Specifications Minimum Typical Maximum Unit

Similar documents
EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

ELMTEC. Kattreppeln Königslutter / /

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EL-USB-TC Thermocouple Data Logger with USB Interface

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

EL-OEM-3 OEM Packaged Voltage Data Logger


The data logger is supplied with a lithium metal battery which typically gives two years logging life.

EasyLog Data Logger Series

EasyLog Data Logger Series

EL-OEM-3 OEM Packaged Voltage Data Logger

Data Logging Solutions

Introduction. OM-THA2

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

USER MANUAL USB Multi-Function Datalogger Model RHT35

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

DataSheet. Thermocouple Logger

User Manual. Humidity-Temperature Chart Recorder. Model RH520

DataSheet. Thermocouple Logger

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

HOBO U14 Data Logger User Manual

Sirius Technologies, Inc.

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Temperature & Humidity Monitoring For Museums & Heritage Product Guide.

Follett Performance Plus

portable gas analyser

USB DATA LOGGER FOR TEMPERATURE AND RH HM9000

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Wet Bulb Thermo-Hygrometer Datalogger

Precision Temperature Humidity Meter DTH184DL User s Manual

Microtherm Heat Stress WBGT

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

USER GUIDE Heat Index Psychrometer

CDL 210. Operating manual. CO2 Logger. Best.-Nr

USER MANUAL Digital CO Monitor Model CO30

iminiplus PDF User Guide Version 2.0

User Manual. Dryer Controller M720

D3 Wireless temperature alarm & monitoring system family. tek-troniks

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Precision Temperature Humidity Meter DTH184DL User s Manual

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Temperature/Humidity Monitor. User s Manual

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

LogTag TICT - is0 Tag

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

data logger DL200H DL200D DL200L

WS3650IT. Pro Family weather station with T/H sensor, pluviometer, anemometer & PC connection.

Monitoring Solutions

165 Supplements and Amendments to the MSR 165 User Manual

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Operation Manual Professional Remote Weather Station

portable gas analyser

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

UTRED day Logger with display

Water Tank Level Monitor

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

EASYLOG Temperature Label Series

Fridge-tag 2 L. with external sensor OPERATION MANUAL

Batt-Safe Battery String Monitoring System

Pocket CO2 Monitor & Data Logger SAN-0001

AIR MONITOR & ALARM SYSTEM Installation and Operating Guidelines Version 7.2 Series Software

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

Visit us at testo 835 Infrared and contact thermometer

Sintrol Snifter A2 EX. Manual. Version 1.2.3

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Operations Manual TS400. Test Station for G450/G460 Gas Detector

GMH 285 / GMH 285-BNC

Dryer Controller M720

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

ALTAIR 5X Multigas Detector Product Specification

Operating Instructions and Maintenance Manual

PROTÉGÉ ZM SINGLE GAS MONITOR

Tinytag Ultra Data Logger Manual

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

UTRED30-WiFi. 30 day WiFi Logger with display

KANE-ALERT-CO 2 Monitor with Temperature

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Compact Ultra Low Temperature Chamber

Oxygen & Carbon Dioxide Analyser

Transcription:

Temperature Probe Data Logger with LCD and USB Interface ORDERING INFORMATION Standard Data Logger (Data Logger, 1m Thermistor Probe, Software on CD and Battery) Replacement Battery LASREC028 LASACC001 Visit for all available Thermistor probes and extension cables FEATURES -40 to +125 C (-40 to +257 F) probe measurement range High contrast LCD with temperature display USB interface for set-up and data download User-programmable alarm thresholds Status indication via red and green LEDs Immediate, delayed and push-to-start logging Supplied with 1.0m type 2 sensor probe Probe length can be easily extended with an extension cable Supplied complete with replaceable lithium battery and Windows control software This standalone data logger measures and stores up to 32,510 temperature readings from the supplied thermistor probe which is attached via the socket at the base of the unit. The user can easily set up the logging rate and start-time, and download the stored data by plugging the data logger into a PC s USB port and running the purpose designed software under Windows XP, Vista or 7. Data can then be graphed, printed and exported to other applications. The EL-USB-TP-LCD features an LCD and push-button which allows the user to cycle through the most recent, highest and lowest stored temperature readings. The data logger is supplied complete with a long-life lithium battery, which can typically allow logging for up to 6 months. Specifications Minimum Typical Maximum Unit Supplied probe measurement range -40 (-40) +125 (+257) C ( F) Operating temperature range * -10 (+14) +40 (+104) C ( F) Resolution (internal and displayed) 0.5 (1) C ( F) Accuracy (logger error) ±0.1 (±0.2) C ( F) Logging rate every 1 s every 12 hr - 1/2AA 3.6V Lithium Battery Life 6** Month * Operating temperature applies to the data logger unit only. ** Depending on sample rate, ambient temperature and use of LCD. Specifications liable to change without prior warning Issue 3 Page 1 of 6

WINDOWS CONTROL SOFTWARE Lascar s EasyLog USB control software is supplied free of charge with each data logger. Easy to install and use, the control software runs under Windows XP, Vista or 7. The software is used to set-up the data logger as well as download, graph and export data to Excel. The software allows the following parameters to be configured: Logger name C, F Logging rate (1s, 10s, 30s, 1m, 5m, 30m, 1hr, 6hr, 12hr) High and low alarms Immediate, delayed and push-to-start logging Display off, on for 30 seconds after button press, or permanently on Data rollover (Allows unlimited logging periods by overwriting the oldest data when the memory is full) The latest version of the control software may be downloaded free of charge from THERMISTOR PROBE The probe supplied with the EL-USB-TP-LCD uses a precision thermistor to sense the temperature. Alternative lengths and probe options are available. Alternatively, the probe length may be extended by the use of a suitable extension cable. We recommend twisted pair with high quality 3.5mm jack socket/plugs for best results. The available options are listed online at PROBE MEASUREMENT ACCURACY Supplied Type 2 Thermistor Probe Part number: EL-PROBE2-1.0M-TP Thermistor Probe - sold seperately. See www.tipemp.com Specifications liable to change without prior warning Issue 3 Page 2 of 6

DISPLAY AND STATUS FUNCTIONS The EL-USB-TP-LCD features a high contrast LCD and two LEDs. The LCD shows logged temperature values using seven segment numbers, along with symbols. The LCD can also show information regarding the logging status - see LCD INDICATION below. Temperature scale symbols Three different functions are available on the display most recent logged temperature, maximum logged temperature and minimum logged temperature. The push button is used to cycle through the functions. In addition, logging and alarm status are shown using two high intensity LEDs. Reading Maximum/Minimum logged value symbol LCD INDICATION Display Logger Status Explanation Delayed Start This is shown when the logger is set to start at a specific data and time* Push to Start This is shown when the logger is setup for Push to start logging Logging This is shown when the logger is running in LCD off mode, and the button is pressed. The display clears again after three seconds Stopped If the logger has not been set to log and the button is pressed, three dashes are displayed for three seconds Probe has been disconnected The flashing message Prob, followed by a number, or letter, will be displayed if the logger is logging and the probe becomes disconnected. The number confirms the type of probe that should be connected * If the logger is set to LCD off or LCD on for 30 seconds mode, then this will only be shown after the button is pressed. Otherwise the display will remain blank. Specifications liable to change without prior warning Issue 3 Page 3 of 6

LED FLASHING MODES EL-USB-TP-LCD features two LEDs that indicate the logging, battery and alarm status: The first LED flashes red to indicate that the EL-USB-TP-LCD is in an alarm condition. It will flash when the logged temperature has exceeded a Low or High alarm level. The second LED flashes green to indicate that the EL-USB-TP-LCD is not in an alarm condition. Hold is enabled by default, which forces the logger to continue flashing the red LED after an alarm, even when the temperature has returned to normal. This feature ensures that the user is notified that an alarm level has been exceeded, without the need to download the data from the logger. Hold can be turned off via the control software. The red LED will then only flash whilst the logger is in an alarm condition. When the temperature returns to normal, the green LED will flash. Additional LED modes are explained below: Green single flash (10 seconds) The data logger is currently logging. No alarm. Green single flash (20 seconds) The data logger is currently logging. No alarm. However, the battery is low and should be replaced before logging important data. Green single flash (30 seconds) The data logger is not currently logging, but is primed to start at a later date and time (delayed start). Green double flash (20 seconds) The data logger is full and has stopped logging. No alarm. Red single flash (10 seconds) The data logger is currently logging. Low alarm. Red single flash (20 seconds) The data logger is currently logging. Low alarm. However, the battery is low and should be replaced before logging important data. Green LED Red LED Red double flash (10 seconds) The data logger is currently logging. High alarm. Red double flash (20 seconds) The data logger is currently logging. High alarm. However, the battery is low and should be replaced before logging important data. Red/Green single flash (20 seconds) The data logger is full and has stopped logging. Alarm (high, low or both). No LEDs flash The data logger is stopped, the battery is empty or there is no battery fitted. Red triple flash (10 seconds) The data logger is currently logging, but the probe has been disconnected. Specifications liable to change without prior warning Issue 3 Page 4 of 6

DIMENSIONS All dimensions in mm (inches) 134.5 (5.29) 23.9 (0.94) 21.2 (0.83) BATTERY REPLACEMENT We recommend that you replace the battery every 6 months, or prior to logging critical data. The EL-USB-TP-LCD does not lose its stored readings when the battery is discharged or when the battery is replaced; however, the data logging process will be stopped and cannot be re-started until the battery has been replaced and the logged data has been downloaded to a PC. Check with your supplier that the battery you are ordering is press fit and is not fitted with solder tags. Before replacing the battery, remove the EL-USB-TP-LCD from the PC. Note: Leaving the EL-USB-TP-LCD plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. WARNING Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Specifications liable to change without prior warning Issue 3 Page 5 of 6

THE EASYLOG USB RANGE Each EL-USB data logger features the direct-to-usb connection and easy-to-use functionality that the range is known for. The range comprises of the following data loggers: Part No Function Range Accuracy (overall error) Typ. Max. Readings Battery Battery Life* EL-USB-1 Temperature ±1ºC (±2ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-LCD Temperature with LCD ±0.5ºC (±1ºF) ±1.5ºC (±3ºF) 16,382 3.6V ½AA 1 Year EL-USB-1-PRO High Temperature -40 to +125 C (-40 to +257 F) ±0.2ºC (±0.4ºF) ±1.6ºC (±2.9ºF) 32,510 3.6V ⅔AA 3 years EL-USB-1-RCG EL-USB-2 EL-USB-2+ EL-USB-2-LCD Temperature with rechargeable battery Temperature, humidity & dew point Increased accuracy temperature, humidity & dew point Temperature, humidity & dew point with LCD -20 to +60 C (-4 to +140 F) ±1ºC (±2ºF) 32,510 Lithium Ion ±0.5ºC (±1ºF) ±3%RH ±0.3ºC (±0.6ºF) ±2.0%RH ±0.5ºC (±1ºF) ±3.0%RH ±2ºC (±4ºF) ±6.0%RH ±1.5ºC (±3ºF) ±4.0%RH ±2ºC (±4ºF) ±6.0%RH 1 month (rechargeable) 16,382 3.6V ½AA 1 year 16,382 3.6V ½AA 1 year 16,379 3.6V ½AA 1 year Increased accuracy temperature, ±0.3ºC (±0.6ºF) ±1.5ºC (±3ºF) EL-USB-2-LCD+ humidity & dew 16,379 3.6V ½AA 1 year point with LCD ±2.0%RH ±4.0%RH EL-USB-3 Voltage 0 to 30V d.c. ±1% 32,510 3.6V ½AA 1 year EL-USB-4 Current loop 4 to 20mA ±1% 32,510 3.6V ½AA 1 year EL-USB-5 Counter, Event & State N/A ±3 secs/24 hrs 32,510 3.6V ½AA 1 year EL-USB-TC Thermocouple (J, K and T- type) K-type probe included -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) -200 to +390ºC (-328 to +734ºF) (T-type) ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months EL-USB-TC-LCD EL-USB-TP-LCD Thermocouple with LCD (J, K and T-type) K-type probe included External Thermistor probe with LCD -200 to +1350ºC (-328 to +2462ºF) (K-type) -200 to +1190ºC (-328 to +2174ºF) (J-type) -200 to +390ºC (-328 to +734ºF) (T-type) *Depending on logging rate, ambient temperature, and use of alarm LED ±1ºC (±2ºF) 32,510 3.6V ½AA 6 months -40 C to +125 C (-40 to +257 F) ±0.1ºC (±0.2ºF) 32,510 3.6V ½AA 6 months EL-USB-CO Carbon monoxide 0 to 1000ppm NOT A LIFE SAVING DEVICE ±6ppm 32,510 3.6V ½AA 3 months EL-USB-CO300 Carbon monoxide 0 to 300ppm NOT A LIFE SAVING DEVICE ±4ppm 32,510 3.6V ½AA 3 months EL-USB-LITE Low cost temperature -10 C to +50 C (+14 to +122 F) ±1ºC (±2ºF) 4,080 EL-USB-RT Real-time temperature & humidity monitor -20 to +70 C (-4 to +158 F) ±1.5ºC (±3ºF) ±4.5%RH CR1620 Lithium coin cell 1 month 7 days N/A N/A Specifications liable to change without prior warning Issue 3 Page 6 of 6