HEAT RECOVERY & POWERED VENTS

Similar documents
Heat pump and energy recovery systems

THE BENEFITS FROM ELIMINATING ROOF VENTING IN DRY KILNS

Brian Bond. Virginia Cooperative Extension Virginia Tech

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

INDUSTRIAL DEHUMIDIFICATION DRYING OF SOFTWOODS

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

CONDENSING BOILER TECHNOLOGY. James Romersberger Quintessence Corporation

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

The ultimate fresh air solution.

Heat Recovery Units. Heat Recovery 1

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, August 2015

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

CHURCH MUTUAL AND HARTFORD STEAM BOILER SENSOR TECHNOLOGY PROGRAM: IDENTIFYING FROZEN PIPE EXPOSURES

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Energy Recovery Ventilation

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

VENTILATION AND HEAT RECOVERY

DEHUMIDIFICATION DRYING OF SPRUCE STUDS. M. Y. Cech and F. Pfaff Eastern Forest Products Laboratory Ottawa, Ontario

Energy Efficiency HOSPITALITY.

2009 IECC Commercial Mechanical Requirements

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

b.) Technical Information:

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems

Benefits Offered by Passive Dehumidification Wheel Speed Control

Ventilation Techniques. Topic 5 - Audio 53

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Bill McCullough. Director ERV Products. Dallas, TX

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

The Ultimate in Direct Contact Water Heating. by Thermal Engineering of Arizona, Inc. An Inc. 500 Company

DEALING INTELLIGENTLY WITH ENERGY IN A HIGH-ENERGY PROCESS

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

Heat Exchangers in Swine Facilities

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

about your house Choosing a Dehumidifier

Review on Waste Heat Recovery Techniques in Air Conditioning Application

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

2018 International Energy Conservation Code (IECC) Updates

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Single Screw Ammonia Heat Pumps. Harness Your Heat... Don t Reject It

MECHANICAL SCIENCE Module 2 Heat Exchangers

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

HVAC Mandatory Provisions Part II, Page 1

RECENT UPGRADES TO DEHUMIDIFICATION KILNS TO DRY SOFTWOOD LUMBER

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Liquid Desiccant Air Conditioning Systems

Heat Pump Water Heaters

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Laboratory exercise 3: Condensing water heater

DUCTING FOR HRV SYSTEMS The distribution of airflows

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

9/18/2017. Nicholas Thornton, CEM. Systems: HVAC, Electrical, and Technology. Overview. Today s Goals Introductions HVAC Electrical Technology Q&A

TOWER COUNTER TOP STG

New generation heat exchanger improves industrial energy efficiency

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

Efficient Steam System Design

The Temperature and Relative Humidity Control in Cushing Library

Energy Conservation. Chapter 16

COMcheck Software Version Mechanical Compliance Certificate

High Efficiency Tankless Coil Boiler Alternative

COOLING / HEATING COILS

COMMON SENSE APPROACH TO OPERATING DRY KILNS WHEN BOILER CAPACITY IS LIMITED. William Brubaker Wellons, Inc. Sherwood, Oregon.

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Mold/Moisture Control Case Study

CHAPTER 4. HVAC DELIVERY SYSTEMS

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Passivhaus. Thompson Road and Carbis Close, Whitleigh, Plymouth. Your handy guide

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

United States Patent Frans

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

Operating Current. Height mm

Dehumidification Systems

Adsorption Chillers Energysmart Green Cooling

Heating with Wood. Part 2

MODELS VA3B, VB5B VC5B

Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Do All DOAS Configurations Provide the Same Benefits?

YEARLY VIEW. 6/28/2016

Transcription:

HEAT RECOVERY & POWERED VENTS

HEAT RECOVERY VENTING TOPICS HEAT RECOVERY DEFINITION HOW HEAT IS LOST WHILE DRYING HOW IS THE KILN BEING VENTED WHERE IS ENERGY CONSUMED WAYS TO PREVENT ENERGY LOSS POWER VENTING HOW HEAT RECOVERY WORKS HRV: HOW IT HELPS BENEFITS OF HRV

HEAT RECOVERY DEFINITION Heat recovery ventilation (HRV), also known as mechanical ventilation heat recovery (MVHR), is an energy recovery ventilation system using equipment known as a heat recovery ventilator, heat exchanger, air exchanger, or air-to-air heat exchanger which employs a cross flow or counter-flow heat exchanger (countercurrent heat exchange) between the inbound and outbound air flow. ~ Wikipedia

HOW HEAT IS LOST WHILE DRYING LUMBER VENTED AIR IS HOT HEAT IS LOST THROUGH VENTING AMBIENT AIR ENTERING THE KILN CHILLS THE AIR DEPENDING ON LOCATION OF VENTS, THE BUILDING CAN BE CHILLED THUS CAUSING CONDENSATION TO TAKE PLACE VAPOR THAT IS CHILLED TO WATER MUST BE REHEATED AGAIN TO VAPOR SOMETIMES KILN AIR THAT HAS JUST PASSED THROUGH HEAT COILS IS VENTED UNITENTIONAL VENTING LOSS THROUGH OTHER MEANS Vranizan, The Benefits From Eliminating Roof Venting in Dry Kilns, 1992

HOW IS THE KILN BEING VENTED VENTS OPEN ON WET BULB FOR CONVENTIONAL KILNS VENTS OPEN ON DRY BULB FOR DEHUMIDIFICATION KILNS HEAT EXCHANGER ONLY FOR MODERATE TO LOW LOAD CONDITIONS 85% HEAT EXCHANGER PLUS CONVENTIONAL VENTS FOR MAXIMUM LOAD CONDITIONS (15% +/-).

WHERE IS THE ENERGY CONSUMED IN A KILN WHILE DRYING? UP TO 50% OR MORE IS CONSUMED CONVERTING WATER TO VAPOR HEATING HEATING THE LUMBER - HEATING AIR CIRCULATION FANS AIRFLOW EQUIPMENT CONTROLS - CONTROLS FORCED EXHAUST POWERED VENTING Vranizan, The Benefits From Eliminating Roof Venting in Dry Kilns, 1992

WAYS TO PREVENT ENERGY LOSS IN A KILN IMPROVE DOOR, CEILING AND WALL INSULATION IMPROVE GASKET OR SEALS AROUND VENTS IMPROVE THE HEATING SYSTEM IMPROVE THE MAIN FANS (OPERATION, MAINTENANCE, CONTROLS, VFD) USE A HEAT RECOVERY SYSTEM Cooper,Methods of reducing the consumption of energy on wood drying kilns, 2003

POWER VENTING UTILIZES POWERED INTAKE AND EXHAUST REPLACES OR ASSISTS EXISTING VENTS EACH VENT HAS DOUBLE THE VENTING CAPACITY FOR USE IN NEW OR EXISTING KILNS INSULATED VENT LID WITH GASKETS REDUCES HEAT LOSS AND CONDENSATION INSIDE VENT LIDS PROTECT MOTORS FROM INTERNAL MOISTURE CONDITIONS

HOW HEAT RECOVERY VENTING WORKS WARM MOIST AIR IS REMOVED FROM KILN FRESH AIR FROM THE OUTSIDE IS PREHEATED AND RETURNED TO KILN HRV SYSTEMS RECOVER A PORTION OF THE LOST HEAT DURING THE DRYING PROCESS WATER CONDENSES AND FLOWS OUT THROUGH A DRAIN

HOW HEAT RECOVERY VENTING WORKS

HOW HEAT RECOVERY VENTING WORKS

HOW HEAT RECOVERY VENTING HELPS HEAT LOSS CALLS FOR ADDITIONAL HEATING TO TAKE PLACE AFTER VENTING HRV SYSTEMS TRANSFER A LARGE PORTION OF ENERGY FROM THE VENTED AIR TO THE INCOMING AIR HEAT EXCHANGERS HELP RECOVER HEAT LOST FROM VENTING BY UTILIZING AN AIR TO AIR EXCHANGER CONE WHICH PROVIDES UP TO 70% RECOVERY OF WASTED HEAT

SHOULD I USE A HRV SYSTEM WITH MY EXISTING KILN HAVE YOU ATTEMPTED TO MAKE YOUR KILN MORE ENERGY EFFICIENT ALREADY? DO YOU HAVE CONDENSATION BUILDING UP ON THE INSIDE OF YOUR KILN? DO YOU HAVE VISIBLE HEAT LOSS? DOES YOUR BOILER HAVE ADEQUATE CAPACITY? ARE YOUR FANS REVERSING AND USING A VFD? ARE YOU STACKING YOUR WOOD CORRECTLY AND BAFFLING?

HOW DOES A HEAT RECOVERY SYSTEM BENEFIT THE DRYING PROCESS CREATES MORE OF A CLOSED SYSTEM STYLE ENVIORNMENT DURING THE DRYING PROCESS THE KILN CHAMBER HAS A SMALLER RANGE OF CONDITION FLUCUATION REPORTS FROM CUSTOMERS OF SEEING BETTER COLOR IN HARDWOOD DRYING REPORTS FROM CUSTOMERS OF SEEING IMPROVED DRYING TIMES

MENTION OF HEAT RECOVERY VENTING IN KILNS MENTIONED IN DRY KILN OPERATOR S MANUAL, CHAPTER 11, PAGE 251 FUEL COSTS LOW, DOES IT STILL MAKE SENSE?

HEAT RECOVERY VENTING & MANUFACTURERS NYLE, SII DRY KILNS & OTHERS CURRENTLY HAVE INSTALLATIONS USING DIFFERENT CONFIGURATIONS OF HRV SYSTEMS COLLECTING DATA FOR USE IN QUALIFYING PROJECTS FOR HRV USAGE SUPPORTING KILN OPERATIONS TO IMPROVE EFFICIENCY

QUESTIONS