Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

Similar documents
Honeywell Thermal Solutions COMBUSTION CATALOG

COMBUSTION CATALOG. Honeywell Thermal Solutions Honeywell Thermal Solutions Combustion Catalog

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

Honeywell Primary Control Cross Reference

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES RM7888A Relay Module

7800 SERIES RM7840E,G,L,M Relay Module

7800 SERIES RM7888A Relay Module

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES EC7823/RM7823 Relay Module

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

R7140G,L,M Burner Control Modules

Instructions For A and Flame Simulators

COMBUSTION SAFETY AND EFFICIENCY

LFL Series Burner Flame Safeguard Control

Sola Hydronic Control. An Eco-Friendly Solution.

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

7800 Series RM7888A Relay Module

THERMOSTATS THERMOSTATS HEATING AND COOLING

RAYPAK ILLUSTRATED PARTS LIST

Power Flame Incorporated

SERVICE TECHNICIAN ONLY read and follow completely.

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

CG Section and Base Assembly Series 1 through 12

Inventory Management Guide

7800 SERIES Relay Modules

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

YP7899C SERIES Burner Management Panel

Indirect gas-fired air heater

7800 SERIES EC7810A, EC7820A Relay Module

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

RM7838A 7800 SERIES Relay Modules

SERIES 19A. mith PRESSURIZED WET BASE

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Take The Test! Does Your Boiler Meet Code?

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

Centro-Matic Automated Lubrication Systems System Controls

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

LGB Gas fired boiler

Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004

RM7890; RM Vac 7800 SERIES Relay Modules

COMBUSTION. Safety Shutoff Valves. Do More for Less. Industrial Flame Monitoring. Easy Drop-In Replacement for Fireye MicroM

E110 FIREYE FLAME-MONITOR BURNER MANAGEMENT CONTROL FOR USE WITH THE MICROPROCESSOR-BASED EP AND EPD STYLE PROGRAMMER MODULES

CSD-1 COMMERCIAL BOILER CONTROLS

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Eclipse 90 UV Scanner Model A Version 1

Inventory Management Guide

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

ED510 DISPLAY MODULE. FOR USE WITH FIREYE FLAME-MONITOR AND MicroM BURNER MANAGEMENT CONTROLS DESCRIPTION INSTALLATION APPROVED

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

Statement of Responsibilities

S9360A, S9361A, S9380A, S9381A Integrated Boiler Controllers

S9361A, S9381A Integrated Boiler Controllers

Section 1 Overview. Introduction 1-1

RM7897A,C 7800 SERIES Relay Modules

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

North American Flame Detector Adapters 8832 through 8839 and Series R

Q7800H Integrated Burner Control Subpanel

OPERATING AND MAINTENANCE MANUAL

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

Eclipse Self-Check UV Scanner

FIREYE C9707A ALL FUEL SCANNER

Temperature & Humidity Controllers

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

C7005A,B Gas Pilot and Flame Rod Assemblies

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Fireye FLAME SCANNERS

WHEN TROUBLESHOOTING, PERFORM THE STEPS IN ORDER.

LAE10 LFE10. Use. Series 02

PENTAIR/PUREX TROPIC ISLE HEATER

EGH Series 5. Control Supplement. EGH-105 to EGH-125 Natural gas CSD-1 control system

BURNER MANAGEMENT CONTROLS

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

Power Flame Incorporated

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

FIREYE E210/211 FLAME-MONITOR

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

HEATING- Heating Accessories RW List Prices Page X - 1. Iron Body Red Fox B&G Circulator Pump. Bronze B&G Circulator Pumps

Specifications of V-Line burners

FIREYE FLAME SCANNERS

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

Spark Electrodes/Flame Sensors

MBCE-110/230UV Flame Sensor Module

Model 60200FR Gas Primary Control Data Sheet

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Parts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110

Dual Pressure Controls

Transcription:

Table of Contents Part Number Index MANUFACTURER Page MANUFACTURER Page 1 1271A 1271B -211-B15 182EA 2 220736B 5 5/8X10RL 5/8X12RL 5/8X18RL 5/8X24RL 5/8X36RL 5/8X48HDRL 5/8X60RL 6 CONBRACO 6012 WHEELER A A06-SA6 A08-SA1 C C554A1463 C607A1012 C607A1053 C607B1028 C7008A1174 C7027A1023 C7027A104 C7035A1023 C715A1010 C727A10 E SANDYS INDUSTRIAL GLASS SANDYS INDUSTRIAL GLASS SANDYS INDUSTRIAL GLASS SANDYS INDUSTRIAL GLASS SANDYS INDUSTRIAL GLASS SANDYS INDUSTRIAL GLASS SANDYS INDUSTRIAL GLASS DONGAN DONGAN E60-100 WESTWOOD E63-100 WESTWOOD E-AEBF WESTWOOD E-CT WESTWOOD E-EBF WESTWOOD E-ECF WESTWOOD E-RAC WESTWOOD E-SSN WESTWOOD F FS4-3 FS8-W L L4006A78 L4006A15 L4006E1067 L4006E101 L4008A1015 L4008E1156 L404F1078 L404F1102 L407B1041 L6006A1145 L6006C1018 L8100B1128 MCDONNELL & MILLER MCDONNELL & MILLER 14 14 14 7 7 17 8 8 10 12 12 12 5 5 5 5 5 5 12 12 12 L1B1050 LJH-0A M M436A11 M7284A1004 M174C1025 M184D1021 Q Q17A1050 Q17C100 Q17C1033 Q624A1014 Q7230A1005 Q7800A1005 R DONGAN R400-1/2 ROBERTS MANUFACTURING R400-3/4 ROBERTS MANUFACTURING R440-4 ROBERTS MANUFACTURING R440-5 ROBERTS MANUFACTURING R450-12 ROBERTS MANUFACTURING R7847A1025 R7847A1033 R7848A1008 R784A1015 R784A1023 R8184G400 R8184G4066 RM7830A102 RM7840L1018 RM780A1015 RM785A1014 RM785C1012 S S7800A1001 ST7800A10 ST7800A103 ST7800A1054 T T32-30 WESTWOOD V V4055A1007 V4055A108 V4055D101 V055A1055 12 8 7 7 7 7 11 11 11 8 7 4 15 15 15 15 15 3 3 3 3 3 10 10 2 2 1 1 1 3 4 4 4 6 6 6 6

BURNER/BOILER/COMMERCIAL/IN DUSTRIAL 1 BURNER CONTROLS 1 ON/OFF PRIMARY CONTROLS 1 ON/OFF PRIMARY W/PREPURGE 1 PROGRAMMERS 2 PROGRAMMING CONTROL 2 KEYBOARD DISPLAY MODULE 3 AMPLIFIERS 3 SUBBASE 4 TIMER - PLUG IN PURGE 4 FLAME ROD, IR, UV 5 GAS VALVES 6 ACTUATORS 6 MOD MOTORS 7 MOD MOTORS 7 ACCESSORIES 7 IGNITION 8 TRANSFORMERS 8 ACCESSORIES OIL 10 CONTROL 10 ACCESSORIES 10 PILOT BURNER 11 PILOT 11 PRESSURE CONTROLS/LIMITS 12 TEMPERATURE CONTROL/LIMITS AQUASTAT WELLS 14 STEAM 14 RELIEF 14 HYDRONIC 15 FLOAT VALVE 15 FLOAT VALVE ACCESSORIES 15 COMPONENTS FLOW SWITCH GAUGE GLASS Table of Contents Categorized Listing

BURNER CONTROLS ENTIRE SERIES AVAILABLE - CALL YOUR LOCAL BRANCH TO ORDER. ON/OFF PRIMARY CONTROLS Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications. NOTES DETAIL RM780A1015 INTERMITTENT PILOT MAIN FLAME ESTABLISHMENT: INTERMITTENT; PILOT FLAME ESTABLISHMENT: 4 SEC OR 10 SEC ON/OFF PRIMARY W/PREPURGE Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications. SIZE NOTES DETAIL RM785A1014 USED WITH 7800 SERIES INTERMITTENT PILOT MAIN FLAME ESTABLISHMENT: INTERMITTENT; PILOT FLAME ESTABLISHMENT: 4 SEC OR 10 SEC RM785C1012 USED WITH 7800 SERIES INTERRUPTED PILOT MAIN FLAME ESTABLISHMENT: 10 SEC; PILOT FLAME ESTABLISHMENT: 4 SEC OR 10 SEC 1

BURNER CONTROLS PROGRAMMERS Microprocessor-based integrated primary burner control for automatically fired gas, oil or combination fuel single burner applications. NOTES DETAIL RM7840L1018 INTERRUPTED 2ND STAGE PILOT VALVE MAIN FLAME ESTABLISHMENT: 10 SEC OR 15 SEC; PILOT FLAME ESTABLISHMENT: 4 SEC OR 10 SEC PROGRAMMING CONTROL Microprocessor-based integrated burner control for full modulation applications; provides automatic burner sequencing, flame supervision, system st NOTES DETAIL TIMING RM7830A102 ON/OFF POWER BURNER LOCKOUT; INTERRUPTED PILOT 30 SEC POST PURGE 2

BURNER CONTROLS KEYBOARD DISPLAY MODULE Provides current status of burner sequence, timing info, hold info & lockout info; selectable or preemptive messages. S7800A1001 AMPLIFIERS DETAIL IN ENGLISH COLOR NOTES DETAIL TIMING R7847A1025 GREEN USE WITH: C7004,C7005,C7007,C7008,C700,Q FLAME ROD.8 SEC OR 1.0 SEC R7847A1033 GREEN 17 USE WITH: GAS, RECTIFYING FLAME ROD C7004,C7005,C7007,C7008,C700,Q FLAME ROD 2 SEC TO 3 SEC 17-GAS,OIL,COAL: UV FLAME SENSOR C7012A, C R7848A1008 RED USE WITH: GAS, OIL, COAL: INFRARED (LEAD SULFIDE) C7015 INFRARED 2 SEC OR 3 SEC R784A1015 PURPLE USE WITH: GAS, OIL MINIPEEPER C7027A,C7035A,C7044 UV.8 SEC OR 1.0 SEC R784A1023 PURPLE USE WITH: GAS, OIL MINIPEEPER C7027A,C7035A,C7044 UV 2 SEC OR 3 SEC 3

BURNER CONTROLS SUBBASE Burner, panel or wall mount subbase for 7800 series relay modules and s7830a expanded enunciator. DETAIL Q7800A1005 PANEL MOUNT TIMER - PLUG IN PURGE Provides prepurge timing for select 7800 series relay modules, from 2 seconds to 45 seconds. ST7800A10 ST7800A103 ST7800A1054 TIMING 30 7 SEC 60 SEC 4

BURNER CONTROLS FLAME ROD, IR, UV Used to apply flame rod in gas-fired systems controlled by recitification type flame safeguard control, where SIZE COMMENT NOTES DETAIL MOUNTING: 1/4" NPT C7008A1174 12" ROD CONNECTIONS MALE; RAJAH USE WITH: R7247A, B, R7847A, ELECTRICAL B, R7257, R728 C7027A1023 C7027A104 C7035A1023 6" LEAD 6" LEAD 72" LEAD MOUNTING: INTEGRAL NUT FOR 1/2" SIGHTING PIPE MOUNTING: INTEGRAL NUT FOR 1/2" SIGHTING PIPE C715A1010 30" LEAD MOUNTING: 3/4" NPT C727A10 6" LEAD INCL: 1/2" NPT THREADED SPUD CONNECTOR MOUNTING: INTEGRAL USE WITH: R724A, B, R784A, NUT FOR 1" SIGHTING B, R774B, R725, R720 PIPE DETECTS UV RADIATION IN FLAMES INCL: MAGNIFYING LENS, 32007255-001 CELL USED WITH R7851B FLAME ROD AND HOLDER; FLAME ROD MINIPEEPER; UV MINIPEEPER; UV MINIPEEPER; UV LEAD SULFIDE; IR MINIPEEPER; UV 5

GAS VALVES ACTUATORS Used in combination with V5055 or V507 valves to control gas supply to commercial and industrial burners. Provides final safety shutoff. COMMENT PRESSURE RANGE NOTES DETAIL TIMING USE WITH: 26 SEC V4055A1007 V5055/V507A,B 5 PSI MAX DAMPER SHAFT: NO ON/OFF OPENING VALVE BODIES V4055A108 V4055D101 V055A1055 USE WITH: V5055/V507A,B VALVE BODIES USE WITH: PROOF OF CLOSURE V5055/V507C VALVE BODIES USE WITH V5055B VALVE BODIES 5 PSI MAX DAMPER SHAFT: YES ON/OFF 5 PSI MAX 5 PSI MAX LOW PRESSURE; DAMPER SHAFT: YES LOW PRESSURE; DAMPER SHAFT: YES ON/OFF; PROOF OF CLOSURE AUX SWITCH MODULATING-OFF SEC OPENING SEC OPENING OR 26 SECONDS 6

MOD MOTORS MOD MOTORS NOTES DETAIL TORQUE TIMING STROKE M436A11 2 POSITION, SPST 40 SEC MAX KIT MOUNTED; FOOT 20 LB-IN RUN TIME; 30 MOUNTED SEC OPENING 60-75 ADJ M7284A1004 150 LB-IN 30-60 SEC 0-0 ADJ M174C1025 2 AUX SWITCHES; INCL TRANSFORMER; REPLACES M171C1002 75 LB-IN 30-0 SEC 0-0 ADJ M184D1021 FOOT MOUNTED 150 LB-IN 30-60 SEC 0-0 ADJ ACCESSORIES 182EA 220736B Q7230A1005 DETAIL TRANSFORMER AUXILARY SWITCH KIT INTERFACE 7

IGNITION TRANSFORMERS A06-SA6 A08-SA1 LJH-0A DETAIL 120 VOLT PRIMARY, 6000 VOLT SEC 120 VOLT PRIMARY, 8500 VOLT SEC 120 VOLT PRIMARY, 10,000 VOLT SEC Q624A1014 DETAIL 120 VAC PRIMARY; USE ONLY IN INTERRUPTED IGNITION APPLIANCES 8

IGNITION ACCESSORIES DETAIL E60-100 UL LISTED IGNITION CABLE; BLACK; -40 F TO 140 F; 14 GAUGE E63-100 UL LISTED IGNITION CABLE, RED SILICONE, -61 F TO 482 F; GAUGE E-AEBF EXTENDED BAKELITE TERMINAL; ANGLE E-CT RAJAH CAGE TERMINAL E-EBF EXTENDED BAKELITE TERMINAL; ANGLE E-ECF HIGH TEMP CERAMIC SPARK PLUG BOOT W/ STAINLESS STEEL TERMINAL E-RAC RAJAH CAGE TERMINAL; ANGLE E-SSN RAJAH TERMINAL T32-30 CO2 CARTRIDGES; 8 GRAM; 800 PSI; BOX OF 10

OIL CONTROL NOTES DETAIL TIMING PROVIDES AUTO, RECYCLING CONTROL R8184G400 OF INTERMITTENT IGNITION OIL PROTECTO RELAY; 45 SEC SAFETY BURNER SYSTEM; INCL LED FOR SWITCH LOCKOUT INDICATION & MANUAL TRIP R8184G4066 LEVER LED FOR LOCKOUT INDICATION, MANUAL TRIP LEVER ON SAFETY SWITCH PROTECTO RELAY 15 SEC ACCESSORIES SIZE NOTES DETAIL 60" LEADS; ELEC CONN: NEC CADMIUM SULFIDE FLAME INCL: A,B,E,J & P MOUNTING C554A1463 CLASS 1, 2 FLAG 1/4" QUICK DETECTOR FOR SEQUENCING OIL BRACKETS & FUEL LINE ADAPTOR CONNECTS SYSTEMS 10

PILOT BURNER PILOT SIZE TYPE OF GAS NOTES DETAIL Q17A1050.028" ORIFICE NAT SIDE/END MOUNTING BRACKET INTERMITTENT OR INTERRUPTED IGNITION; "T" PORT & BURNER TIP STYLE Q17C100.026" ORIFICE NAT REAR MOUNTING BRACKET INTERMITTENT OR INTERRUPTED IGNITION; "D" PORT & BURNER TIP STYLE Q17C1033.026" ORIFICE NAT LEFT SIDE MOUNTING BRACKET INTERMITTENT OR INTERRUPTED IGNITION; "D" PORT & BURNER TIP 11

PRESSURE CONTROLS/LIMITS OUTLET PRESSURE RANGE PRESSURE RANGE NOTES DETAIL C607A1012 3-21 PSI 1/4" NPT INTERNAL THREAD C607A1053 3-21 PSI 1/4" NPT INTERNAL THREAD C607B1028 3-21 PSI 1/4" NPT INTERNAL THREAD L404F1078 L404F1102 L407B1041 L1B1050 85 MAX SUSTAINED OPERATING 225 MAX SUSTAINED OPERATING 225 MAX SUSTAINED OPERATING 225 MAX SUSTAINED OPERATING 5-50 PSI 10-150 PSI 1/4" NPT INTERNAL THREAD OR SURFACE MOUNT THROUGH BACK 1/4" NPT INTERNAL THREAD OR SURFACE MOUNT THROUGH BACK MANUAL RESET, BREAK ON PRESSURE FAIL AUTO RECYCLE, BREAK ON PRESSURE FAIL MANUAL RESET, BREAK ON PRESSURE RISE SPDT SNAP ACTION, MAKE R-W, BREAK R-B ON PRESSURE RISE SPDT SNAP ACTION, MAKE R-W, BREAK R-B ON PRESSURE RISE 10-150 PSI MANUAL RESET SPST BREAK ON PRESSURE RISE 5-150 PSI OPTIONAL SURFACE MOUNT THROUGH BACK SINGLE POTENTIOMETER 12

TEMPERATURE CONTROL/LIMITS AQUASTAT SIZE TEMP NOTES DETAIL L4006A78 3" CAP 100-240 DEG BULB: 3/8" X 2 7/8" COPPER LOCKED ROTOR: 48A @ 120VAC; 30.6A @ 240VAC L4006A15 3" CAP 40-180 DEG BULB: 3/8" X 2 7/8" COPPER FULL LOAD: 2.6A @ 120VAC; 1.3A @ 240VAC L4006E1067 3" CAP 0-270 DEG BULB: 3/8" X 2 7/8" COPPER LOCKED ROTOR: 48A @ 120VAC; 30.6A @ 240VAC L4006E101 3" CAP 0-270 DEG BULB: 3/8" X 2 7/8" COPPER LOCKED ROTOR: 48A @ 120VAC; 30.6A @ 240VAC L4008A1015 66" CAP 100-240 DEG BULB: 3/8" X 2 7/8" COPPER HIGH OR LOW LIMIT APPLICATION; SPST, CONTACTS BREAK ON TEMP RISE L4008E1156 66" CAP 0-270 DEG BULB: 3/8" X 2 7/8" COPPER HIGH LIMIT, MANUAL RESET; SPST, CONTACTS BREAK ON TEMP RISE; HEAT CONDUCTIVE COMPOUND FULL LOAD: 8A @ 120VAC; 5.1A L6006A1145 3" CAP 100-240 DEG BULB: 3/8" X 2 7/8" COPPER @ 240VAC CIRC CONTROL & HIGH OR LOW BULB: 3/8" X 2 7/8" COPPER; LIMIT; SPDT SWITCHING L6006C1018 65-200 DEG MOUNT: HORIZONTAL, ACTION; INCL FACTORY SET @ VERTICAL OR STRAP ON 200 L8100B1128 3" CAP 100-180 DEG HIGH LIMIT, 3" CAPILLARY, 1 1/2" INSULATION DEPTH IMMERSION WELL; SPST, CONTACTS BREAK ON TEMP RISE

TEMPERATURE CONTROL/LIMITS WELLS 1271A 1271B STEAM RELIEF DETAIL 1/2" NPT X 3" INSERTION 3/4" NPT X 3" INSERTION SIZE DETAIL -211-B15 3/4" 15 PSI; 41 LBS PER HOUR 14

HYDRONIC FLOAT VALVE SIZE MATERIAL R400-1/2 1/2" X 1/2" BRASS R400-3/4 3/4" X 3/4" MIP BRASS FLOAT VALVE ACCESSORIES SIZE DETAIL MATERIAL R440-4 1/4-20 SAE 4" FLOAT BALL COPPER R440-5 1/4-20 SAE 5" FLOAT BALL COPPER R450-12 1/4-20 SAE 12" ROD BRASS 15

COMPONENTS FLOW SWITCH Versatile controls actuated by liquid or air flow - widely used as automatic controllers. SIZE DETAIL FS4-3 1" NPT LIQUID; GENERAL PURPOSE FS8-W 1" NPT LIQUID; #120601; GENERAL PURPOSE Gaskets available upon request. GAUGE GLASS SIZE DETAIL 5/8X10RL 5/8" X 10" REDLINE 5/8X12RL 5/8" X 12" REDLINE 5/8X18RL 5/8" X 18" REDLINE 5/8X24RL 5/8" X 24" REDLINE 5/8X36RL 5/8" X 36" REDLINE 5/8X48HDRL 5/8" X 48" REDLINE 5/8X60RL 5/8" X 60" REDLINE

COMPONENTS GAUGE GLASS DETAIL 6012 CUTTER WITH CHAIN 17