Ventilation Dryer for Hydraulic Units

Similar documents
Assembly and Maintenance manual according to regulation DIN 82079

Assembly and Maintenance manual according to regulation DIN DV TB 310-MA, DV TB 330-MA DV TB 510-MA, DV TB 530-MA DV TB 560-MA

Assembly and Maintenance manual according to regulation DIN 82079

Material Safety Data Sheet according to Regulation (EC) No. 1907/2006. Composition/Information on Ingredients

Continental and Lycoming typically rate their

ECON Pellet Dryer S+L. for drainage and drying of synthetic granules and recycling material

Adsorption dryer SDAT

AIR SENTRY DESICCANT BREATHERS

The leader in gas dehydration & filtration

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers

Operation Manual 322 KL

Industrial Processing Solutions

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

KRAL Screw Pumps. L Series.

Boreas DV DV AB / WB

IDU22C, 22C1, 37C, 37C1, 55C, 75C

HL Hydraulik GmbH SCHRUPP GAS DRYER STATIONS GAS DRYER STATIONS. Optional with Bypass.

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

Waveguide Dehydrators

When considering the purchase of a walk-in you most likely will be looking for the following things.

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Rail vehicles without compressed air? Practically inconceivable!

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

Operating instructions Open two-stage compressor FZ 16

Pelletizing System Options for Extrusion

DESICCANT AIR DRYERS. BD + CD + CD series

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

A-DRY Heatless adsorption compressed air dryers

Transformer Breathers

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

Proportioners for Stationary Extinguishing Systems

Safety vacuum drying oven for flammable solvents

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Installation, Operation and Maintenance Manual

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Heated tools. Semiconductor equipment

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Selection and projecting of compressed air generation in railbound vehicles

Hot Water Circulator Pump LRP

Product Overview: SOMOS dryer type series Manfred Horsch - Head of Sales Area South/D-A-CH Region, West Europe

Spare parts list. Hydraulic compactor RC

NEWGATE TECHNOLOGIES, INC.

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

DESICCANT AIR DRYERS. BD + CD + CD series

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

ultra.dry heat regenerated adsorption dryer

BINDER Scientific Product Catalog

DRYAIRE DESICCANT SYSTEM MODEL 6760

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

Vacuum drying oven for non-flammable solvents

Güntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions!

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

The Flush Kit: The perfect companion to Harvest Right home freeze dryers. The Flush Kit. User s Manual

Installation and Maintenance Instructions

Filters & Centrifugal Separators

BC BRONCOS AIR CONDITIONING UNIT

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Technology for Vacuum Systems. Instructions for use

Thermal Oil Heating System. Heat Recovery System. Member of the

Installation plan: PG Mat. no Version 00 US

VC-1, VC-1-SL, VC-2-L, VC-2-SL

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064

AlarmLine Addressable Linear Heat Detector

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

Adsorption Dryers for Compressed Air

Desiccant Breathers: A Front Line Defense in the War on Contamination

Operation Refilling and Maintenance Manual SFS-10. Hatsuta Seisakusho Co. Ltd. SFS-10-E1404-(A-012)

SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES SENSING BUMPERS INTERFACE CONTROLLERS LIGHT CURTAINS CUSTOM DESIGNS

New standard in compressed air treatment, providing Energy Savings up to 99%

Operating instructions for semi-hermetic motorcompressors

Air treatment solutions. Aftercoolers & condensate treatment

HYGROPHIL H process hygrometer

Enzo Concealed Shower Mixing Valve

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

V80-H Multistage Pump Instruction Manual

AND NATURAL GAS DRILLING AND PRODUCTION

Aerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)

Site Specifications for the. INDUSTREX M37 Plus NDT Filmprocessor

TF Series With SECOPAC LS

MULTI-STAGE COMPONENT CLEANING MACHINES

P3X Series Membrane dryers

Module 7: Air Supply System

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

GAW - WCCAP recommendation for aerosol drying

Programme. High-Pressure Water Jet Technique

JONES Membrane Vent is designed to protect enclosures and devices from particles, water, oil, and other

UltraDry s Features and Benefits

50 - WMS // Straight resistance thermometers with a metal thermowell and a built-in measurement insert

Operating Instructions

Freezertech Horizontal Plate Freezers Engineered for capacity

Transcription:

Ventilation Dryer for Hydraulic Units When using hydraulic units, humid air is sucked in by pressure equalization with the environment, which condensate when the temperature drops below the dew point. The use in high humidity and temperature fluctuations can lead to condensation damage. Rapid aging of the hydraulic oil, the degradation of additives and the promotion of corrosion are only a few possible damages. To prevent damage caused by condensation, the use of a ventilation dryer is a very good measure. The incoming supply air is dried and thus a strong reduction in the water content and the dew point is achieved. While a well-designed ventilation dryer protects the hydraulic unit very efficiently, handling is very easy. The color change of the silica gel from orange to green indicates the status of the adsorber. GIEBEL FilTec has developed the VARIO and VENT series for protection of hydraulic power packs. GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 13.12.2016 1/5

Use of the series VARIO Special feature: Stable aluminum valve part, large frost-proof aluminum valves, pre-filter disc for dust, oil master for outflowing air Areas of application: Longer maintenance intervals, larger tank volumes, dusty ambient conditions, high air throughputs, high oil mist emissions Advantages: Disadvantages: Excellent air drying, no sticking or freezing of the valves, separation of oil aerosols, easy handling without tools, long maintenance intervals due to high quantity of drying agent Higher construction by valve part Use of the series VENT Special feature: Smaller dimensions, easy assembly, larger choice of sizes Areas of application: Restricted installation conditions, smaller tank volumes, lower air flow rates Advantages: Disadvantages: Reasonable purchase costs, low installation dimensions Valves not suitable for very dusty or very cold environments, no adequate oil separation during oil mist emission GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 13.12.2016 2/5

VENT PA-D VENT PA-R VARIO PA-D VARIO PA-R VARIO MA VARIO ME Valves Refillable Use according to ATEX 2014 Offshore / Marine suitable Tank volume / Air flow rate 0 50 l up to 10l/min, max. 30l/min 0 50 l up to 10l/min, max. 30l/min 50 100 l up to 20l/min, max. 100l/min 50 100 l up to 20l/min, max. 100l/min vv 120-PA vv 140-PA vv 200-PA vv 220-PA vv 130-PA vv 150-PA vv 210-PA vv 230-PA 100 600 l up to 40l/min, max. 260l/min 100 600 l up to 80l/min, max. 490l/min 600 1800 l up to 110l/min, max. 610l/min 600 1800 l up to 160l/min, max. 930l/min 1800 3600 l up to 210l/min, max. 1250l/min vv 300-PA vv 310-PA DV 300-PA DV 310-PA DV 310-MA DV 310-ME vv 320-PA vv 330-PA DV 320-PA DV 330-PA DV 330-MA DV 330-ME vv 500-PA vv 510-PA DV 500-PA DV 510-PA DV 510-MA DV 510-ME vv 520-PA vv 530-PA DV 520-PA DV 530-PA DV 530-MA DV 530-ME DV 550-PA DV 560-PA DV 560-MA DV 560-ME up to 260l/min, max. 1450l/min up to 410l/min, max. 2000l/min up to 530l/min, max. 2000l/min DV 730-MA DV 760-MA DV 790-MA DV 730-ME DV 760-ME DV 790-ME GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 13.12.2016 3/5

Flange with sieve, sealing and screws Installation of an adsorber on standard bolt circle 73mm according to DIN 24557 Filling adapter with bolt circle 73mm or thread connection 40mm filling opening, without disassembling the adsorber Sidestream adapter with bolt circle 41,3mm, 73mm or thread Filter system for the preparation of oil in the side stream, no additional opening necessary Pressure display with bolt circle 73mm or thread connection For the visual display of a blocked filter from 80mbar negative pressure Assembly tube Straight or as Z form If space is tight for flexible mounting of an adsorber Wall bracket With or without stainless steel hose and oil sight glass It is also possible to install an adsorber on remote buildings GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 13.12.2016 4/5

Areas of application for GIEBEL Adsorber are Floodgate & canal in steel water construction Conveyors in mining and opencast mining Machines for pulp and paper production Flight and driving simulators Work equipment on rail vehicles Offshore and marine technology Horizontal tunnel boring machines Injection molding machines Presses and rolling machines and many more GIEBEL FilTec GmbH Web www.giebel-adsorber.de Email info@giebel-adsorber.de Tel +49 (0) 7946 944401-0 13.12.2016 5/5