Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Similar documents
Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

R4H4. Product Specifications

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

A 14 SEER Heat Pump with R---410A Refrigerant Series

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. Efficiency

R4H4. Product Specifications

Product Data. Efficiency. S S Reliability

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. Efficiency

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

N4H4. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data. Efficiency

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

WCH5**4. Product Specifications

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Advance Product Data

697C (60 HZ) Sizes 018 thru 060

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. Efficiency

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

N4A6. Product Specifications

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. Efficiency

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data INDUSTRY LEADING FEATURES / BENEFITS

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

PAJ3. Product Specifications

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

R 410A Ducted Horizontal Air Conditioner

PAR5. Product Specifications

Installation Instructions

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

WJH4 Product Specifications

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Advance Product Data

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. Fig. 1 - Unit 50VR -A

Commercial High-Efficiency Condensing Units

Advance Product Data

Advance Product Data

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. Efficiency

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

WPH4 Product Specifications

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Product Data. Fig. 1 - Unit 50VG -A

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Transcription:

(60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1 --- 1/2 to 5 Nominal Tons) Product Data The Outdoor Section of Split-System Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. With EER ratings up to 9.5, this heat pump system provides economy of operation through energy conservation when used with components designated by the manufacturer. The recovers heat for indoor comfort from outdoor air during the heating season and, by automatically reversing the refrigerant system, removes indoor heat and excess humidity during the cooling season. All models are listed with UL (U.S. and Canada). FEATURES AND BENEFITS Electrical Range All units are offered in 208/230v single phase. Three-phase units are available from 036 through 060 sizes in 208/230v. Wide Range of Sizes All sizes of the are offered in single phase 208-230v. The 030 through 060 models are offered in 208/230v 3 phase. Unit Design All units are equipped with totally enclosed fan motors for greater reliability under adverse weather conditions. The large, wrap -around coil uses copper tube epoxy coated enhanced aluminum fin and is designed for optimum heat transfer and corrosion protection during heating and cooling. The vertical air discharge carries the sound and air up and away from adjacent patio areas and foliage. Coil can be cleaned with a common garden hose. WeatherArmort Cabinet A weather protective cabinet of pre -painted steel is protected underneath by a zinc galvanized coating for a finish that will last for many years. All screws on cabinet exterior are coated for a long -lasting, rust -resistant, quality appearance. Compressor Designed specifically for heat pump duty, with energy efficiency during heating and cooling operation. Each compressor is hermetically sealed against contamination to assure long life and dependable performance; compressors are also externally mounted on rubber isolators for quiet operation. For improved serviceability, all models are equipped with a compressor terminal plug. Continuous compressor operation is approved down to -30_F (-34.4_C) in the heating mode, and down to 55_F (12.8_C) in the cooling mode (unless equipped for low -ambient operation). Compressor Protection Each compressor is protected with internal temperature - and current -sensitive overloads. Reliable standard components Includes a suction -tube accumulator that reduces the amount of liquid refrigerant that reaches the compressor; a lowpressure switch to stop the compressor if refrigerant charge is lost; a crankcase heater on all 3 -phase units (except 030 size) to keep compressor oil warm and free of refrigerant for maximum lubricity; an internal compressor relief valve for high -pressure protection. 3-phase monitor board (scroll compressor models) Control board that monitors the electrical phase and prevents compressor operation if wired incorrectly.

FEATURES AND BENEFITS (CONT.) External Service Valves Service valves are brass, front seating type. The has sweat field connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. Easy Serviceability One panel provides access to electrical controls. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil and compressor. All models are equipped with a compressor terminal plug. Discharge Muffler Minimizes low frequency sound and pressure pulsation generated by compressor discharge gas. Defrost Control Board Incorporates a defrost relay, defrost timer, and low -voltage terminations. The defrost control is a time and temperature initiation/termination control which includes 3 field -selectable time periods of 30, 60, and 90 minutes. PRODUCT NUMBER NOMENCLATURE 018 X 3 A A 10 SEER Electric Heat Pump Nominal 018 --- 1 --- 1/2 Ton 024 --- 2 Tons 030 --- 2 --- 1/2 Tons 036 --- 3 Tons 042 --- 3 --- 1/2 Tons 048 --- 4 Ton 060 --- 5 Ton Series Packaging X =Export =Standard Electrical Supply 3=208/230---1 5=208/230---3 ISO 9001:2000 REGISTERED PHYSICAL DATA UNIT SIZE 018---3A 024---3A 030---3A, 5A 036---3A,5A 042---3B,5A 048---3B,5A 060---3A,5A OPERATING WEIGHT (lb/kg) 127/57.6 143/64.9 157/71.2 176/79.8 195/88.5 219/99.3 237/107.5 COMPRESSOR TYPE Recip Scroll Recip Scroll REFRIGERANT R --- 22 Control Piston Charge (Lb/kg) @15 Ft./4.6m 4.25/1.9 4.63/2.1 5.19/2.4 6.38/2.9 7.88/3.6 9.38/4.3 10.5/4.8 COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty (CFM/L/S) 1700/802 2500/1180 3000/1415 3300/1557 Motor HP 1/12 1/4 Motor RPM 1100 1125 1100 COND COIL Copper Tube, Aluminum Plate Fin Face Area sq ft / sq m 9.11/.85 12.42/1.15 14.8/1.37 18.5/1.72 22.40/2.08 Fins per in./25.4 mm 20 25 20 25 Rows 1 Circuits 2 3 4 5 VALVE CONNECTION Sweat Vapor (in./mm)ld 5/8/15.88 3/4/19.05 7/8/22.23 Liquid (in./mm)ld 3/8/9.53 REFRIG. TUBES*(in./mm) OD Vapor (0---50 ft/0---15.24m Tube) 5/8/15.88 3/4/19.05 7/8/22.3 Vapor (Max Diameter for Long Line Applications) 3/4/19.05 7/8/22.23 1---1/8/28.58 Liquid (0---50 ft./0---15.24 m/ Tube Length) 3/8/9.53 Liquid (For Long Line Applications) 3/8/9.53 * For tubing sets between 50 and 175 ft (15.24 and 53.34 m) horizontal and/or 20 ft (6.1 m) vertical differential, consult Residential Split Systems Long --- Line Application Guideline. NOTE: See unit Installation Instructions for proper installation. 2

ELECTRICAL DATA UNIT SIZE V/PH OPER VOLTS* COMPRESSOR Max Min LRA RLA FAN FLA MCA 60 C MIN WIRE SIZE 75 C MIN WIRE SIZE 60 C MAX LENGTH ft (m) 75 C MAX LENGTH ft (m) MAX FUSE** OR CKT BKR AMPS 018---3A 48.0 9.0 0.5 11.8 14 14 66 62 20 024---3A 61.0 11.3 0.5 14.6 14 14 53 50 20 030---3A 73.0 13.8 1.4 18.7 14 14 41 39 30 036---3A 208---230/1 253 197 86.0 17.2 1.4 22.9 12 12 55 52 35 042---3B 109.0 18.3 1.4 24.3 10 10 67 63 40 048---3B 137.0 19.2 1.4 25.4 8 10 107 66 40 060---3A 148.0 30.8 1.4 39.9 8 8 75 70 60 030---5A 68.0 9.0 1.4 12.7 14 14 41 39 15 036---5A 78.0 11.3 1.4 15.5 14 14 50 50 20 042---5A 208/230/3 253 187 88.0 16.4 1.4 21.9 12 12 66 63 30 048---5A 91.0 12.9 1.4 17.5 14 14 51 48 25 060---5A 137.0 20.7 1.4 27.3 10 10 82 78 35 * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. { If wire is applied at ambient greater than 30 C, consult Table 310---16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic---sheathed cable (NM), trade name ROMEX, shall be that of 60 C conductors, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (non---plated), 60 or 75 C insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). } Length shown is as measured 1 way along wire path between the unit and service panel for a voltage drop not to exceed 2%. ** Time --- delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- RatedLoadAmps NOTES: 1. Control circuit is 24v on all units and requires external power source. 2. Copper wire must be used from service disconnect to unit. 3. All motors/compressors contain internal overload protection. METERING DEVICE UNIT SIZE --- VOLTAGE, SERIES OUTDOOR PISTON PISTON* REQUIRED SUB---COOLING _F (_C) 018---3A 42 55 12 (6.7) 024---3A 49 63 12 (6.7) 030---3A, 5A 55 70 12 (6.7) 036---3A, 5A 57 70 14 (7.8) 042---3B, 5A 63 78 16 (8.9) 048---3B, 5A 70 86 15 (8.3) 060---3A, 5A 76 96 10 (5.6) * Piston listed is for any approved non ---capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. A -WEIGHTED SOUND POWER (dba) UNIT SIZE STANDARD TYPICAL OCTAVE BAND SPECTRUM (db, without tone adjustment) RATING (db) 125 250 500 1000 2000 4000 8000 18---3A 78 49.5 58.0 66.5 69.5 67.0 66.5 59.5 24---3A 78 50.5 59.0 64.5 68.0 67.5 67.5 61.5 30---3A,5A 80 57.5 64.5 68.5 72.5 72.5 70.0 64.0 36---3A,5A 81 60.5 67.5 73.0 76.0 73.0 69.5 63.5 42---3B,5A 80 59.0 65.0 70.5 75.5 72.0 69.5 64.0 48---3B,5A 80 54.5 63.5 69.5 75.0 71.0 70.0 67.5 60---3A,5A 80 56.0 64.5 73.0 74.5 71.0 71.0 63.0 3

ACCESSORIES ORDERING NUMBER DESCRIPTION KAATD0101TDR Time--Delay Relay All Sizes KSALA0201R22 Low--Ambient Pressure Switch All sizes KSALA0401AAA*{ MotorMaster Low--Ambient Controller Sizes 018 030; 036 (3A, 5A); 042 (3B, 5A); 048 (3B, 5A); 060 (3A, 5A) HC34GE232 (RCD) Ball Bearing Fan Motor Sizes 018, 024 HC40GE232 (RCD) Ball Bearing Fan Motor Sizes 030 (3A, 5A); 036 (3A, 5A); 042 (3B, 5A); 048 (3B, 5A); 060 (3A, 5A) KAAFT0101AAA} Evaporator Freeze Thermostat All Sizes KH0101AAA} Isolation Relay All Sizes KSACY0101AAA Cycle Protector All Sizes KSAHS0901AAA Start Assist Capacitor and Relay Size 030 (3A) KSAHS2101AAA Start Assist Capacitor and Relay Sizes 024 (3A); 036 (3A) KSAHS2001AAA Start Assist Capacitor and Relay Size 018 (3A) KSAHS1501AAA Start Assist Capacitor and Relay Sizes 042 (3B); 048 (3B) KSAHS1601AAA Start Assist Capacitor and Relay Size 060 (3A) KAACS0201PTC Start Assist PTC Sizes 018 030 (3A); 036 (3A); 042 (3B); 048 (3B); 060 (3A) Standard Crankcase Heater All Three Phase KAACH1001AAA Crankcase Heater 018 036 (3A) KAACH1201AAA Crankcase Heater Sizes 042 (3B); 048 (3B); 060 (3A) KSASH0601COP Sound Hood Size 042 (3B, 5A) KSASH2001BRL Sound Hood Sizes 018 --030 (3A) KSASH2101COP Sound Hood Sizes 048 (3B, 5A); 060 (3A, 5A) KHAOT0301FST Outdoor Thermostat All Sizes KHAOT0201SEC Secondary Outdoor Thermostat All Sizes KSATX0601HSO** TXV (Hard Shutoff) Sizes 018 042 KSATX0701HSO** TXV (Hard Shutoff) Size 048 KSATX1001HSO** TXV (Hard Shutoff) Size 060 KHATX0201RPB TXV (RPB) Size 018 KHATX0301RPB TXV (RPB) Size 024 KHATX0401RPB TXV (RPB) Size 030 KHATX0501RPB TXV (RPB) Sizes 036, 042 KHATX0601RPB TXV (RPB) Sizes 048 KHATX0701RPB TXV (RPB) Sizes 060 KHAHI0101HPS High--Pressure Switch All Sizes P504-8083S (RCD) Filter Drier Bi--Flow Sizes 018 036 P504-8163S (RCD) Filter Drier Bi--Flow Sizes 042 060 KHALS0401LLS Liquid--Line Solenoid Valve (LSV) All Sizes KAACF1001MED Coastal Filter Kit 018 030 KAACF1101LRG Coastal Filter Kit 036 060 * Isolation relay required. { Fan motor with ball bearings required. } Use with low---ambient controller. ** Addition of these accessories requires capacitor and relay compressor start assist on all single---phase reciprocating compressor applications. ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE PKG. TSTATCCPRH01---B* TSTATCCPHH01---B* TSTATCCPHP01---B TSTATCCNHP01---C TSTATCCSHP01 TSTATCCBHP01* ---B TSTATXXSEN01---B** TSTATXXNBP01 TSTATXXPBP01 TSTATXXSBP01 TSTATXXBBP01 TSTATXXCNV10{ TB --- PHP --- 01 DESCRIPTION Thermidistatt Control Non---Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) HybridHeatt (Dual Fuel) Thermostat Auto Changeover, 7---Day Programmable, F/ C, Includes Outdoor Sensor (TSTATXXSEN01---B) Thermostat Auto Changeover, 7---Day Programmable, F/ C, 2 ---Stage Heat, 1 ---Stage Cool Thermostat Auto Changeover, Non---Programmable, F/ C, 2 ---Stage Heat, 1 ---Stage Cool Standard Programmable Thermostat Manual Changeover, 5---2 Day Programmable, F/ C, 1 ---Stage Heat/ 1 ---Stage Cool Builder s Thermostat Heat Pump, Non---Programmable, F/ C, 2---Stage Heat, 1---Stage Cool, Manual Changeover Outdoor Air Temperature Sensor Backplate for Non---Programmable Thermostat Backplate for Programmable Thermostat and Thermidistatt Control Backplate for Standard Programmable Thermostat Backplate for Builder s Thermostat Thermostat Conversion Kit (4 to 5 Wire) 10 Pack Base Series Programmable HP Stat TB --- NHP --- 01 Base Series Non---programmable HP Stat * Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non---programmable air conditioner version and builder;s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat. { Thermostat conversion kit is a 24---vac accessory that can turn a 4---wire thermostat application into a 5---wire application. This kit can also be used to re place a broken thermostat wire, or add an extra wire when needed. The outdoor air temperature sensor is included with the Thermidistat Control and HybridHeatt (dual fuel) thermostat. 4

ACCESSORY USAGE GUIDELINE ACCESSORY REQUIRED FOR LOW---AMBIENT APPLICATIONS (Below 55 F / 12.78 C) REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 Ft. / 24.38 m) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) Accumulator No No No Ball Bearing Fan Motor Yes{ No No Compressor Start Assist Capacitor and Relay Yes{ Yes No Crankcase Heater Yes{ Yes No Evaporator Freeze Thermostat Yes{ No No Isolation Relay Yes{ No No Liquid Line Solenoid Valve No See Long Line Application Guideline No Motor Master Control or Low---ambient Pressure Switch Yes{ No No Support Feet Recommended No Recommended * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. vertical (6.09 m) differential, refer to Residential Split System Long Line Application Guideline. { Required for Low---Ambient Controller MotorMasterr Control only. Accessory Description and Usage (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Required on all units when MotorMasterr is used. 2. Compressor Start Assist - Capacitor and Relay Start capacitor and relay gives a hard boost to compressor motor at each start up. Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Compressor Start Assist PTC Type Solid state electrical device which gives a soft boost to the compressor at each start -up. Suggested in installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 5. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5 -minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 6. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze -up conditions. Required when low ambient kit has been added. 7. High Pressure Switch A high pressure switch that protects unit against excessive pressure. Required in all heat pumps operated in dual fuel applications. 8. Isolation Relay An SPDT relay which switches the low -ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. Required in all heat pumps where low ambient kit has been added. 9. Liquid -Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline. 10. Low -Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low -ambient temperatures down to 0_F when properly installed. A Low -Ambient Pressure Switch or MotorMasterr Low -Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 5

Accessory Description and Usage (Listed Alphabetically) - CONTINUED 11. MotorMasterr Low -Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20_F (-28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± 5.5_C). A MotorMasterr Low Ambient Controller or Low -Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 12. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Suggested for all Carrier thermostats listed in this publication. 13. Outdoor Thermostat An SPDT temperature -actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-selected set point. Electric supplemental heat applications in non -variable speed indoor units when electric heat staging is desired. Some local codes may require limiting the heating head pressure in the vapor line in some applications. 14. Secondary Outdoor Thermostat An SPDT temperature -actuated switch which turns on third -stage of supplemental electric heaters when outdoor air temperature drops below the second -stage set point. Outdoor thermostat applications where electric heater is capable of 3 -stage operation. 15. Snow Stand Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base. Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 16. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level up to 2 dba. Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3.05 m) apart. Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 17. Thermostatic Expansion Valve (TXV) Bi-Flow A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Required in all heat pump applications 18. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below. Accessory required to meet ARI rating, where indoor not equipped. 6

DIMENSIONS (ENGLISH) 7

DIMENSIONS (S.I.) 8

BALANCE POINT WORKSHEET (ENGLISH) 048---3B,5A 042---3B,5A 9 OUTDOOR TEMPERATURE, _F

BALANCE POINT WORKSHEET (S.I.) 20 060-3A,5A FA4CNF(F,C)060 048-3B,5A FA4CN(F,C)048 042-3B,5A FA4CN(F,C)042 15 036-3A,5A FA4CN(F,C)036 030-3A,5A FA4CN(F,C)030 10 BUILDING HEAT LOSS, KW UNIT INTEGRATED HEATING CAPACITY, KW 10 024-3A FA4CN(F,C)024 018-3A FA4CN(F,C)018 5 BASED ON ENT. AT 21ºC ANDATRATEDCFM - 20-10 0 10 20 OUTDOOR TEMPERATURE, _C

COMBINATION RATINGS* OUTDOOR UNIT SIZE --- SERIES UNIT NOMINAL --- FLOW CFM L/S Rated BTUH Cooling @ 95 F (35 C) kw kw Rated EER Heating High --- Temp @ 47 F (8 C) Low --- Temp @ 17 F ( --- 8 C) Rated BTUH kw kw Rated BTUH kw FB4BN(F,L)024 600 280 18000 5.27 1.89 9.50 18000 5.27 1.70 11400 3.34 1.52 018---3A FA4CN(F,C)018 600 280 18000 5.27 1.89 9.50 18000 5.27 1.70 11500 3.37 1.53 FA4CN(F,C)024 600 280 18200 5.33 1.92 9.50 18200 5.33 1.67 11700 3.43 1.56 FB4BN(F,L)024 800 380 22600 6.62 2.51 9.00 22800 6.68 2.09 14000 4.10 1.78 024---3A FA4CN(F,C)024 800 380 23000 6.74 2.42 9.50 23000 6.74 2.11 14000 4.10 1.78 FA4CN(F,C)030 800 380 23400 6.86 2.46 9.50 23000 6.74 2.11 14000 4.10 1.78 FB4BN(F,L)036 1000 467 29200 8.56 3.17 9.20 29200 8.56 2.76 17500 5.13 2.33 030---3A,5A FA4CN(F,C)030 1000 467 29600 8.67 3.12 9.50 29200 8.56 2.67 17500 5.13 2.33 FA4CN(F,C)036 1000 467 29600 8.67 3.18 9.30 29600 8.67 2.71 17800 5.22 2.37 FB4BN(F,L)036 1200 550 34200 10.02 3.80 9.00 36000 10.55 3.40 22000 6.45 2.93 036---3A,5A FA4CN(F,C)036 1200 550 35000 10.25 3.68 9.50 35600 10.43 3.26 21800 6.39 2.78 FA4CN(F,C)042 1200 550 35700 10.46 3.76 9.50 36300 10.64 3.32 22300 6.53 2.84 FB4BN(F,L)048 1400 653 41000 12.01 4.56 9.00 42200 12.36 3.99 27000 7.91 3.44 042---3B,5A FA4CN(F,C)042 1400 653 41000 12.01 4.56 9.00 42200 12.36 3.99 27000 7.91 3.44 FA4CN(F,C)048 1400 653 42000 12.31 4.67 9.00 42400 12.42 3.88 27000 7.91 3.44 FB4BN(F,L)048 1600 750 45500 13.33 5.06 9.00 47000 13.77 4.30 30200 8.85 4.02 048---3B,5A FB4BN(F,L)060 1600 750 46500 13.62 5.17 9.00 47500 13.92 4.35 30400 8.91 4.05 FA4CN(F,C)048 1600 750 46500 13.62 4.89 9.50 47000 13.77 4.17 30200 8.85 3.85 FA4CN(F,C)060 1600 750 47500 13.92 5.00 9.50 47000 13.77 4.17 30200 8.85 3.85 060---3A,5A FB4BN(F,L)060 2000 919 56000 16.41 6.22 9.00 58000 16.99 5.31 38500 11.28 4.90 FA4CN(F,C)060 2000 919 56500 16.55 6.08 9.30 58000 16.99 5.15 38500 11.28 4.70 * Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit. High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43 F (6_C) wb air entering outdoor unit. Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (±9_C) db 15 F (±10_C) wb air entering outdoor unit. SEER Seasonal Energy Efficiency Ratio COP Coefficient of Performance TDR Time ---Delay Relay HSPF Heating Seasonal Performance Factor EER Energy Efficiency Ratio kw 38CKC 11

DETAILED COOLING CAPACITIES* (ENGLISH) COIL CFM EWB 525 600 675 [ CONDENSER ENTERING TEMPERATURES F 75 85 95 105 115 125 [ [ [ Sens] Sens] Sens] Sens] Sens] Sens] 018--3A Outdoor Section With FA4CN(F,C)018 Indoor Section 57 16.99 16.99 1.63 16.19 16.19 1.70 15.34 15.34 1.78 14.48 14.48 1.86 13.57 13.57 1.95 12.60 12.60 2.03 62 17.89 15.87 1.65 16.83 15.34 1.72 15.80 14.80 1.79 14.70 14.21 1.87 13.59 13.59 1.95 12.60 12.60 2.03 67 20.00 13.51 1.69 18.87 13.06 1.77 17.64 12.51 1.85 16.45 12.00 1.93 15.23 11.49 2.01 13.93 10.96 2.09 72 21.82 10.94 1.72 20.96 10.63 1.81 19.87 10.21 1.90 18.57 9.69 1.99 17.21 9.17 2.08 15.85 8.67 2.17 57 17.66 17.66 1.68 16.84 16.84 1.75 15.95 15.95 1.83 15.05 15.05 1.91 14.11 14.11 2.00 13.11 13.11 2.09 62 18.34 16.88 1.69 17.22 16.31 1.76 16.17 15.71 1.84 15.07 15.07 1.91 14.10 14.10 2.00 13.11 13.11 2.09 67 20.40 14.21 1.73 19.29 13.81 1.81 18.00 13.25 1.89 16.73 12.73 1.97 15.47 12.21 2.05 14.15 11.66 2.13 72 22.06 11.25 1.76 21.30 11.02 1.85 20.25 10.66 1.94 18.96 10.17 2.03 17.51 9.61 2.12 16.11 9.10 2.21 57 18.30 18.30 1.72 17.38 17.38 1.80 16.49 16.49 1.88 15.52 15.52 1.96 14.55 14.55 2.05 13.52 13.52 2.14 62 18.68 17.70 1.73 17.57 17.14 1.80 16.49 16.49 1.88 15.51 15.51 1.96 14.54 14.54 2.05 13.51 13.51 2.14 67 20.69 14.84 1.77 19.59 14.49 1.85 18.27 13.95 1.93 16.97 13.41 2.01 15.66 12.88 2.09 14.32 12.31 2.17 72 22.18 11.50 1.79 21.51 11.36 1.89 20.49 11.02 1.98 19.24 10.58 2.07 17.77 10.03 2.16 16.31 9.50 2.25 Cooling Indoor Model *FA4CN(F,C)024 1.01 1.01 FB4BN(F,L)024 1.00 1.00 [ [ COIL CFM EWB 700 800 900 [ CONDENSER ENTERING TEMPERATURES F 75 85 95 105 115 125 [ [ [ [ [ Sens] Sens] Sens] Sens] Sens] Sens] 024--3A Outdoor Section With FA4CN(F,C)024 Indoor Section 57 22.31 22.31 2.03 21.31 21.31 2.16 20.25 20.25 2.28 19.23 19.23 2.41 18.20 18.20 2.55 17.10 17.10 2.69 62 22.95 21.37 2.05 21.67 20.69 2.17 20.44 20.01 2.29 19.24 19.24 2.42 18.19 18.19 2.55 17.10 17.10 2.69 67 25.69 18.05 2.10 24.21 17.46 2.23 22.60 16.77 2.37 21.22 16.20 2.50 19.80 15.61 2.63 18.36 15.02 2.76 72 27.97 14.36 2.15 26.89 13.98 2.29 25.50 13.47 2.44 23.81 12.84 2.59 22.22 12.25 2.73 20.71 11.70 2.88 57 23.31 23.31 2.09 22.13 22.13 2.23 21.02 21.02 2.35 19.94 19.94 2.49 18.87 18.87 2.63 17.73 17.73 2.77 62 23.65 22.86 2.10 22.21 22.00 2.23 21.02 21.02 2.35 19.94 19.94 2.49 18.87 18.87 2.63 17.72 17.72 2.77 67 26.14 19.08 2.15 24.68 18.54 2.28 23.00 17.87 2.42 21.52 17.27 2.55 20.08 16.67 2.68 18.62 16.07 2.82 72 28.28 14.82 2.19 27.25 14.54 2.34 25.94 14.11 2.49 24.28 13.53 2.64 22.57 12.90 2.79 20.98 12.33 2.93 57 24.14 24.14 2.15 22.87 22.87 2.29 21.68 21.68 2.42 20.54 20.54 2.56 19.42 19.42 2.70 18.23 18.23 2.84 62 24.17 24.17 2.15 22.86 22.86 2.29 21.68 21.68 2.42 20.53 20.53 2.56 19.42 19.42 2.70 18.23 18.23 2.84 67 26.47 20.05 2.19 25.06 19.60 2.33 23.41 18.97 2.47 21.78 18.30 2.61 20.31 17.69 2.74 18.82 17.05 2.87 72 28.48 15.27 2.24 27.50 15.05 2.39 26.26 14.73 2.54 24.62 14.17 2.69 22.86 13.54 2.84 21.17 12.95 2.99 Cooling Indoor Model *FA4CN(F,C)030 1.02 1.02 FB4BN(F,L)024 0.98 1.04 See notes on page 13 12

DETAILED COOLING CAPACITIES* (ENGLISH) CONTINUED COIL CONDENSER ENTERING TEMPERATURES F 75 85 95 105 115 125 CFM EWB Sens Sens Sens Sens Sens Sens 030--3A Outdoor Section With FA4CN(F,C)030 Indoor Section 57 28.61 28.61 2.62 27.37 27.37 2.79 26.09 26.09 2.95 24.78 24.78 3.12 23.41 23.41 3.30 21.98 21.98 3.47 875 62 29.38 27.44 2.64 27.84 26.60 2.80 26.28 25.74 2.96 24.75 24.75 3.12 23.40 23.40 3.29 21.98 21.98 3.47 67 32.79 23.14 2.69 30.98 22.39 2.87 29.09 21.59 3.05 27.34 20.86 3.22 25.54 20.11 3.39 23.65 19.34 3.55 72 35.73 18.36 2.74 34.43 17.93 2.94 32.69 17.30 3.13 30.57 16.49 3.33 28.61 15.77 3.51 26.70 15.07 3.69 57 29.83 29.83 2.70 28.43 28.43 2.87 27.10 27.10 3.04 25.73 25.73 3.22 24.30 24.30 3.39 22.79 22.79 3.57 1000 62 30.22 29.32 2.70 28.49 28.43 2.87 27.10 27.10 3.04 25.72 25.72 3.22 24.30 24.30 3.39 22.79 22.79 3.57 67 33.38 24.48 2.75 31.57 23.82 2.94 29.60 23.01 3.12 27.74 22.25 3.29 25.89 21.48 3.46 23.99 20.69 3.62 72 36.10 18.99 2.80 34.90 18.67 3.00 33.25 18.14 3.20 31.16 17.39 3.39 29.08 16.62 3.58 27.05 15.89 3.76 57 30.89 30.89 2.76 29.37 29.37 2.95 27.95 27.95 3.12 26.52 26.52 3.30 25.04 25.04 3.48 23.47 23.47 3.66 1125 62 30.93 30.93 2.76 29.36 29.36 2.95 27.95 27.95 3.12 26.51 26.51 3.30 25.03 25.03 3.48 23.47 23.47 3.66 67 33.78 25.73 2.81 32.04 25.18 3.00 29.96 24.36 3.18 28.07 23.57 3.35 26.18 22.79 3.52 24.25 21.96 3.69 72 36.34 19.56 2.86 35.20 19.34 3.06 33.64 18.90 3.26 31.59 18.22 3.46 29.35 17.41 3.65 27.29 16.68 3.83 Cooling Indoor Model *FA4CN(F,C)036 1.00 1.02 FB4BN(F,L)036 0.99 1.02 COIL CFM EWB 1050 1200 1350 [ Sens ] CONDENSER ENTERING TEMPERATURES F 75 85 95 105 115 125 [ [ [ [ [ Sens] Sens] Sens] Sens] Sens] 036--3A, 5A Outdoor Section With FA4CN(F,C)036 Indoor Section 57 33.27 33.27 3.11 31.89 31.89 3.28 30.50 30.50 3.47 29.10 29.10 3.67 27.64 27.64 3.87 26.12 26.12 4.07 62 34.36 31.64 3.13 32.69 30.67 3.30 30.96 29.75 3.48 29.27 28.79 3.67 27.62 27.62 3.86 26.11 26.11 4.07 67 38.15 26.68 3.18 36.49 25.88 3.39 34.44 25.02 3.60 32.49 24.20 3.79 30.55 23.39 3.99 28.51 22.55 4.19 72 41.45 21.04 3.24 40.37 20.67 3.47 38.63 20.09 3.69 36.41 19.26 3.92 34.25 18.46 4.13 32.15 17.68 4.35 57 34.63 34.63 3.20 33.13 33.13 3.38 31.67 31.67 3.58 30.20 30.20 3.78 28.68 28.68 3.98 27.10 27.10 4.19 62 35.30 33.75 3.20 33.48 32.67 3.40 31.71 31.71 3.58 30.19 30.19 3.78 28.67 28.67 3.98 27.09 27.09 4.19 67 38.94 28.06 3.26 37.23 27.49 3.47 35.00 26.62 3.68 33.00 25.78 3.87 31.00 24.95 4.08 28.94 24.10 4.28 72 41.81 21.71 3.31 40.86 21.50 3.54 39.26 21.00 3.77 37.15 20.29 4.00 34.81 19.40 4.23 32.61 18.61 4.45 57 35.79 35.79 3.27 34.19 34.19 3.48 32.67 32.67 3.68 31.12 31.12 3.88 29.54 29.54 4.09 27.90 27.90 4.31 62 36.07 35.48 3.28 34.24 34.24 3.49 32.66 32.66 3.68 31.12 31.12 3.88 29.54 29.54 4.09 27.90 27.90 4.31 67 39.37 29.38 3.33 37.76 28.97 3.55 35.52 28.16 3.76 33.40 27.27 3.96 31.34 26.41 4.16 29.25 25.53 4.37 72 42.05 22.23 3.38 41.18 22.19 3.61 39.67 21.81 3.85 37.64 21.19 4.08 35.21 20.30 4.31 32.95 19.49 4.53 Cooling Indoor Model *FA4CN(F,C)042 1.02 1.02 FB4BN(F,L)036 0.98 1.03 See notes on page 13 13

DETAILED COOLING CAPACITIES* (ENGLISH) CONTINUED COIL CFM EWB 1225 1400 1575 [ CONDENSER ENTERING TEMPERATURES F 75 85 95 105 115 125 [ [ [ [ [ Sens] Sens] Sens] Sens] Sens] Sens] 042--3B, 5A Outdoor Section With FA4CN(F,C)042 Indoor Section 57 38.39 38.39 3.61 37.11 37.11 3.94 35.70 35.70 4.29 34.20 34.20 4.69 32.64 32.64 5.13 30.94 30.94 5.60 62 39.87 36.08 3.64 38.27 35.24 3.98 36.56 34.36 4.33 34.71 33.38 4.71 32.84 32.32 5.14 30.95 30.95 5.60 67 43.68 30.15 3.73 42.15 29.55 4.08 40.30 28.79 4.46 38.29 27.94 4.86 36.10 27.03 5.27 33.87 26.10 5.74 72 47.00 23.81 3.82 46.01 23.54 4.18 44.43 22.98 4.57 42.46 22.26 5.00 40.18 21.37 5.46 37.65 20.43 5.92 57 39.83 39.83 3.73 38.48 38.48 4.07 37.02 37.02 4.43 35.43 35.43 4.82 33.77 33.77 5.26 32.00 32.00 5.74 62 40.68 38.39 3.74 39.08 37.52 4.09 37.35 36.54 4.45 35.47 35.47 4.82 33.76 33.76 5.26 31.99 31.99 5.74 67 44.35 31.77 3.83 42.87 31.28 4.18 41.00 30.60 4.56 38.88 29.71 4.97 36.62 28.77 5.38 34.31 27.82 5.85 72 47.38 24.51 3.91 46.54 24.40 4.28 45.05 23.93 4.67 43.10 23.27 5.10 40.83 22.47 5.56 38.25 21.50 6.06 57 40.98 40.98 3.83 39.65 39.65 4.18 38.12 38.12 4.56 36.47 36.47 4.95 34.70 34.70 5.38 32.86 32.86 5.87 62 41.36 40.39 3.84 39.74 39.74 4.18 38.12 38.12 4.56 36.46 36.46 4.95 34.69 34.69 5.38 32.85 32.85 5.86 67 44.78 33.23 3.92 43.37 32.89 4.27 41.49 32.26 4.65 39.31 31.38 5.07 37.01 30.42 5.49 34.64 29.43 5.95 72 47.59 25.12 3.99 46.85 25.14 4.36 45.46 24.80 4.76 43.54 24.22 5.19 41.26 23.45 5.66 38.65 22.49 6.16 Cooling Indoor Model *FA4CN(F,C)048 1.02 1.02 FB4BN(F,L)048 1.00 1.00 COIL CFM EWB 1400 1600 1800 57 62 67 [ CONDENSER ENTERING TEMPERATURES F 75 85 95 105 115 125 [ [ [ [ [ Sens] Sens] Sens] Sens] Sens] Sens] 048--3B, 5A Outdoor Section With FA4CN(F,C)048 Indoor Section 44.26 45.70 50.14 54.25 44.26 41.90 35.02 27.71 3.90 3.92 4.01 4.10 42.62 43.69 48.09 52.66 42.62 40.85 34.19 27.17 4.24 4.28 4.38 4.48 40.93 41.62 45.75 50.61 40.93 39.77 33.20 26.45 4.64 4.66 4.78 4.90 72 57 45.94 45.94 4.02 44.19 44.19 4.38 42.40 42.40 4.78 40.52 40.52 5.21 38.48 38.48 5.69 36.28 36.28 6.19 62 46.64 44.64 4.03 44.60 43.48 4.39 42.46 42.38 4.78 40.52 40.52 5.21 38.47 38.47 5.69 36.27 36.27 6.19 67 50.89 36.97 4.11 48.90 36.23 4.49 46.50 35.30 4.89 43.99 34.25 5.34 41.41 33.18 5.80 38.57 32.01 6.29 72 54.74 28.60 4.20 53.26 28.20 4.59 51.30 27.59 5.01 48.84 26.73 5.46 46.16 25.76 5.96 43.16 24.65 6.49 57 47.27 47.27 4.13 45.49 45.49 4.50 43.60 43.60 4.90 41.66 41.66 5.35 39.55 39.55 5.82 37.25 37.25 6.33 62 47.55 46.77 4.15 45.52 45.52 4.50 43.59 43.59 4.90 41.65 41.65 5.35 39.54 39.54 5.82 37.25 37.25 6.33 67 51.43 38.82 4.21 49.46 38.18 4.59 47.06 37.30 4.99 44.49 36.24 5.44 41.83 35.13 5.92 38.96 33.93 6.41 72 55.05 29.42 4.30 53.64 29.14 4.69 51.76 28.67 5.11 49.33 27.87 5.56 46.62 26.93 6.06 43.65 25.89 6.59 Cooling Indoor Model *FA4CN(F,C)060 1.02 1.02 FB4BN(F,L)048 0.98 1.03 FB4BN(F,L)060 1.00 1.06 See notes on page 13 39.14 39.46 43.39 48.17 39.14 38.60 32.21 25.54 5.07 5.08 5.22 5.36 37.19 37.21 40.85 45.53 37.19 37.21 31.15 24.56 5.54 5.54 5.69 5.85 35.09 35.08 38.08 42.55 35.09 35.08 30.01 23.42 6.04 6.04 6.18 6.38 14

DETAILED COOLING CAPACITIES* (ENGLISH) CONTINUED COIL CFM EWB 1750 2000 2250 [ CONDENSER ENTERING TEMPERATURES F 75 85 95 105 115 125 [ [ [ [ [ Sens] Sens] Sens] Sens] Sens] Sens] 060--3A, 5A Outdoor Section With FA4CN(F,C)060 Indoor Section 57 53.43 53.43 4.83 51.50 51.50 5.28 49.51 49.51 5.79 47.46 47.46 6.34 45.26 45.26 6.94 42.87 42.87 7.56 62 55.19 50.87 4.86 52.68 49.56 5.31 50.23 48.28 5.81 47.79 46.93 6.35 45.28 45.28 6.94 42.87 42.87 7.56 67 60.85 42.55 4.92 58.39 41.55 5.41 55.36 40.25 5.95 52.52 39.06 6.49 49.64 37.87 7.09 46.55 36.59 7.71 72 66.10 33.65 5.01 64.18 33.00 5.50 61.70 32.11 6.04 58.70 31.00 6.63 55.30 29.68 7.27 51.95 28.44 7.92 57 55.61 55.61 4.97 53.45 53.45 5.46 51.28 51.28 5.96 49.10 49.10 6.52 46.79 46.79 7.12 44.31 44.31 7.75 62 56.36 54.29 4.98 53.85 52.79 5.47 51.30 51.30 5.96 49.10 49.10 6.52 46.79 46.79 7.12 44.30 44.30 7.75 67 61.74 44.93 5.05 59.31 44.05 5.54 56.50 42.94 6.08 53.21 41.54 6.64 50.25 40.33 7.23 47.11 39.02 7.86 72 66.76 34.79 5.14 64.94 34.28 5.64 62.52 33.49 6.18 59.64 32.49 6.76 56.24 31.25 7.40 52.53 29.87 8.07 57 57.26 57.26 5.11 55.18 55.18 5.61 52.72 52.72 6.12 50.43 50.43 6.68 48.03 48.03 7.29 45.46 45.46 7.93 62 57.32 57.32 5.11 55.17 55.17 5.60 52.72 52.72 6.12 50.42 50.42 6.68 48.02 48.02 7.29 45.45 45.45 7.93 67 62.35 47.15 5.18 59.97 46.41 5.67 57.16 45.38 6.21 53.72 43.91 6.78 50.69 42.67 7.38 47.50 41.32 8.01 72 67.18 35.82 5.27 65.44 35.45 5.77 63.07 34.77 6.31 60.23 33.84 6.90 56.79 32.67 7.53 53.13 31.32 8.21 Cooling Indoor Model *FB4BN(F,L)060 0.99 1.02 NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. { and sensible capacities are net capacities. Blower motor heat has been subtracted. } Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). ** Unit kw is total of indoor and outdoor unit kilowatts. EWB --- Entering Wet Bulb 15

DETAILED COOLING CAPACITIES* (S.I.) COIL CONDENSER ENTERING TEMPERATURES C 23.89 29.44 35 40.56 46.11 51.67 CFM EWB Sens Sens Sens Sens Sens Sens 018--3A Outdoor Section With FA4CN(F,C)018 Indoor Sectione 14 4.98 4.98 1.63 4.74 4.74 1.70 4.49 4.49 1.78 4.24 4.24 1.86 3.98 3.98 1.95 3.69 3.69 2.03 250 17 5.24 4.65 1.65 4.93 4.50 1.72 4.63 4.33 1.79 4.31 4.16 1.87 3.98 3.98 1.95 3.69 3.69 2.03 19 5.86 3.96 1.69 5.53 3.83 1.77 5.17 3.66 1.85 4.82 3.52 1.93 4.46 3.37 2.01 4.08 3.21 2.09 22 6.39 3.21 1.72 6.14 3.12 1.81 5.82 2.99 1.90 5.44 2.84 1.99 5.04 2.69 2.08 4.64 2.54 2.17 14 5.18 5.18 1.68 4.93 4.93 1.75 4.67 4.67 1.83 4.41 4.41 1.91 4.13 4.13 2.00 3.84 3.84 2.09 285 17 5.37 4.95 1.69 5.05 4.78 1.76 4.74 4.60 1.84 4.42 4.42 1.91 4.13 4.13 2.00 3.84 3.84 2.09 19 5.98 4.16 1.73 5.65 4.04 1.81 5.27 3.88 1.89 4.90 3.73 1.97 4.53 3.58 2.05 4.15 3.42 2.13 22 6.46 3.30 1.76 6.24 3.23 1.85 5.93 3.12 1.94 5.56 2.98 2.03 5.13 2.82 2.12 4.72 2.67 2.21 14 5.36 5.36 1.72 5.09 5.09 1.80 4.83 4.83 1.88 4.55 4.55 1.96 4.26 4.26 2.05 3.96 3.96 2.14 320 17 5.47 5.19 1.73 5.15 5.02 1.80 4.83 4.83 1.88 4.55 4.55 1.96 4.26 4.26 2.05 3.96 3.96 2.14 19 6.06 4.35 1.77 5.74 4.24 1.85 5.35 4.09 1.93 4.97 3.93 2.01 4.59 3.77 2.09 4.20 3.61 2.17 22 6.50 3.37 1.79 6.30 3.33 1.89 6.00 3.23 1.98 5.64 3.10 2.07 5.21 2.94 2.16 4.78 2.78 2.25 Cooling Indoor Model *FA4CN(F,C)024 1..01 1.01 FB4BN(F,L)024 1.00 1.00 COIL CONDENSER ENTERING TEMPERATURES C 23.89 29.44 35 40.56 46.11 51.67 CFM EWB Sens Sens Sens Sens Sens Sens 024--3A Outdoor Section With FA4CN(F,C)024 Indoor Section 14 6.54 6.54 2.03 6.24 6.24 2.16 5.93 5.93 2.28 5.63 5.63 2.41 5.33 5.33 2.55 5.01 5.01 2.69 330 17 6.72 6.26 2.05 6.35 6.06 2.17 5.99 5.86 2.29 5.64 5.64 2.42 5.33 5.33 2.55 5.01 5.01 2.69 19 7.53 5.29 2.10 7.09 5.12 2.23 6.62 4.91 2.37 6.22 4.75 2.50 5.80 4.57 2.63 5.38 4.40 2.76 22 8.20 4.21 2.15 7.88 4.10 2.29 7.47 3.95 2.44 6.98 3.76 2.59 6.51 3.59 2.73 6.07 3.43 2.88 14 6.83 6.83 2.09 6.49 6.49 2.23 6.16 6.16 2.35 5.84 5.84 2.49 5.53 5.53 2.63 5.19 5.19 2.77 380 17 6.93 6.70 2.10 6.51 6.44 2.23 6.16 6.16 2.35 5.84 5.84 2.49 5.53 5.53 2.63 5.19 5.19 2.77 19 7.66 5.59 2.15 7.23 5.43 2.28 6.74 5.24 2.42 6.31 5.06 2.55 5.88 4.89 2.68 5.46 4.71 2.82 22 8.28 4.34 2.19 7.98 4.26 2.34 7.60 4.14 2.49 7.11 3.96 2.64 6.61 3.78 2.79 6.15 3.61 2.93 14 7.07 7.07 2.15 6.70 6.70 2.29 6.35 6.35 2.42 6.02 6.02 2.56 5.69 5.69 2.70 5.34 5.34 2.84 425 17 7.08 7.08 2.15 6.70 6.70 2.29 6.35 6.35 2.42 6.02 6.02 2.56 5.69 5.69 2.70 5.34 5.34 2.84 19 7.75 5.87 2.19 7.34 5.74 2.33 6.86 5.56 2.47 6.38 5.36 2.61 5.95 5.18 2.74 5.52 5.00 2.87 22 8.34 4.47 2.24 8.06 4.41 2.39 7.69 4.32 2.54 7.21 4.15 2.69 6.70 3.97 2.84 6.20 3.79 2.99 Cooling Indoor Model *FA4CN(F,C)030 1..02 1.02 FB4BN(F,L)024 0.98 1.04 See notes on page 17 16

DETAILED COOLING CAPACITIES* (S.I.) CONTINUED COIL CONDENSER ENTERING TEMPERATURES C 23.89 29.44 35 40.56 46.11 51.67 CFM EWB Sens Sens Sens Sens Sens Sens 030--3A Outdoor Section With FA4CN(F,C)030 Indoor Section 14 8.38 8.38 2.62 8.02 8.02 2.79 7.64 7.64 2.95 7.26 7.26 3.12 6.86 6.86 3.30 6.44 6.44 3.47 415 17 8.61 8.04 2.64 8.16 7.80 2.80 7.70 7.54 2.96 7.25 7.25 3.12 6.86 6.86 3.29 6.44 6.44 3.47 19 9.61 6.78 2.69 9.08 6.56 2.87 8.52 6.33 3.05 8.01 6.11 3.22 7.48 5.89 3.39 6.93 5.67 3.55 22 10.47 5.38 2.74 10.09 5.25 2.94 9.58 5.07 3.13 8.96 4.83 3.33 8.38 4.62 3.51 7.82 4.41 3.69 14 8.74 8.74 2.70 8.33 8.33 2.87 7.94 7.94 3.04 7.54 7.54 3.22 7.12 7.12 3.39 6.68 6.68 3.57 470 17 8.86 8.59 2.70 8.35 8.33 2.87 7.94 7.94 3.04 7.54 7.54 3.22 7.12 7.12 3.39 6.68 6.68 3.57 19 9.78 7.17 2.75 9.25 6.98 2.94 8.67 6.74 3.12 8.13 6.52 3.29 7.59 6.29 3.46 7.03 6.06 3.62 22 10.58 5.56 2.80 10.22 5.47 3.00 9.74 5.32 3.20 9.13 5.10 3.39 8.52 4.87 3.58 7.93 4.66 3.76 14 9.05 9.05 2.76 8.60 8.60 2.95 8.19 8.19 3.12 7.77 7.77 3.30 7.34 7.34 3.48 6.88 6.88 3.66 530 17 9.06 9.06 2.76 8.60 8.60 2.95 8.19 8.19 3.12 7.77 7.77 3.30 7.33 7.33 3.48 6.88 6.88 3.66 19 9.90 7.54 2.81 9.39 7.38 3.00 8.78 7.14 3.18 8.22 6.91 3.35 7.67 6.68 3.52 7.10 6.44 3.69 22 10.65 5.73 2.86 10.31 5.67 3.06 9.86 5.54 3.26 9.26 5.34 3.46 8.60 5.10 3.65 8.00 4.89 3.83 Cooling Indoor Model *FA4CN(F,C)036 1.00 1.02 FB4BN(F,L)036 0.99 1.02 COIL CONDENSER ENTERING TEMPERATURES C 23.89 29.44 35 40.56 46.11 51.67 CFM EWB Sens Sens Sens Sens Sens Sens 036--3A, 5A Outdoor Section With FA4CN(F,C)036 Indoor Section 14 9.75 9.75 3.11 9.34 9.34 3.28 8.94 8.94 3.47 8.53 8.53 3.67 8.10 8.10 3.87 7.65 7.65 4.07 495 17 10.07 9.27 3.13 9.58 8.99 3.30 9.07 8.72 3.48 8.58 8.43 3.67 8.09 8.09 3.86 7.65 7.65 4.07 19 11.18 7.82 3.18 10.69 7.58 3.39 10.09 7.33 3.60 9.52 7.09 3.79 8.95 6.85 3.99 8.35 6.61 4.19 22 12.14 6.16 3.24 11.83 6.05 3.47 11.32 5.89 3.69 10.67 5.64 3.92 10.04 5.41 4.13 9.42 5.18 4.35 14 10.15 10.15 3.20 9.71 9.71 3.38 9.28 9.28 3.58 8.85 8.85 3.78 8.40 8.40 3.98 7.94 7.94 4.19 565 17 10.34 9.89 3.20 9.81 9.57 3.40 9.29 9.29 3.58 8.85 8.85 3.78 8.40 8.40 3.98 7.94 7.94 4.19 19 11.41 8.22 3.26 10.91 8.06 3.47 10.25 7.80 3.68 9.67 7.55 3.87 9.08 7.31 4.08 8.48 7.06 4.28 22 12.25 6.36 3.31 11.97 6.30 3.54 11.50 6.15 3.77 10.89 5.94 4.00 10.20 5.68 4.23 9.56 5.45 4.45 14 10.49 10.49 3.27 10.02 10.02 3.48 9.57 9.57 3.68 9.12 9.12 3.88 8.66 8.66 4.09 8.18 8.18 4.31 635 17 10.57 10.39 3.28 10.03 10.03 3.49 9.57 9.57 3.68 9.12 9.12 3.88 8.65 8.65 4.09 8.17 8.17 4.31 19 11.53 8.61 3.33 11.06 8.49 3.55 10.41 8.25 3.76 9.79 7.99 3.96 9.18 7.74 4.16 8.57 7.48 4.37 22 12.32 6.51 3.38 12.07 6.50 3.61 11.62 6.39 3.85 11.03 6.21 4.08 10.32 5.95 4.31 9.65 5.71 4.53 Cooling Indoor Model *FA4CN(F,C)042 1.02 1.02 FB4BN(F,L)036 0.98 1.03 See notes on page 17 17

DETAILED COOLING CAPACITIES* (S.I.) CONTINUED COIL CONDENSER ENTERING TEMPERATURES C 23.89 29.44 35 40.56 46.11 51.67 CFM EWB Sens Sens Sens Sens Sens Sens 042--3B, 5A Outdoor Section With FA4CN(F,C)042 Indoor Section 14 11.25 11.25 3.61 10.87 10.87 3.94 10.46 10.46 4.29 10.02 10.02 4.69 9.56 9.56 5.13 9.07 9.07 5.60 580 17 11.68 10.57 3.64 11.21 10.33 3.98 10.71 10.07 4.33 10.17 9.78 4.71 9.62 9.47 5.14 9.07 9.07 5.60 19 12.80 8.83 3.73 12.35 8.66 4.08 11.81 8.44 4.46 11.22 8.19 4.86 10.58 7.92 5.27 9.92 7.65 5.74 22 13.77 6.98 3.82 13.48 6.90 4.18 13.02 6.73 4.57 12.44 6.52 5.00 11.77 6.26 5.46 11.03 5.99 5.92 14 11.67 11.67 3.73 11.27 11.27 4.07 10.85 10.85 4.43 10.38 10.38 4.82 9.89 9.89 5.26 9.38 9.38 5.74 660 17 11.92 11.25 3.74 11.45 10.99 4.09 10.94 10.71 4.45 10.39 10.39 4.82 9.89 9.89 5.26 9.37 9.37 5.74 19 12.99 9.31 3.83 12.56 9.16 4.18 12.01 8.96 4.56 11.39 8.70 4.97 10.73 8.43 5.38 10.05 8.15 5.85 22 13.88 7.18 3.91 13.64 7.15 4.28 13.20 7.01 4.67 12.63 6.82 5.10 11.96 6.58 5.56 11.21 6.30 6.06 14 12.01 12.01 3.83 11.62 11.62 4.18 11.17 11.17 4.56 10.68 10.68 4.95 10.17 10.17 5.38 9.63 9.63 5.87 745 17 12.12 11.83 3.84 11.64 11.64 4.18 11.17 11.17 4.56 10.68 10.68 4.95 10.17 10.17 5.38 9.62 9.62 5.86 19 13.12 9.74 3.92 12.71 9.64 4.27 12.16 9.45 4.65 11.52 9.20 5.07 10.84 8.91 5.49 10.15 8.62 5.95 22 13.94 7.36 3.99 13.73 7.37 4.36 13.32 7.27 4.76 12.76 7.10 5.19 12.09 6.87 5.66 11.33 6.59 6.16 Cooling Indoor Model *FA4CN(F,C)048 1.02 1.02 FB4BN(F,L)048 1.00 1.00 COIL CONDENSER ENTERING TEMPERATURES C 23.89 29.44 35 40.56 46.11 51.67 CFM EWB Sens Sens Sens Sens Sens Sens 048--3B, 5A Outdoor Section With FA4CN(F,C)048 Indoor Section 14 12.97 12.97 3.90 12.49 12.49 4.24 11.99 11.99 4.64 11.47 11.47 5.07 10.90 10.90 5.54 10.28 10.28 6.04 660 17 13.39 12.28 3.92 12.80 11.97 4.28 12.19 11.65 4.66 11.56 11.31 5.08 10.90 10.90 5.54 10.28 10.28 6.04 19 14.69 10.26 4.01 14.09 10.02 4.38 13.41 9.73 4.78 12.71 9.44 5.22 11.97 9.13 5.69 11.16 8.79 6.18 22 15.90 8.12 4.10 15.43 7.96 4.48 14.83 7.75 4.90 14.11 7.48 5.36 13.34 7.20 5.85 12.47 6.86 6.38 14 13.46 13.46 4.02 12.95 12.95 4.38 12.42 12.42 4.78 11.87 11.87 5.21 11.27 11.27 5.69 10.63 10.63 6.19 755 17 13.67 13.08 4.03 13.07 12.74 4.39 12.44 12.42 4.78 11.87 11.87 5.21 11.27 11.27 5.69 10.63 10.63 6.19 19 14.91 10.83 4.11 14.33 10.61 4.49 13.62 10.34 4.89 12.89 10.04 5.34 12.13 9.72 5.80 11.30 9.38 6.29 22 16.04 8.38 4.20 15.60 8.26 4.59 15.03 8.08 5.01 14.31 7.83 5.46 13.52 7.55 5.96 12.65 7.22 6.49 14 13.85 13.85 4.13 13.33 13.33 4.50 12.78 12.78 4.90 12.21 12.21 5.35 11.59 11.59 5.82 10.92 10.92 6.33 850 17 13.93 13.70 4.15 13.34 13.34 4.50 12.77 12.77 4.90 12.20 12.20 5.35 11.59 11.59 5.82 10.91 10.91 6.33 19 15.07 11.37 4.21 14.49 11.19 4.59 13.79 10.93 4.99 13.03 10.62 5.44 12.26 10.29 5.92 11.42 9.94 6.41 22 16.13 8.62 4.30 15.72 8.54 4.69 15.16 8.40 5.11 14.45 8.17 5.56 13.66 7.89 6.06 12.79 7.59 6.59 Cooling Indoor Model *FA4CN(F,C)060 1.02 1.02 FB4BN(F,L)048 0.98 1.03 FB4BN(F,L)060 1.00 1.06 See notes on page 17 18

DETAILED COOLING CAPACITIES* (S.I.) CONTINUED COIL CONDENSER ENTERING TEMPERATURES C 23.89 29.44 35 40.56 46.11 51.67 CFM EWB Sens Sens Sens Sens Sens Sens 0060--3A, 5A Outdoor Section With FA4CN(F,C)060 Indoor Section 14 15.66 15.66 4.83 15.09 15.09 5.28 14.51 14.51 5.79 13.91 13.91 6.34 13.26 13.26 6.94 12.56 12.56 7.56 825 17 16.17 14.91 4.86 15.44 14.52 5.31 14.72 14.15 5.81 14.00 13.75 6.35 13.27 13.27 6.94 12.56 12.56 7.56 19 17.83 12.47 4.92 17.11 12.18 5.41 16.22 11.79 5.95 15.39 11.45 6.49 14.54 11.09 7.09 13.64 10.72 7.71 22 19.37 9.86 5.01 18.80 9.67 5.50 18.08 9.41 6.04 17.20 9.08 6.63 16.20 8.70 7.27 15.22 8.33 7.92 14 16.29 16.29 4.97 15.66 15.66 5.46 15.02 15.02 5.96 14.39 14.39 6.52 13.71 13.71 7.12 12.98 12.98 7.75 945 17 16.51 15.91 4.98 15.78 15.47 5.47 15.03 15.03 5.96 14.39 14.39 6.52 13.71 13.71 7.12 12.98 12.98 7.75 19 18.09 13.16 5.05 17.38 12.91 5.54 16.55 12.58 6.08 15.59 12.17 6.64 14.72 11.82 7.23 13.80 11.43 7.86 22 19.56 10.19 5.14 19.03 10.04 5.64 18.32 9.81 6.18 17.47 9.52 6.76 16.48 9.16 7.40 15.39 8.75 8.07 14 16.78 16.78 5.11 16.17 16.17 5.61 15.45 15.45 6.12 14.78 14.78 6.68 14.07 14.07 7.29 13.32 13.32 7.93 1060 17 16.79 16.79 5.11 16.16 16.16 5.60 15.45 15.45 6.12 14.77 14.77 6.68 14.07 14.07 7.29 13.32 13.32 7.93 19 18.27 13.81 5.18 17.57 13.60 5.67 16.75 13.30 6.21 15.74 12.87 6.78 14.85 12.50 7.38 13.92 12.11 8.01 22 19.68 10.49 5.27 19.17 10.39 5.77 18.48 10.19 6.31 17.65 9.92 6.90 16.64 9.57 7.53 15.57 9.18 8.21 Cooling Indoor Model *FB4BN(F,L)060 0.99 1.02 NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. { and sensible capacities are net capacities. Blower motor heat has been subtracted. } Sensible capacities shown are based on 80 F (27 C) entering air at the indoor coil. For sensible capacities at other than 80 F (27 C), deduct 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80 F (27 C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per degree above 80 F (27 C). ** Unit kw is total of indoor and outdoor unit kilowatts. EWB --- Entering Wet Bulb 19

HEAT PUMP HEATING PERFORMANCE (ENGLISH) OUTDOOR COIL ENTERING TEMPERATURES F --- 3 7 17 27 37 47 57 67 EDB CFM kw kw kw kw kw 018---3A Outdoor Section With FA4CN(F,C)018 Indoor Section 65 70 75 Pow er kw Pow er kw 525 7.03 6.47 1.37 9.43 8.67 1.44 11.75 10.72 1.49 14.03 12.46 1.55 16.12 14.67 1.60 18.08 18.08 1.66 20.01 20.01 1.74 21.88 21.88 1.84 600 7.26 6.68 1.41 9.72 8.93 1.47 12.08 11.01 1.52 14.39 12.78 1.57 16.50 15.02 1.62 18.49 18.49 1.68 20.42 20.42 1.75 22.36 22.36 1.84 675 7.48 6.88 1.44 9.95 9.15 1.50 12.36 11.27 1.55 14.70 13.05 1.59 16.82 15.30 1.64 18.82 18.82 1.70 20.75 20.75 1.77 22.59 22.59 1.84 525 6.37 5.86 1.37 8.84 8.12 1.44 11.18 10.19 1.50 13.49 11.98 1.56 15.63 14.22 1.62 17.58 17.58 1.69 19.50 19.50 1.76 21.35 21.35 1.86 600 6.61 6.08 1.40 9.12 8.38 1.47 11.50 10.49 1.53 13.86 12.31 1.58 16.02 14.57 1.64 18.00 18.00 1.70 19.95 19.95 1.78 21.84 21.84 1.87 675 6.81 6.27 1.44 9.35 8.59 1.50 11.78 10.74 1.56 14.16 12.58 1.61 16.33 14.86 1.66 18.33 18.33 1.72 20.27 20.27 1.79 22.19 22.19 1.88 525 5.67 5.22 1.36 8.23 7.56 1.44 10.61 9.67 1.51 12.93 11.48 1.57 15.09 13.73 1.64 17.08 17.08 1.71 18.99 18.99 1.78 20.82 20.82 1.88 600 5.88 5.41 1.39 8.50 7.81 1.47 10.91 9.95 1.54 13.30 11.81 1.60 15.51 14.11 1.66 17.50 17.50 1.72 19.43 19.43 1.79 21.34 21.34 1.89 675 6.09 5.60 1.43 8.73 8.02 1.50 11.18 10.19 1.57 13.61 12.09 1.62 15.83 14.41 1.68 17.84 17.84 1.74 19.77 19.77 1.81 21.70 21.70 1.90 Cooling Indoor Model *FA4CN(F,C)024 1.01 0.98 FB4BN(F,L)024 1.00 1.00 Pow er kw EDB CFM 65 70 75 OUTDOOR COIL ENTERING TEMPERATURES F 3 7 17 27 37 47 57 67 kw kw kw kw kw 024---3A Outdoor Section With FA4CN(F,C)024 Indoor Section kw kw 700 8.93 8.21 1.53 11.50 10.56 1.63 14.17 12.92 1.72 16.95 15.06 1.82 19.97 18.17 1.94 23.03 23.03 2.05 26.17 26.17 2.17 28.38 28.38 2.25 800 9.16 8.43 1.57 11.74 10.79 1.66 14.47 13.20 1.75 17.29 15.36 1.84 20.31 18.48 1.95 23.51 23.51 2.07 26.04 26.04 2.14 27.82 27.82 2.20 900 9.35 8.60 1.61 11.96 10.99 1.70 14.74 13.44 1.78 17.58 15.61 1.87 20.68 18.82 1.98 23.70 23.70 2.07 25.69 25.69 2.13 27.16 27.16 2.17 700 8.48 7.80 1.54 11.05 10.16 1.65 13.71 12.50 1.75 16.51 14.66 1.85 19.47 17.72 1.97 22.49 22.49 2.09 25.81 25.81 2.23 28.26 28.26 2.32 800 8.70 8.00 1.58 11.31 10.39 1.68 14.00 12.76 1.78 16.81 14.93 1.87 19.87 18.08 1.99 23.00 23.00 2.11 25.88 25.88 2.21 27.81 27.81 2.27 900 8.90 8.18 1.62 11.53 10.59 1.72 14.26 13.00 1.81 17.16 15.24 1.91 20.12 18.31 2.00 23.32 23.32 2.12 25.67 25.67 2.19 27.28 27.28 2.24 700 8.02 7.38 1.56 10.61 9.75 1.67 13.28 12.11 1.78 16.05 14.25 1.89 18.98 17.27 2.01 21.97 21.97 2.13 25.36 25.36 2.28 28.01 28.01 2.39 800 8.23 7.57 1.60 10.86 9.98 1.70 13.55 12.36 1.81 16.35 14.52 1.91 19.31 17.57 2.02 22.46 22.46 2.15 25.60 25.60 2.26 27.73 27.73 2.34 900 8.43 7.76 1.63 11.07 10.18 1.74 13.79 12.58 1.84 16.66 14.79 1.94 19.62 17.86 2.04 22.81 22.81 2.17 25.55 25.55 2.25 27.31 27.31 2.31 Cooling Indoor Model *FA4CN(F,C)030 1.01 1.01 FB4BN(F,L)024 0.99 1.03 kw See notes on page 23 20

HEAT PUMP HEATING PERFORMANCE (ENGLISH) CONTINUED OUTDOOR COIL ENTERING TEMPERATURES F EDB CFM 65 70 75 3 7 17 27 37 47 57 67 kw kw kw kw 030---3A Outdoor Section With FA4CN(F,C)030 Indoor Section kw kw kw 875 11.02 10.14 2.04 14.28 13.12 2.15 17.69 16.13 2.26 21.31 18.93 2.36 25.17 22.90 2.48 29.33 29.33 2.60 33.96 33.96 2.75 37.86 37.86 2.85 1000 11.30 10.39 2.09 14.59 13.41 2.20 18.05 16.46 2.30 21.70 19.27 2.39 25.63 23.33 2.50 29.92 29.92 2.63 34.16 34.16 2.73 37.24 37.24 2.80 1125 11.54 10.62 2.14 14.87 13.66 2.24 18.37 16.75 2.34 22.07 19.60 2.43 26.02 23.68 2.53 30.33 30.33 2.65 33.95 33.95 2.72 36.51 36.51 2.77 875 10.45 9.62 2.05 13.72 12.61 2.17 17.13 15.62 2.29 20.76 18.44 2.40 24.56 22.35 2.52 28.68 28.68 2.65 33.27 33.27 2.81 37.60 37.60 2.93 1000 10.72 9.87 2.10 14.02 12.89 2.22 17.50 15.96 2.33 21.18 18.81 2.44 25.03 22.77 2.55 29.20 29.20 2.67 33.74 33.74 2.80 37.17 37.17 2.88 1125 10.97 10.09 2.16 14.31 13.15 2.27 17.81 16.24 2.37 21.51 19.10 2.47 25.41 23.13 2.58 29.69 29.69 2.70 33.74 33.74 2.80 36.59 36.59 2.85 875 9.87 9.08 2.07 13.17 12.10 2.20 16.58 15.12 2.32 20.19 17.93 2.44 24.00 21.84 2.57 28.03 28.03 2.71 32.52 32.52 2.86 37.14 37.14 3.01 1000 10.13 9.32 2.12 13.46 12.37 2.24 16.93 15.43 2.36 20.59 18.29 2.48 24.43 22.23 2.59 28.55 28.55 2.72 33.19 33.19 2.87 36.99 36.99 2.97 1125 10.38 9.55 2.17 13.73 12.62 2.29 17.24 15.72 2.40 20.95 18.60 2.51 24.81 22.58 2.62 28.98 28.98 2.75 33.41 33.41 2.87 36.55 36.55 2.94 Cooling Indoor Model *FA4CN(F,C)036 1.01 1.01 FB4BN(F,L)036 1.00 1.03 kw EDB CFM 65 70 75 OUTDOOR COIL ENTERING TEMPERATURES F 3 7 17 27 37 47 57 67 kw kw kw kw 036---3A, 5A Outdoor Section With FA4CN(F,C)036 Indoor Section kw kw kw 1050 13.86 12.75 2.41 17.86 16.41 2.56 22.00 20.06 2.69 26.38 23.43 2.84 30.91 28.13 3.00 35.76 35.76 3.17 41.29 41.29 3.39 46.11 46.11 3.56 1200 14.23 13.09 2.48 18.28 16.80 2.62 22.46 20.48 2.75 26.92 23.91 2.89 31.49 28.66 3.04 36.43 36.43 3.22 41.53 41.53 3.38 45.51 45.51 3.52 1350 14.56 13.40 2.55 18.64 17.13 2.68 22.86 20.84 2.80 27.32 24.27 2.94 31.94 29.06 3.09 36.87 36.87 3.26 41.42 41.42 3.39 44.91 44.91 3.50 1050 13.14 12.09 2.42 17.19 15.79 2.58 21.40 19.51 2.73 25.73 22.86 2.88 30.30 27.57 3.05 35.06 35.06 3.23 40.59 40.59 3.47 45.80 45.80 3.65 1200 13.50 12.42 2.49 17.59 16.17 2.64 21.80 19.88 2.78 26.21 23.28 2.93 30.83 28.05 3.09 35.60 35.60 3.26 41.07 41.07 3.46 45.43 45.43 3.61 1350 13.84 12.73 2.56 17.98 16.52 2.70 22.21 20.25 2.84 26.63 23.66 2.98 31.28 28.47 3.14 36.20 36.20 3.32 41.15 41.15 3.47 44.94 44.94 3.60 1050 12.39 11.40 2.43 16.50 15.17 2.60 20.73 18.90 2.76 25.03 22.23 2.92 29.68 27.00 3.10 34.36 34.36 3.29 39.74 39.74 3.52 45.39 45.39 3.74 1200 12.75 11.73 2.50 16.91 15.54 2.66 21.17 19.30 2.82 25.53 22.68 2.97 30.19 27.47 3.14 34.91 34.91 3.31 40.43 40.43 3.54 45.25 45.25 3.71 1350 13.09 12.04 2.56 17.26 15.86 2.72 21.57 19.66 2.87 25.97 23.06 3.02 30.63 27.88 3.19 35.47 35.47 3.37 40.75 40.75 3.55 44.88 44.88 3.69 Cooling Indoor Model *FA4CN(F,C)042 1.02 1.02 FB4BN(F,L)036 1.01 1.04 kw See notes on page 23 21