TREATMENT ROOM DATA SHEETS

Similar documents
TREATMENT ROOM DATA SHEETS

TREATMENT ROOM DATA SHEETS

TREATMENT ROOM DATA SHEETS

TREATMENT ROOM DATA SHEETS

LIVE WORK SHOP PLAY WESTGATE AT THE GLEN

Bath Planning Worksheet

Estimate Form for Kitchen Design and Installation

Pharmette Medicine Centers

Scope of Work - Single Family, San Diego, CA

Tortolita Preserve - Home Site 8

Interior & Exterior Finishes & Specifications for The Bradford & Weston Style Homes

Library stacks and records storage 150 LB/SF live load

SUNSET RIDGE. We measure our success. by the size of your smile! San Jacinto Division

Scope of Work Single Family, San Diego, CA

Platinum Features - Multi Section

Luckdrops. Technical Spec Sheet. Studio+ Modular Home

UNIT TYPES: B (1 beds) C (2 beds) D (3 beds) E & F (Penthouse)

FENG SHUI SAVVY. Penthouse & Sub-penthouse suite finishes

C O V E S E R I E S NealCommunities.com SOuthwESt FlORIda S most ExpERIEnCEd home builder FOR OVER 40 years

Bathroom remodeling Dictionary

Styling Chairs. All Purpose Chairs Tiki 20 w Black Vinyl Seat Seat Height H2 Square Base Standard Upgrades Available

FEATURES UPGRADES AVAILABLE

22576 INSPIRATION POINT INTERIOR FEATURES BY ROOM

SPACE TYPE: JUDICIAL CHAMBER

McLean Overlake New Home Features

Scope of Work - Single Family, Oceanside, CA

McLean Overlake New Home Features

Front Door and Entrance Hall

FEATURES Marquesa Circle, Naples, FL MarquesaIslesFl.com

Modern Exteriors Stylish Kitchens Designer Bathrooms Comtemporary Living Fixtures & Finishes Schedule Inclusions Brochure

L A signature series TA T N E RE O, A L L A T S IN

Structural Guidelines. Food Service Establishments. Retail Food Stores

Outdoor Kitchen Design By Carol Lamkins, CMKBD, CID

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

LUXURY HOME BED 3 BATH

Scope of Work Condominium, Carlsbad, CA

PALM HAVEN. We measure our success. by the size of your smile! San Jacinto Division

WORK DESCRIPTION HOUSING REHABILITATION PROGRAM HOUSING DEVELOPMENT DIVISION CITY OF COLORADO SPRINGS

User Manual / Care Instructions

Food Service Plan Review Information

Elevation of twelve-home building

About This Model. Series: Timberland Ranch Model: TL815A. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: Notes:

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

McLean Overlake New Home Features

Where value-oriented meets family-oriented.

AMBER COVE. We measure our success. San Jacinto Division. By the size of your smile!

Astro Ranch Homes. Homes Worth Looking Into!

Landscape Includes sprinkler system Irrigation, system maintenance, and landscape upkeep are all included in H.O.A. dues

Nims Village New Home Features

FEATURES. Space-saving, full-size front-loading two piece energy efficient stacking washer and dryer In-suite security system

PRELIMINARY A NEIGHBORHOOD BY TRI POINTE HOMES

2017 Beaver Run Refurbishment Department Flip Packet for Homeowners

Scope of Work -Single Family Home, San Diego, CA

A New Home Community by

Elevations. Nova at the Vale

Scope of Work - Single Family, Carlsbad, CA

Scope of Work - Single Family, Escondido, CA

2018 Beaver Run Refurbishment Department Flip Packet for Homeowners

Astro Ranch Homes. Homes Worth Looking Into!

Scope of Work Condominium, San Diego, CA

Project Cost: $157,800

About This Model. Series: Blue Ridge MAX Model: B Grandview Max. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: 1638.

PRESIDENTIAL SERIES 1

CABINETRY. KITCHEN Style Source West Wall Upper Cabinets. Flat Panel Framed Frosted Glass or Flat Panel. Flat Panel

Examples of Acclaim s Energy-Efficiency Green Technology

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

Daniels Place INCLUDED FEATURES Wildlife Preserve Lane, Fort Myers, FL Daniels-Place.com

CLASSIC. SIDE CABINET Installation Instructions

Astro Ranch Homes. Homes Worth Looking Into!

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

About This Model. Series: Pennwest 2-Story Modular Model: HA402A Pennwest Ultra 5. Style: 2-Story / Bedrooms: 3 / Bathrooms: 3 / Square Feet: 2579

Camden. Included Features. Prices are non-negotiable. Continued on Back ATTRACTIVE INTERIORS:

MULTI-SECTION HIGHLAND ESTATES SERIES

PRELIMINARY A NEIGHBORHOOD BY TRI POINTE HOMES

Universal Design Checklist

Plan 1. Preliminary. 2 Bedrooms. Optional Bedroom 3. Optional California Room. 2 Baths. Den. Optional Bonus Room

Multi Family, New Haven, CT


THERE IS NOTHING STANDARD ABOUT OUR FIXTURES AND FINISHES.

Pathway Lighting. Introduction

MAITLAND MEADOW SUBDIVISION CUSTOMIZED OPTIONS

Wythe County Buildings and Grounds Courtroom renovation located in the Wythe County Circuit Court

room data sheet GASTOWN HOTEL 110 WATER STREET, VANCOUVER, BC 1/11 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

Scope of Work Condominium, San Diego, CA

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

28', 32' AND 42' SERIES FLOOR PLANS

146 Westrose Avenue

FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN

Single Family, National City, CA

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

AGING IN PLACE CHECKLIST Use this checklist to identify fall hazards and accessibility for the homeowner and family members.

Walnut Park. residence E. Quality Features. 4 Bedroom, 2-1/2 Bath Approx. 1,934 SQ.FT.

Astro Ranch Homes HUD & Value Modular

Eastland Ranch. HUD & Value Modular. Photos Top to Bottom: A3177A, A3177A & A3162A. Diamond Anniversary. est. 1952

Scope of Work - Single Family, Escondido, CA

About This Model. Series: Rockbridge Modular Homes Model: RJ501A Grand Rockwell. Style: Ranch / Bedrooms: 4 / Bathrooms: 2 / Square Feet: 2280.

Wood Manor. Developer. 24/28/32 Series. Developer. Your Local Wood Manor Dealer is: Some Items Shown May Be Optional

KINGS CROWN CONDOS.

Transcription:

SPECIALTY - GROOMING ROOM A. Basics A grooming room is set up to be able to do all beauty or grooming treatments in private luxury (pedicures, manicures, facials) Each room is equipped with a mandatory brand signature table that is multipurpose, hydraulic, four-legged and padded with built in foot sink and floor drain. Three feet of space [914mm] must be allowed around the table to allow effective treatments that are ergonomically healthy for therapists. All rooms must have sinks and counters equipped with locked cupboards, wall mounted towel warmers (or warming drawers). Hot towel cabinets are be built in to the millwork. Each room is individually adjustable for lighting (all dimmable); temperature and music. Air-flow is away from the treatment table. The head of the bed is best positioned towards the sink for easy access of the service provider. All equipment (facial trolleys, steamers, hot stones) needs to have hidden storage cupboard to be out of sight of guests. This room is also equipment with a t.v. with wireless headsets for guests to use during the treatment. The following illustrations depict a standard layout for this treatment room including the following data: standard layout, typical equipment to brand specifications, typical locations for electrical outlets and control switches and minimum space requirements. For details on equipment, refer to Equipment Specifications Book or www.swissotelspastandards.com. Swissôtel Pürovel Spa Specialty Grooming Room: Page 1 of 8

Swissôtel Pürovel Spa Specialty Grooming Room: Page 2 of 8

EQUIPMENT SPECIFICATIONS: SPECIALTY ROOM - GROOMING ROOM Total Room Area: 14.3 m² / 154 ft² Equip. # Image Description Electrical Plumbing Outlet Item # Installed By NFX-1 The Series 2100 Classic autoclave, with its reputation for reliability, durability and quality, remains the most cost effective solution. Voltage as 1500 Watts Adjacent Outlet AM210001- NFX-6 This version of the Golden Touch Package comes without the Hot Towel Cabinet. The ultimate in multi-function convenience. Water pump: 12-volt DC centrifugal pump, 8-amp, w/110- volt/12-volt DC transformer 2.5 Amps, 350 Watts. Motor: 24V DC 3/4" washing machine type hose bibs, drain feeds to 1" flexible hose to floor drain.. Outlet under table, GFCI dedicated circuit TA13960P NC- Client's Contractor NFX-16 This medium sized cabinet is designed to keep pre-moistened towels at a temperature of 158-176 F (70-80 C). 13 liter capacity holds approx. 18 face cloths. Features UV, 200 Watts, specify plug type Comes with UL listed battery charger TJHC12UV- NFX-20 Durable construction of this medical-grade gel warmer allows countertop use or wall mount. 7 Watts, 50/60Hz Adjacent to Unit PL82-01-20-230V NFX-25 Custom Treatment Trolley with wood veneer finish on sides and top. Includes one drawer, one fixed shelf and one adjustable shelf. 3" rubber casters and power strip is attached to rear of cart. 50 Hz, 10 Amps Adjacent to Unit CUTRL NFX-32 This sleek steam system features an aromatherapy container for the addition of aromatic oils. Its computerized operation... 50Hz SQD280- Swissôtel Pürovel Spa Specialty Grooming Room: Page 3 of 8

Equip. # Image Description Electrical Plumbing Outlet Item # Installed By NFX-42 Teflon coated, this wax melter promotes easier cleaning and includes a built in thermostat for heat and temperature control. 220 NFX-30 Seat height adjustable from 17"- 23" with backrest, lumbar support, black base with 5 casters. Standard fabric colors in Soft White. appropriate. European Schuko type E/F hybrid plug. Hard wired, Built-in GFCI PE921-12- ST13358 N/A FX-20 Wall mount, high quality chrome complete with all hardware. Includes Wire kit.. 100 Rated Watts MYTEO130- Client's Contractor GENERAL Dimensions: Minimum 11 [3.35m] x 14 [4.27m] to (14.31 m 2 or 154 ft 2 ) Allow at least 3 ft. [.93m] of space on all sides of the treatment table Sound Separation: Sound proofing between rooms, water pipes, drains and doors. Sound separation STC 54 minimum for all walls. Doors: Solid core Silent closing devices Window: Locate on wall opposite from entry door where possible Sound proof Window Treatment: Obscure/covered (black-out) Swissôtel Pürovel Spa Specialty Grooming Room: Page 4 of 8

Wall: Standard dry wall construction Where possible, all finishes should be rated Green ; made from environmentally friendly materials. Semi-gloss or satin finish preferred in dry areas Flooring: Wood or carpet is acceptable, but must be easily cleaned and textures or color ranges should hide any minor spills. Tile is required under the table surrounding the drain but not visible t the guest. Ceiling: Fully enclosed (no drop ceilings) B. MILLWORK: (refer to Spa & Fitness Typical Millwork/Joinery Drawings shown below) Cabinets are lockable mastered (see room layouts) to store clean linen and supplies. Countertops are standard 35-36 [89-90 cm] high and have at least 5 linear feet [152 cm] of surface space. The surface is to be stain resistant, have a smooth surface and be easily cleaned. Hot towel cabinets should be placed on an open shelf in the upper cabinet. This space needs to be minimum of 2 6 wide (762), 1 3 high (381) and 1 2 deep (356) to fit the specified equipment. Must have electrical at shelf height. Custom trolley to match the millwork All equipment must be able to be rolled into closet in millwork Swissôtel Pürovel Spa Specialty Grooming Room: Page 5 of 8

C. EQUIPMENT (FIXED ONLY) Hand sink at counter is flush to countertop, with either lever handles or one handle temperature controls. Faucet is goose neck style at least 8 [20.32cm] height above sink top and should not splash or make noise when water is on. E.g. Stillness deck mount faucet K-956 from Kohler Towel warmer is hard wired hot towel warmer is required positioned on wall near door side or as positioned in drawings. Option to provide heated drawers in millwork for towels. Wall mounted flat screen t.v Swissôtel Pürovel Spa Specialty Grooming Room: Page 6 of 8

D. MECHANICAL ELECTRICAL PLUMPING (MEP) HVAC: Each room must have independently controlled HVAC unit with full temperature range. Supply grills and airflow are directed away from the tables. Slot vents are preferred and all intakes are hidden. Access panels are discretely placed - above the door or out the line of sight when guests enter. All heating and air conditioning vents must be silent and placed to avoid blowing on clients. Humidity Level: Low PLUMBING Drain: Sink waste at working counter Treatment table has a ¾ washing machine type hose bibs to feed a 1 ½ inch OD flexible hose to 1 ½ floor drain (see specifications of the treatment table) Fire Suppression: Per Code ELECTRICAL Power Electrical Outlets: Two 110v/220v 15 amps GFCI outlet at counter Quad under table GFI protected and supplied from 120V AC, 15 amp circuit breaker, outlet recessed in floor under the center of the table. If monument is required, must be no higher than 2 )50.8mm) Two wall locations of 110v/220v 15 amps 12 AFF on wall opposite wall of counter and side wall away from door 110v/220v 15 amps GFCI outlet located behind the Hot Cabinet (either to far right or left side to allow or plug). TV Electrical and Cable for wall mounted t.v. at end of treatment room (for positioning see typical layout) See locations on sample layout. Swissôtel Pürovel Spa Specialty Grooming Room: Page 7 of 8

Lighting: All lights are dimmable and indirect. Two wall sconces minimum are provided One attractive ceiling mounted light over the table or cove lighting around the room One task light under cabinet over countertop. Place control for this light at countertop location. All controls are to be low tech and simple to operate adjacent to other controls at the door entry. Music: Control for selection of music of minimum of 8 channels from a central system with a volume control Speakers are of high quality, recessed in the ceiling. For sound system requirements refer to Section P of Design Standards Telephone: Not required E. OTHER Fixtures: Robe hook located behind arrival door Signage: Small number beside each door outside room (names are optional to add) Small dowel/hook under the number for hanging in use/not in use symbol Local Code: Take into consideration all spa licensing requirements as well as zoning, building codes and permits, labor unions, fire safety codes, water, sewage, electrical code and ADA requirements as they relate to your area. Check all Local Department of Health, State Board and health and safety regulations. Swissôtel Pürovel Spa Specialty Grooming Room: Page 8 of 8