Sealed Electric Wall & Floor Mounted Towel Warmers. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual.

Similar documents
mr.steam Lexington Collection Feel Good Inc. REFER TO INSTALLATION, MAINTENANCE MANUAL PROVIDED WITH PRODUCT FOR COMPLETE INSTRUCTIONS

Model. Serial No. Installation, Operation and Maintenance Manual. Lexington Collection ELECTRIC TOWEL WARMERS. mr.steam. Feel Good Inc.

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

User Manual / Care Instructions

Hardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers

Installation and Operation Instructions Luxury Towel Warmer Free Standing or Wall Mounted

Installation, Operation and Maintenance Manual. Broadway Collection Electric Towel Warmers Models: W216, W219, W228, W236, W248

WHISPA III 5000 WM & 9000 WM. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual. Part Number: Issue 1

PENSOTTI TOWEL BAR WARMERS

MYSON. Towel Warmers. heatingthroughinnovation.

Installation & Operation Manual for WarmlyYours Towel Warmers

Hydronic Series Towel Warmers Installation & Operating Guide

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Electric & Hydronic Models Installation & Operating Instructions. mr.steam towelwarmers. Model. Serial # PUR Rev. 9.0/06

Installation & Operation Manual for WarmlyYours Towel Warmers

Installation & Operation Manual for WarmlyYours Riviera Towel Warmers

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

WHISPA III 5000, 7000 & Installation, Operating, Maintenance and After Sales Manual. Tested to UL & CSA Standards. Part Number: Issue 1

SLIM-LINE RC. Installation, Operating, Maintenance and After Sales Manual. Please leave this manual with the end user. Part Number: Issue 3

TOWEL WARMERS INSTALLATION INSTRUCTIONS Towel Warmer Installation Instructions

Wall Mount Electric Fireplace

Contact Details. Please note that some of the contact details on this PDF document may not be current.

MILLI PURE VERTICAL TRIPLE HEATED TOWEL RAIL 900X38 - CHROME

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Installation. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models)

HI-LINE RC & HI-LINE RC Heater/Cooler Models: 7-4, 10-6, 15-10, Installation, Operating, Maintenance and After Sales Manual.

ELECTRIC FLAT PANEL FIREPLACE HEATER

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

WAILEA OWNER S MANUAL

OWNER S MANUAL MODEL BW4B SLICER WARMER

READ AND SAVE THESE INSTRUCTIONS

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

Owner s Guide and Installation Manual

Viking Installation Guide

Installation Instructions 30 French Door Built-in Wall Ovens

Electric OmnipanelII Towel Radiator

Installation Instructions

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Operating and installation instructions

Wall Mounted Electric Heater Quartz

Installation Guide. 5 Series Professional Built-In Electric Single and Double Ovens 7 Series Professional Built-in Electric Double French Door Oven

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

Owner s Guide and Installation Manual

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

Installation GUIDE 6 SERIES. Built-in Electric Single and Double Wall Ovens MVSOE630 / CMVSOE630 MVDOE630 / CMVDOE630

Manual for Ceiling Patio Heater

Viking Installation Guide

DESIGN CLASS FUNCTION

INSTALLATION AND OPERATING INSTRUCTIONS Page 1

ANTUS COLLECTION ADDITIONAL COMPONENTS. Instructions for Use & Installation. SKU Width HEIGHT Power Amps BTU.

ELECTRIC FIREPLACE WITH MANTEL MODEL WS-Q-03 OWNERS MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

Viking Installation Guide

Instruction Manual. Black Radiant Heater HIL Please read these instructions carefully before using your new heater

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

SYSTEM BASIC WHIRLPOOLS

Diamond Whirlpool/Air pool INSTALLATION & OPERATION INSTRUCTION

Viking Installation Guide

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL IMPORTANT SAFETY INSTRUCTIONS

Installation Guide. Pedicure Spa D K-163, K-1006, K-1011, K-1012

Viking Installation Guide

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Installation. Guide. 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730

Installation. Built-in Full Height Wine Cellar VCWB301

Installation and Operation Manual For Hunter Ceiling Fans

NO VENTING REQUIRED 120V AC;

Viking Installation Guide

INSTRUCTIONS FOR CARBON INFRARED HEATER

Operating instructions

DESIGN CLASS FUNCTION

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

Serene Classic Rails

tungsten Smart-heat electric heater

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

TPI Corporation P.O. BOX 4973 JOHNSON CITY, TN

Radiant Heater. Instruction Manual QH-200 N13275

CERAMIC TOWER FAN HEATER PL2000

Installation Instructions & Operating Manual IMPORTANT

CEILING FAN OWNER'S MANUAL

Installation Instructions

2 KW OIL FILLED RADIATOR

Model: Ecostrad Thermostrip with Remote

Installation Instructions. Warming Drawer

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN

ASSEMBLY AND DRESSING INSTRUCTIONS

Instruction Manual. Oil Heaters. Model: OIL5, OIL7, OIL9 & OIL11T READ AND SAVE THESE INSTRUCTIONS

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Installation GUIDE 5 SERIES. Warming Drawer VWD527 VWD530

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

QUADRO COLLECTION COMPONENTS. Instructions for Use & Installation Plastic Anchor Threaded Wall Support Anchor Screw Threaded Long Tube

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Installation Instructions

Transcription:

Installation, Operating, Maintenance and After Sales Manual. Sealed Electric Wall & Floor Mounted Towel Warmers heatingthroughinnovation. Part Number: TPLEA0036 Issue 3 Tested to UL & CSA Standards

Contents 1.0 General Information 03 2.0 Location 03 3.0 Preparation 03 4.0 Fixing 03 5.0 Electrical Connection 05 6.0 Technical Data 06 7.0 Operating Instructions 11 8.0 Maintenance 11 As you follow these instructions, you will notice warning and cautions symbols. The symbols call out information important for the safe and efficient installation and operation of your towel warmer. WARNING CAUTION HOT States a hazard: serious injury or death may occur if precautions are not followed. Signals a situation where minor injury or product damage may occur if instructions are not followed. Signals that the towel warmer is hot. If contact occurs it can cause burns. IMPORTANT Highlights information that is especially relevant to a problem free installation.

Sealed Electric Wall & Floor Mounted Towel Warmers 03 1.0 General Information READ THIS INSTRUCTION MANUAL THOROUGHLY BEFORE BEGINNING INSTALLATION. 1.0 WARNING This is an electrical heating appliance, intended only for indoor use in homes, hotels and spas. For your safety please use your towel warmer with the following precautions: According to the National Electrical Code all electrical work must be carried out by authorized /licensed professionals. For your safety, please ensure you adhere to these regulations. 2.0 DO NOT place the towel warmer unit inside a shower, sauna or steam room enclosure or any location where the towel warmer is in direct contact with water. The MYSON towel warmer should not be located on a wall over a bath tub. Do not stand, hang or sit on the towel warmer. HOT The towel warmer will be hot. Please exercise caution if the towel warmer is accessible to children or the elderly. Please ensure that children are supervised at all times in the vicinity of the towel warmer and warn them that it is a hot surface that can cause burns. 3.0 2.0 Location 3.0 Preparation WARNING The towel warmer must be located in accordance with any prevailing codes and relevant electrical wiring rules and regulations, in particular regulations that cover the use of products and accessories in damp situations such as bathrooms, showers, laundries and other areas with fixed water containers. The top of this product must be at least 2 below any overhanging surface. 4.0 Fixing Before proceeding with installation, carefully unpack the carton and check against the checklist below: Towel Warmer Installation and Operating Instructions Warranty Information Sheet It is the responsibility of the installer to inspect for any damage when the carton is opened. Shipping damage should be reported immediately to your place of purchase. 4.0 IMPORTANT This product must be mounted upright and fixed securely with the electrical connection point in the bottom right hand corner position as shown in the diagrams in Section 6. No other position is safe or acceptable. This product must be securely mounted to the wall/floor. When possible it should be attached to adequate blocking or framing. For mounting directly to sheetrock, where blocking or framing is not available, appropriate wall anchors must be used. Mounting for ERR, ECM, EMR, ECMH, EINT: Place the product in the desired location and mark the position of the fixing brackets. Drill holes such that the brackets line up with the location of the fixing lugs. Loosen the grub screw and the large screw on the bracket with the key provided, and remove the central cylinder. Fix the brackets firmly to the wall. Screw the central cylinders firmly into the fixing bosses on the back of the towel warmer, and then slide smoothly into the wall brackets. DO NOT FORCE - adjust wall bracket position to ensure smooth fitting. Tighten grub screw and large screw. Mounting for: EB24, EB27, EB29, EB30, EB31, EB34, EB35, EB36, EB49, EVR1, EO100, EO140, (Flange mounted products). Place the product in the desired location and mark the position of the fixing holes. Drill holes according to choice of fixing (eg plastic anchors, wall blocking). Fix the product firmly to the wall / floor. Use all fixing holes to secure the product. Note: The EINT model insert studs have hooks that interface with the welded brackets on the towel warmer

04 Sealed Electric Wall & Floor Mounted Towel Warmers 4.0 Fixing (cont) Mounting for ECOS, ECOC: Secure inner bracket to rail in the positions shown in Technical Data (Section 6) using clamp and screw. Place the product in the desired location and mark the position of the inner fixing brackets. Drill holes such that the inner brackets line up with the location of the outer brackets. Fix inner brackets firmly to wall. Slide outer brackets onto inner brackets and lock with grub screw. DO NOT FORCE - adjust wall bracket position to ensure smooth fitting if necessary. Mounting for EGAV: (Discontinued) Decide on the location for the towel warmer and then follow the fitting instructions below. Mounting for ECAV: (Discontinued) Decide on the location for the towel warmer and mark the position of the wall brackets. Drill holes for the wall bracket and fix securely. Slide middle bracket into the towel warmer bracket and lock in place using the fixing screw. Slide towel warmer onto wall bracket. DO NOT FORCE - adjust wall bracket position to ensure smooth fitting. Tighten the grub screws.

Sealed Electric Wall & Floor Mounted Towel Warmers 05 4.0 Fixing (cont) Mounting for ES40: Place the product in the desired location and mark the position of the fixing brackets. Drill holes and fix wall bracket securely. Slide the towel warmer onto the wall brackets. DO NOT FORCE - adjust wall bracket position to ensure smooth fitting. Tighten the locking screw. IMPORTANT For the correct installation of radiators it is essential that the fixing of the towel warmer is carried out in such a way that it is suitable for intended use AND predictable misuse. A number of elements need to be taken into consideration including the fixing method used to secure the towel warmer to the wall, the type and condition of the wall itself, and any additional potential forces or weights that may happen to be applied to the towel warmer, prior to finalising installation. 4.0 5.0 Electrical Connection CAUTION WARNING HOT Electrical connection of this product must be carried out by a licensed electrician, in accordance with LOCAL OR NATIONAL ELECTRICAL CODES. If tube is to be rotated, the grub screws must be completely loosened before turning. This product may be hot to touch. It is the responsibility of the installer to ensure this caution is brought to the attention of all users. Provision for disconnection from the electrical supply must be incorporated in the fixed wiring in accordance with the wiring rules. To provide continued protection against risk of electric shock, connect to properly grounded outlets only. It is recommended this towel warmer is fitted to a GFI breaker. A dedicated circuit is required. Neutral (Supply) w Switch Prior to fixing and electrical connection the 120V AC wiring must be roughed in to a standard size outlet box in the wall. The wire box should be positioned at the lower right corner of the product. Check the product specifications for the exact location of the box in the wall. At this point, the mounting hardware should be located and fixed to the wall. Remove the ferrule at the end of the tube. Put the wires through the wall plate and fix the wall plate to the tube by tightening the large nut supplied with the kit. Replace the ferrule on the end of the tube and tighten ensuring that the strain relief plate is firmly located with the dimples aligned. Connect the wires from the product to the wires in the wall box using appropriate wire nut connectors. Connectors should be tight so as to prevent arcing or heat build up from poor connection. Slip the product onto its mounting hardware on the wall and tighten. Align the wall plate with the box and mount with screws. The switch tube on EB30 can be mounted vertically if desired. Loosen the two set screws and rotate the tube to the vertical position. Re-tighten set screws. Switch on the electrical supply. Turn on the product and allow 30+ minutes to warm up. 5.0 Line (Supply) bk Switch Holder Wall Plate Ground g bk w Locking Nut w = White bk = Black g = Green Electric Element Strain Relief Washer Strain Relief Bush

06 Sealed Electric Wall & Floor Mounted Towel Warmers 6.0 Technical Data Dimension Drawings EB24 EB27 EB29 G EB30 EB31 EB34 Model Power* (Watts) Dimensions (ins) A B C D E F G H EB24 100 37 5 / 8 27 5 / 16 30 7 / 16 24 3 3 / 8 14 3 / 4 5 1 / 2 N/A 1 1 / 4 55 EB27 200 37 5 / 8 27 5 / 16 30 7 / 16 24 3 3 / 8 12 3 / 16 5 1 / 2 N/A 1 1 / 4 60 EB29 200 40 15 / 16 27 5 / 16 30 7 / 16 24 3 3 / 8 N/A 5 1 / 2 N/A 1 1 / 4 65 EB30 200 40 3 / 8 27 5 / 16 30 7 / 16 24 3 3 / 8 4 1 / 2 11 1 / 4 N/A 1 1 / 4 80 EB31 200 27 5 / 16 27 5 / 16 30 7 / 16 24 3 3 / 8 N/A 5 1 / 2 N/A 1 1 / 4 55 EB34 100 27 5 / 16 27 5 / 16 30 7 / 16 24 3 3 / 8 N/A 5 1 / 2 N/A 1 1 / 4 40 *Represents draw at steady state. Power could be higher during warm up. Tube diameter (ins) Approx shipping weight (lbs)

Sealed Electric Wall & Floor Mounted Towel Warmers 07 6.0 Technical Data (cont) EB35 EB36 EB49 6.0 ES40/1 EVR1 ERR Model Dimensions (ins) Power* (Watts) A B C D E F G H Tube diameter (ins) Approx shipping weight (lbs) EB35 150 51 5 / 16 21 1 / 4 24 7 / 16 18 3 3 / 8 N/A 5 1 / 2 N/A 1 1 / 4 150 EB36 280 51 5 / 16 21 1 / 4 24 7 / 16 18 3 3 / 8 N/A 5 1 / 2 N/A 1 1 / 4 150 EB49 285 73 1 / 2 27 5 / 16 30 7 / 16 24 3 3 / 8 12 3 / 16 5 1 / 2 N/A 1 1 / 4 150 ES40/1 115 6 3 / 4 18 1 / 4 22 1 / 4 N/A N/A N/A 12 N/A 1 1 / 4 34 ES40/2 200 6 3 / 4 24 1 / 4 28 3 / 4 N/A N/A N/A 12 N/A 1 1 / 4 39 EVR1 385 37 5 / 8 26 5 / 8 29 3 / 4 23 3 / 8 3 3 / 8 11 7 / 16 8 1 / 2 N/A 1 1 / 4 150 ERR1 ERR2 ERR3 ERR4 230 PL 330 PA 240 PL 355 PA 300 PL 435 PA 370 PL 500 PA 30 9 /16 34 13 /16 19 11 / 16 20 7 / 16 18 7 / 16 3 3 / 8 4 24 41 30 9 /16 34 13 /16 23 5 /8 24 3 /8 22 3 /8 3 3 / 8 4 24 1 1 / 2 47 vertical 30 9 /16 34 13 /16 29 1 /2 30 1 /4 28 1 /4 3 3 / 8 4 24 1 horizontal 58 47 1 /2 52 1 /2 19 11 /16 20 7 /16 18 7 /16 3 3 /8 4 40 15 /16 61 *Represents draw at steady state. Power could be higher during warm up. PL = Plated Finishes PA = Painted Finishes

08 Sealed Electric Wall & Floor Mounted Towel Warmers 6.0 Technical Data (cont) EO100/140 EO350 (Discontinued) ECMH 3/1 ECMH 3/2 ECMH 3/3 ECMH 3/7 Model Power* (Watts) Dimensions (ins) A B C D E F G H Tube diameter (ins) Approx shipping weight (lbs) EO100 EO140 EO350 ECMH3/1 ECMH3/2 ECMH3/3 ECMH3/7 95 PL 110 PA 135 PL 185 PA 190 PL 300 PA 75 PL 100 PA 100 PL 150 PA 75 PL 100 PA 75 PL 100 PA 25 1 /8 25 7 /8 23 1 /4 24 5 /8 20 10 4 13 11 /16 1 21 34 7 /8 35 5 /8 23 1 /4 24 5 /8 20 10 4 23 1 31 34 7 /8 35 5 /8 25 9 /16 26 15 /16 22 7 /8 7 15 /16 4 25 7 /16 1 40 21 1 /4 26 1 /4 17 1 /4 17 7 /8 15 1 /16 2 15 /16 4 7 /16 15 3 /8 1 1 / 2 vertical 20 35 1 /4 40 1 /4 17 1 /4 17 13 /16 15 1 /16 2 15 /16 4 7 /16 29 3 /8 1 horizontal 28 21 5 /8 27 3 /8 19 11 /16 20 7 /16 18 7 /16 4 3 /4 4 12 3 /16 1 1 / 4 vertical 24 21 5 /8 26 1 /16 17 1 /4 18 16 4 3 /4 4 12 3 /16 1 horizontal 24 *Represents draw at steady state. Power could be higher during warm up. PL = Plated Finishes PA = Painted Finishes

Sealed Electric Wall & Floor Mounted Towel Warmers 09 6.0 Technical Data (cont) ECM EMR EECOS Model Dimensions (ins) Power* (Watts) A B C D E F G H Tube diameter (ins) Approx shipping weight (lbs) ECM1 ECM2 ECM3 ECM4 EMR750 220 PL 235 PA 230 PL 225 PA 210 PL 320 PA 255 PL 475 PA 190 PL 225 PA 28 3 /4 33 5 /8 19 5 /16 19 3 /16 17 3 /16 3 1 /8 4 1 /2 22 7 /16 41 28 3 /4 33 5 /8 23 1 /4 23 3 /4 21 1 /8 3 1 /8 4 1 /2 22 7 /16 1 1 /2 vertical 47 D 28 3 /4 33 5 /8 29 1 /8 29 5 /8 27 3 1 /8 4 1 /2 22 7 /16 1 horizontal 58 oval tubes 47 1 /4 52 3 /16 19 5 /16 23 3 /4 17 3 /16 3 1 /8 4 1 /2 40 15 /16 61 29 15 /16 35 1 /2 19 11 /16 23 7 /8 18 7 /16 3 1 /8 4 23 5 /8 1 1 /4 & 1 39 EECOS85 200 33 15 /16 38 7 /8 19 11 /16 20 3 /16 12 3 11 /16 4 26 9 /16 40 EECOS86 200 33 15 /16 38 7 /8 23 5 /8 24 1 /8 16 3 11 /16 4 26 9 1 1 /2 /16 vertical 45 EECOS125 300 48 1 /8 53 1 /16 19 11 /16 20 3 /16 12 7 1 /4 4 33 11 /16 1 60 horizontal EECOS126 300 PL 48 1 /8 53 1 /16 23 5 /8 24 1 /8 16 7 1 /4 4 33 11 / 16 tubes 70 400 PA *Represents draw at steady state. Power could be higher during warm up. PL = Plated Finishes PA = Painted Finishes 6.0

10 Sealed Electric Wall & Floor Mounted Towel Warmers 6.0 Technical Data (cont) EGAV (Discontinued) EINT CAV (Discontinued) Model Dimensions (ins) Power* (Watts) A B C D E F G H Tube diameter (ins) Approx shipping weight (lbs) EGAV1 EGAV2 EGAV3 EGAV4 150 PL 250 PA 200 PL 300 PA 300 PL 400 PA 400 PL 500 PA 29 13 /16 34 13 /16 19 11 /16 23 1 /8 15 3 /4 3 3 /8 5 13 /16 N/A 40 29 13 /16 34 13 /16 23 5 /8 23 1 /8 19 1 /2 3 3 /8 6 3 /16 N/A 1 3 /16 vertical 46 7/8 48 1 /16 53 19 11 /16 41 5 /16 15 3 /4 3 3 /8 5 13 /16 N/A horizontal tubes 52 48 1 /16 53 23 5 /8 41 5 /16 19 1 /2 3 3 /8 6 3 /16 N/A 58 EINT1 250 20 7 /8 25 13 /16 19 11 /16 20 17 5 /8 3 1 /8 4 1 /8 13 40 EINT2 400 35 5 /8 40 9 /16 19 11 /16 20 17 5 /8 3 1 /8 4 1 /8 24 7 /16 Flat tube product 48 EINT3 500 65 3 /16 70 1 /8 19 11 /16 20 17 5 /8 3 1 /8 4 1 /8 57 1 /2 54 CAV1 250 44 1 /2 49 7 /16 25 9 /16 35 7 /16 2 4 1 /2 5 3 /16 N/A N/A 40 CAV2 500 56 5 /16 61 1 /4 25 9 /16 47 1 /4 2 4 1 /2 5 3 /16 N/A N/A 60 *Represents draw at steady state. Power could be higher during warm up. PL = Plated Finishes PA = Painted Finishes Electrical Specification The towel warmer requires 120VAC, 60Hz power supply. The towel warmer is to be protected by a separate 15 amp circuit breaker or equal. In accordance with our policy of continual improvement, we reserve the right to amend specifications without prior notice.

Sealed Electric Wall & Floor Mounted Towel Warmers 11 7.0 Operating Instructions The unit can be left on constantly if desired, without detrimental effect. The unit can be switched on or off using the control switch on the unit or using optional programmable timer. The temperature of the unit may vary during operation. Fabrics that contain soap, laundry detergent, liquid fabric softener or bath oil residue may show what appears to be scorch marks. This is simply discoloration due to the residue. The towel warmer does not reach sufficient temperature to scorch fabric. We are not responsible for fabric discoloration due to laundry detergent, softener or bath oil. As a precaution we recommend you place a towel directly onto the rail before placing items of clothing. IMPORTANT 8.0 Maintenance Cleaning: The finish of your MYSON towel warmer can be protected and maintained by an occasional wiping with a soft, non-abrasive, damp cloth then lightly polishing with a soft dry cloth when the towel warmer is cold. Under no circumstances should abrasive cleaning powders, metal polish or chlorine based cleaners be used on any part of this product. IMPORTANT CAUTION This product is filled with a precise quantity of liquid. Any leakage from the product, and any repairs that involve opening the product must be dealt with by the manufacturer or its representative. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person in order to avoid a hazard. The liquid in this product is not affected by temperatures below 0 F. Please contact your supplier in the event of any problems or if repair is needed. 8.0 7.0 6.0

MYSON Inc. 948 Hercules Drive, Suite 5, Colchester, Vermont VT 05446 T: (802) 654-7500, F: (802) 654 7022, info@mysoninc.com, www.mysoninc.com heatingthroughinnovation. 01.12.2010 ISSUE 3