Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Similar documents
Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

SAF-BCF SECOND REVISIONS WITH STATEMENTS

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Section No ]

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

26 of 128 9/23/2014 9:25 AM

Building Code Development Committee (BCDC) Minutes. San Antonio Marriott Riverwalk San Antonio, TX 05/3-4/ am Travis Room

BCAC Egress Work Group

City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control


GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Report on First Revisions with Statement June 2014 NFPA 101

Report on First Revisions with Statement June 2014 NFPA 101

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Agency for Health Care Administration

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #2

E25 (D) Automatic controls for general means of egress lighting

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

WORKING DRAFT OF COMMITTEE MEETING OUTPUT

Report on First Revisions with Statement June 2014 NFPA 101

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

CHAPTER 7 ALTERATIONS LEVEL

Public Comment No. 2-NFPA [ Section No ]

Agency for Health Care Administration

Public Comment No. 7-NFPA 30A-2013 [ Section No ]

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Agency for Health Care Administration

AGENDA. NFPA Correlating Committee on Safety to Life (SAF-AAC) NFPA 101 Second Draft Meeting. November 17, NFPA Headquarters, Quincy, MA

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM


Public Comment No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment. Submitter Information Verification

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

AHC Meeting #7 July 12-13, Occupancy WG Report

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

2012 B.C. Building Code Compliance Review (Division B Part 3)

Page 1 of 5 1/29/2016 4:08 PM. First Correlating Revision No. 3-NFPA [ Section No ] Submitter Information Verification

For additional information regarding R-3.1 residential care facilities please contact (951)

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Life Safety - Means of Egress/Exits NFPA 101

NFPA 80 Overview January 21, 2016

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline


ICC code change proposals are being reviewed, evaluated, prioritized, and desired results determined by the BHMA Task Group working on the proposals.

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

rpsa FIRE PROTECTION ENGINEERS

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

MEMORANDUM. Technical Committee on Notification Appliances for Fire Alarm and Signaling Systems

INITIAL FIRE SAFETY ASSESSMENT

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO

Residential Based Care Facility Guidelines

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

2000 to 2012 Hospital K-tag crosswalk matrix for hospitals 2000 Tag #

MEMORANDUM. Technical Committee on Alternative Approaches to Life Safety. NFPA 101A First Draft Technical Committee FINAL Ballot Results (A2018)

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

About the Instructor & Presenter:

INITIAL FIRE SAFETY ASSESSMENT

Committee Input No. 1-NFPA [ Chapter 2 ]

NFPA 101 and NFPA 99, 2012 Editions Code Update. where art meets engineering

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

Short-Term & Accessory Short-Term Rental Safety Certification

FIRE & LIFE SAFTEY STANDARD

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Agency for Health Care Administration

1 of 4 10/26/2015 1:58 PM. Committee Input No NFPA [ Section No ]

First Revision No. 82-NFPA [ Section No ] Submitter Information Verification. Committee Statement. 2 of /21/2013 1:03 PM

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

NFPA Changes

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST

Safety Tips for the Office

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

INITIAL FIRE SAFETY ASSESSMENT

Transcription:

Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. (SAF-MEA) Submittal Date: Tue Jun 21 11:39:31 EDT 2016 Committee Statement: NOTE: This Public Comment appreared as CC Note No. 1 in the First Draft Report. The Correlating Committee directs the TC on Means of Egress (MEA) to consider the Affirmative with Comment ballots of Pappas and Tierney to revise the definition by combining the two sentences to read as follows: Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing. (SAF-MEA) This action will be considered as a public comment. Response Message: Public Comment No. 5-NFPA 101-2016 [Section No. 3.3.56]

Second Revision No. 5007-NFPA 101-2016 [ Section No. 3.3.228 ] 3.3.228* Public Way. A street, alley, or other similar parcel of land essentially open to the outside air deeded, dedicated, or otherwise permanently appropriated to the public for public use and having a clear width and height of not less than 10 ft (3050 mm). (SAF-MEA) Supplemental Information File Name SR5007_Attachment.docx Description New A.3.3.228 Submittal Date: Tue Jun 21 13:57:18 EDT 2016 : SR adds new A.3.3.228 to clarify the intent of the public way. See CI-5017 in the First Draft Report. Response Message:

A.3.3.228 Public Way. The intent of the definition of public way is to establish an end-point at which the means of egress terminates, not under the jurisdiction of the Code and to which the Code s requirements do not apply. As such, the Code intends a situation where occupants egressing from a building ultimately reach a point where they can move away from the building unimpeded and no longer need the protections of the Code.

Second Revision No. 5011-NFPA 101-2016 [ Section No. 7.1.5.1 ] 7.1.5.1 Means of egress shall be designed and maintained to provide headroom in accordance with other sections of this Code, and such headroom shall be not less than 7 ft 6 in. (2285 mm), with projections. Projections from the ceiling shall provide headroom of not less than 6 ft 8 in. (2030 mm), with a tolerance of 3 4 in. ( 19 mm), above the finished floor, unless otherwise specified by any of the following: (1) In existing buildings, the ceiling height shall be not less than 7 ft (2135 mm) from the floor, with projections from the ceiling not less than 6 ft 8 in. (2030 mm) nominal above the floor. (2) Headroom in industrial equipment access areas as provided in 40.2.5.3 shall be permitted. Submittal Date: Tue Jun 21 15:52:36 EDT 2016 : Revision intended for consistency with NFPA 5000. Response Message:

Second Revision No. 5002-NFPA 101-2016 [ Section No. 7.1.6.5 ] 7.1.6.5* Grab Bars for Bathtubs, Bathtub-Shower Combinations, and Showers. 7.1.6.5.1 General. 7.1.6.5.1.1 Where required by Chapters 11 through 43, new bathtubs, bathtub-shower combinations, or and showers, for use by occupants, shall be provided with grab bars complying with 7.1.6.5.2 through 7.1.6.5.5, except as unless otherwise permitted for showers inby 7.1.6.5.1.2, with all dimensions referring to the centerline of the grab bar unless otherwise stipulated. 7.1.6.5.1.2* Where a dedicated shower does not expose users to changes in elevation exceeding 0.5 in. (13 mm), as described in 7.1.6.2, and it provides slip resistance for all surfaces when wet, as a foreseeable condition described in 7.1.6.4, the requirements of 7.1.6.5.2 through 7.1.6.5.5 shall apply only if grab bars are installed. Grab bars shall not be required in showers where the transition from the room floor to the shower floor does not exceed 0.5 in. (13 mm) in height and all shower surfaces are slip resistant when wet. 7.1.6.5.1.3 Where provided, grab bars shall comply with 7.1.6.5.2 through 7.1.6.5.4. 7.1.6.5.1.4 All dimensions shall be measured to the centerline of the grab bar unless otherwise stated. 7.1.6.5.2 Vertical Grab Bar or Pole. A vertical grab bar shall be provided either installed on the control end wall or the end wall opposite the control end wall of the bathtub, bathtub-shower combination, or shower as specified in accordance with 7.1.6.5.2.1, or shall be provided as a free-standing an external vertical pole as specified in accordance with 7.1.6.5.2.2 7.1.6.5.2.2. 7.1.6.5.2.1* Vertical Grab Bar on Control. End Wall Vertical Grab Bars. A End wall vertical grab bar, bars shall comply with all of the following: (1) Vertical grab bars shall have a minimum length of not less than 36 in. (914 mm). (2) Vertical grab bars shall be located between 24 in. (610 mm), and i ts lower end between 36 and 39 27 in. (915 and 990 686 mm) above the finished floor, measured to the lower end. (3) Vertical grab bars shall be installed on the entry/egress open side of the control end wall of the bathtub, bathtub-shower combination, or shower unit used for entry and egress. (4) The Vertical grab bars shall be located at least 6 between 9 in. (150 228 mm) and 12 in. (305 mm) from the open entry and egress side of the bathtub, bathtub-shower combination, or shower, measured horizontally, from any the exterior plane of the bathtub, bathtub- shower curtain rod fixing point on the wall combination, or shower. (A) A vertical grab bar, with a minimum length of 24 in. (610 mm), and its lower end between 36 and 39 in. (915 and 990 mm) above the finished floor, shall be installed on the entry/egress side of the control end wall of the bathtub, bathtub-shower combination, or shower unit. (B) The grab bar shall be located at least 6 in. (150 mm), measured horizontally, from any shower curtain rod fixing point on the wall. 7.1.6.5.2.2* Vertical Grab Bar as Free Standing, External Vertical Poles. A vertical Vertical, pole-type grab bars fixed to the floor and either the room ceiling or an adjacent wall shall comply with all of the following: (1) Poles shall be installed outside of the bathtub, bathtub-shower combination, or shower unit. (2) Poles shall be located within 6 in. (150 mm), measured horizontally, of the outside of the outer edge of the bathtub, bathtubshower combination, or shower. and (3) Poles shall be located within 30 in. (760 mm), measured horizontally, of the vertical plane of the control end wall if there is such a wall. 7.1.6.5.3 Back Wall Grab Bar. For bathtubs and bathtub-shower combinations bounded on three sides by walls, a grab bar shall be provided on the back wall either as a diagonal grab bar as specified in accordance with 7.1.6.5.3.1 or as a horizontal grab bar as specified in accordance with 7.1.6.5.3.2shall be provided on the back wall. 7.1.6.5.3.1* Back Wall Diagonal Grab Bars on Back Wall.

A diagonal Diagonal grab bars shall be installed on the back wall comply with all of the following: (1) Diagonal grab bars shall have a minimum length of not less than 24 in. (600 mm) with its. (2) Diagonal grab bars shall be located so the higher end placed closer is closest to the control end wall and. (3) Diagonal grab bars shall be located a maximum of 12 in. (305 mm) from the control end wall, with a height of 25 to. (4) Diagonal grab bars shall be located 25 in. (635 mm) minimum and 27 in. (635 to 685 mm) maximum above the rim of the bathtub. (5) The Diagonal grab bars shall be located so the lower end of the diagonal grab bar shall be located at a height of is 8 to in. (203 mm) minimum and 10 in. (205 to 255 254 mm) maximum above the rim of the bathtub and. (6) Diagonal grab bars shall be located 28 to in. (711 mm) minimum and 30 in. (710 to 760 mm) maximum from the control end wall. (A) A diagonal grab bar shall be installed on the back wall with a minimum length of 24 in. (600 mm) with its higher end placed closer to the control end wall and located a maximum of 12 in. (305 mm) from the control end wall, with a height of 25 to 27 in. (635 to 685 mm) above rim of the bathtub. (B) The lower end of the diagonal grab bar shall be located at a height of 8 to 10 in. (205 to 255 mm) above the rim of the bathtub and 28 to 30 in. (710 to 760 mm) from the control end wall. 7.1.6.5.3.2 Back Wall Horizontal Grab Bar on Back Wall. A horizontal Horizontal grab bars shall comply with all of the following: (1) Horizontal grab bars shall be installed on the back wall at a height of located 8 to in. (205 mm) minimum and 10 in. (205 to 255 mm) maximum above the bathtub rim with. (2) Horizontal grab bars shall be located so one end located a maximum of is 12 in. (305 mm) maximum from the control end wall and the other end is located a maximum of 24 in. (610 mm) maximum from the opposite, or head, end of the bathtub. 7.1.6.5.4* Grab Bar Details. 7.1.6.5.4.1 Grab bars shall be circular in cross section with a minimum diameter of 1 1 4 in. (32 mm) and a maximum diameter of 2 in. (51 mm). 7.1.6.5.4.2 If Where attached to a wall, the grab bars shall provide a minimum clearance for hand grasp of 1 1 2 in. (38 mm) for hand grasp minimum. 7.1.6.5.4.3 The size and clearance dimensions required by 7.1.6.5.4.1 and 7.1.6.5.4.2 shall be provided, as a minimum, within the height requirements range and the minimum length requirements range of the other provisions of 7.1.6.5 Grab bars shall be designed and constructed to the structural loading conditions in accordance with the building code. 7.1.6.5.5 Grab Bar Structural Loading. Grab bars shall be designed and constructed to the structural loading conditions in accordance with the building code. Submittal Date: Mon Jun 20 10:51:58 EDT 2016 Committee Statement: Response Message: NFPA's Disability Access Review and Advisory Committee (DARAC) supports the concept of the first revision but has voted unanimously to propose re-writing the section so that it is workable, clear, and concise. The SR incorporates PC 146 and 170 and editorial revisions for consistency with the Code. Public Comment No. 146-NFPA 101-2016 [Section No. 7.1.6.5] Public Comment No. 170-NFPA 101-2016 [Section No. 7.1.6.5]

Second Revision No. 5001-NFPA 101-2016 [ Section No. 7.2.1.5.10.7 ] 7.2.1.5.10.7 Two releasing operations shall be permitted for educational occupancy classroom doors secured against unwanted entry in accordance with the provisions of Chapter 15. Submittal Date: Mon Jun 20 10:04:56 EDT 2016 Committee Statement: Response Message: It is the position of the TC on Means of Egress that increasing the number of latch/lock releasing operations is dangerous and could create a hazard to occupants. Technology exists that will meet the current code requirement for not more than one latch/lock releasing operation. The need for multiple operations is contrary to decades of experience resulting in fatalities in schools and other buildings. Single-action egress is an important aspect of life safety for all emergencies. Public Comment No. 42-NFPA 101-2016 [New Section after 7.2.1.5.3]

Second Revision No. 5003-NFPA 101-2016 [ Section No. 7.2.1.6.1 ] 7.2.1.6.1 Delayed-Egress Electrically Electrical Locking Systems. 7.2.1.6.1.1 Approved, delayed-egress electrically electrical locking systems shall be permitted to be installed on door assemblies serving lowand ordinary-hazard contents in buildings protected throughout by an approved, supervised automatic fire detection system in accordance with Section 9.6 or an approved, supervised automatic sprinkler system in accordance with Section 9.7, and where permitted in Chapters 11 through 43, provided that all of the following criteria are met: (1) The delay of the delayed-egress electrically electrical locking system shall deactivate allowing unobstructed egress upon actuation of one of the following: (a) Approved, supervised automatic sprinkler system in accordance with Section 9.7 (b) Not more than one heat detector of an approved, supervised automatic fire detection system in accordance with Section 9.6 (c) Not more than two smoke detectors of an approved, supervised automatic fire detection system in accordance with Section 9.6 (2) The delay of the delayed-egress electrically electrical locking system shall deactivate allowing unobstructed egress upon loss of power controlling the lock or locking mechanism. (3)* An irreversible process shall release the electrical lock in the direction of egress within 15 seconds, or 30 seconds where approved by the authority having jurisdiction, upon application of a force to the release device required in 7.2.1.5.10 under all of the following conditions: (a) The force shall not be required to exceed 15 lbf (67 N). (b) The force shall not be required to be continuously applied for more than 3 seconds. (c) The initiation of the release process shall activate an audible signal in the vicinity of the door opening. (d) Once the electrical lock has been released by the application of force to the releasing device, rearming the delay electronics shall be by manual means only. (4)* A readily visible, durable sign that conforms to the visual characters requirements of ICC/ANSI A117.1, Accessible and Usable Buildings and Facilities, shall be located on the door leaf adjacent to the release device in the direction of egress, and shall read as follows: (a) (b) PUSH UNTIL ALARM SOUNDS, DOOR CAN BE OPENED IN 15 SECONDS, for doors that swing in the direction of egress travel PULL UNTIL ALARM SOUNDS, DOOR CAN BE OPENED IN 15 SECONDS, for doors that swing against the direction of egress travel (5) The egress side of doors equipped with delayed-egress electrically electrical locking system shall be provided with emergency lighting in accordance with Section 7.9. (6) Hardware for new installations shall be listed in accordance with ANSI/UL 294, Standard for Access Control System Units. 7.2.1.6.1.2 The provisions of 7.2.1.6.2 for sensor-release of electrical locking systems shall not apply to door assemblies with delayed-egress electrically electrical locking systems. Submittal Date: Mon Jun 20 11:11:25 EDT 2016 Committee Statement: NOTE: This Public Comment appeared as CC Note No. 7 in the First Draft Report. The Correlating Committee directs the TC on Means of Egress (MEA) to consider the Affirmative with Comment ballot of Tierney to revise the term delayed egress electrically locking systems to delayed egress electrical locking systems and make consistent use of the term. This action will be considered as a public comment.

Response Message: Public Comment No. 8-NFPA 101-2016 [Section No. 7.2.1.6.1]

Second Revision No. 5009-NFPA 101-2016 [ Section No. 7.2.1.6.3 ] 7.2.1.6.3 Elevator Lobby Exit Access Door Assemblies Locking. Where permitted in Chapters 11 through 43, door assemblies separating the elevator lobby from the exit access required by 7.4.1.6.1 shall be permitted to be electrically locked, provided that all the following criteria are met: (1) The electrical locking hardware is listed in accordance with ANSI/UL 294, Standard for Access Control System Units. (2) The building is protected throughout by a fire alarm system in accordance with Section 9.6. (3) The building is protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7. (4) Waterflow in the sprinkler system required by 7.2.1.6.3(3) is arranged to initiate the building fire alarm system. (5) The elevator lobby is protected by an approved, supervised smoke detection system in accordance with Section 9.6. (6) Detection of smoke by the detection system required by 7.2.1.6.3(5) is arranged to initiate the building fire alarm system and notify building occupants. (7) Initiation of the building fire alarm system by other than manual fire alarm boxes unlocks the electrical locks on the elevator lobby door assembly. (8) Loss of power to the elevator lobby electrical lock system unlocks the electrical locks on the elevator lobby door assemblies. (9) Once unlocked, the elevator lobby door assemblies remain electrically unlocked until the building fire alarm system has been manually reset. (10) Where the elevator lobby door assemblies remain mechanically latched after being electrically unlocked, latch-releasing hardware in accordance with 7.2.1.5.10 is affixed to the door leaves. (11) A two-way communication system is provided for communication between the elevator lobby and a central control point that is constantly staffed. (12) The central control point staff required by 7.2.1.6.3 is capable, trained, and authorized to provide emergency assistance. (13) The provisions of 7.2.1.6.1 for delayed-egress electrically electrical locking systems are not applied to the elevator lobby door assemblies. (14) * The provisions of 7.2.1.6.2 for sensor-release of electrical locking systems are not applied to the elevator lobby door assemblies. Submittal Date: Tue Jun 21 15:36:35 EDT 2016 : The revision responds to CC Note 7. Response Message:

0 Second Revision No. 5004-NFPA 101-2016 [ Section No. 7.2.1.15.6 ] 7.2.1.15.6 As a minimum, the following items shall be verified: (1) Floor space on both sides of the openings is clear of obstructions, and door leaves open fully and close freely. (2) Forces required to set door leaves in motion and move to the fully open position do not exceed the requirements in 7.2.1.4.5. (3) Latching and locking devices comply with 7.2.1.5. (4) Releasing hardware devices are installed in accordance with 7.2.1.5.10.1. (5) Door leaves of paired openings are installed in accordance with 7.2.1.5.11. (6) Door closers are adjusted properly to control the closing speed of door leaves in accordance with accessibility requirements. (7) Projection of door leaves into the path of egress does not exceed the encroachment permitted by 7.2.1.4.3. (8) Powered door openings operate in accordance with 7.2.1.9. (9) Signage required by 7.2.1.4.1(3), 7.2.1.5.5, 7.2.1.6, and 7.2.1.9 is intact and legible. (10) Door openings with special locking arrangements function in accordance with 7.2.1.6. (11) Security devices that impede egress are not installed on openings, as required by 7.2.1.5.12. (12) Where required by 7.2.2.5.5.7, door hardware marking is present and intact. (13) Emergency lighting on sensor-release of electrical locking systems and doors equipped with delayed-egress electrically electrical locking systems is present and functioning in accordance with Section 7.9. Submittal Date: Mon Jun 20 11:23:14 EDT 2016 Committee Statement: Response Message: The committee believes that verifying the presence of emergency lighting is appropriate, but functional testing of emergency lighting is covered in Section 7.9 and therefore does not need to be part of the door inspection procedures. The requirement for verifying the presence of emergency lighting is consistent with the other provisions in 7.2.1.15.6. The revision also responds to CC Note 7, which replaces 'electrically' with 'electrical'. Public Comment No. 61-NFPA 101-2016 [Section No. 7.2.1.15.6]

1 Second Revision No. 5005-NFPA 101-2016 [ Section No. 7.2.3.9.4 ] 7.2.3.9.4 The requirement of 7.2.3.9.2 shall not apply to any of the following: (1) Control wiring and power wiring utilizing a 2-hour-rated cable or cable system (2) Where Control wiring and power wiring encased with not less than 2 in. (5 51 mm) of concrete (3) Control wiring and power wiring protected by a listed electrical circuit protective system with not less than a 2-hour fire-resistive rating Submittal Date: Mon Jun 20 11:34:44 EDT 2016 Committee Statement: NOTE: This Public Comment appeared as CC No. No. 9 in the First Draft Report. The Correlating Committee directs the TC on Means of Egress (MEA) to correct the metric value in 7.2.3.9.4(2) from (5 mm) to (51 mm). This action will be considered as a public comment. SR also clarifies intent of Item (2). Response Message: Public Comment No. 9-NFPA 101-2016 [Section No. 7.2.3.9.4]

2 Second Revision No. 5008-NFPA 101-2016 [ Section No. 7.3.1.1.1 ] 7.3.1.1.1 The total capacity of the means of egress for any story, balcony, tier, or other occupied space shall be sufficient for the occupant load thereof. unless one of the following conditions exists: (1) The authority having jurisdiction shall be permitted to establish the occupant load as the number of persons for which existing means of egress is adequate, provided that measures are established to prevent occupancy by a greater number of persons. (2) The egress capacity shall have been previously approved as being adequate. Submittal Date: Tue Jun 21 14:32:33 EDT 2016 Committee Statement: Response Message: This language is currently in Ch. 43 and is applicable only when renovation, modification, or reconstruction work occurs. There doesn't seem to be any reason to limit its application to when rehabilitation work occurs. See CI-5018 in the First Draft Report.

3 Second Revision No. 5010-NFPA 101-2016 [ Section No. A.7.2.1.6 ] A.7.2.1.6 None of the special locking arrangements addressed in 7.2.1.6 are intended to allow credentialed egress, request to exit, or similar provisions, where an occupant cannot leave the building without swiping a card through a reader. Where such an arrangement is desired to keep track of occupants, the swiping of cards needs to be procedural but not necessary for releasing the door lock or latch. Free egress needs to be available at all times. Another option to free egress is the use of a delayed-egress electrically electrical locking system. Submittal Date: Tue Jun 21 15:40:13 EDT 2016 : The revision responds to CC Note 7. Response Message: