Unit Type: Air Handling Unit & Compressor Skid (AHU+CSV) Project Name: FGP LER Substation 51 Cooling Duty: No. 2 x 228 kw Site Location: Kazakhstan Year: 2017 End User: TengizChevrOil Manufacture of 2 Compressors Skid Units, associated to 2 Air Handling Units and coupled to Air Cooled Condensers. EAC Certification; Power supply: 380V / 3 Ph / 50Hz; Base frame in low temperature carbon steel sheet P355 NL; Air Handling Unit characteristics: Screw compressor with star/delta staring; Casing in AISI 304L; External & Internal panels material AISI 304L; Doors for inspections mounted in Fans section, Filter section and Mixing section; Each section is provided with internal light; Actuated damper with IP66 electric actuator; G4 and F7 Class filters; Electrical equipment for continuous operation within 0 C to 45 C; Drip trays in AISI 304L; Drop eliminator AISI 316L. 37
Unit Type: Air Cooled Condenser Unit (ACCU) Project Name: FGP LER Substation 51 Cooling Duty: No.4 x 160,5 kw (Total heat rejection capacity) Site Location: Kazakhstan Manufacture of 4 Air Cooled Condenser Unit associated coupled to Compressors Skid Units EAC Certification; Power supply: 380V / 3 Ph / 50Hz; C-Channel skid base in AISI 316L; Frame, snow protection, louvers and grids in AISI 316L; Snow protection material AISI 316L; Condenser fans with impeller, impeller hub, structure, cone inlet e protection grids in AI SI 316L; Condenser fan motor IP56, frame in Cast iron and painted as per project specification; Protection of refrigerant circuits accessories AiAx Silver; Stainless steel junction box. 36
Unit Type: Chemical filter Unit Project Name: FGP LER Substation 51 Cooling Duty: No. 1 x 19755 m 3 /h Site Location: Kazakhstan Manufacture of a Chemical filter unit for recirculating air. EAC Certification; Power supply: 380V / 3 Ph / 50Hz; Base frame in low temperature carbon steel sheet P355 NL. Casing in aluminum alloy; External & Internal panels material galvanized steel; Doors for inspections mounted in Fans section, Filter section and Mixing section; Each section is provided with internal light; Actuated damper for recirculating air with IP66 electric actuator; Non return damper on plug fan; G4 Class filters. 35
Unit Type: Chemical filter Unit Project Name: FGP LER Substation 51 Cooling Duty: No. 1 x 5510 m 3 /h Site Location: Kazakhstan Manufacture of a Chemical filter unit for fresh air. EAC Certification; Power supply: 380V / 3 Ph / 50Hz; Base frame in low temperature carbon steel sheet P355 NL. Casing in aluminum alloy; External & Internal panels material galvanized steel; Doors for inspections mounted in Fans section, Filter section and Mixing sect ion; Each section is provided with internal light; Actuated damper for fresh air with IP66 electric actuator; Non return damper on plug fan; G4 Class filters. 34
Unit Type: HVAC coordination panel Project Name: FGP LER Substation 51 Cooling Duty: - Site Location: Kazakhstan Self-standing control system based on Allen Bradley redundant PLCs with operator interface. Totally integrated in the control philosophy of the Fire & Gas plant System. Allen Bradley redundant CPU; Redundant I/O; Indoor Installation; RAL 7032; Front and rear access; RITTAL Carbon steel casing; HMI display 14 in English and Russian Language; TR/CU 04 and TR/CU 020 certificates compliance. 33