Design Guidelines Fire Safety in New and Refurbished Buildings

Similar documents
UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

GENERAL FIRE SAFETY TERMS & DEFINITIONS

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY

Fire Enforcement Report

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

- CONSTRUCTION FIRE SAFETY STANDARDS

EMERGENCY EVACUATION PLAN

UK Direction BS7671 BS 8492 BS /01/2018

Fire Alarm Control Panel. System Maintenance and Log Book

BUILDING FIRE STRATEGY (Operational & Fire Engineering Information)

Unit 2 Fire Safety (Zone 1)

Element C3.5 Means of Escape

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

Areas of the building to which access was not available. Details of any onsite management (if known)

FIRE RISK ASSESSMENT

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK. Regulatory Reform (Fire Safety) Order 2005 DARWIN BUILDING

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

Northern Ireland HMO Fire Safety Guide

Fire safety procedure

Building Construction i. approx. age ii. building structure iii. cladding iv. floors v. walls vi. roof

Agency for Health Care Administration

BUILDING FIRE STRATEGY

- CONSTRUCTION FIRE SAFETY STANDARDS

Agency for Health Care Administration

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

A Guide To BS Understanding the selection, spacing and siting of detectors

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

PREMISES FIRE SAFETY HANDBOOK

LIFE SAFETY CODE ESSENTIALS PRESENTED BY: LARRY VIGIL, RISK CONSULTANT

Agency for Health Care Administration

fire risk assessment For use by landlords of small premises Premises Address

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

PREMISES FIRE SAFETY HANDBOOK

Fire Risk Assessment Guidance

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Fire Safety Management

Fire detection and alarm

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Fire Risk Assessment

3.1 Introduction. 3.1 Introduction

University of London

Design of Fire safety in Multi Occupancy Residential Accommodation

FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation

Understanding Passive Fire Protection

Fire Procedures. April 2016

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006)

CURTIN UNIVERSITY PROJECT DELIVERY GUIDELINES

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Passive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Fire Safety Management Plan. Qube 90, Whitfield Street, W1T 4EZ. Fire Safety Management Plan & Evacuation Procedures

Case Study 1 Underground Car Park

Fire precautions in dwellings

IDD 033C - Fire door sets

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house

FIRE RISK ASSESSMENT MATHEMATICS BUILDING (INCLUDING OLD OCEANOGRAPHY BUILDING)

EMERGENCY EVACUATION PLAN

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

Fire Safety Protocol

Policy for Safe Evacuation of Persons with Disabilities

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

Fire Safety Risk Assessment Large Premises

1.4 Provide and fix the following ironmongery.

Fire Design Guide. Introduction Scope Aims Consultation Design Strategy Compartmentation Provision...

Fire Risk Assessment

BUILDING FIRE STRATEGY

Passive Fire Protection Guidance. Niall Rowan Technical Officer Association for Specialist Fire Protection

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

Guidance for writing a Personal Emergency Evacuation Plan (PEEP)

Duties and Responsibilities of Fire Marshals

The Mungo Foundation. Fire Safety Policy and Procedure

Fire Risk Assessment

CHAPTER 5 - STRUCTURAL FIRE PRECAUTIONS

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

Reviewed: DD Month Emergency Evacuation of People with a Disability Options Matrix for Developing a PEEP

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Fire Safety Design Guide

Fire Risk Assessment Borough High Street

Charlotte Building, 17 Gresse Street, London W1T 1QL

NOTTINGHAM CITY HOMES

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

Fire Risk Assessment Guide

Fire Safety Policy 2018/19

Fire Risk Assessment. A safety guide for users of the hall

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

London Borough of Hammersmith & Fulham

GDST Fire Safety Strategy March 2016

PREMISES FIRE SAFETY HANDBOOK

RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

Certification Assessment Instrument and Guidelines

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

Transcription:

Design Guidelines Fire Safety in New and Refurbished Buildings Introduction All major new or refurbishment projects must comply with the Technical Standards (Scotland) Regulations as a matter of course. There are however, a number of areas where the University wishes to make provisions above and beyond the minimum requirements in the Technical Standards or make additional improvements to existing buildings where upgrades to meet the Standards are not strictly required as part of a Building Warrant application (e.g. situations where the status quo is deemed to comply). These improved provisions are normally required to comply with Risk Assessments carried out by the University Fire Safety Adviser as required under the Fire (Scotland) Regulations 2006 It will be necessary on every new build or major replacement project to meet with the University Fire Safety Adviser and a representative from Estates and Buildings to review existing fire risk assessments and/or agree any provisions that go beyond the requirements of the Technical Standards. The guidelines listed in this document provide guidance on existing fire strategies and lists typical areas for consideration. Plan Drawings Plan drawings covering the layout of the building, compartmentation and intended fire warning system schematics should be submitted for comment at the earliest opportunity. Considerations for Means of Escape Dead end conditions existing on plan or in buildings should be considered as this may reflect on the fire safety measures required to protect the occupiers of these areas. It may include upgrading, to a suitable resistance, walls, door, glazing etc or may have an influence on the category of fire warning system required. Provision of smoke stopping doors in corridors to reduce the spread of combustion products is generally met by the Technical Standards; however, in some circumstances do not always provide the practical solution. In some cases, large rooms, i.e. seminar or lecture rooms where occupant capacity exceeds 60 persons, should be considered for alternative means of escape where technical standard applied is angle Created on 14/04/2010 Page 1 of 5

of divergence and thus does not provide a practical solution because of distance to final exit or discharge into one inappropriate route on corridor. Where final exit from a building is via an external route the route should be constructed of non-slippery hard standing and illuminated throughout its length. Where final exit from a building is via and external staircase the staircase should be afforded appropriate fire protection to allow the occupier to use the staircase in event of fire. The staircase should also be illuminated throughout its length. Protected lobbies onto staircases are required in certain circumstances by the Technical Standards; however, there may be other occasions when it may be appropriate to consider such lobbies, in single staircase conditions when no provision is required, or to assist with disabled evacuation procedures, or afford protection to lifts, or reference to number of storeys. This may also have an influence on the category of fire warning system required. Where rooms do not open directly onto a corridor or escape route (e.g. room accessed from another room). Ironmongery fitted to doors should not be of a type whereby occupiers can be inadvertently locked in the rooms. Doors should be easily and immediately openable from the inside without the use of keys e.g. turnbuckle. There will be circumstances where security is an issue and this should also be considered independently but not be a hindrance to escape in event of fire. Self-closing devices fitted to doors should not be of a type that will permit occupiers of buildings to tamper with the devices thus rendering them ineffective. Self closers should also be delayed action type in all circulation areas to improve disabled access. Places of public assembly should have push bar to open mechanisms on emergency exit doors. Push pads are only permitted on staff area doors. Passive Fire Protection (P.F.P.) Fire separation within a compartment should be considered and the following direction recommended if considered necessary. This may also have an influence on the category of fire warning system required Corridor walls should be continuous from floor to structural soffit. If construction involves flexible partitioning then cavity barriers or fire curtains should follow the line of the corridor walls. Subdivision of the ceiling and floor voids by fire curtain should be considered. Created on 14/04/2010 Page 2 of 5

All Services penetrations including power cable or data cable penetration through corridor and compartment walls or floors should be suitably fire stopped with appropriate materials on both sides of the wall or floor. The booklet Ensuring Best Practice for Passive Fire Protection in Buildings should be referred to for guidance on all items concerning P.F.P. Provision for the Disabled Consideration should be given to including the designation of specific temporary waiting areas in buildings which will allow disabled people to use and be evacuated from University Buildings whether or not this is a requirement as part of the Building Warrant. Deaf Alerter should be installed. Consideration should be given to the provision of a fixed communication system and its location with regard to temporary waiting areas for disabled people and appropriate communication panels next to the fire alarm panel. In multi-storey buildings provision of appropriate lifts that will permit disabled person evacuation in event of fire should be considered. All the above items will have an influence on the category of fire warning system required. Automatic Fire Detection and Fire Warning System Categories of Fire Alarm installation are defined in British Standard 5839 Part1: 2002. In determining which category should be employed three main factors must be considered. The protection of Life The protection of property The protection of business against interruption to its operation. These three factors form the essential part of the Risk Assessment process and to ensure compliance the following items must be considered in determining the category of alarm system required. Use of the building Means of Escape Created on 14/04/2010 Page 3 of 5

Procedures for disabled persons Construction of the building Fire compartmentation Fire separation within the compartment Passive fire resistance Residual Hazards or Fire Risks within the building Special provisions required for protection of equipment Special provisions for the protection of heritage, listed buildings etc Management of the building and working practices. Site specific evacuation procedures After consideration of the factors and items indicated above the category of fire Alarm for installation in the building will be confirmed. As an example residencies would always have a category minimum of L2 whereas other University buildings could fall into any of the other categories specified in BS 5839:Part1; 2002 Other points for consideration 1. Whether full or phased evacuation required. 2. Additional requirements of Fire Alarm panel. 3. Requirements for plant, ventilation, lift etc. 4. Limitation of false alarms. 5. Additional requirements for disabled persons. e.g. communication device, no sounders in temporary waiting areas or near fire and communication panels. 6. Provision of a telephone adjacent to Fire alarm panel 7. Location and use of magnetic devices Strobe or beacons should be considered as an addition or replacement for sounders in the following locations: -- i. Large Seminar Rooms ii. iii. iv. Lecture Rooms All Toilets Plant and Machinery Rooms v. Places of Public Assembly vi. vii. Libraries Theatre Auditoriums Created on 14/04/2010 Page 4 of 5

viii. Staircases used as temporary waiting areas for disabled persons Before acceptance of the installed alarm system the appropriate certification for design, installation, commissioning and acceptance must be provided together with the documentation as required by the British Standard. Commissioning During the commissioning process all system must be demonstrated and accepted by Estates and the FSU. The occupiers should also be instructed in the daily and weekly testing regimes and appropriate certificates produced. General The provision of all fire exit signage luminous units or pictorial signs should be considered. Storey or final exits should always be illuminated. Emergency lighting must always be provided. The standard being: Maintained in Places of general assembly and residencies: Non Maintained in other areas The provision of all firefighting equipment should be considered and probable costs estimated. Created on 14/04/2010 Page 5 of 5