Intellia Sounder Bases and Sounder Beacon Bases

Similar documents
SOUNDER BASES AND SOUNDER BEACON BASES

XP95 Sounder VAD Base

Analogue addressable devices

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES

Opal TM AV Devices. Data Sheet. Benefits

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

Opal TM AV Devices. Data Sheet. Benefits

XP95 Product Guide MAN 3037

Addressable Loop Powered Visual Alarm Devices

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

System 800 Addressable Fire Detection & Alarm System

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Fire Signalling. Signalling Solutions

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Conventional Fire Detection

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

4 wire conventional alarm system

MINERVA MZX125 Digital Addressable Fire Detection System

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Conventional Audible Visual Range

Xenex Conventional Fire Detection & Alarm System

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Fire Signalling. Signalling Solutions

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

The new detector from Rafiki

Product Guide MAN7030-2

Intelligent addressable fire alarm control panel

Fire Alarm Control Panel. System Maintenance and Log Book

MINERVA MZX125. Digital Addressable Fire Detection System

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

EN54-23 Beacons & Sounder Beacons

IQ8Control C Fire Alarm Panel

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Emergi-Lite Orbis detectors

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Conventional Fire Alarm System 2014 V1.2

X10 Mini, Midi & Maxi

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Fire Signalling. Signalling Solutions

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Our technology, your peace-of-mind. Product list

The supplier and installer of the system should be approved by the local civil defence authority.

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

SOUNDER CONTROL MODULE SCM-AS4

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Fire Product Catalog

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

SAFETY INTEGRITY LEVEL MANUAL. IEC and IEC XP95 and Discovery SIL Approved Product Range

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

The EN54 Part 2 & 4 Fire System

SERIES 65 ENGINEERING PRODUCT GUIDE

SOUNDER WITH BEACON FOR FIRE DETECTION PANEL

Product Manual Standard Asserta Sounder Range

INPUT / OUTPUT MINI MODULES

Intelligent Security & Fire Ltd

Sounder AX03, AX05. Loud signalling device with 32 different signals. Application. Design. Signalling devices with good directivity

Evolution Analogue Addressable Fire System

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

FlexSQUARE Square shaped beacons

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

The complete conventional fire warning system

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

2000 Series Sensors Installation Guide

XP95 ENGINEERING PRODUCT GUIDE

XP95/Series 90 Test Set

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

Installation, Operating and Maintenance Manual

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Solution F2. Fire Alarm Control Panels one step ahead.

MINERVA MX. 800 Series Ancillary Equipment

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Intelligent Security & Fire Ltd

Excel-EN Conventional Fire Control Panel

Industries. As a premier global manufacturing company, we believe that great brands are

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Sonos Sounder Beacon (DC)

Addressable and Conventional Fire Protection

Multi-Gas-Controller MGC2

Application, Installation, Operation & Maintenance Manual

Interface Modules for SENTRI

DB5 Intrinsically Safe Sounder Type DB-5

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

A Guide To BS Understanding the selection, spacing and siting of detectors

LF /2. Fire Alarm Control Panel. Features:

Door Release Power Supply

Vega Devices.

SAFE AREA AUDIBLE & VISUAL SIGNALLING PRODUCTS

ELECTRONIC SOUNDER STROBE Model : AVD-C407

TX6831 Data Sheet. Features. Benefits

Transcription:

Intellia Bases and Beacon Bases The Base and Beacon Base are a local-area alarm devices designed for indoor use. They can be connected only to detection systems using Intellia detectors and FX control panels with appropriate software. The Intellia series of products are all compatible with the ALC-board of an FX-panel. Ancillary Base SI-10 The Ancillary Base is a local-area sounder designed for indoor use. It can be connected only to detection systems using Intellia detectors and FX control panels with appropriate software. The sounder incorporates a base into which a loop powered beacon or an Intellia detector is fitted. It is powered by the control panel via the loop wiring to which it is connected. Since the sounder is switched by the remote indicator output of the associated detector or beacon no remote indicator facility is available. A guaranteed sound output of 85dB(A) at 1 metre is achieved at a current consumption of only 3mA. The sounder generates very low current noise so that up to 126 sounders may be connected to a loop. In order to determine the exact number in a loop please use the Loop Calculator program. The Ancillary Base responds to signals from the associated detector or beacon. It does not have an address of its own. Integrated Base s SI-20 and SI-30 The sounders offer: - two tone ranges 55 75dB and 75 91dB - synchronisation of alert and evacuate tones - individual and group addressing - available with or without built-in isolator - unique acoustic self-test - short circuit isolator (SI-20) The low tone range is useful in areas such as hospitals where a fire alert is initially intended to warn staff only. The sounder is set to the high range for general use. The acoustic self-test means that the sounder listens to itself when it is switched on. If no sound is detected a fault signal is transmitted when the sounder is polled. The integrated base sounder responds to its own individual address set with a DIL switch. Ancillary Base lectrical considerations The Ancillary Base SI-10 is loop-powered and requires no external power supply. It operates at 17 28V DC. Tone frequency and volume control The sounder produces an uninterrupted alternating tone of 990Hz for 0.5 seconds and 630Hz for 0.5 seconds. The volume control can be used to adjust the sound steplessly from 70dB(A) to 85dB(A). It should be noted that these sounders do not have a synchronisation feature or pulsed tone. Integrated Base D01513/GB0 06-2006

Integrated s Beacon Bases The Loop-powered Beacon Base combines a sounder with a beacon and a detector base in one unit. The beacon is activated whenever the sounder is active an cannot be controlled separately. The Loop-powered Beacon Base With short circuit isolator has a yellow LB which illuminates through the moulding if a short circuit is detected on the loop wiring. The acoustic self-test means that the sounder listens to itself when it is switched on. If no sound is detected a fault signal is transmitted when the sounder is polled. The integrated base responds to its own individual address set with a DIL switch. Picture The products offer: - two tone ranges 55 75dB and 75 91dB - individual and group addressing - available with or without built-in isolator - unique acoustic self-test - short circuit isolator (SI-60) The low tone range is useful in areas such as hospitals where a fire alert is initially intended to warn staff only. The sounder is set to the high range for general use. Integrated Beacon Base Technical data Description Ancillary Base SI-10 The Ancillary Base responds to signals from the associated detector or beacon. It does not have an address of its own. Integrated Base SI-20, SI-30 Individual address is set with DIL switch. Operating voltage 17 28V DC (polarity sensitive) Protocol pulses 5 9V Current consumption at 24V DC quiescent sounder operated <100 µa 3 ma <1.2 ma 5 ma <300 µa 8 ma Sound pressure level at 1m 85dB(A) 55-78dB, 75-91dB, Frequency 990Hz for 0.5s, 630Hz for 0.5s IP rating IP23D (to BS N 60529:1992) IP21D (standard version) Integrated Beacon Bases SI-60, SI-70 Individual address is set with DIL switch. Operating temperature 20 C to +60 C Max. relative humidity 0 95% (no condensation) Dimension (diameter x height) 115 x 38mm Weight 140g Material Polycarbonate Contacts Stainless steel Stainless steel. Solid or stranded cables max. 2.5mm² Colour White Fixing centres 50 60mm SI-10: 0672 8010 SI-20: 0672 8020 SI-60: 0672 8060 smi product code (short circuit isolator) (short circuit isolator) SI-30: 0672 8030 SI-70: 0672 8070 (no isolator) (no isolator) Installation Accessories smi product code Spacer for surface installation 0672 8093 Red cap 0672 8091 White cap 0672 8092 D01513/GB0 2 06-2006

Connection diagrams Ancillary Base SI-10 No field wires are connected to this = Loop + = arth (screen) continuity and are polarity sensitive D01513/GB0 3 06-2006

Integrated Base s SI-30 and SI-20 = Loop + = arth (screen) continuity = Remote LD + = Remote LD Group address setting = Remote LD and are polarity sensitive OUT = Loop out OUT = Loop in = Loop + = arth (screen) continuity = Remote LD + = Remote LD = Remote LD Group address setting and are polarity sensitive OUT IN D01513/GB0 4 06-2006

Integrated s Beacon Bases SI-70 and SI-60 = Loop + = arth (screen) continuity = Remote LD + = Remote LD Group address setting = Remote LD and are polarity sensitive OUT = Loop out OUT = Loop in = Loop + = arth (screen) continuity = Remote LD + = Remote LD = Remote LD Group address setting and are polarity sensitive OUT IN D01513/GB0 5 06-2006