Controlled mechanical ventilation GB 03

Similar documents
RECUPERA DRY Controlled mechanical ventilation with dehumidification and air treatment GB 01. Air conditioning. Ideas to install

Low Temperature Radiator GB 01. Heating & Plumbing. Ideas to install

ECO HOT WATER Air-water heat pump for domestic hot water with integrated solar panels and remote control via App GB 02. Ecoenergy.

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

CONTROLLED MECHANICAL VENTILATION

DC INVERTER Air-Water heat pump for Heating and Cooling Residential environments with the PLANT MANAGEMENT SYSTEM INTEGRATED in the heat pump GB 04

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE

KOMFORT EC DB Suspended heat recovery air handling units

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

2013 innovation. Room-by-room demand controlled heat recovery ventilation

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

MECHANICAL VENTILATION

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

The Heating System and Ventilation and Combustion Air

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

Breathe Fresh Air at Home

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Elegance and design for your residential comfort

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

G Installation manual Solitude - dmev unit

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

Heat Recovery Air Handling Units

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

DOMESTIC LINE DUPLEX EASY

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

Fan Coil Range HYDRONIC TERMINALS

Installation manual Mori HR

TR Series - The Ultimate ERV

with minimal heat loss for a pleasant and healthy living environment

Healthy, comfortable and energy-efficient ventilation

Indoor Air Quality Product Brochure.

HRV Enthalpy. Catalogue

Ventilation & Heat Recovery. The whole house system from OMNIE

COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Tech to Tech May 07 HRV s & ERV s

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

HCV 4 - HCV 5 - HCH 5 - HCH 8

ComfoAir Q. Mechanical Ventilation and Heat Recovery

Operating Manual. Please keep this manual. with the unit! Cooling Unit. For Heat Recovery Unit santos (F) 570 DC. Status:

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

Indoor Air Quality Product Brochure.

The Sentinel Kinetic Horizontal Range

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Decentralised ventilation systems Trust the original.

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Temperature Relative Humidity

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

DEMAND-CONTROLLED HOME VENTILATION

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Ventilation Unit Zehnder ComfoAir 350

DOMEKT. Heat Recovery Air Handling Units

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Healthy, comfortable and energy-efficient ventilation

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

CHAP. 01 PAGE 6 CHAP. 02 PAGE 32 CHAP. 03 PAGE 71 MECHANICAL VENTILATION

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

User and maintenance manual

InspirAIR Home RESIDENTIAL AIR PURIFICATION

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

ENERGY RECOVERY VENTILATION (ERV)

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

Heat recovery unit RDKS

better ventilation Maximum effect minimum dimensions

ECO ROOF FAN. A modern, energy-saving roof fan with a DC motor. INSTALLER Register the roof fan for an extended 5 year guarantee!

TSEK VHR EC HEAT RECOVERY UNITS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

SMOKE CONTROL - NEW DIRECTIONS

Domestic & Commercial Fans

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Introducing the RetroVent

Building Regulations 2010: What it means to you.

Transcription:

RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install

Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s important that it be kept as clean as possible. Ventilation, whether mechanical or natural, allows us to control factors such as temperature, humidity and pollutants in the air, preventing the formation of surface and interstitial condensation and the subsequent development of unpleasant mould. Given that nowadays buildings are highly insulated against outside temperatures, it is becoming increasingly difficult to eliminate vapours generated in indoor environments on a daily basis. In fact, the mere presence of a person inside a room releases a significant quantity of moisture humidity. Moreover, simple actions such as washing our hands, drying clothes or cooking, release significant quantities of aqueous vapours. Unless the building is properly ventilated, this aqueous vapour will tend to condense on relatively colder surfaces such as the walls; if the building is properly ventilated however, this excess moisture will be pushed towards the outside, thereby preventing the formation of condensation. In addition to maintaining air temperature and relative humidity conditions, ventilation allows control over pollutants inside the home; simply think about the quantity of CO 2 each person releases when breathing, simple actions such as cooking (which releases fumes and odours into the environment), cleaning the home (which releases airborne organic compounds contained in cleaning products) or smoking a cigarette (which releases nicotine and other polluting elements). Moreover, inside the buildings hide a series of other pollutants often unbeknownst to us, such as pollens or insects (which enter the home during the different seasons throughout the year), radon (a natural gas found in soil, which infiltrates homes) or carbon monoxide (due to poor combustion in heating systems or stoves). So it s not only indoor environments that are polluted, but also outdoor ones. s a consequence however, given that rooms are ventilated during the part of the day when environmental pollution is at its highest, ventilation itself can be dangerous for the air we breathe. Until today, the most common method of exchanging air in indoor environments was to open the doors and windows, but given the hectic rhythms of modern day life, this isn t always easy. Moreover, compared to older buildings, modern construction technology has made building insulation even more efficient; however, while allowing us to use less energy for heating, this also results in significantly less air infiltration, particularly from the doors and windows. Unlike natural ventilation systems, a controlled mechanical system always ensures the right quantity of air is exchanged. The process is continuous and adjustable depending on the activities being performed by the occupants. The exchanged air is continuously controlled through a filtration system that prevents the introduction of pollutants from the outside. This is why Emmeti recovers your wellbeing, allowing you to live in a healthy environment thanks to correct air temperature and relative humidity conditions and significantly less pollutants.

Recover... your energy The cost of energy and power savings are a continuous source of worry during everyday life. simple gesture such as opening the doors and windows to exchange the air can increase the cost of heating in buildings by more than a third. In order to ensure correct ventilation in the home, as well as healthy conditions in the environments in which we live, doors and windows should be opened for twenty minutes every two hours; in addition to being a complicated operation in light of our daily routines, this is also extremely wasteful from an economical point of view due to the cold air that is subsequently let inside. On the other hand, a controlled mechanical ventilation system with heat recovery ensures the correct level of air exchange, with almost zero impact on heating costs. Thanks to high-efficiency heat recovery, the warm air present in the rooms cross with the cold air from the outside, without ever mixing, transferring the heat. This simple device reduces external energy dispersion throughout the various periods of the year. In fact, while it prevents heat from escaping the building in the winter months, it also prevents the heat from entering in the summer months, thereby significantly reducing building operating costs. Moreover, thanks to mechanical ventilation systems, it is possible to monitor the correct flow of air from the outside, based on the real needs of the building. This means that unlike in the case of natural ventilation by opening windows, occupants can enjoy a healthy environment, exchanging only the air effectively necessary in order to ensure maximum comfort. By recovering the energy already present in the different environments, the building becomes more efficient, less economically wasteful and requires less energy to work. ll this improve the building energy certification, helping to maintain and even improve the building s value over time. The Emmeti offer, also includes the standard version of the Recupera Slim model, which is controlled by external commands and an utomatic version supplied standard with a simple multi-purpose command for complete unit management. Both models can be combined with external sensors (motion, CO 2 and humidity) and are equipped with EC high-efficiency brushless motors, which considerably reduce consumption and allow improved regulation of the air flow based on the real needs of each individual system. This is why Emmeti recovers your energy, allowing you to live in an efficient home, with real energy savings.

The range 2018 SLIM -110 + B C D E F G 50 197 Mod. SLIM -110 (for ceiling installation) The unit is supplied with a multi-function control panel, featuring an LCD display with the following control/connection options: Set and select 3 speed Boost function, also activated from remote switch Holiday Mode / Night Mode Free cooling operation utomatic By-pass module Flow balancing Filter and fault maintenance indicator Operating time counter Save and load settings The unit is also equipped with: Free voltage contacts for the connection to remote sensors such as SEIRxx, SEHRxx, SECO2W 1-10V analogue input for slave mode if connected to a home automation system Output (230V ~ 5 max) for heating coil Output (230V ~ 5 max) for dehumidifier 135 26 23,5 60 110 Multi-function control panel

Building features CMV dual-flow ducted unit with heat recovery, suitable for horizontal false ceiling mounting. Recupera Slim is the ideal solution for residential buildings up to 100 m 2. B 3 5 2 1 D C 4 6 4 5 6 1 External frame made of galvanised steel which gives the structure robustness and reliability over time. The unit is RL 9010 powder coated. 2 Internal structure made of expanded polypropylene to minimise thermal bridges, sound emission and to ensure maximum tightness. 3 EC external rotor motors with low energy consumption. Equipped with thermal protection and mounted on ball bearings to guarantee durability. 4 Centrifugal fan with balanced reversed blades dynamically and directly coupled to the motor, high performance and low noise. 5 Very high efficiency heat exchanger, cross-flow, counter-current. 6 Electrical panel. Outlet exaust air (outdoor). B Inlet fresh air (outdoor). C Flow fresh air (indoor). D ir intake exaust air (indoor).

How Recupera Slim autonomous works The exhaust air from the more polluting rooms like bathrooms, kitchens and laundry rooms is expelled by a mechanical ventilation system, introducing clean air taken from outdoors into noble areas like living rooms or bedrooms, recovering the energy in the exhaust air. 1 5 5 5 2 3 3 4 5 Fresh air Exaust air The system is made of the following components: 1 Recupera Slim: 2 fans actioned by low consumption brushless motors, force inlet air flow (from internal rooms) and external air throughout a high efficiency-crossed flows heat recovery unit. In this way the internal heat can be recovered. The air is taken from the rooms and from outside by the fans, and passes them through the recovery unit at highly efficient crossed flows, recovering the energy contained inside the house. 2 Multi-function control with LCD display: controls the ventilation flow rate and gives information on any filters cleaning or replacements. 3 External air grills: allow inlet and expulsion of air avoiding entrance to the building of foreign bodies and water. 4 Distribution plenum: it is a piping network within the building that distributes and regulates air inside the building, avoiding transmission of noise inside the house. 5 Terminals: they distribute the air flow inside rooms avoiding creation of annoying drafts and transmission of noise between different rooms.

Technical characteristics Easy installation: 243 mm height (max. 269 mm, including mounting brackets and condensing drainage) in order to be installed within low height spaces. Bypass integrated ideal for the free cooling working during summer time with automatic activation G4 filter easily extractable from the outside: for maintenance operations. It is not necessary to remove the access panel. External F/ filters under request. utomatic frost protection to prevent ice forming on the inlet side of the exchanger. Two drainage holes to be used depending on season time. s a proof of maximum reliability on electrical safety tests, performancies and noise level, the units are tested in the TÜV Rheinland recognised laboratory. Designed and manufactured according to the standard EN 60335-2-80 (Low Voltage Directive) and the EMC Directive (Electromagnetic Compatibility). Technical data Models u.m. SLIM -110 In accordance with Regulation EU n 1254/2014 Maximum flow rate (*) m 3 /h 177 Electric power input at maximum flow rate (*) W 105 Specific energy consumption class (**) B / / Thermal efficiency of heat recovery % 82 Reference flow rate m 3 /s 0,0344 Reference pressure difference Pa 50 Specific power input SPI W/(m 3 /h) 0,412 Sound power level L W db() 50 Sound power level V~ / Hz 220-240 V~ / 50 Hz Max power input W 105 Max current 0,9 IP protection rating - IPX4 Filters G4/G4 Weight kg 18,5 Max air temperature C 0 40 Max air relative humidity % 10 95 (*) Values referred to a useful static pressure 100 Pa (**) With: Manual control / Centralized control system / Local control system eraulic performance measured according to the standard ISO 5801 at 230V~ 50 Hz, air density 1.2 kg/m 3 Dimensions [mm] 65 1037 906 738 10 Winter condensing drain. B Summer condensing drain. C Wiring connections box. Ø 125 240 536 243 259 269 408 B 602 128 650 17 226 9 C 308 290 308 66 353 319 232 66

eraulic performances Static pressure [Pa] 500 450 400 350 300 250 F G 200 150 D E 100 C 50 B 0 0 20 40 60 80 100 120 140 160 180 200 220 Position ir flow [m 3 /h] ccessories supplied separately Speed selector Power input [W] Presence sensor Current [] Humidity sensor Static pressure [Pa] CO 2 sensor ir flow [m 3 /h] Electric heater Heating / cooling F7 filter module Silencer water coil EMMETI spa - Via Brigata Osoppo, 166-33074 Vigonovo frazione di Fontanafredda (PN) - Italy Tel. +39 0434.567911 - Fax +39 0434.567901 - www.emmeti.com - info@emmeti.com Sound power [db()] (20%) 10 0,1 15 15 32 B (35%) 15 0,1 50 20 38 C (53%) 28 0,2 100 40 45 D (60%) 36 0,3 100 65 47 E (70%) 47 0,4 100 90 50 F (85%) 77 0,7 100 140 56 G (100%) 105 0,9 100 177 62 Filter replacement No-return valve 9900935400001 Rev. B - 06.2018 - Ufficio Pubblicità & Immagine - BT ll rights are reserved. This publication or any of its contents can be reproduced or publicized without Emmeti s writtern authorization