Domestic Pump Condensate Transfer Equipment

Similar documents
Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

Hoffman Specialty Pump Products

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

BuildingName The Description of the Project P DOCUMENTS

Custom Design TYPE CS

SECTION STEAM CONDENSATE PUMPS

SECTION STEAM CONDENSATE PUMPS

SECTION HEATING BOILER FEEDWATER EQUIPMENT

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

PIONEERS IN AIR VACUUMS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Condensate Boiler Feed Water Make-Up

Custom Design TYPE SHM Steel Horizontal Make-up Boiler Feed Pumps and Custom Design TYPE SHEM. BULLETIN 107 Revised 5/17

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

5. CONDENSATE PUMPS/UNITS

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Packaged Semi-Instantaneous Steam Fired Water Heater

.005 ATMOSPHERIC DEAERATOR

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

SECTION STEAM CONDENSATE PUMPS

DEAERATORS .005 ATMOSPHERIC DEAERATOR

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

.03 ATMOSPHERIC DEAERATOR

Deaerator. Specifications

Goulds Large Capacity, Single Stage, Double Suction Pump

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

TYPE.005 DA-STP TYPE.005 DA-STP-2T. Spray Tray Deaerating Pressurized Boiler Feed Pumps. and. when separate surge tank is utilized

Water Piping and Pumps

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

MARLOW PUMPS RECIRCULATION

Full-line Product Overview

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

High Capacity Instantaneous Steam Fired Water Heater

TECHNICAL. Series 18. Pump Packages

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Stainless Steel Condensate Return Units

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

TYPE LF/LC/LCV END SUCTION PUMPS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

470 Series Stamped Stainless Steel Pumps

Silhouette. Feedwater Heater. Boiler Feedwater

4600 SERIES. Technical Specifications. Condensate Units - Steel Tank. Features

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

CombiBloc Close-coupled centrifugal pumps

Industrial. Solutions brands you trust. Product Overview

Packaged Steam Fired Water Heater

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Design and Construction Standards SECTION PLUMBING EQUIPMENT

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

SECTION PLUMBING EQUIPMENT

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

SERIES ES BASE MOUNTED TURBINE PUMPS

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Wilo IL Vertical Split-Coupled Inline Pumps

Semi-Instantaneous Indirect Fired Water Heater

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

TYPE.005 DA-2C. Deaerating Boiler Feed Pumps. SHIPCO Deaerators can save you money!!! BULLETIN 149 Revised 8/09

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

FLANGE-MOUNT CENTRIFUGAL PUMPS

Series 1140 and 1141 Temperature Regulators

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

MCV - MCH - MCHZ Multistage pumps

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

dualarm Vertical In-Line Pumps

SECTION PLUMBING EQUIPMENT

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

Standard Features. Performance/Capacities

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

Documento Descargado desde:

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

DUPLEX CONDENSATE TANK SYSTEM

TYPE VL/VLS VERTICAL INLINE PUMPS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Domestic Pump Vacuum and Boiler Feed Units Series VCMD TM INSTRUCTION MANUAL DN0137 REVISION F

380 Series Multi-Stage Centrifugal Pumps

KRAL Screw Pumps. L Series.

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Hard-hitting Contenders In HVAC Fluid Handling Solutions

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

Transcription:

Bulletin S-944L Domestic Pump Condensate Transfer Equipment CONDENSATE RETURN UNITS BOILER FEED UNITS LOW NPSH PUMPS VACUUM HEATING UNITS INDUSTRIAL VACUUM UNITS www.domesticpump.com

Condensate Return Units Series CC Series CS Series CED Series CB Series CC 150,000 sq. Ft. EDR. Receivers sized from 6-250 gallon (23-946 liters). The cast iron receiver includes a 20 year warranty against corrosion. CC units are available in either simplex or duplex design. Receivers have a low height NPT inlet for easy return line piping and a separate NPT overflow that can be used as a secondary vent. All simplex units include a two pole float switch. Duplex units include float switches (a mechanical alternator is available). All pumps are bronze fitted with bronze case wear rings and stainless steel shafts. Pumps are available in 3500 or 1750 RPM. (See bulletin S215) Maximum discharge pressure is 90 psi (621 kpa). Maximum pump temperature is *200 F (93 C) *Specific duty points can be rated up to 209 F (98 C) requiring only 2 NPSH. Contact your local ITT HVAC Representative for more details. Series CS 150,000 sq. Ft EDR. Steel receivers sized from 6-250 gallon (23-946 liters). Galvanized or stainless steel receivers are available. CS units are available in either simplex or duplex design. Receivers have a low height NPT inlet for easy return line piping and a separate NPT overflow that can be used as a secondary vent. All simplex units include a two-pole float switch. Duplex units include float switches (a mechanical alternator is available). All pumps are bronze fitted with bronze case wear rings and stainless steel shafts. Series B35 pumps can be provided for 210 F (99 C) applications. Stainless Steel pumps are available. Pumps are available in 3500 or 1750 RPM. Maximum discharge pressure (using Centriflo or Series B pumps) 90 psi (621 kpa) Maximum seal temperature is 250 F (121 C) Maximum pump temperature is 200 F (93 C) with Centriflo Pumps (210 F (99 C) with Series B pumps). Series CED 550,000 sq. Ft. EDR The CED offers a flexible solution for handling condensate in commercial applications. The CED has an elevated receiver that is available in Steel, Galvanized Steel, Epoxy Lined Steel, ASME construction or Stainless Steel. The receiver is sized for 5 minute net storage, with a fabricated steel base with suction piping and isolation valves. The CED is offered with either the Centriflo or Series B pumps, including the B35, HB35 and HB17 styles. The B pumps have a suction inducer to create a positive pressure at the centrifugal impeller. The feature lowers the NPSH requirement of the pump. The CED is available in simplex and duplex configurations. Additional pumps are available on request. All simplex units include a two-pole float switch. Duplex units include float switches (a mechanical alternator is available). All pumps are bronze fitted with bronze case wear rings and stainless steel shafts (See Bulletin S240). Stainless Steel pumps are available. Maximum discharge pressure (using Centriflo or Series B pumps) 175 psi (1207 kpa) Maximum pump temperature is 212 F (100 C) with Series B pumps. Series CB 90,000 sq. Ft. EDR. The CB is designed for systems with low return lines. This condensate unit features the B-35 pumps which has a suction inducer to create a positive pressure at the centrifugal impeller thus guaranteeing low NPSH pump requirements. The CB units require only 2 NPSH and can pump condensate up to 210 F (99 C) at sea level. Series CB units include cast iron receivers, sized from 6-250 gallon (23-946 liters). The cast iron receiver includes a 20 year warranty against corrosion. CB units are available in either simplex or duplex design. Receivers have a low height NPT inlet for easy return line piping and a separate NPT overflow that can be used as a secondary vent. All simplex units include a two-pole float switch. Duplex units include float switches (a mechanical alternator is available). All pumps are bronze fitted with bronze case wear rings and stainless steel shafts. (See bulletin S225) Maximum discharge pressure 100 psi (690 kpa) Maximum pump temperature is 210 F (99 C)

Condensate Return Units Series CBE Series CU Series CBE 135,000 sq. Ft. EDR. Series CBE receivers are elevated 24 (0.6M) above the floor on a welded steel stand. These units are recommended for high temperature condensate applications where the height of the return lines permit their use. This condensate unit features the B-35 pumps which have a suction inducer to create a positive pressure at the centrifugal impeller. This feature lowers the NPSH requirement of the pump. The CBE units require only 2 NPSH and can pump condensate up to 212 F (100 C) at sea level. Series CBE units include cast iron receivers, sized from 6-250 gallon (23-946 liters). The cast iron receiver includes a 20 year warranty against corrosion. CBE units are available in either simplex or duplex design. Receivers have a low height NPT inlet for easy return line piping and a separate NPT overflow that can be used as a secondary vent. All simplex units include a two-pole float switch. Duplex units include float switches (a mechanical alternator is available). All pumps are bronze fitted with bronze case wear rings and stainless steel shafts. (See bulletin S225) Maximum discharge pressure 100 psi (690 kpa) Maximum pump temperature is 212 F (100 C) Series CU Below grade condensate return units for systems up to 90,000 sq. Ft. EDR. This unit includes 24 diameter cast iron receiver or 18, 30 36, 42 and 48 diameter epoxy coated steel receivers designed for installations with low or below grade return lines. The receiver is sized for 1 minute net storage with a depth of 36 or 48. Pumps are pre-selected to deliver 1 GPM per every 1000 EDR or 2 times the system return rate. The pump(s) are mounted to a steel cover plate that is bolted to the receiver. The pump bearings are carbon graphite for improved abrasion and wear resistance. The mechanical seal can be replaced without removing the pump from the receiver. The condensate level in the receiver is monitored by a heavy duty two-pole float switch. These units can be designed for vacuum service with vacuum tight construction. (See bulletin S230) Maximum discharge pressure 50 psi (621 kpa) Standard temperature rating is 200 F (93 C) Maximum of 209 F (98 C) on specific duty points. Series CHD 550,000 sq. Ft. EDR The CHD offers a flexible solution for handling condensate in commercial applications. The CHD has a floor mounted receiver that is available in Steel, Galvanized Steel, Epoxy Lined Steel, ASME construction or Stainless Steel. The receiver is sized for 5-minute net storage. The CHD is offered with either the Centriflo or B35 pump styles. The B pumps have a suction inducer to create a positive pressure at the centrifugal impeller. The feature lowers the NPSH requirement of the pump. The CHD is available in simplex and duplex configurations. Additional pumps are available on request. All simplex units include a two-pole float switch. Duplex units include float switches (a mechanical alternator is available). All pumps are bronze fitted with bronze case wear rings and stainless steel shafts (See Bulletin S240). Stainless Steel pumps are available. Maximum discharge pressure (using Centriflo or Series B pumps) 90 psi (621 kpa) Maximum pump temperature is 210 F (99 C) with Series B pumps. Series CHD HIGH TEMPERATURE CONDENSATE Series SP (not shown) Pumpless condensate return units for high temperature returns. SP units use high pressure steam or air as the motive force to return high temperature condensate. Single phase electric or pneumatic controls are required. The receivers are ASME code stamped. SP packages are available in 10 different sizes for capacities up to 60,000 lbs/hr. (See bulletin S270) Maximum discharge pressure 100 psi (1207 kpa) Maximum temperature is 338 F (121 C)

Boiler Feed Units Series CM Series CBEM Series CMHD Series CMED Series CMU Series CBM Series CM (or CSM not shown) Boiler feed units for systems up to 650 BHP; Series CM units include low inlet, durable cast iron receivers for maximum corrosion resistance. Series CSM units include low inlet, rectangular steel receivers. Galvanized or Stainless Steel CSM receivers are available. Units are available in simplex and duplex configurations. CM and CSM units include a float switch and solenoid valve with "Y" strainer to add make up water on low level. Pumps are Centriflo Series C35 or C17. CSM units may be provided with Series B-35 pumps. Stainless Steel pumps are available. Maximum discharge pressure is 90 psi (621 kpa) with Centriflo pumps. Maximum pump temperature is *200 F (93 C) with Centriflo pumps Specific duty points can be rated up to 209 F (98 C) require only 2 NPSH. Contact your local ITT HVAC Representative for more details. CSM units with B-35 pumps can be rated for 210 F (99 C) Series CBM Boiler feed units for systems up to 600 BHP. The CBM receivers have a low height NPT inlet for systems with low return lines and a separate NPT overflow that can be used as a secondary vent. This boiler feed unit features the B-35 pump which has a suction inducer to create a positive pressure at the centrifugal impeller thus guaranteeing low NPSH pump requirements. The CBM unit requires only 2 NPSH and can pump condensate up to 210 F (99 C) at sea level. CBM units are available in either simplex or duplex design. All pumps are bronze fitted with bronze case wear rings and stainless steel shafts. The Series CBM includes a float switch and solenoid valve with Y strainer to add make-up water on low level. (See bulletin S120) Maximum discharge pressure 100 psi (690 kpa) Maximum pump temperature is 210 F (99 C) Series CBEM Boiler feed units for systems up to 600 BHP. Series CBEM receivers are elevated 24 (0.6M) above the floor on a welded steel stand. These units are recommended for high temperature condensate applications where the height of the return lines permit their use. This boiler feed unit features the B-35 pumps which have a suction inducer to create a positive pressure at the centrifugal impeller thus guaranteeing low NPSH pump requirements. The CBEM units requires only 2 NPSH and can pump condensate up to 212 F (100 C) at sea level. CBM units are available in either simplex or duplex design. All pumps are bronze fitted with bronze case wear rings and stainless steel shafts. The Series CBEM includes a float switch and solenoid valve with Y strainer to add make-up water on low level. (See bulletin S120) Maximum discharge pressure 100 psi (690 kpa) Maximum pump temperature is 212 F (100 C) Series CMHD Large boiler feed units for systems up to 1895 BHP (or larger on request), Series CMHD units include cylindrical steel tanks with dished heads. Galvanized, Epoxy Lined, ASME construction or Stainless Steel tanks are available. The tanks are sized for 10-minute net storage of system water requirements. Tanks also include inlet cascade baffle, floor supports lifting lugs, gauge glass, dial thermometer and low-level cut-off switch. The CMHD is offered with either the Centriflo or Series B35 centrifugal pumps. The B-35 pumps have a suction inducer to create a positive pressure at the centrifugal impeller. This feature lowers the NPSH requirement of the pump. Stainless steel pumps are available. The Series CMHD includes a float switch and solenoid with "Y" strainer to add make up water on low lever. (See Bulletin S140) Maximum discharge pressure (using Centriflo or Series B pumps) 100 psi (690 kpa) Maximum pump temperature is 210 F (99 C) with Series B35 pumps. Series CMED Large boiler feed units for systems up to 1895 BHP (or larger on request), Series CMED units include elevated cylindrical steel tanks with dished heads. Galvanized, Epoxy Lined, ASME construction or Stainless Steel tanks are available. The tanks are sized for 10-minute net storage of system water requirements, elevated on a fabricated steel base with suction piping and isolation valves. Tanks also include inlet cascade baffle, floor supports lifting lugs, gauge glass, dial thermometer and low-level cut-off switch. The CMED is offered with the Centriflo or Series B35, HB35, HB17, DB, or DB-F centrifugal pumps. The B pumps have a suction inducer to create a positive pressure at the centrifugal impeller. This feature lowers the NPSH requirement of the pump. Stainless steel pumps are available. The Series CMED includes a float switch and solenoid with "Y" strainer to add make up water on low lever. (See Bulletin S150) Maximum discharge pressure (using Centriflo or Series B35 pumps) 100 psi (690 kpa). Higher discharge pressures are available with alternative pumps. Consult your local ITT HVAC Representative for more details. Maximum pump temperature is 212 F (100 C) with Series B35 pumps. Series CMU Below grade boiler feed return units for systems up to 580 BHP. This unit includes a cast iron or epoxy coated steel receiver designed for installations with low or below grade return lines. The receiver is sized for 10 minutes net storage to absorb surges in rate of condensate return. Pumps are pre-selected to deliver two times the system condensate return rate. The pump/s are mounted to a steel cover plate that is bolted to the receiver. The pump bearings are carbon graphite for improved abrasion and wear resistance. The pump mechanical seal can be replaced. The CMU includes a float-switch operated solenoid make-up valve assembly to maintain a minimum water level in the receiver. These units can be designed for vacuum service with vacuum tight construction. (See bulletin S230) Maximum discharge pressure is 50 psi (621 kpa). Standard temperature rating is 200 F (93 C) Maximum of 212 F (100 C) on specific duty points.

Vacuum Heating and Industrial/Clinical Vacuum Units Series VLR Series VL Series VCD Series MJ VACUUM HEATING UNITS Series VLR Series VLR vacuum heating units provide fast, even distribution of steam through out the steam heating system. Units sized for systems up to 20,000 EDR. The VLR receiver is separated into two chambers, the upper chamber holds the recirculated water that is pumped through the multi-jet nozzle and venturi creating the vacuum. The lower chamber acts as condensate accumulator and is under the same vacuum as that maintained in the return piping. The result is a compact, economical design. The VLR is available in simplex or duplex configuration. For older systems with higher air leakage rates, special capacity units are available to provide additional air removal capacity. (See bulletin S310) Maximum temperature is 180 F (82 C) Pressures to 40 psi (276 kpa) Series VL Series VL vacuum heating units provide fast, even distribution of steam throughout the steam heating system. The VL is designed for systems from 25,000 to 65,000 EDR. The compact design has a cast iron receiver designed for low returns. The unit recirculates water that is pumped through the multi-jet nozzle and venturi creating the vacuum. When the condensate level in the receiver raises, a discharge valve opens allowing the recirculated water to discharge from the VL unit back to the condensate return system. The VL unit is available in standard capacity and special capacity for increased air capacities and higher vacuums for older systems. (See bulletin S320) Maximum temperature is 180 F (82 C) Pressures to 40 psi (276 kpa) Series VCD (or VCDS not shown) The series VCD vacuum heating unit is designed for large systems through 150,000 sq. Ft. EDR. The VCD include durable cast iron receivers, warranted for 20 years against failure due to corrosion. The VCDS includes an economical steel receiver alternative. These units feature individually sized and separately controlled vacuum producing pumps and condensate handling pump. These units are available with one vacuum and one condensate pump (simplex), one vacuum and two condensate pumps (semiduplex) or two vacuum pumps and two condensate pumps (duplex). Optional temperature controls may be added to stop the vacuum pumps or add cold water when high water temperatures are sensed. (See Bulletin S330) Maximum temperature is 180 F (82 C) Pressures to 75 psi (517 kpa) Series VCMD Series VCMD is a combination vacuum and boiler feed unit that offers a wide selection of cast iron, steel, and underground boiler feed receivers in conjunction with the dependable water jet vacuum units. The vacuum unit can be mounted on the boiler feed unit to conserve floor space or be furnished separately. Individually sized and separately controlled vacuum and water pumps permit maximum flexibility to met the required design conditions. (See bulletin S160) Series VCMD Series WSC & WSS INDUSTRIAL/CLINICAL VACUUM UNITS Series MJ The Series MJ vacuum pump is ideal for hospital, laboratory, and industrial applications. The MJ uses the multi-jet vacuum producers to provide smooth reliable operation for years. A centrifugal pump circulates water through the multijet nozzle and venturi to create the vacuum. The water is discharged into a separation chamber and reused by the pump. Units available in simplex and duplex configuration. (See bulletin S500) Capacities to 344 CFM Vacuum level to 28 Hg. MAKE-UP SUPPLY UNITS Series WSC or WSS Series WSC and WSS are water make-up supply units. Both units include a positive air-gap to eliminate the likelihood of backflow and possible contamination of city water supply. These units supply a detached, central, make-up supply reservoir for deaerators, boiler feed units, process loads, cooling systems and towers. The WSC unit has a cast iron receiver. The WSS has a fabricated steel receiver. A float switch operated solenoid make-up valve supplies water to the receiver through the air gap fitting. Available in either simplex or duplex configuration with Centriflo pumps. Available in 3500 RPM (Series C35) and 1750 RPM (Series C17) Capacities to 600 GPM (37.8 l/s) Pressures to 100 psi (690 kpa)

Centrifugal Pumps Series C35 & C17 Series B35 Centriflo Series C35 or C17 These pumps are the heart of Domestic Pump condensate-handling equipment. Designed for the rigorous demands of this service, Centriflo pumps require a lower NPSH than conventional pumps. Vertical mounting of the pump saves floor space and gets the motor up above dirt and water. For more information see bulletin S410C. Standard features include: Cast iron, bronze fitted with stainless steel shaft Carbon/ceramic mechanical seals designed for 250 F (121 C) Available in 3500 RPM (Series C35) and 1750 RPM (Series C17) Capacities to 600 GPM (37.8 l/s) Pressures to 100 psi (690 kpa) Series HB35 & HB17 Series B35 2' NPSH The original low NPSH pump, specifically designed for high temperature pumping. The axial flow propeller provides the necessary NPSH to the impeller, assuring cavitation fee operation. For more information see bulletin S430. Standard features include: Rated for 210 F (99 C) condensate in vented heightless applications Cast iron, bronze fitted with stainless steel shaft Carbon/ceramic mechanical seals designed for 250 F (121 C) Capacities to 150 GPM (9.5 l/s) Pressures to 100 psi (690 kpa) Series HB35 & HB17 2 NPSH End-suction pump with axial flow propeller for low NPSH applications. These are moderate pressure at high volume pumps. (See bulletin S430) Rated for 210 F (99 C) condensate in vented heightless applications Cast iron, bronze fitted with stainless steel shaft Carbon/ceramic mechanical seals designed for 250 F (121 C) Capacities to 350 GPM (9.5 l/s) 1750 RPM Pressures to 100 psi (690 kpa) 3500 RPM Series DB Series DB-F Series DB 2 NPSH The DB is a close coupled pump with two centrifugal impellers back-to-back. Placement of the impellers balances the axial thrust and opposed discharges balance the radial thrust. The mechanical seal operates between the stages to prevent excessive wear. (See bulletin S431) Rated for 210 F (99 C) condensate in vented heightless applications Cast iron, bronze fitted with stainless steel shaft Carbon Tungsten Carbide mechanical seals designed for 250 F (121 C) Capacities to 350 GPM (9.5 l/s) Pressures to 250 psi (690 kpa) Series DB-F 2 NPSH Base mounted, back pull out design with flexible couple permits ease of service. Coupling shielded by a dual rated, ANSI B15.1, Section 8 and OSHA 191.219 compliant coupling guard and containing viewing windows for inspection of the coupling. This pump has two centrifugal impellers, back to back. Placement of the impellers balances the axial thrust and opposed discharges balances the radial thrust. The mechanical seal operates between the stages to prevent excessive wear. (See Bulletin S431) Rated for 210 F (99 C) condensate in vented heightless applications. Cast iron, bronze fitted pump with stainless steel pump shaft. Carbon Tungsten Carbide mechanical seals designed for 250 F (121 C) Capacities to 350 GPM (9.5 l/s) Pressures to 250 psi (690 kpa)

State of the Art Facilities Factory Testing All built-to-order products are tested as a complete unit to meet customer's duty-point. Electrical and mechanical components are adjusted and tested for trouble-free installation. Manufactured in an ISO 9001 certified, state of the art facility. Little Red Schoolhouse A Leader Educating the Industry ITT is known throughout the HVAC business as the industry s educator. Our Little Red Schoolhouse, a completely equipped learning center, has trained more than 60,000 engineers, contractors and installers in the proper design, installation and maintenance of HVAC systems.

ITT offers the most complete line of products needed for steam systems. The line includes: Domestic Pump and Hoffman Pump: Provide the full line of condensate transfer equipment including condensate transfer units, boiler feed units, vacuum heating units, clinical vacuum units and low NPSH pumps. Condensate Transfer Units Hoffman Specialty: Offers a complete line of steam traps, regulators and accessories. Bell & Gossett Heat Transfer: Designs and manufactures an extensive line of heat exchangers for HVAC and industrial applications. Products include U-Tube, Straight Tube (with fixed or floating tube sheet), Brazed Plate and Gasketed Plate Heat Exchangers. Steam Traps Heat Exchangers Regulators ITT 8200 N. Austin Avenue Morton Grove, IL 60053 Phone: 847/966-3700 FAX:847/966-2106 www.domesticpump.com TUV CERT DIN ISO 9001 ISO 9001 Certified ITT R&CW Canada 55 Royal Road Guelph, Ontario N1H 1T1, Canada Phone: 519/821-1900 FAX: 519/821-2569 www.ittfpc.com THE ITT ENGINEERED BLOCKS SYMBOL AND ENGINEERED FOR LIFE ARE REGISTERED TRADEMARKS OF ITT CORPORATION. 2007 PRINTED IN U.S.A