Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Similar documents
Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

LABORATORY CABINETS 103

Laminar Flow Cabinets eco air V

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

INCREASE YOUR LAB EFFICIENCY

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Gelaire BH-EN and UltraSafe cabinets

Protection, safety, reliability. And more.

Microbiological Safety Cabinets

INCREASE YOUR LAB EFFICIENCY

LAMINAR FLOW FOR ALL YOUR NEEDS

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Down flow clean air cabinet Star of the Universe. Fortuna

INCREASE YOUR LAB EFFICIENCY

L a b o r a t o r y E q u i p m e n t C a t a l o g

Clean Bench Animal Transfer Stations

INCREASE YOUR LAB EFFICIENCY

BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

INCREASE YOUR LAB EFFICIENCY

Fortuna. Fortuna. »ScanLaf Probably the best in Class 1, Class 2 and Laminar flow technology.

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Mars. Mars Class 2. Microbiological Safety Cabinets. ScanLaf...Advanced Designs for your Safety & Comfort. Class 2 Safety Cabinets

laboratory & sterilization technology

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

INCREASE YOUR LAB EFFICIENCY

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Mars Pro. Mars Pro. Ultrasafe Class 2 An Ultrasafe Triple Filter - Microbiological Safety Cabinets. Cytosafe 3 filter Class 2 cabinets

CLEAN AIR SYSTEM.

2 Microbiological Safety Cabinet

Laboratory Automation & Robotic System Enclosures

The ultimate microbiological safety cabinet

IVF/ART Series Laminar Flow Cabinets

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

PROTECTION PRODUCT. Series CleanLamin AirFlow. Cabinets Series CLF, DLF and DLF/PCR

Innovation in air purification unmatched air quality

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Quick Reference Guide to Cabinet types

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

BioSafety Cabinet- Class 100

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Biological Safety Cabinets or Fume Hoods Which one to use?

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Biological Safety Cabinets. Biological Safety Cabinets

Environmental Health and Safety Biological Safety Program Guidance Document

Ergonomic and Green Class II s

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

PART III. Laboratory equipment

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Safe Operating Procedure (Revised 2/10)

CIRCULAIRE FORMALIN CONTAINMENT SYSTEMS.

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

LAMINAR FLOW AND VENTILATED SOLUTIONS FOR ALL YOUR NEEDS

Biological Safety Cabinet

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

VP, Facilities and Construction Management

6/19/2015 BIOLOGICAL SAFETY CABINET. Types of Classes. Types of BSC.

Class II ECO Generation 8 Microbiological Safety Cabinet

XPert Balance and Bulk Powder Enclosures

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

Control of Biological Hazards

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Precision Containment for All Applications

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

LAMINAR FLOW AND VENTILATED SOLUTIONS FOR ALL YOUR NEEDS

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

OPERATION AND MAINTENANCE MANUAL

Custom modular design to fit any application

SD-06AG Laboratory Scale Spray Dryer

Thermo Scientific 1300 Series A2

Laboratory Division. Product Range Cold Storage Clean Air Lyo

Laboratory Glassware Washer-Disinfectors

Laminar Flow Hoods and Booths

Aseptic Barrier Systems

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

for the next generation

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

TOPAIR CLEAN AIR SOLUTIONS CATALOG

Fume Hood Safety TYPES OF FUME HOODS

Double Skin Air Handling Units

CIRCULAIRE LAMINAR AIR FLOW

Low Noise, Class II Microbiological Safety Cabinets The Industry's Most Comfortable, Energy Efficient Cabinet

INDUSTRIAL VACUUM CLEANING INNOVATION. Industrial vacuum cleaners

Transcription:

Faster BH-EN and BHG Class II Microbiological Safety Cabinets Protection, safety, reliability. And more.

APPLICATIONS BH-EN and BHG Class II Microbiological Safety Cabinets have been adopted worldwide for product, personnel and environmental protection while handling harmful agents pathogenic to human beings and/or animals as defined in the appropriate international standards, in a wide range of applications such as: Microbiology, Virology, Haematology, Cell culture, Genetics, Handling of hazardous agents to human beings or animals.

BEYOND MINIMUM SAFETY REQUIREMENTS BH-EN and BHG Microbiological Safety Cabinets belong to the latest generation of laminar airflow systems manufactured by Faster S.r.l., in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards. BH-EN and BHG vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469:2000 European Standard, with 70% of the air re-circulated via the main H14 HEPA filter within the cabinet, whilst the remaining 30% is discharged through an exhaust H14 HEPA filter. Safety Cabinets with automatic regulation and microprocessor based monitoring systems. These cabinets are suitable for handling micro-organisms and pathogens as defined by the appropriate European and other International Standards, current health and safety guidelines and legislation aimed at safeguarding health and safety of operators at work. BH-EN fitted with hinged frontal safety glass-sash window. BHG cabinet features an ergonomically angled slopingfront, fitted with electrically operated vertically sliding safety-glass sash window, the framework of which is also hinged and can be opened up for easy access during cleaning and maintenance.

SUPERIOR FEATURES Stratified safety-glass front sash window - and work chamber in stainless steel AISI 304L, designed to conform to requirements and pass the cleanability tests according to EN12469:2000. UV sterilizing lamp (optional) installed on the front closure-panel of the BH-EN model and on the rear wall of the work chamber of the BHG model, complete with two switch-off countdown timers, one variable on a 0 3 hours scale (1 minute steps), the other set to 3 fixed hours. Work Surface in stainless steel AISI-316L, consisting of sections which are easily removable for carrying out routine cleaning and/or require autoclaving sterilization procedures; perforated to ensure an optimum degree of laminarity of the airflow, together with a high resistance factor to the most effective chemical agents used for disinfection. Re-circulating and extractor fans: BH-EN and BHG Microbiological Safety Cabinets S -Series are supplied with single centrifugal fan, whilst models of the D Series with double centrifugal fan to provide complete operator, product and environmental protection. Moreover the D models fitted with double motor-fan are designed and are also suitable to discharge the filtered air outside the laboratory through a ducting system if required. Microprocessor based monitoring system: full status report provided via 2-line digital display by the new generation microprocessors - which automatically control all functions and all safety alarm systems ensuring that performance characteristics are maintained to EN12469:2000 requirements. The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation - and in particular respect: display of laminar airflow velocity and frontal air barrier velocity display of inside and outside temperature display of residual lifetime of HEPA filters, UV Lamp and activated carbon filter (if fitted) display of total number of hours of operation display of saturation level of HEPA filters. Audio-visual alarms provided for: Out of range or incorrect laminar airflow velocity and frontal air barrier velocity front sash-window open saturation of HEPA filters end of life-cycle of UV lamp and saturation of activated carbon filter (if fitted) blockage in the exhaust duct signal of fan-motor malfunction power failure.

TECHNICAL SPECIFICATIONS Code Dimension (mm) Power Supply Weight Front Aperture Height Noise Vibrations Lighting Exhaust Duct diameter Usefull Overall WxHxD WxHxD Kw VHz Kg mm dba mm/rms Lux mm ø C BH-EN 2003-S F74 600110 885 1090 0.7 181 BH-EN 2004-S F74 600120 1190 1395 1.0 213 BH-EN 2005-S F74 600130 1495 1700 1.2 260 BH-EN 2006-S F74 600140 1800 2005 1.4 298 BH-EN 2003-D F74 600210 885 1090 0.85 186 BH-EN 2004-D F74 600220 1190 1395 1.1 218 BH-EN 2005-D F74 600230 1495 1700 1.3 265 BH-EN 2006-D F74 600240 1800 2005 1.5 304 660x580 1470x785 230/50 200/250 < 59 < 0,004 > 1000 200 Temperature rise < 4 BHG 2003-S F74 700110 885 1090 0.7 191 BHG 2004-S F74 700120 1190 1395 1.0 223 BHG 2006-S F74 700140 1800 2005 1.4 310 BHG 2003-D F74 700210 885 1090 0.85 196 BHG 2004-D F74 700220 1190 1395 1.1 228 BHG 2006-D F74 700240 1800 2005 1.5 314 655x606 1470x830 230/50 200 < 59 < 0,004 > 1000 200 < 4 ACCESSORIES F74 600500 F74 700500 F74 501010 F74 501015 F74 501025 F74 501020 F74 700910 F74 700920 F74 700940 F72 701050 F72 702020 F72 799521 F72 799510 F72 702050 F72 702060 F72 709077 F72 709176 F72 709177 F72 709178 F72 709179 F74 500800 UV lamp for BH-EN UV lamp for BHG Epoxy powder painted modular stand for BH-EN 2003 S/D Epoxy powder painted modular stand for BH-EN 2004 S/D Epoxy powder painted modular stand for BH-EN 2005 S/D Epoxy powder painted modular stand for BH-EN 2006 S/D Epoxy powder painted modular stand for BH-G 2003 S/D Epoxy powder painted modular stand for BH-G 2004 S/D Epoxy powder painted modular stand for BH-G 2006 S/D 3-Drawers unit on pivotting wheels Additional exhaust carbon filter for BH-EN and BHG (only D model) Additional exhaust HEPA filter for BH-EN and BHG (only D model) Anti-blowback valve Additional service connection for electrical power Additional service connection for gas/vacuum (manual tap) Volt free contact Stainless steel bar for bags to be fitted on BH-EN/BHG 2003 S/D Stainless steel bar for bags to be fitted on BH-EN/BHG 2004 S/D Stainless steel bar for bags to be fitted on BH-EN/BHG 2005 S/D Stainless steel bar for bags to be fitted on BH-EN/BHG 2006 S/D Formalin vaporiser OPERATIONAL PRINCIPLES The ambient air is drawn in from the slots at the stainless-steel base of the front opening and it then passes under the work surface, from where it is drawn up and blown into the plenum of the re-circulating and exhaust fan(s). The bio-dynamic sealing system of the negative pressure plenum ensures that all contaminated particles are kept inside the system and are automatically drawn to the plenum or pressure chamber to be captured by the main re-circulating and exhaust HEPA filters. The fan system assures that no part of the cabinet comes ever under positive contaminated pressure to the laboratory, thus protecting and preserving the environment and operating personnel from exposure to agents of bio-contamination. 70% of the filtered air is re-circulated (after passing through a H14 HEPA) in a ISO 5 laminar flow pattern downwards into the work chamber and the remaining 30% is exhausted to atmosphere through another H14 HEPA filter. External air Sterile air Recirculated air BH-EN BHG