle phase mode BT burst cycle mode P07) Over Current Limit Detection - Maxiumum amperage controller will allow for load (Over Current Condition (HIA)). Recommended for user to adjust to heater current +10% for better protection. P08) Select degrees Celsius ( C) or Fahrenheit ( F). P09) T/C Type - Select thermocouple types J or K. P10) Over-temp. Alarm Limit - Alarm when process temp. is over setpoint value as set in parameter. P11) Under-temp. Alarm Limit - Alarm when process temp. is under setpoint value as set in parameter. P12) T/C Pinched - Time, in seconds, that the controller will take to detect a pinched or shorted thermocouple. (There is current, no rise in temperature) P13) Open TRIAC/Heater/Fuse - Time, in seconds, that the controller will take to detect an open TRIAC, open heater, open wire, or fuse. (No current and no rise in temperature) P14) APO Enable - In the event of a T/C break and the controller is at set point, the controller uses the last average output power (APO) to maintain temperature. (Automatic Bumpless Transfer). T/C must be repaired as soon as possible. P15) Boost Time setting - Time (in seconds) desired for boost mode. 9

Parameter Description (c) P16) Auto Mode Boost Temp. - Boost temperature over setpoint. (Boost temp. + setpoint) P17) Manual Mode Boost Power - Manual percentage power output during boost mode for a set time (P15). P18) Manual Mode Standby Power - Manual percentage power output during standby mode. P19) Auto Mode Standby temp. - Standby/idle setpoint value. P20) Soft-Start Time - Time duration, in minutes, that the controller is in Soft- Start. (Bake Out) P21) Soft-Start Lock - Prevents users from changing mode while in soft-start. P22) Audible Alarm Enable/Disable - controller audible alarm. P23) Local Siren Enable/Disable - siren alarm for the individual controller. P24) Global Siren Enable/Disable - siren alarm global. P25) Zone Address - Controller zone location in mainframe (Display only). P26) Tuning Stabilization - Adjustment for heaters with lagging thermocouple or low mass (quick heat dissipation heaters). If there is fl uctuation of temperature, adjust higher (recommended maximum of 75). P27) Keypad Lock - YES: Disables all keys, except for the *PMTR* key, to prevent unwanted changes. NO: All keys enabled. 10

Display Codes Display Codes: Displayed on PRT (process temperature display) Display Code Description Explaination Hi High Temperature Process temp. over setpoint value. Lo Low Temperature Process temp. under setpoint value. OTC Open Thermocouple Thermocouple is open or break. RTC Reverse Thermocouple Thermocouple wire reversed. PTC Pinched Thermocouple Thermocouple has been shorted/ pinched. THF Open TRIAC/Heater/ Fuse TRIAC, heater, or fuse (F3) is open. TSH HIA APO TRIAC/Heater Shorted Over Current Detection Average Power Output TRIAC or heater shorted. (100% power output) Load has exceeded the amperage set in parameters. Thermocouple is open and APO is currently running. GLO Global Function Global key has been pressed. 11

NOTE*: Fuse F1 and F2 - Use only ABC15 Fuse F3 - Use only GBB15 TC+ TC- ANTI-ARC HEATER OUTPUT AC INPUT HEATER OUTPUT AC INPUT GROUND ABC15 GBB15 ABC15 FUSE TYPE: F1 F3 F2