Precision Temperature Control. Pulse Free Pump. Column Oven. Superb Performance Ion Chromatography. Leak Detector. Modular Flexibility

Similar documents
BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

HPLC Column Ovens and Temperature Controllers

Customised HPLC Systems for Highest Performance

Thermo Scientific Dionex Integrion HPIC System

NOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE

IC Professional Detector

Nexera-i Specifications Prominence-i Specifications

t. +44 (0) f. +44 (0) e. w.

300 series HPLC autosamplers

Agilent 1290 Infinity II Vialsampler Data Sheet

Datalogging as standard

CALIDUS tm the Modular micro Gas Chromatograph

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

Common Features of DX-600 Modules

intrinsically safe detector for hydrocarbon gases

Analyze IT. Process Gas Chromatograph. PGC2000 Series

Mercury Vapor Monitor VM-3000

Who is GBC Scientific Equipment?

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

portable gas analyser

930 Compact IC Flex. 930 Compact IC Flex Oven SeS/PP/Deg. Manual Short Instructions EN /

portable gas analyser

940 Professional IC Vario

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

gas monitoring system

Spark Holland introduces

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

VM-3000 Mercury Vapor Monitor

931D Style B Process Gas Chromatograph

ProStar 325 UV-Vis Detector

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

Air & Water Heat Pump R832

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

QAQC LABS ANALYTICAL DRYING

Agilent 1100 Series Refractive Index Detector. Reference Manual

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Perkin Elmer Clarus 500 Gas Chromatograph

Mechanical Heat Pump R515

SECTION Free/Available Chlorine Analysis System

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

detectors UltiMate 3000 Variable Wavelength Detectors

Customers should provide all necessary operating supplies upon request of the engineer.

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

PRODUCT LINE. Highest Quality, Best Service

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

continuous emissions monitoring Combustion & Environmental Monitoring

VM-3000 Mercury Vapor Monitor

Technical specifications of FT-IR Spectrometer

Recent Improvements in Process GC Instrumentation

Parker icount Oil Sampler (IOS)

EC 160 CO 2. Incubator

Gas Detection - GD -

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Process Gas Chromatograph

Specifications Wavelength Range: 190 nm to 800 nm continuous

Agilent 1260 Infinity Multi-Detector Suite

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

PUV, PIR and PFO Series BROCHURE

The New Digital BWB Flame Photometer Range

TC-PLUS Thermal Cyclers

HFID Heated Total Hydrocarbon Analyzer Module

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

laboratory & sterilization technology

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

CS744 Series: Carbon/Sulfur by Combustion

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

DP 300 mobile dew point instrument

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Steam and Water Analysers

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

F-900 Portable Ethylene Analyzer

Model Q45P/R. ph/orp Monitor...

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

ZXSe Range Data Sheet

Accessories for WHA 3000P and WHA 3000V

STRIKE GUARD DELIVERS:

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

SiteSentinel itouch Console

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Model Q45P/R. ph/orp Monitor...

(Inside illumination as option available.) Biogas Batch Fermentation System. With Automatic Data Logging in Real Time

AS950 REFRIGERATED SAMPLERS

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

PHOENIXL 300 New Standards in Leak Testing. Technical information

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Features and Benefits

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Transcription:

COMPLETE ION CHROMATOGRAPHY

COMPLETE ANALYTICAL SYSTEMS Precision Temperature Control The eluent background conductivity changes by about 2% for a 1ºC change in temperature. The cell temperature controlled enclosure temperature may be set by the operator to avoid ambient changes causing drift. The default value is set at 35ºC and controlled to better than ±0.01ºC. Temperature compensation is not therefore required. Pulse Free Pump Mobile phase pumping is provided by a dual piston, digitally controlled, pump. Electronic feedback control virtually eliminates pulsing without using mechanical damping. Column Oven The very precisely temperature controlled oven accommodates Anion and Cation columns and precolumns, as well as a background suppressor cartridge with its over pressure protection valve. Superb Performance Ion Chromatography The completely new Ion Chromatography system from Cecil Instruments IonQuest is a top performance modular system. The conductivity cell is enclosed with a heat exchanger in a precisely thermostatted enclosure. The temperature of the enclosure is controlled to better than ±0.01ºC. The working temperature may be set by the operator to be between 25ºC and 50ºC and set with a default value of 35ºC during production testing. Modular Flexibility The system is easy to use by control panel operation, or by using the sophisticated Cecil PowerStream software for data acquisition, processing and reporting. Full system control is also provided by the workstation equipped with PowerStream. The modularity of the system enables its configuration to be changed with ease, for instance to use a UV/Visible detector. Modules may readily be replaced, to reduce down-time, should the need arise. Close coupling to the detector provides high stability, low noise and low dispersion. Leak Detector A specially designed leak detection system is accommodated within the cell oven enclosure. The detection system may be used to shutdown the system if a leak is detected in the enclosure. PowerStream Software This software, developed by Cecil Instruments, provides system control and superb data processing, manipulation and reporting with truly unrivalled ease. 2

FOR ION CHROMATOGRAPHY Detector Advanced Design The CE4710 Conductivity Detector is an entirely new design from Cecil Instruments providing performance of the very highest order due to its exceptionally low noise and unrivalled baseline stability. To achieve this standard of performance a very low volume, 0.5µL, conductivity cell has been designed and is operated in a precisely thermostatted aluminium oven enclosure. A specially designed, low dispersion, heat exchanger, is also mounted in the cell enclosure preceding the detector cell. The exchanger stabilises the temperature of the mobile phase entering the cell. With the enclosed system controlled to better than ±0.01ºC superb performance is always available. Autozero and auto-range facilities are provided to ensure convenience of operation. Built-in diagnostics aids instrument evaluation and fault finding. The temperature controlled cell and heat exchanger enclosure is conveniently accessed from the side of the detector module, as shown in the photograph. Chemically Suppressed Solvent Background Sensitivity for the measurement of anions is greatly improved by reducing the conductivity of the eluent, post column. An optional Anion Membrane Suppressor - SAMS - is available which is mounted in the column oven, in series with and after the analytical column. The suppressor may be used continuously and is regenerated by a Continuous Anion Regeneration System - CARS -, which pumps the regeneration fluid through the post column suppressor cartridge. The suppressed solvent background conductivity leads to reduced drift and noise and therefore higher sensitivity for measurements is available. Close Coupling to Oven Close coupling of the detector to the oven is important in eliminating the effects of ambient temperature fluctuation on results. The couplers can be seen on the side of the detector. Detector Features Full control by PowerStream software workstation Keypad and LCD interface, for local operation, when required Large memory for analytical methods Autozero for operator convenience Operator selectable cell temperature; default 35ºC Leak detection system shutdown. Important for unattended operation. Self diagnostics to confirm instrument function Mounting facility for Rheodyne injection valve Calculation of detector cell constant not required Polarity switching The cell compartment thermostatted enclosure is shown in the lower photograph, with the side cover removed for easy access. 3

DATA PROCESSING + CONTROL Pump-Proven Performance The Cecil CE4100 dual piston solvent delivery pump is well established as very reliable, convenient to use, with a very high performance specification. The microprocessor controlled pump uses a precise stepping motor drive for the dual overlapping pistons which deliver solvent with very little pulsing. Electronic feedback is used to control the pump speed during its cycle to reduce pulsing to a negligible level. No further mechanical pulse damping is required. Delivery of mobile phase in the range 0.2 2.5mL per minute, the usually used range, is well within the ability of the pump, which delivers in the range 0.001mL/min to 10mL/min. The Total I C Concept Dual overlapping piston pump Microprocessor control for low pulsing Chemically inert flow-path Precisely thermostatted cell Low dispersion heat exchanger Dual column oven Leak detection The wetted components of the pump are, sapphire, ruby and ceramic inserts. PowerStream data processing PowerStream system control In line vacuum degassing Regenerative chemical suppression IC using UV detector Suppressor cartridge in oven Modular flexibility Convenient Column Oven It is important that the separation columns should operate at a constant temperature, matching the temperature of the measuring cell. The CE4601C column oven module is a very convenient front opening design accommodating two analytical columns and precolumns and also, when needed, a mobile phase background conductivity suppressor cartridge and its over-pressure protection valve. The oven operates over the range from ambient temperature +5ºC to 85ºC. The default temperature is set at 35ºC. The actual and set temperatures are displayed by a bright LCD display and may be controlled by the adjacent keypad, or set by the PowerStream software. Temperature stability is better than ±0.01ºC. The flow tubes from the columns and suppressor cartridge enter and leave the oven enclosure through convenient self-sealing ports. The output port to the cell thermostatted enclosure lines up with the input connector of the enclosure, when the modular system is arranged as shown in the photographs of the system. The very close coupling to the detector cell leaves only about 2 centimetres of tube between the oven and the cell. With the cell and oven operated at the same temperature, say 35ºC, drift or noise due to ambient fluctuations is eliminated. A column switching valve may be fitted to the oven offering convenient operation. 4

BY POWERSTREAM SOFTWARE PowerStream The Powerful Software All the data processing procedures and power you need are elegantly available in PowerStream software. Digital system control is also available. A typical display is shown here of a waste water cation analysis with a superimposed portion of the chromatogram highlighting sodium. Detail and clarity are excellent and the software is truly both easy to use and sophisticated. A fully interactive graphical interface provides for full method development, data capture and display of chromatograms for live screen display during a run. Developed to operate with Windows XP and VISTA, it may also be used with Windows 2000. PowerStream Features Digital and analogue outputs Process signals from multiple detectors Comprehensive integration parameters Calibration curves with unlimited number of standards Linear, Quadratic and Cubic calibration curves Chromatogram overlays Bracketing of samples Digital control of a range of peripherals 5

FAST ACCURATE ANALYSES S Anions in Drinking Water The Anion Suppressor was used Column:- Allsep Anion 100 x 4.6mm Mobile Phase:- 0.85 mmol/l NaHCO 3 0.90 mmol/l Na 2 CO 3 Flow Rate:- 1.2mL/min Injection Volume:- 20 µl Column Temperature:- 35ºC Detector Temperature:- 35ºC Retention Time Anion Measured (mm : ss) concentration (ppm) 02:27 Unknown - 03:49 Chloride - 04:57 Unknown - 07:57 Nitrate 37 12:13 Phosphate - 14:01 Sulphate - Some Applications Drinking, surface and waste water Sulphites in wine Phosphoric and citric acids in soft drinks Organic acids in water Bromide in water Nucleic acids Fatty acids and hydroxy fatty acids Amino acids Dicarboxylic acids Amino acids Weak organic acids Sodium in foods Metals in soil Azide and cyanate in explosives Alkali metals and alkaline earths in grain Chromate and sulphate in electro plating Inorganic Cations in Effluent Water Column:- Universal Cation 7 µm 100 x 4.6mm Mobile Phase:- 5mmol Methanesulfonic acid Flow Rate:- 1.5 ml/min Injection Volume:- 20 µl Column and Detector Temperatures:- 35ºC Retention Cation Measured Time concentration (mm : ss) (ppm) 01:54 Na + 72.03 02:04 NH + 4 29.39 02:34 K + 36.30 03:38 Mg 2+ 6.47 4:17 Ca 2+ 106.56 6

WITH HIGH SENSITIVITY Phosphoric Acid in Soft Drinks The established method for determination of Phosphoric Acid in cola beverages uses the molybdenum blue analysis. This spectrophotometric method is not however rapid. An Ion Chromatography method was developed, in our applications laboratory, which is both rapid and accurate. The Cecil CE4715 suppressor was used to reduce background conductivity. This improved sensitivity with reduced noise and drift. The reduction was from about 500µS/cm to 20µS/cm. The flow rate of the eluent: 2 mm Na 2 CO 3 / NaHCO 3 buffer, was 1.3mL/min with a 7 micron anion column. The determination of Phosphoric acid in a cola drink, as shown here, required under 5 minutes using a flow rate of 1.3mL/min. The column oven and cell were both at 45ºC. Versatility The modular design of the system leads to complete versatility through interchange of modules. For methods requiring the use of a UV/Visible detector, the conductivity detector is easily replaced by the CE4300 variable wavelength detector, or the fast scanning DAD WaveQuest detector as shown in the photograph. 7

SPECIFICATIONS Conductivity Detector CE4710 Conductance Display Range 0.01 5000µS/cm Output Signal Selectable for anions or cations Time Constant 0.1, 0.2, 0.5, 1, 1.5, 2, 5s Autozero Range Typically up to 10,000µS/cm Synchronous Detection Frequency 5kHz Noise Less than ±1nS/cm, DI water, 1mL/min, 2s Drift Less than 20nS/cm/h, DI water, 1mL/min, Cell Volume 0.5µL Cell Body PEEK P1000 grade Electrodes 316 stainless steel Cell Pressure Rating 200psi Cell Enclosure Heater 20 watt Operating Temperature 25 50ºC; 35ºC standard Temperature Precision ± 0.01ºC Warm-up Time 10 minutes typical LCD Screen 4 lines, back lit, adjustable contrast Method Storage Up to 100 with password protection Analogue Output 0-1V Computer Interface RS232 Remote Autozero By contact closure Digital Control By PowerStream software Keypad Control For entry of values, commands and programmes Pump CE4100 Pump Type Dual piston design Flow Rate 0.001 to 10mL/min in 0.001 steps Flow Reproducibility Better than 0.1% Maximum Pressure 40MPa 400 bar User Interface 4 line back-lit display and full range of keys Pressure Cut-outs Adjustable for over and low pressures Pulsation Better than ±0.5% at 2mL/min Flow Path Materials Ceramic, ruby, sapphire, PEEK Column Oven Number of Columns 2 plus suppressor cartridge Pressure Cut-out Valve Accommodated Option Temperature range Ambient +5ºC to 85ºC Temperature Stability ±0.01ºC Temperature Display 3 digit LCD display Injection Valve Rheodyne Valve PEEK flowpath, 100mL loop ORDERING IonQuest System 1: CE 4100 pump, CE 4710 conductivity detector, conductivity flow cell, CE 4601c column oven, CE 4033 solvent bottle and flow pipe co-ordinator, rheodyne injector valve with 100µL loop and mounting bracket, CE 4900 PowerStream software and system controller, 4150 05 00 installation kit, interconnecting leads, power cable and operators manual. IonQuest System 2 As System 1 plus CE 4020 inline degasser and tubing with connectors. Optional Items CE 4715 Suppressor system for Anion background suppression 4720 01 01 Overpressure valve to protect suppressor cartridge CE 4020 Solvent degasser 2 channel CE 4800 Auto-sampler with valve Analytical Columns 4100 60 06 Strong Anions 7µm 4100 60 09 Strong Cations 7µm 4100 60 10 Weak Anions 3µm 4100 60 11 Weak Cations 3µm Guard Columns 4100 59 06 Strong Anions 7µm 4100 59 09 Strong Cations 7µm 4100 59 10 Weak Anions 3µm 4100 59 11 Weak Cations 3µm Workstation Computer System Solvent Degasser Degasser Optional Number of Flow Paths Flow Path Material System Details Power Requirements Total Stack Size In-line degasser Two, up to 3 ml/min each PTFE, PEEK 110V or 240V, 50/60Hz, 200VA 365 x 290 x 470mm (WDH) PC with Pentium class processor Pentium 1 GHz or higher Microsoft Windows XP or Vista RAM 512 MB or higher Hard disk space 150 MB CD-ROM drive XGA or higher resolution monitor monitor resolution 1024 x 768 or better Mouse or compatible pointing device Free RS232 serial connection or serial to USB convertor Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice. CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB24 6AZ ENGLAND TEL: 01223 420821 FAX: 01223 420475 E-MAIL: info@cecilinstruments.com Email: www.cecilinstruments.com ISO 9001 : 2000 CERTIFIED COMPANY 8