Rosemount 4500 Hygienic Pressure Transmitter. Start

Similar documents
Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Annubar Flowmeter Series

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 3051S MultiVariable Transmitter

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 752 Fieldbus Remote Indicator

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 702 Wireless Discrete Transmitter

Quick Start Guide , Rev. BB February Rosemount 1495 Orifice Plate Rosemount 1496 Orifice Flange Union

Rosemount 1595 Conditioning Orifice Plate

Rosemount 3051 Pressure Transmitter

Model 144H. Product Data Sheet , Rev DB February Content

J. Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter with HART Protocol.

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 644H and 644R Smart Temperature Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters

Configuration Data Sheet

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Rosemount 3100 Series Ultrasonic Level Transmitters

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Rosemount 8800D Series Vortex Flowmeter

Sanitary Pressure Transmitter

Rosemount 3144P Temperature Transmitter with HART Protocol

Rosemount 3490 Series

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2160 Wireless Vibrating Fork Level Switch

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 3051HT Hygienic Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Rosemount 3051SFC Compact Orifice Flowmeter

Absolute and Gage Pressure Transmitter

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Rosemount 3051SFP Proplate Flowmeter

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Rosemount 2051G Pressure Transmitter

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Rosemount 248 Temperature Transmitter

Rosemount 8800D Series Vortex Flowmeter. Quick Start Guide , Rev FE October 2018

Fisher LCP100 Local Control Panel

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Mobrey MCU900 Series Universal Control Unit

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2100 Series

Rosemount 2090F Hygienic Pressure Transmitter

Emerson Wireless SmartPower Solutions

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Druck DPI 705/DPI 705 IS Series

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 3051CFP Integral Orifice Flowmeter

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

Quick Start Guide , Rev HA January Rosemount 248 Temperature Transmitter

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Rosemount 3051L Level Transmitter

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Rosemount 8732E Magnetic Flowmeter System with Profibus PA digital fieldbus (Transmitter and Sensor)

Analog Room Pressure Monitor RPC Series

Rosemount 248 Temperature Transmitter

Rosemount Compact Orifice Flowmeter Series

Operating Instructions Edition 02/2007

Advanced HART Diagnostic Suite

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 248 Temperature Transmitter

Rosemount 3051CFC Compact Flowmeter

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Rosemount 644 Temperature Transmitter

Rosemount 8600 Series Vortex Flowmeter. Quick Start Guide , Rev EB April 2018

NT DUAL CHANNEL DISPLAY. User Guide

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Rosemount 8732E Magnetic Flowmeter System (Transmitter and Sensor)

Figure 1 DirectLine DL423 Sensor. Description, continued

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Rosemount 752 Remote Indicator

Software Version 2.01 LEVEL MONITOR MODEL 220

Sensor Wiring Instructions and Approval Drawings

Transcription:

Quick Installation Guide June 2007 Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Set the Switches Step 3: Connect Wiring and Power Up Step 4: Install the LCD Meter Step 5: Configure the Transmitter Step 6: Trim the Transmitter Safety Instrumented System Power Up Transmitter Check Process Connections Confirm Configuration Loop Test End R 37-01 www.rosemount.com 00825-0100-4809[

Rosemount 4500 Quick Installation Guide June 2007 2007 Rosemount Inc. All rights reserved. All marks property of owner. Rosemount Inc. 8200 Market Boulevard Chanhassen, MN USA 55317 T (US) (800) 999-9307 T (Intnl) (952) 906-8888 F (952) 949-7001 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947/65 6777 0743 Emerson Process Management GmbH & Co. OHG Argelsrieder Feld 3 82234 Wessling Germany T 49 (8153) 9390 F 49 (8153) 939172 Beijing Rosemount Far East Instrument Co., Limited No. 6 North Street, Hepingli, Dong Cheng District Beijing 100013, China T (86) (10) 6428 2233 F (86) (10) 6422 8586 IMPORTANT NOTICE This installation guide provides basic guidelines for the Rosemount 4500. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting, or installations. Refer to the Rosemount 4500 reference manual (document number 00809-0100-4027) for more instruction. The manual and this QIG are also available electronically on www.rosemount.com. 2

Quick Installation Guide June 2007 Rosemount 4500 STEP 1: MOUNT THE TRANSMITTER Electronics Housing Provide 0.75 inches (19 mm) of clearance for units without an LCD display. Three inches of clearance is required for cover removal if a meter is installed. Mount the Transmitter The Rosemount 4500 is designed to be mounted directly to a process pipe or vessel using a standard sanitary fitting. The transmitter is available with either a 1.5 or 2-inch Tri-Clamp connection or a fractional line fitting. When installing the transmitter to the sanitary fitting it is important to use the proper sanitary clamp and gasket (user-supplied). Check the clamp and gasket specifications before installing. Refer to Table 2 for a list of standard sanitary clamps, their respective maximum pressure ranges, and the recommended torque to be applied when mounting. Figure 1. Rosemount 4500 Mounting Configuration Using a Sanitary Fitting DETAIL OF SANITARY CONNECTION 1.5 or 2-in. Tri-Clamp Connection B A User Supplied Gasket and Clamp Table 1. Connection Size Description Connection Size in (mm) A B 1 1 /2 inch Tri-Clamp 1.50 (38) 1.99 (50) 1.71 (43) 2 inch Tri-Clamp 2.00 (51) 2.52 (64) 2.22 (56) Fractional Line Fitting 1.50 (38) 1.99 (50) 1.50 (38) Table 2. Standard Sanitary Clamp Models psi @ 70 F Clamp Model (kpa @ 21 C) psi @ 250 F (kpa @ 121 C) Recommended Torque 13 MHHM 1.5-inch 450 (3 103) 250 (1 724) 25 in-lb (2.8 N m) 13 MHHM 2-inch 500 (3 448) 250 (1 724) 25 in-lb (2.8 N m) 13 MHHS 1.5-inch 600 (4 138) 300 (2 069) 25 in-lb (2.8 N m) 13 MHHS 2-inch 550 (3 793) 275 (1 896) 25 in-lb (2.8 N m) 13 MHP 1.5-inch 1500 (10 345) 1200 (8 276) 20 ft-lb (27 N m) 13 MHP 2-inch 1000 (6 896) 800 (5 517) 20 ft-lb (27 N m) 3

Rosemount 4500 Quick Installation Guide June 2007 STEP 2: SET SWITCHES Figure 2. Switch configuration LCD Switches LOI Switches ALARM SECURITY SPAN ZERO Security -LOOP +LOOP Security Alarm Alarm Slide the security and alarm switches into the preferred position by using a small screwdriver. Slide the security and alarm switches into the preferred position by using a small screwdriver. NOTE If alarm and security adjustments are not installed, the transmitter will operate normally with the default alarm condition alarm high and the security off. HART Communicator Fast Keys 1, 3, 4, 5 USAGE NOTE The HART Communicator can be used to configure the security on and off. If the transmitter contains the D1 option, the switch will override any software configuration. AMS Right click on the device and select Methods, then Device Configuration, then Write Protect from the menu. 1. Enter write protect setting, click Next. 2. Click Next to acknowledge setting has changed. If hardware adjustments are activated, click Next to acknowledge the Switch option detected, function disabled, write protect unchanged screen. If the hardware adjustments are activated, the write protect will not configure. 3. Click Finish to acknowledge the method is complete. 4

Quick Installation Guide June 2007 Rosemount 4500 STEP 3: CONNECT WIRING AND POWER UP Wiring for HART Protocol NOTE Use shielded twisted pairs to yield best results. To ensure proper communication, use 24 AWG or larger wire, and do not exceed 5000 feet (1 500 meters). Figure 3. HART Terminal Blocks -LOOP ALARM SECURITY +LOOP SPAN ZERO -LOOP +LOOP To make connections, perform the following procedure: 1. Remove the housing cover. 2. Connect the positive lead to the terminal marked (+) and the negative lead to the terminal marked (pwr/comm ). 3. Tighten cord grip to avoid moisture accumulation in the terminal compartment. Signal Wiring Grounding Do not run signal wiring with power wiring or near heavy electrical equipment. Ground the signal wiring at any one point on the signal loop, or leave it ungrounded. The negative terminal of the power supply is a recommended grounding point. Power Supply 4 20 ma Transmitters The dc power supply should provide power with less than two percent ripple. Total resistance load is the sum of resistance from signal leads and the load resistance of the controller, indicator, and related pieces. Note that the resistance of intrinsic safety barriers, if used, must be included. NOTE A minimum loop resistance of 250 ohms is required to communicate with a HART Communicator. If a single power supply is used to power more than one 4500 transmitter, the power supply used, and circuitry common to the transmitters, should not have more than 20 ohms of impedance at 1200 Hz. 5

# % & ABC DEF GHI JKL MNO PQRS TUV WXYZ, ( ) + * / Rosemount 4500 Quick Installation Guide June 2007 Grounding Transmitter Case Always ground the transmitter case in accordance with national and local electrical codes. The most effective transmitter case grounding method is a direct connection to earth ground with minimal impedance. Methods for grounding the transmitter case include: Internal Ground Connection: The Internal Ground Connection screw is inside the electronics housing. The screw is identified by a ground symbol ( ), and is standard on all 4500 transmitters. Hook-up Bench Hook-up Connect the bench equipment as shown in Figure 4, and turn on the HART Communicator by pressing the ON/OFF key or log into AMS. The HART Communicator or AMS will search for a HART-compatible device and indicate when the connection is made. If the HART Communicator or AMS fail to connect, it indicates that no device was found. If this occurs, refer to Section 5: Troubleshooting in the manual (document number 00809-0100-4027). Figure 4. PlantWeb Wiring Bench Hook-Up ALARM SECURITY SPAN ZERO -LOOP +LOOP COMM # % & ABC DEF GHI JKL MNO PQRS TUV WXYZ, ( ) + * / Field Hook-up Figure 5 illustrates wiring loops for a field hook-up with a HART Communicator or AMS. Signal point may be grounded at any point or left ungrounded. Figure 5. PlantWeb Wiring Field Hook-Up ALARM SECURITY SPAN ZERO -LOOP +LOOP COMM 6

Quick Installation Guide June 2007 Rosemount 4500 STEP 4: INSTALL THE LCD METER Transmitters ordered with the LCD display will be shipped with the meter installed. Installing the meter on an existing 4500 transmitter requires a small instrument screwdriver and the meter kit. The optional LCD display can be rotated in 90-degree increments. Use the following procedure to install the LCD display: 1. IF the transmitter is installed in a loop, THEN secure the loop and disconnect power. 2. Remove the transmitter cover. 3. Engage the four-pin connector from the LCD display into the four-pin receptacle. Tighten screws to secure the LCD. Note the following LCD temperature limits: Ambient 32 to 140 F (0 to 60 C) Storage 22 to 185 F ( 30 to 85 C) Process Temperature Limits 32 to 400 F (0 to 204 C) Horizontal Mount For process temperatures above 293 F (145 C), derate ambient temperature by 41 F (5 C) for every 50 F (10 C) increase in process temperature. Top Mount For process temperatures above 266 F (130 C), derate ambient temperature by 39 F (4 C) for every 50 F (10 C) increase in process temperature. 7

Rosemount 4500 Quick Installation Guide June 2007 STEP 5: CONFIGURE THE TRANSMITTER A check ( ) indicates the basic configuration parameters. At minimum, these parameters should be verified as part of the configuration and startup procedure. Table 3. HART Fast Key Sequence Function HART Fast Key Sequence Alarm Level Configuration 1, 4, 2, 7, 7 Alarm and Saturation Levels 1, 4, 2, 7 Analog Output Alarm Direction 1, 4, 2, 7, 6 Analog Output Trim 1, 2, 3, 2 Burst Mode On/Off 1, 4, 3, 3, 3 Burst Options 1, 4, 3, 3, 4 Damping 1, 3, 6 Date 1, 3, 4, 1 Descriptor 1, 3, 4, 2 Digital To Analog Trim (4-20 ma Output) 1, 2, 3, 2, 1 Field Device Information 1, 4, 4, 1 LCD Display Configuration 1, 3, 7 Loop Test 1, 2, 2 Lower Sensor Trim 1, 2, 3, 3, 2 Message 1, 3, 4, 3 Number of Requested Preambles 1, 4, 3, 3, 2 Pressure Alert Configuration 1, 4, 3, 5, 3 Poll Address 1, 4, 3, 3, 1 Poll a Multidropped Transmitter Left Arrow, 3, 1, 1 Re-mapping 1, 4, 3, 6 Rerange- Keypad Input 1, 2, 3, 1, 1 Saturation Level Configuration 1, 4, 2, 7, 8 Scaled D/A Trim (4 20 ma Output) 1, 2, 3, 2, 2 Scaled Variable Configuration 1, 4, 3, 4, 7 Self Test (Transmitter) 1, 2, 1, 1 Sensor Information 1, 4, 4, 2 Sensor Temperature 1, 1, 4 Sensor Trim 1, 2, 3, 3 Sensor Trim Points 1, 2, 3, 3, 5 Status 1, 2, 1, 2 Tag 1, 3, 1 Temperature Alert Configuration 1, 4, 3, 5, 4 Transfer Function (Setting Output Type) 1, 3, 5 Transmitter Security (Write Protect) 1, 3, 4, 5 Units (Process Variable) 1, 3, 2 Upper Sensor Trim 1, 2, 3, 3, 3 Zero Trim 1, 2, 3, 3, 1 8

Quick Installation Guide June 2007 Rosemount 4500 STEP 6: TRIM THE TRANSMITTER Transmitters are shipped fully calibrated per request or to the factory default of full scale (span = upper range limit). Zero Trim A zero trim is a single-point adjustment used for compensating mounting position and line pressure effects. When performing a zero trim, ensure that the equalizing valve is open and all wet legs are filled to the correct level. If zero offset is less than 3% of true zero, follow the Using the HART Communicator instructions below to perform a zero trim. If zero offset is greater than 3% of true zero, follow the Using the Transmitter Zero Adjustment Button instructions below to rerange. If hardware adjustments are not available, see the 4500 Reference Manual (document number 00809-0100-4027) to perform a rerange using the HART Communicator. Using the HART Communicator HART Fast Keys Steps 1, 2, 3, 3, 1 1. Equalize or vent the transmitter and connect HART communicator. 2. At the menu, input the HART Fast Key sequence. 3. Follow the commands to perform a zero trim. Using the Transmitter Zero Adjustment Button Push and hold the zero adjustment button for at least two seconds but no longer than ten seconds. Junction Box Span Zero 9

Rosemount 4500 Quick Installation Guide June 2007 Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota, USA Ordinary Locations Certifications As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). N0 Factory Mutual (FM) Ordinary Location; Canadian Ordinary Location CE Marking 3-A Symbol Authorization #876 EHEDG Type EL (1) Certified to meet Hygienic Equipment Design Criteria of Document 8 per TNO evaluation #V6069 and certificate #C05-6288 European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at www.rosemount.com. A hard copy may be obtained by contacting our local sales office. ATEX Directive (94/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) Rosemount 4500 Pressure Transmitters- Sound Engineering Practice Electro Magnetic Compatibility (EMC) (89/336/EEC) All Models: EN 50081-1: 1992; EN 50082-2:1995; EN 61326-1:1997/ A1 1998 Industrial Hazardous Locations Certifications North American Certifications Factory Mutual (FM) Approvals I5 Intrinsically Safe for use in Class I, II, III, Division 1, Groups A, B, C, D, E, F, and G; Temperature Code T4 (T amb = 0 to 60 C); Intrinsically Safe for use in Class I, Zone 0 AEx ia IIC T4 (T amb = 0 to 60 C); Non-incendive for Class I, Division 2, Groups A, B, C, and D; When connected in accordance with Rosemount drawing 04500-5001; Enclosure Type 4X For entity parameters see control drawing 04500-5001; (1) Not applicable to 1.5-in. fractional line version. 10

Quick Installation Guide June 2007 Rosemount 4500 Canadian Standards Association (CSA) Approvals (Pending) I6 Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Temperature Code T3C (T amb = 0 to 60 C); Intrinsically Safe for use in Class I, Zone 0 Ex ia IIC T4 (T amb = 0 to 60 C); When connected in accordance with Rosemount drawing 04500-5002; Enclosure Type 4X For entity parameters see control drawing 04500-5002; European Certifications I1 ATEX Intrinsic Safety Certificate No. Baseefa05ATEX0091X ATEX Marking: II 1 G EEx ia IIC T4 (T amb = 60 C) IP66 1180 Input Parameters: U i = 30V I i = 200mA P i = 1.0W C i = 0nF L i = 2.4µH Special Conditions For Safe Use (x) The plastic meter cover does not meet the surface resistivity requirements and, to avoid electrostatic charging, it must not be rubbed or cleaned with solvents. N1 ATEX Type n (Pending) Certificate No. Baseefa05ATEX0092X ATEX Marking: II 3 G EEx na nl IIC T5 (T amb = 60 C) U i = 42.4V MAXIMUM IP66 Special Conditions For Safe Use (x) The plastic meter cover does not meet the surface resistivity requirements and, to avoid electrostatic charging, it must not be rubbed or cleaned with solvents. 11

Rosemount 4500 Quick Installation Guide June 2007 NOTES 12