Laminar Flow Cabinets eco air V

Similar documents
Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

Microbiological Safety Cabinets

ENVAIR lab CO2 Incubator

ENVAIR lab CO2 Tri-Gas Incubator

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

LABORATORY CABINETS 103

Gelaire BH-EN and UltraSafe cabinets

Class II ECO Generation 8 Microbiological Safety Cabinet

L a b o r a t o r y E q u i p m e n t C a t a l o g

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

2 Microbiological Safety Cabinet

CLEAN AIR SYSTEM.

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

OPERATION AND MAINTENANCE MANUAL

OUR TRUSTED SERVICE & SUPPORT

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Laminar Flow Hoods and Booths

Laboratory Automation & Robotic System Enclosures

INCREASE YOUR LAB EFFICIENCY

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

Biological Safety Cabinet

Mars Pro. Mars Pro. Ultrasafe Class 2 An Ultrasafe Triple Filter - Microbiological Safety Cabinets. Cytosafe 3 filter Class 2 cabinets

laboratory & sterilization technology

PROTECTION PRODUCT. Series CleanLamin AirFlow. Cabinets Series CLF, DLF and DLF/PCR

Mars. Mars Class 2. Microbiological Safety Cabinets. ScanLaf...Advanced Designs for your Safety & Comfort. Class 2 Safety Cabinets

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

INCREASE YOUR LAB EFFICIENCY

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Maximum protection for your health and well-being

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

INCREASE YOUR LAB EFFICIENCY

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Innovation in air purification unmatched air quality

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Biological Safety Cabinets or Fume Hoods Which one to use?

INCREASE YOUR LAB EFFICIENCY

Thermo Scientific 1300 Series A2

IVF/ART Series Laminar Flow Cabinets

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

PRODUCT LINE ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR PRODUCTS LAMINAR AIR FLOW WORK STATION: (Vertical and Horizontal) Construction made

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

The ultimate microbiological safety cabinet

CIRCULAIRE LAMINAR AIR FLOW

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

How to comply with CDC Guidelines

LAMINAR FLOW AND VENTILATED SOLUTIONS FOR ALL YOUR NEEDS

Model KBWF 240 Growth chambers with light and humidity

Setting new Standards for Safety Containment. Comfort. Convenience. Thermo Scientific HERASAFE KS and KSP Class II Biological Safety Cabinets


Model KBF 240 Constant climate chambers with large temperature / humidity range

Environmental Health and Safety Biological Safety Program Guidance Document

Equipment guide for local exhaust ventilation (LEV)

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

CIRCULAIRE FORMALIN CONTAINMENT SYSTEMS.

DOWNDRAFT BENCH SERIES

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Laboratory Division. Product Range Cold Storage Clean Air Lyo

Clarification Proposal Annex 1, PDA: A Global. Cleanroom and. Association. Clean Air Devices. Hasim Solmaz Lighthouse Worldwide Solutions

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Laboratory & Process Equipment

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

A look into our complete product collection.

LAMINAR FLOW AND VENTILATED SOLUTIONS FOR ALL YOUR NEEDS

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

Zefiro Line. Ventilated workstation for anatomic pathology. The quality is in the air

Model KBWF 720 Growth chambers with light and humidity

Fortuna. Fortuna. »ScanLaf Probably the best in Class 1, Class 2 and Laminar flow technology.

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

BioSafety Cabinet- Class 100

TOPAIR CLEAN AIR SOLUTIONS CATALOG

Quick Reference Guide to Cabinet types

CREATING A CLEANER ENVIRONMENT EAZIFLO FUME CAPTURE SYSTEM

Hand Dryer Installation & User Manual

Precision Containment for All Applications

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)

VWR symphony CO 2 INCUBATORS

INCREASE YOUR LAB EFFICIENCY

for the next generation

Transcription:

Laminar Flow Cabinets eco air V Class ISO 3 Vertical product protection cabinet Standard EN ISO 14644-1 Breite (m) 0.6 / 0.9 / 1.2 1.5 / 1.8

Clean technology for a clean environment eco air V the clean generation eco air V cabinets are ISO Class 3 vertical laminar flow cabinets which represent far more economical and valid alternatives to cleanrooms, as they are capable of providing uncontaminated, particlefree and sterile conditions for materials in the work-space. They guarantee and maintain excellent product protection factors by offering a decontaminated working area by virtue of the G3 prefilter - and a HEPA filter with an efficiency exceeding 99,995 % MPPS (H14 - EN: 1822). The eco air V vertical laminar airflow cabinets have epoxy powder coated steel structures and an AISI 304L stainless steel working surface as standard. Multifunctional Keyboard Opening frontal screen Cabinet incl. 1/2 electrical sockets optional: safety service connection for gas and vacuum Safety glass side-window Stainless steel work surface

Technology of today for the world of tomorrow eco air V LAF Cabinets have been adopted in use for pro-duct protection from airborne contamination or while handling nonpathogenic biological specimen in applications such as: Sterility Test, Microbiology, In Vitro Fertilization, Preparation of ophthalmic solutions, Preparation of culture media, Assembly of electronic devices, Nutritional Parenteral Therapy, Assembly of medical devices. Operational Principles The ambient air is drawn in from the top through the upper part of the cabinet via a pre-filter and it then passes after filtration through a HEPA filter into the working area in a vertical laminar air flow pattern and exhausted outside. Special Attributes Anti bacterial coating Each cabinet is coated with exclusive Dupont ALESTA antibacterial Ag+ cationsbased solution, capable to prevent micro-bial contamination of surfaces thereby inhibiting long term surface growth. Wall Side Transparent side walls in safety glass and flexible frontal closure shutter (available as an option). Standard outlets An electric socket is standard with models V 1.2, V 1.5 and V 1.8 UV sterilizing Lamp UV sterilizing lamp available as added option - complete with a flexible front shutter in order to close the working area from dust and for the safety of operators. Features Structure of the eco air V vertical LAF cabinets is in epoxy powder coated cold-rolled steel for excellent corrosion resistance to the attack by aggressive common chemicals. Alternatively special models made in AISI 304L stainless steel for superior cleanability are also available on demand. Airflow Cabinet elements

Our technology protects human and environment User-friendly keyboard Membrane keyboard front panel with touchsensitive buttons for: main On/Off switch light power socket night mode and UV lamp Configuration overview opening frontal screen for easy cleaning 1 electrical socket at 1.2m 2 electrical sockets at 1.5m und 1.8m It is fitted with digital display for indicating air velocity, and the relevant alarms in case the cabinet is equipped with anemometer and automatic airflow control. Tailor-made Cabinets Special cabinets are manufactured as per customer s requirements on demand.

Technical specifications Description Unit eco air V 1.2m 1.5m 1.8m Overall Dimensions WxHxD (1) mm 1332x780x1495 1637x780x1495 1942x780x1495 Useful Dimensions WxHxD mm 1190x625x710 1495x625x710 1800x625x710 Working aperture mm 250 Net Weight kg 192 274 325 Gross Weight kg 242 333 395 Noise level (2) db(a) <60 Electrical Data 1Ph+E - 230V 50Hz Power consumption W 900 1400 1400 Options and Accessories UV Light Aluminium night door closure Epoxy powder painted modular stand Epoxy powder painted modular stand with Castors Service connection for electrical power Gas tap Vacuum tap Compressed air tap Nitrogen tap Automatic speed regulator and digital anemometer Digital Display Differential pressure gauge (Magnehelic) Legend: electrical sockets installed Low power consumption Work zone rear wall varnished

Service in pure culture service in pure culture. We do not simply sell our units to you but will assist you gladly from A to Z. Delivery: We deliver all units ex works. Set-up service and packaging disposal are included upon request. Service: 24h at site service and 24h free of charge phone hotline 7 days a week Maintenance: Microbiological Safety Cabinets DIN 12469 Cytotoxic Dispensing Cabinets with KI-discus test DIN 12980 Product Protection Cabinets Laboratory Fume Hoods Cytotoxic Dispensing Isolator EN 14644-7 Isolator EN 14644-7 Cleanrooms Service by professional staff. All works are carried out by service technicians qualified by TÜV Nord Spare parts guaranty: 10 years Availability within 24h Ex stock Emmendingen Qualification: IQ/OQ GMP GAMP 21 CFR Part 11 Decontamination: We carry out microbiological decontaminations with most modern H2O2 generators or Formalin units in Cleanrooms, Isolators and Safety Cabinets Maintenance contract: Regular terms of maintenance increase your safety. With a maintenance contract we guarantee the complete check of all functions of your units. We will contact you reliably in regular terms. Guaranty and Warranty: Combined with an maintenance contract we offer a 2-year warranty to all units. Excepted are consumables and wearing parts as well as compressed air components.