REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Similar documents
REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System

FLASHLIGHT ANSI STANDARDS

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

lumenalpha downlight Specification Sheet

Product Description. Features. Table of Contents. CLM-DS08 Rev 11. Product family data sheet. Source with

Fast. Precise. Versatile. UL Lighting Sciences

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

SECTION INTERIOR LIGHTING

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

ENGINEERING EVALUATION

Vaya Linear LP, White & Mono

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

LED Reliability and Current Standards for Measurement

E10 & L9 Low Wattage Light Cone Data

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

Optics & Radiometry Laboratory

SIGMADEK, LTD. FIRE TEST REPORT

Fortimo LED Line High Flux Module

Refrigerating Appliance DOE Test Report

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Optical Testing Report for 46 Lamp Sample Sets

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Optical Measurement Techniques for LED Clusters and LED Safety

Lighting Measurement Solutions

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

Rating. Class I Div II

Table of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming...

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Fortimo LED Line Gen2 Module

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

Product Specifications MaxLumen MRI LED Diffused Lighting

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Dimensions (111mm) (111mm) 3 (76mm)

SDL4 LED Strip Diffused Lens

In Situ Temperature Measurement

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant

FUNDERMAX GMBH FIRE TEST REPORT

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

Product Specifications MaxLumen MRI LED Diffused Lighting

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

FPLHB - Fidelux Premier Linear Highbay

BAS SDL8' LED Strip Diffused Lens

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

Recessed LED Wall/Slot SAE 202

Technical application guide

Highbay Linear LED Series Flat Profile Design

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Technical application guide

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Technical Application Guide for UP-SHINE LED Track Light

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

Ultra Energy Efficient

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

This is a preview - click here to buy the full publication

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Efficient Lighting MVE Infrastructure Status Report and Overview. Steve Coyne. Consultant, UNEP en.lighten

OLUX LED IN-GROUND OSRAM. Datasheet

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Fire Performance of Translucent Systems

SYSTEM. field cuttable. lipleds 8200 Series

Refrigerating Appliance ErP Test Report

Cree XLamp MT-G MR16 Reference Design

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

LUXCOMFO TM LED Flood Light Datasheet

2018 Midstream Lighting Product Catalog

Cove Light AC Dim. Electrical Protection Class II, cetlus. Compatible with and controlled by leading/trailing edge phase-cut dimmers

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ELLA ID. High CRI, High lm/w OptoDrive LED-module

Transcription:

. REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: December 20, 2016 REPORT NO. 102748333CHI-015 TEST OF ONE T8 LED TUBE MODEL NO. T8-NW18F LED MODEL NO. HONGLI OPTO-ELECTRONIC / HL-A-2835HW-S1-08L-HR3 DRIVER MODEL NO. BYMEA / T08J01_R0 RENDERED TO SUPER BRIGHT LEDS, INC. 4400 EARTH CITY EXPRESSWAY SAINT LOUIS, MO 63045 TEST: Electrical and Photometric tests as required to the IESNA test standard. AUTHORIZATION: The testing performed was authorized by signed quote number Qu-00723537-3. STANDARDS USED: The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79-2008: Electrical and Photometric Measurements of Solid State Lighting ANSI NEMA ANSLG C78.377: 2012: Specifications of the of Solid State Lighting Products DESCRIPTION OF SAMPLE: The client submitted one production sample of model number T8-NW18F. The sample was received by Intertek on December 16, 2016, in undamaged condition and one sample was tested as received. The sample designation was 12162016023157. DATES OF TESTS: December 19, 2016 through December 20, 2016. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY Model No.: Description: T8-NW18F T8 LED Tube Result Criteria Sphere Goniometer Total Lumen Output (Lumens) 1918 1987 Total (W) 18.46 18.22 Luminaire Efficacy (LPW) 103.9 109.1 Criteria Result Factor at 120Vac 0.604 Factor at 277Vac 0.635 Current ATHD % at 120Vac 34.27 Current ATHD % at 277Vac 15.73 Correlated Color Temperature (CCT - K) 4116 Color Rendering Index (CRI - Ra) 83.3 Color Rendering Index (CRI - R9) 9.1 DUV 0.001 Coordinate (x) 0.376 Coordinate (y) 0.378 Coordinate (u') 0.222 Coordinate (v') 0.501 EQUIPMENT LIST Equipment Used Yokogawa Meter Omega Newport Thermometer LSI High Speed Mirror Goniometer Newport Thermohygrometer Pacific, AC power supply Labsphere Spectroradiometer 3 Meter Sphere Elgar AC Supply Sorenson DC Supply Newport Humidity Recorder Yokogawa Meter Omega Temperature Meter Model Number WT210 Control Number 146919 Last Date Calibrated 07/11/16 Calibration Due Date 07/11/17 DPI8-C24 146920 10/07/16 10/07/17 6440T 146928 VBU VBU iserver 146956 01/04/16 01/04/17 118-ACX CHI0358 VBU VBU CDS1100 CHI0091 VBU VBU SPR600 CHI0088 VBU VBU CW1251M 146112 VBU VBU XFR150-8 146846 VBU VBU ithx-sd 146382 06/27/16 06/27/17 WT1600 146768 01/14/16 01/14/17 MDSi8 146139 03/21/16 03/21/17 Date Used Report No. 102748333CHI-015 2 of 7 Date: December 20, 2016

TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Analyzer. Some graphics were created with Photometrics Plus software. Report No. 102748333CHI-015 3 of 7 Date: December 20, 2016

RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) - Integrating Sphere Method Intertek Sample No. 12162016023157 Base Orientation Up Voltage {Vac} Current (ma) (Watts) Factor 120.0 254.7 18.46 0.604 277.0 106.3 18.70 0.635 Current ATHD (%) 34.27 15.73 Luminous Flux (Lumens) Lumen Efficacy (LPW) 1918 103.9 Correlated Color CRI CRI CIE 31 CIE 31 CIE 76 CIE 76 Temperature (K) -Ra -R9 DUV Coordinate (x) Coordinate (y) Coordinate (u ) Coordinate (v ) 4116 83.3 9.1 0.001 0.376 0.378 0.222 0.501 Spectral Distribution over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm nm mw/nm 350 0.165 440 15.16 530 22.90 620 26.68 710 2.953 355 0.158 445 23.00 535 23.54 625 25.03 715 2.525 360 0.167 450 30.53 540 24.21 630 23.27 720 2.163 365 0.160 455 29.88 545 24.91 635 21.45 725 1.841 370 0.145 460 23.19 550 25.63 640 19.56 730 1.575 375 0.132 465 18.33 555 26.40 645 17.72 735 1.343 380 0.129 470 14.99 560 27.20 650 15.91 740 1.146 385 0.134 475 12.11 565 27.99 655 14.22 745 0.976 390 0.153 480 10.92 570 28.84 660 12.62 750 0.832 395 0.195 485 11.05 575 29.59 665 11.08 755 0.716 400 0.266 490 11.96 580 30.27 670 9.704 760 0.617 405 0.424 495 13.54 585 30.76 675 8.462 765 0.527 410 0.744 500 15.44 590 31.05 680 7.359 770 0.453 415 1.302 505 17.26 595 31.00 685 6.369 775 0.390 420 2.240 510 18.81 600 30.76 690 5.477 780 0.335 425 3.812 515 20.20 605 30.21 695 4.724 430 6.210 520 21.30 610 29.31 700 4.043 435 9.820 525 22.17 615 28.09 705 3.458 35.000 30.000 25.000 Spectral Data Over Visible Wavelengths (mw/nm) 20.000 15.000 10.000 5.000 0.000 350 400 450 500 550 600 650 700 750 800 Nanometers Report No. 102748333CHI-015 4 of 7 Date: December 20, 2016

RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Intertek Sample No. Base Orientation Voltage {Vac} Current (ma) (Watts) Factor Absolute Luminous Flux (Lumens) 12162016023157 Up 120.1 175.1 18.22 0.867 1987 Lumen Efficacy (LPW) 109.1 Intensity (Candlepower) Summary at 25 C - Candelas Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 0 22.5 45 67.5 90 372 372 372 372 372 363 366 370 376 380 356 361 367 374 380 346 352 361 372 378 332 339 353 366 374 316 324 342 359 368 296 307 328 349 360 274 286 313 336 349 250 264 295 322 336 225 240 276 307 322 197 216 256 290 306 170 191 236 274 291 142 167 216 258 275 113 143 198 242 260 85 121 180 226 245 59 101 164 211 230 34 84 149 196 215 13 70 136 183 201 1 61 125 171 188 3 55 116 160 178 7 52 110 150 167 13 51 103 142 157 18 52 99 134 148 24 54 94 127 140 29 56 91 121 133 35 60 89 115 126 40 63 87 110 120 44 66 86 105 114 49 70 86 101 108 53 73 86 97 104 56 73 85 95 100 59 71 85 93 97 62 70 85 90 94 63 68 79 87 91 65 66 74 79 83 66 66 67 70 73 67 67 67 67 67 Report No. 102748333CHI-015 5 of 7 Date: December 20, 2016

RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 10 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zonal Lumens and Percentages at 25 C Zone 0-30 0-40 0-60 60-90 0-90 90-180 0-180 Lumens % Luminaire Zone Lumens % Luminaire 295.9 14.9 0-10 35.3 1.8 492.1 24.8 10-20 102.4 5.2 915.5 46.1 20-30 158.2 8.0 496.1 25.0 30-40 196.2 9.9 1412 71.0 40-50 213.0 10.7 575.4 29.0 50-60 210.4 10.6 1987 100.0 60-70 192.6 9.7 70-80 166.1 8.4 80-90 137.4 6.9 90-100 117.1 5.9 100-110 102.5 5.2 110-120 90.2 4.5 120-130 78.4 3.9 130-140 66.2 3.3 140-150 53.2 2.7 150-160 38.5 1.9 160-170 22.5 1.1 170-180 6.8 0.3 Report No. 102748333CHI-015 6 of 7 Date: December 20, 2016

PICTURES (not to scale) X CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Hector Huitron Associate Engineer Lighting Division Timothy Quigley Engineer Lighting Division Attachment: None Report No. 102748333CHI-015 7 of 7 Date: December 20, 2016