DESIGN GUIDELINES AND TECHNICAL STANDARDS

Similar documents
DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DOMESTIC WATER PACKAGED BOOSTER PUMPS

DUKE UNIVERSITY CONSTRUCTION STANDARDS

2. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.

2016 Plumbing Supplemental Plan Review List

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

SECTION DOMESTIC WATER PIPING SPECIALTIES

GARCIA GALUSKA DESOUSA Consulting Engineers

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DIVISION 22: PLUMBING DESIGN STANDARDS TABLE OF CONTENTS

Sanitary Drainage Systems

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

DESIGN CRITERIA See Part II for additional information regarding Energy and Water Efficiency, etc.

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. This Section includes the following domestic water piping specialties:

Yale University Design Standards

BSD Technical Standard. Division 22: Plumbing

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

GENERAL PLUMBING REQUIREMENTS

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

GENERAL PLUMBING REQUIREMENTS

2009 IPC ,IMC Q &A ANDIFGC

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Matrix of changes for the National Standard Plumbing Code July 2013

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

Automatic Temperature Controller (ATC)

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

A. Section Joint Sealants: Seal fixtures to walls and floors.

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

PLUMBING REQUIREMENTS

Special Requirements For Health Care Facilities

Mechanical Inspection Plumbing

4. Provide brass valve tags marked for the service. See pertinent service specification for valve type.

B. Provide unique numbers for all applicable equipment, valves, and similar.

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Mechanical System Description

DESIGN AND CONSTRUCTION STANDARDS July 2011

COMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

TABLE OF CONTENTS DIVISION 22 - MECHANICAL

University of Rochester October 17, 2008 Brooks Landing Business Center

DOCUMENT TABLE OF CONTENTS

Pipe Sizing Table. Hydraulic Load Served (fixture units)

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

NYC Department of Education

NYC Department of Education

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

Plumbing and Drainage

SECTION PLUMBING

Building Utilities 1 Plumbing and Sanitary Systems

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

NYC Department of Education

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

APPENDIX A. A 3.2 Determine the elevation of the highest. A 3.3 Subtract the sum of loss in static pressure

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

A. This Section includes the following emergency plumbing fixtures:

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

MATERIALS Traps TRAPS. No. IPC IRC Description

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

SECTION ELECTRIC WATER HEATERS

University of New Hampshire Scholars' Repository

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

SECTION PLUMBING FIXTURES

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

NYC Department of Education

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

FEATURES. Other Fed-Flush Arrangements

PRICE BOOK CONTENTS 010 PIPE

NYC Department of Education

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION SECTION DESIGN REQUIREMENTS

NYC Department of Education

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

NYC Department of Education

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - EQUIPMENT

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX A - RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM 1 2 1/AC AC SS SS/CC

NYC Department of Education

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

Read Only Document Not For Distribution

DUKE UNIVERSITY DESIGN GUIDELINES

1 Exam Prep Plumbing State Contractors Practice Exam 2

PLAN REVIEW SUBMITTAL GUIDE

Mechanical/Plumbing Specification

NYC Department of Education

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

Transcription:

DESIGN GUIDELINES AND TECHNICAL STANDARDS Date of Issuance: January 1, 2014

DIVISION 22 PLUMBING SECTION 22 1118 DOMESTIC WATER DISTRIBUTION SYSTEM 1. General: This section outlines general requirements for domestic water distribution systems. 2. Design Considerations: 3. Materials: a. Potable water pipe shall be routed so that the circuit terminates at high use areas, such as washrooms. The purpose is to avoid stagnation leading to a high bacteria count. b. Piping shall be routed orthogonally (no diagonal shortcuts). c. Domestic cold water, domestic hot water supply and recirculation, laboratory cold water, laboratory hot water and recirculation, and fill/makeup water lines shall be copper. d. Faucets and fixtures, such as emergency showers, eye wash, dishwashers, and autoclaves shall have local shutoff valves within five feet of the faucet/fixture. Valves must be accessible. e. No piping with a fluid shall be routed over electrical busway housings. For electrical busway housings provide a minimum 24 inches on top, both sides and the bottom. f. An excellent table giving the chemical resistance of four commonly used thermoplastic piping materials can be found in the Technical Manual published by the Charlotte Pipe and Foundry Company, Industrial Division (800-438-6091). g. In lab buildings, consider a redundant distribution system such as a pair of risers cross connected at the floors. a. Steel and copper pipe shall be built and stamped to meet ASTM standards. b. Copper Tubing: i. Copper tubing shall be type L hard drawn. ii. Copper tubing shall be 95-5 soldered. Solder shall be lead free. iii. Grooved copper tubing is not permitted. c. Galvanized pipe is not permitted. DOMESTIC WATER DISTRIBUTION SYSTEM 22 1118-1

d. Laboratory Drain and Vent Piping: i. General: 1. Joints shall be mechanical. Beading, fusing caulking, or welding of joints is not acceptable. 2. Review requirements for neutralizing basins. ii. Material: PP (polypropylene). iii. Acceptable Manufactures for Polypropylene: 1. Enfield Industrial Corp. END OF SECTION DOMESTIC WATER DISTRIBUTION SYSTEM 22 1118-2

DIVISION 22 PLUMBING SECTION 22 2114 PLUMBING SPECIALTIES 1. General: this section outlines general requirements for plumbing specialties. 2. Materials: a. Ball Valves: i. Ball valves shall be bronze, 600 psig WOG, full port, with a 316 stainless steel ball and stem. ii. Insulated valves shall have a 2-1/4 in. stem extension. iii. Acceptable Manufacturers: b. Gate Valves: 1. Conbraco Industries, Inc. (APOLLO) 2. Neles-Jamesbury, Inc. 3. Watts Regulator Co. i. Gate valves are not permitted. c. Backflow Preventers: d. P-Traps: END OF SECTION i. Backflow preventers shall be by the Watts Regulator Company, Series 909. 1. Exception: Fire Protection Systems. i. Trim P-traps and accessories shall be 17 gauge minimum. PLUMBING SPECIALTIES 22 2114-1

This page intentionally left blank PLUMBING SPECIALTIES 22 2114-2

DIVISION 22 PLUMBING SECTION 22 4000 PLUMBING FIXTURES 1. General: This section outlines general requirements for plumbing fixtures. 2. Design Considerations: 3. Materials: a. When possible sinks, urinals and closets should match existing fixtures for renovation projects. b. Review project specific requirements with NU Project Manager. a. Sinks, Urinals, and Closets: i. Acceptable Manufacturers: 1. American Standard, Inc. 2. Crane Company. 3. Eljer Plumbingware. 4. Kohler Company. b. Faucets, Except Laboratories: i. Electronic eye faucets are preferred in public washrooms. The transformer shall be hard wired. Spring loaded non-electric faucets are not acceptable. ii. Coordinate power requirements and indicate on electrical power drawings. iii. Acceptable Manufacturers: 1. The Chicago Faucet Company. 2. Kohler. 3. Sloan Valve Company. c. Laboratory Faucets and Hardware: i. Laboratory, eyewash and shower faucets, vacuum breakers, and appurtenances shall be furnished by The Chicago Faucet Company. PLUMBING FIXTURES 22 4000-1

d. Urinal Flush Valves: i. Acceptable Manufacturer: 1. Sloan Valve Company, Model 8186-1 (1.0 gpf). e. Water Closet Flush Valves: i. Toilet flush valves shall have a transformer and shall be hard wired with a courtesy flush override button. Coordinate power requirements and indicate on electrical power drawings. 1. Exception: Tank-type toilets. ii. Acceptable Products: 1. Chicago and Evanston campus: 111ES-S (1.6 gpf) iii. Acceptable Manufacturers: f. Drinking Fountains: 1. Sloan Valve Company. i. Design Considerations: 1. Provide dual-height drinking fountains with bottle fillers. 2. Coordinate power requirements and indicate on electrical power drawings. ii. Acceptable Manufacturers: g. Hand Dryers: 1. Halsey Taylor. a. Basis-of-Design Product: HAC Hydro-Boost, barrier-free, Model HTHB-HAC8BL-WF. 2. Elkay Mfg. Co. i. Northwestern prefers paper towels over electric hand dryers. Review specific requirements with NU Project Manager. ii. If provided, hand dryers shall be surface mounted equipped with an infrared sensor and an automatic 60 second cut-off switch, 120 Vac. Coordinate power requirements and indicate on electrical power drawings. PLUMBING FIXTURES 22 4000-2

END OF SECTION iii. Acceptable Manufacturer: 1. Sloan Valve Company, Model EHD-401. PLUMBING FIXTURES 22 4000-3

This page intentionally left blank PLUMBING FIXTURES 22 4000-4

DIVISION 22 PLUMBING SECTION 22 4500 PLUMBING EQUIPMENT 1. General: This section outlines general requirements for plumbing equipment. 2. Materials: END OF SECTION a. Domestic Water Booster System: i. No encased (can type) pumps are permitted. ii. Above 10 hp domestic water booster pumps shall be variable speed. iii. Acceptable Manufacturers: 1. Metropolitan Industries, Inc. b. Sump and Ejector Pumps: i. Acceptable Manufacturers: 1. Metropolitan Industries, Inc. 2. Hydro O Matic Pumps, A Division of Wylain, Inc. 3. No submersible sump pumps are permitted, except in elevator shafts. PLUMBING EQUIPMENT 22 4500-1

This page intentionally left blank PLUMBING EQUIPMENT 22 4500-2