Historical Perspectives for Hydrogen Safety, Regulations, Codes and Standards (California and U.S.A.)

Similar documents
A NATIONAL SET OF HYDROGEN CODES AND STANDARDS FOR THE US

REVISION RECORD FOR THE STATE OF CALIFORNIA ERRATA

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

THE NATIONAL CODE SERVICES ASSOCIATION (NCSA)

The Cannabis Industry: Fire Department Requirements

SOUTH CAROLINA LIQUEFIED PETROLEUM GAS PROGRAM (LP-GAS)

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

ORDINANCE NO. 787 (AS AMENDED THROUGH 787.7) AN ORDINANCE OF THE COUNTY OF RIVERSIDE ADOPTING THE 2013 CALIFORNIA FIRE CODE AS AMENDED

Bruce E. Johnson Underwriters Laboratories 395 Kingston Drive Ridge, New York Phone: (631)

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

REVISION RECORD FOR THE STATE OF CALIFORNIA SUPPLEMENT

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

Plant Processing and Extraction Facilities

2015 International Fire Code

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

California s Enhancement of Public and Firefighter Safety Through Codes and Standards The New Fire Triangle

Attention: Sharon Dickinson, Legislative Assistant, Planning and Land Use Management Committee

NFPA Fire Inspector I Study Guide

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

IRO Reliability Coordinator Real-time Reliability Monitoring and Analysis Capabilities

Standard Development Timeline

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

Overview of Standards for CO Detection Products

Carbon Dioxide Enrichment Systems

PRESENTERS OVERVIEW COMMUNITY WORKSHOP OVERVIEW OF THE 2010 EDITION OF THE CALIFORNIA BUILDING STANDARDS CODE AND LOCAL AMENDMENTS

CHAPTER FIRE CODE

Fire Code Action Committee (F-CAC) Meeting Minutes June 19-20, 2012 Chicago IL. Summary of Actions and Regional Work Group (RWG) Assignments

2015 Recommended Building Code with Amendments. The Executive Committee of the Central Iowa Code Consortium does ordain as follows:

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

BP OIL -- TOLEDO REFINERY

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Fire Department Fees.

UC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

Codes And Standards Nfpa

OPERATIONAL PERMIT STORAGE MAGAZINE PERMIT APPLICATION

HYDROGEN EMERGENCY RESPONSE TRAINING FOR FIRST RESPONDERS

Compliance Guidance for non-technical managers

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Safe Operating Procedure

Fire Plan Review and Inspection Guidelines

U.S. Codes & Standards for Energy Storage Systems. Joe Cain, P.E. Chair, SEIA Codes & Standards Working Group

CLASS POWER ENGINEER S CERTIFICATE

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

City of Los Angeles, Bureau of Engineering staff report - dated October 14, 2009 and the Hearing Examiner Report signed October 21, 2009.

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

New Fire Codes and Your Business 2018 WPA Annual Meeting Palm Springs, CA

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Roof Coatings Manufacturers Association October 18, 2012

2014 NFPA Conference & Expo

TECHNICAL COMMITTEE ON FIRE CODE

CERTIFICATION BULLETIN

Title: BFST1505 Syllabus

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

Onsite Fire Risk Reduction Methods

Los Angeles International Airport Rules and Regulations SECTION 08 FIRE AND SAFETY

FIRE ALARM PRE-INSPECTION CHECKLIST 1. REFER TO CHAPTER 10 OF CURRENT STATE ADOPTED NFPA 72, FOR INSPECTION, TESTING AND MAINTENANCE PROCEDURES.

Why did we come up with this system?

FIFTH CLASS POWER ENGINEER S

Nfpa 13 Automatic Sprinkler Systems Handbook 2010 Edition Pdf

ARTICLE 25. FUEL GAS CODE

ORDINANCE NO, 5907 AN ORDINANCE AMENDING ALBANY MUNICIPAL CODE CHAPTER , UNIFORM FIRE CODE

30 DAY TEMPORARY TENT APPLICATION ON EXISTING COMMERCIAL PROPERTY

H gh-p led Combust ble Storage. Application Guide 2009 Edition

Salve Regina University Fire Safety Policy for Events in Assembly Occupancies (Original 2006 revised & updated January 2010 & October 2014)

NGV MAINTENANCE FACILITIES Code Related Modifications For NGVs In Existing Maintenance Facilities

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

Committee on NFPA 51A

Report on First Revision June 2014 NFPA 5000

Brighton Area Fire Authority

CTC Meeting #27 JUNE 17 18, 2013 NIST report on the Charleston sofa store fire

Hydrogen Refueling Code Gap Assessment

NEW ENERGY IN THE BATTERY INFRASTRUCTURE

HIGH-RISE RETROFIT ORDINANCES - NO and NO

BUILDING/FIRE CODE REFERENCES 2006 EDITION

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV (702) FAX (702)

Update on ASHRAE 15 Safety Standard for Refrigeration Systems Karim Amrane Air Conditioning, Heating & Refrigeration Institute (AHRI)

(h) Pesticide Application.

Committee on 51A M E M O R A N D U M. NFPA Technical Committee on Industrial and Medical Gases

S 2758 S T A T E O F R H O D E I S L A N D

FIRE PROTECTION INTRODUCTION

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Be Alarmed! Smoke Alarm Installation Program Fire Department Guide

Builders Risk - Fire Prevention Inspection Checklist

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

State of California Department of Consumer Affairs Green Science Policy Workshop for Manufacturers and Retailers

INTRODUCTION. Page 1 of 5

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

2012 International Fire Code Errata (Portions of text and tables not shown are unaffected by the errata)

CHAPTER House Bill No. 69

Recent Revisions and Proposed Key Changes to Fire Code

Adoption of The 2007 Dallas Fire Code

Single Room Occupancy Hotel Safety & Stabilization Task Force

Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333

For additional information regarding R-3.1 residential care facilities please contact (951)

American Fire Sprinkler Association. An Introduction to the IBC and IFC

Transcription:

Historical Perspectives for Hydrogen Safety, Regulations, Codes and Standards (California and U.S.A.) Jennifer Hamilton 11 September, 2013

CA overview

CaFCP hydrogen fueling station West Sacramento» Second hydrogen station built in Ca» Built by Texaco, BP, Chevron, Shell, Air Products, Praxair Jurisdiction: City of West Sacramento and West Sacramento Fire Department To be decommissioned October, 2013

West Sacramento Station

Applicable C&S Then» 2001 California Fire Code, Title 24, Part 9 Article 29: Repair Garages Article 52: Motor Vehicle Fuel Dispensing Stations Article 74: Compressed Gases Article 75: Cryogenic Fluids* Article 80: Hazardous Materials As of January, 2014» 2013 California Fire Code, Title 24, Part 9 Chapter 23: Motor Fuel-Dispensing Facilities and Repair Garages Chapter 53: Compressed Gases Chapter 55: Cryogenic Fluids* Chapter 58: Flammable Gases and Flammable Cryogenic Fluids* * If the station stores LH2

Applicable C&S Then» 1998 California Building Code, Title 24, Part 2 Part 1 for any Green Building standards» 2000 California Electrical Code, Title 24, Part 3» 2001 California Mechanical Code, Title 24, Part 4 Current (as of Jan. 14)» 2010 California Building Code, Title 24, Part 2 Part 1 for any Green Building standards» 2010 California Electrical Code, Title 24, Part 3» 2010 California Mechanical Code, Title 24, Part 4

Model Code Developers ICC» International Fire Code: California s (and most state s) model fire code Some use NFPA 1 as model fire code (Northeast and Hawaii)» Currently in a revision cycle for 2015 Input includes topics on hydrogen, fueling stations and repair facilities Ca to adopt this as the 2016 CFC, effective January 1, 2017 NFPA» CFC has referenced NFPA 50 A/B, then NFPA 52 and 55» All hydrogen-related items from NFPA 52 have now been removed» NFPA 55 is currently in revision cycle, as well» NFPA 2, the Hydrogen Technologies Code, includes excerpted hydrogen material from NFPA 52 and other documents, as well as references to other NFPA documents The 2011 version is undergoing revision for a 2015 edition

Code adoption California: IFC = model fire code This does not guarantee uniform code adoption throughout each jurisdiction in the state Depending upon a jurisdiction s code adoption cycle, they may be using previous versions of the CFC» Or in other states in the US Jurisdictions can also amend the CFC during adoption Potential issues with permitting a station

Per garantire la privacy, il download automatico di questa immagine è stato bloccato da PowerPoint. CFC amendment example: City of Merced, CA» We are working on code adoption and was wanting to see if anyone is making an amendment to not allow Sky Lanterns and if they would be willing to share their language.

Reply from County of Los Angeles Fire Department Here is one I drafted and, below that, how Orange County proposes to handle the issue. I m still considering the language I drafted. LA COUNTY DRAFT: FLOATING LUMINARY is an unpiloted floating air borne device containing open flaming or smoldering material capable of causing ignition to combustibles it may come in contact with. Floating luminaries may also be referred to as sky lanterns, flying lanterns, sky candles and wish lanterns. 308.1.6.1.1 Floating luminary use. The use or release of a floating luminary is prohibited. Exception: When a permit is issued by the Fire Code Official for use or release of a floating luminary for ceremonial, educational, or research purposes and where approved safeguards are used to prevent unintended ignition of combustibles. Floating luminary use or release shall be allowed only at a specific location and during prescribed weather conditions. ORANGE COUNTY DRAFT: SKY LANTERN. An airborne lantern typically made of paper, Mylar, or other lightweight material with a wood, plastic, or metal frame containing a candle, fuel cell, or other heat source that provides buoyancy. 326 Sky Lanterns or similar devices. The ignition and/or launching of a Sky Lantern or similar device is prohibited. Exceptions: Upon approval of the fire code official, sky lanterns may be used as necessary for religious or cultural ceremonies providing that adequate safeguards have been taken as approved by the fire code official. Sky Lanterns must be tethered in a safe manner to prevent them from leaving the area and must be constantly attended until extinguished.

CFC amendment example: Huntington Beach FD Group, In preparation for the upcoming code adoption, we are considering the following amendments: 113.3 Work Commencing before permit issuance, Amended. Any person who commences any work, activity or operation regulated by this code before obtaining the necessary permits shall be subject to an additional fee that is equal to the original permit fee, which shall be in addition to the required permit fees. Rationale - Existing code language indicates that the governing authority may charge an additional fee for work commencing before permit issuance. The purpose of this amendment is to clarify the amount of the fee that will be charged in Huntington Beach if work commences without the required permit. The fee will offset the required additional city resources to back track, investigate and review projects. The fee will also serve as deterrent for unpermitted work which will lead to more code compliant structures. Section 510.6.1 Testing and proof of compliance, Amended. 5. At the conclusion of the testing, a report, which shall verify compliance with Section 510.5.4, shall be submitted to the fire code official. In addition, one complete copy of the report shall be posted in the building, on the wall immediately adjacent to the Fire Alarm Control Panel. Rationale - The Fire Department is charged with responsibility to check on the annual testing. By requiring the posting of a copy of the test results on the alarm panel this may be done during the annual inspection and does not require the occupants to retrieve the information from a business office (if they can find it at all). It also gives the inspection crews (who will be responding to the location in the event of a fire) to see the status of the system and be more aware of potential problem areas during their annual inspections. Anyone out there have something similar? If so, please respond directly back to me.

http://opr.ca.gov/docs/governor's_office_zev_action_plan_(02-13).pdf

2013 ZEV Action Plan

2013 ZEV Action Plan Ca Office of Planning and Research Funding and job description for an Ombudsman in the Governor s» Mediate between government and industry» Work with State Fire Marshal s office for items related to safety/permitting

ZEV Readiness Guidebook A community readiness guide with resources and information (for plug ins and fuel cells) Part of the effort to streamline permitting» Regulations, Codes, and Standards (RCS) Template for California Hydrogen Dispensing Stations (NREL) Due to be released in the coming weeks ZEV Toolkits to follow from the California Air Resources Board

Role of the State FM in ZEV AP CaFCP working with OSFM Division Chief, Code Development and Analysis Division on updated hydrogen language for Ca» Supplement to include new hydrogen language from the 2015 IFC: effective July 1, 2015 Eventually, reference 2015 NFPA 2 in the 2018 IFC, adopted into 2019 CFC, enforced January 1, 2020» Amend the model fire code (i.e. 2016 CFC)» Another supplement effective July, 2018

CaFCP activities Emergency Responder and Permitter/AHJ education & outreach» With the U.S. DOE & National Renewable Energy Lab» Developing a National ER Education Program through Pacific Northwest National Lab Community Readiness Legislative Outreach Retail Station Developers Safety, Codes & Standards development/input» U.S. DOE Codes & Standards Tech Team» FCHEA National Hydrogen & Fuel Cells Codes & Standards Coordinating Committee, Transportation Working Group,» Hydrogen Codes Task Force

Specific documents NFPA 2- Hydrogen Technologies Code CSA HGV 4-series (station components and systems) ISO TC 197- new WG for hydrogen stations, other station component work items ICC- IFC CDFA, DMS- metering CA OSFM- CFC Support harmonization with International C&S development

Upcoming Codes & Standards for California/USA IFC» Undergoing revision (2015 version)» 2015 IFC 2016 CFC (effective January, 2017)» Ca to reference new IFC language in a supplement effective July, 2015 NFPA 2» Current version = 2011 Referenced in CFC» Under revision for 2015 (includes new H2 language and chapters previously reserved )» Goal: reference NFPA 2 in the IFC, for adoption into the CFC (approximately 2020) Very possible to have enforceable language prior to 2020 Jurisdictions can use NFPA 2 as an alternate means and methods

Looking forward Installing hydrogen facilities will become easier and faster» More experience of AHJ s» CFC will reference NFPA 2» Technology advancements» More standardized design

In the mean time continue. Outreach and education» Emergency responders» Permitting officials» General public Assisting station developers Readying the market Readying communities Sharing experience Collaborating and harmonizing

Visit www.cafcp.org Jennifer Hamilton Safety & Education Specialist jjhamilton@cafcp.org 916-375-4914 direct 916-267-4083 cell