CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Similar documents
REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS Serial No.:

REIMERS ELECTRA STEAM, INC. CAUTION:

Serial No.: and Up OPERATING INSTRUCTIONS MODEL AR. STEAM GENERATORS CAUTIONS:

Electra Steam, Inc. RLP 100k 500kW Low Pressure and RHP 100kW 500kW High Pressure Steam Boiler Models. Instructions Manual

R- RH- and RHC-Steam Boiler Models (RB-Series) Serial No and up

Instructions Manual. RHP120 RHP300 High Pressure Steam Boiler Models MODEL: Electra Steam, Inc. SERIAL #:

RX Series Steam Boiler Instructions Manual

REIMERS ELECTRA STEAM, INC MARTINSBURG PIKE CLEAR BROOK, VA PHONE: FAX: /17/2000

R- RH- and RHC-Steam Boiler Models (RB-Series)

MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS

MODELS R & RH 24 THRU 120 ELECTRIC STEAM BOILERS

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

ERGOMAX 7 INSTALLATION

RHP120 RHP300 Steam Boiler Series

Operating & Safety Instructions

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

REMOTE FAUCET PUMP SYSTEM

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Spa Control System OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

OWNER'S MANUAL RSL MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local:

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

InstructIon Manual KrEs EQuIPMEnt stands


EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Pressurized Filter Up to 1250 gallons

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TRANQUILITY ADVANCED HEATING SYSTEM

52 SAN LUCAS CEILING FAN

Stand Fan. English. Owner s Guide. Model F R

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

LIMITED LIFETIME WARRANTY

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Instruction Manual. Double Candy Apple Cooker

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Unpacking Your Fan 2.

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Installation and Maintenance "L" and "LS" Series

INSTALLATION, OPERATION AND MAINTENANCE

52 BAYTOWNE CEILING FAN

OPERATING MANUAL/ INSTALLATION

Air Pump Up to 800 gallons

Instruction Manual. Bucket Oil Pump

OPERATIONS MAINTENANCE MANUAL

METS MODEL E-106. (115 VAC, 60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE

B.I.C.A Built-In Coffee Appliance

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE

TITAN FLOW CONTROL, INC.

e Heater/Exhaust Fan/Light User s Guide

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

Installation Instructions / Warranty. Massaud

Owner's Manual Paramount 65X GRAPHIC LAMINATION PRODUCTS

e Bath Fan with Light User s Guide

USER S OPERATING AND INSTRUCTION MANUAL

OWNER'S MANUAL T0140. Contents Page #

WATER POWERED OSCILLATING MONITOR

LIMITED LIFETIME WARRANTY

Garment Steamer Model SC620

INSTALLATION ADJUSTMENT SERVICE

HANDHELD STEAM SCRUBBER S3401 OWNER S GUIDE

METS MODEL E-112. (115 VAC, 50/60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE TABLE OF CONTENTS

Eco-Steamer SSC-0312 INSTRUCTION MANUAL CONTENTS

Wilbur Curtis Company, Inc. Service Manual WB-10 Water Boiler

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

With Remote Control. English. Model

Panel Mounted Heat Exchangers by Dantherm, Inc.

LIMITED LIFETIME WARRANTY

P/N CC-100. Coolant Circulator. Operation manual

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

52 BARSTOW CEILING FAN

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

Camarillo 52 Ceiling Fan

MaxLite LED High Bay Fixtures

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

e Bath Fan with Light User s Guide

TA-300, TA-300-LF, TA-350, TA-350-LF

52 STRATHMERE CEILING FAN

All about the Use &Care

EXTRACTOR Operation & Maintenance Manual

LIMITED LIFETIME WARRANTY

LIMITED LIFETIME WARRANTY

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping

48 TAYLOR CEILING FAN

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

The Da-Lite Difference.

Transcription:

ASME CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models RETAIN THIS OPERATING MANUAL WITH BOILER. DO NOT DISCARD READ THIS FIRST: The safeguards and instructions appearing on these pages are not meant to cover all possible situations that may occur. Understand that common sense, caution, and care are factors which cannot be built into any product. The person operating the unit must supply these factors. Read all instructions before installation and operation. Ensure that the blowdown valve is properly and safely piped. Do not position your face or body over the fill funnel. Stand clear of safety valve and scalding steam. Never open the fill valve when unit is under pressure. Valves and pipes are hot when under pressure or heating up. Do not touch! IF A LEAK IS EVIDENT: Steam fittings can become loose during shipment and subsequently leak. It is easy to resolve these leaks if you are careful: Steam Jet Pipe Front Orientation 9 11 2 1 Steam Jet Pipe Side Orientation ASME Plate behind this panel 1. General 1. Ensure that the boiler is cold, drained and has no pressure or electricity. 2. Tighten leaking packing nut gently a quarter of a turn. Do not over tighten, as this will result in gauge glass breakage or in valve stem freezing and valve failure. 3. Fill boiler and operate normally. 4. Observe for more leaks and repeat steps 1 and 2 as required. The Reimers JR-series boiler is a portable, hand-filled steam generator with a total of 2 gallon capacity, for operation at pressures from 5 to 85 psi. Designed to the ASME/CSD-1 Boiler Code and registered with the National Board of Boiler Inspectors, it is safe when installed, maintained, and used properly. Standard JG-Model equipment includes: Steam pressure gauge (1), steam valve (2), blowdown valve (3), water-fill funnel (4), check valve (5), water fill valve (6) safety valve (7), water level gauge (8), electronic boiler control (9) and power cord (10). JJ-Model equipment includes in addition to standard model equipment: Steam jet with electric solenoid valve (11) and foot switch (12). Adjustments: All controls have been set at the factory and should require no adjustments (Open gauge glass valves). Modification/Misuse: Any modification or misuse of this unit could result in a dangerous situation. Reimers Electra Steam, Inc. is not liable for any product that has been modified or improperly used. Registration: Most states and cities require boiler registration/inspection. Check with local government authorities. Repair: Only experienced personnel must attempt repair of this unit. For repair instructions see chapter 5 of this instruction manual. 10 JJ-Model shown 7 3 4 5 6 8 12 Electra Steam, Inc. 4407 Martinsburg Pike Clear Brook, VA 22624 USA Phone: 540-662-3811 Fax: 540-665-8101 Email: Sales@reimersinc.com Web: www.reimersinc.com

LIMITED WARRANTY - STEAM GENERATORS Reimers Electra Steam, Inc. warrants the following products of its own manufacture against defects in materials and workmanship under normal use and service. This warranty is in lieu of and excludes all other expressed or implied warranties or merchantability of fitness for any particular use. No person is authorized to extend the terms of this warranty or assume any other liability except by written statement signed by an officer of Reimers Electra Steam, Inc. Clear Brook, Virginia 22624. WARRANTY PERIOD The pressure vessel, as well as the electrical and mechanical components is warranted for one year from date of shipment from Reimers Electra Steam, Inc., Clear Brook, VA 22624. LIMITATIONS Products must be installed, used and maintained in accordance with our instructions, including reasonable and necessary maintenance by the user. Users are responsible for the suitability of the products to their application. There is no warranty for damage resulting from improper installation, abuse, power failure, fire, flood, lightening, improper water, misuse, improper specification, misapplication or other operating conditions beyond our control or parts that are normally expendable in usual course of operation. Claims against carriers for damage in transit must be filed by the buyer. Reimers liability, if any, will not exceed the price of Reimers products claimed to be defective. Components manufactured by any supplier other than Reimers shall bear only that warranty made by the manufacturer of that product and service for that warranty shall be the responsibility of that manufacturer and not Reimers. REMEDY Claims under this Limited Warranty must be made by obtaining a Return Authorization Number from our office (PHONE: 540-662-3811, FAX: 540-665-8101) and returning the defective part, freight prepaid to: Reimers Electra Steam, Inc., 4407 Martinsburg Pike, Clear Brook, Virginia 22624. Defective items will be repaired or replaced as necessary within a reasonable time without charge, other than incidental charges such as freight prepayment. Such repair or replacement within a reasonable time is the exclusive remedy available from Reimers Electra Steam, Inc., under this Limited Warranty. CONSEQUENTIAL DAMAGES Reimers Electra Steam, Inc., is not liable for labor costs incurred in the removal, reinstallation, or unauthorized repair of the product, or for damages of any type whatsoever, including incidental and/or consequential damages. THIS WARRANTY SUPERSEDES ALL PREVIOUS WARRANTIES.

2. Installation Pipe Installation: Steam piping must be of black pipe, not galvanized. Work must be performed by an experienced steamfitter. All state and local codes must be met. Electrical: All wiring must be in accordance with the National Electric Code and any local codes that may apply. Wiring must be done by a competent, certified electrician. Use only copper wire. Water: Ensure that all electrical components are in a dry location not subject to steam or water. Blowdown Valve: When the blowdown valve is utilized, a large volume of hot water and steam is discharged. Ensure that this valve is properly piped for this discharge. State and local codes must be met as applicable. Safety Valve: Safety valve is designed to discharge hot steam when the set pressure is exceeded. Ensure that the discharge port is pointing toward the back of the unit away from the operator and any aisles. 3. Operation CAUTION! Do not position your face over the fill funnel. Never open the fill valve when unit is under pressure. 1. Close blowdown valve (3). 2. Connect electric cord to grounded 120-Volt outlet. 3. On the electronic boiler control (9), turn on the power switch (16). 4. Open fill valve (6) and release air from unit by opening steam valve (2). On JJ-models: Release air by pressing foot switch with power switch of electronic boiler control (9) on. 5. Pour water into funnel (4) until it reaches the "Max. level mark beside the gauge glass. Do not overfill. Close fill valve (6). NOTE: Overfilling will cause dirt and rust to be carried into the steam lines and onto goods. It will also cause the steam release valve to leak. Use tap water only! 6. On the electronic boiler control (9): Push the Low Water manual reset switch (15). The Heating light (14) will stay on until the preset working pressure is reached. 7. When the water level gets low, the unit will shut off automatically and the Low Water alarm light (15) will be lit. To refill, turn off the power switch (16) and allow the steam pressure to drop to zero. 8. Refill the boiler by repeating this procedure. 4. Maintenance CAUTION! Maintenance and repair must be performed by experienced personnel. Before maintenance or repair, ensure that the boiler is cold, drained and has no pressure or electricity. All electrical and steam safety precautions must be taken. Leaks on the gauge glass fixtures: The two brass nuts at the top and bottom of gauge glass (8) should be tightened until leakage stops. Follow instructions on page 1 of this manual. (Note: Gauge glass valves should be open all the time) Replace the Gauge Glass (8): Replace the gauge glass minimum once per year. CAUTION! Ensure that the boiler is cold, drained and has no pressure or electricity. Be careful not to break the glass. 1. Close gauge glass valves (top and bottom). 2. Open petcock on bottom fixture to drain glass. 3. Loosen nuts at top and bottom of glass. 4. Slide glass up, pull out on bottom of glass and remove. If removing of glass is not possible, then it may be necessary to rotate either the bottom valve or both valves 1/8th of a turn. 5. Install glass by reversing above procedure. NOTE: Always install new rubber washers. Blowdown: Perform boiler blowdown minimum once per week. CAUTION! Stand clear of scalding water and steam. Before opening the blowdown valve, ensure that it is properly piped in accordance with state and local codes. Turn the power switch (16) off and allow steam pressure to drop to 5 psig. Then open the blowdown valve (3). Adjust Steam Pressure (22): This control is factory preset, and usually does not require adjustment. CAUTION! Stand clear of safety valve and scalding steam. 1. Disconnect the power cord plug from the wall outlet. 2. Remove the cabinet side cover to gain access to the operating pressure control. CAUTION! Do not adjust the pressure high-limit control (23) marked DO NOT ADJUST. This control is factory preset for safety purposes. 3. Adjust pressure by turning the black adjustment knob. Test the Safety Valve (7): Test this valve once per month. CAUTION! Stand clear of safety valve and scalding steam. Before testing the safety valve, ensure that it is properly piped in accordance with state and local codes. NOTE: Safety valve should be tested at full operating pressure. If discharge pipe is required, it should not be smaller than valve outlet and must be rigidly supported. 1. Hold trip lever open for 5 sec. in order to flush off valve seat. 2. Permit valve to "slap" shut. If a leakage is evident, repeat this test or replace the valve. Replace the Heating Element (20): CAUTION: Ensure that the boiler is cold, drained and has no pressure or electricity. 1. Remove the cabinet side panel 2. Remove the heating element terminal cover 3. Disconnect the wires from the heating element terminals. 4. Remove all 4 nuts from the element flange and pull out the heating element. 5. Clean the flange surface before installing the new element and gasket.

5. Trouble Shooting Boiler Status Power cord plugged into wall outlet, power switch on boiler control turned on, but no lights lit on the front panel of the boiler control: Quick Fix - Check circuit breaker or fuse of the wall outlet where the boiler is plugged in. If the circuit breaker is tripped or the fuse blown, check whether other appliances are plugged into outlets that are fed by the same circuit breaker/fuse. If that is the case, then plug those other appliances into outlets that are protected by other circuit breakers or fuses. Low Water alarm light lit: - Press the Low Water reset button - Check Water Level. Water level must be above the Min. mark. - Ensure that the boiler is filled with tab water and not distilled water. High Pressure alarm light lit: - Press the High Pressure reset switch - If the pressure gauge indicates steam pressure above the preset value, reduce pressure and press the High Pressure reset switch On JJ-Models: Pressure gauge shows pressure, but no steam can be discharged through jet when foot switch pressed: Boiler is hard to refill manually. When refilling, water gurgles in fill funnel: - Ensure that the steam outlet ball valve (2) is open - Ensure that the steam solenoid valve generates a click noise when the foot switch is pressed. If no click noise, then check the air hose of the foot switch for breakage or other damage. On JJ-Models: - Plug the power cord of the boiler into the wall outlet. - Turn the power switch on the boiler control on. - Open the steam outlet ball valve. - Press the foot switch while refilling. If trouble shooting did not resolve problem, please contact our service technicians at: Phone: 540-662-3811 Email: sales@reimersinc.com Web: www.reimersinc.com

Electra Steam, Inc. 4407 Martinsburg Pike Clear Brook, VA 22624 USA Phone: 540-662-3811 Fax: 540-665-8101 Email: Sales@reimersinc.com Web: www.reimersinc.com Parts List for Model JR2006 Steam Generator Table 1 1 04661 Pressure Gauge 0 160psi 2 02472 Ball Valve ¼ NPT 3 03346 Ball Valve ½ with latch 4 MBJ-1 Fill Funnel 5 02462 Swing Check Valve ½ NPT 6 02490 Ball Valve ½ NPT 7 02637 Safety Valve ½ NPT 100psi 8 02396 Gauge Glass Fixture Set ½ NPT 04201 Gauge Glass 5 04670 Gauge Glass Protector 5 02006 Gauge Glass Washer (Rubber) 02448 Gauge Glass Washer (Brass) 9 -------- Electronic Boiler Control, see Table 2 10 03266 Power Cord 125V 11* 04667 Solenoid Valve ¼ NPT 120V 12* 20708 Foot Switch Pneumatic Assembly 13* 20058 Steam Jet Brass #53 * JJ-Models only 7 4 5 6 3 11 8 Table 2 14 04396 Heating Light 125V 15 20720 Alarm Light Assembly 16 04213 Power Switch 16A 250V 17 20592 Reset Switch Assembly 18 04316 Low Water Cut-Off Circuit Board 19 MBJ187 Electrode Fitting 7.375 13 9 2 1 Table 3 20 02283 Heating Element 1500W, 120V 02281 Heating Element Gasket 21 01314 Nuts for Element Flange 22 04163 Pressure Control Operating 23 04296 High-Limit Pressure Control 14 15 10 12 16 17 19 18 23 21 20 22

APPLICATIONS JEWELRY CLEANING JIFFY HEAD FOR AUTO SEAT INSTALLATION HAT STEAMING IRON PRESSING DENTAL WAX REMOVAL