PROGRESSIVTUBE PASSIVE SOLAR WATER HEATING SYSTEM

Similar documents
ProgressivTube PASSIVE SOLAR WATER HEATERS HOT OUT

E njoy... Quality Solar Heaters

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

Residential Solar Water Heater

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

General System Layout Sketch

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

Solar Water Heating Basics for Homeowners

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

Hydronic Product & Application Catalog

DRAINBACK DOMESTIC HOT WATER SOLAR SYSTEM WITH DIFFERENTIAL CONTROL MODELS SLCR60DC-80DB, SLCR64DC-80DB, SLCR80DC-80DB SLCR40DC-80DB & SLCR32DC-80DB

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Advanced Heating & Hot Water Systems. Solar Water Heating Clean Green Energy

SOLENE INSTALLATION MANUAL OPEN LOOP HOT WATER SOLAR SYSTEM WITH PHOTOVOLTAIC MODULE

ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES

SYSTEM DESIGN REQUIREMENTS

VALVES SECTION 15100

OG-300 Internal Coil Solar Hot Water Systems Schematics and Parts Lists

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Solar Hot Water & Hydronics

Solar Water Heaters. Bastián Acevedo Bustos. Electronic Engineering Student, Tarapacá University. Environmental Studies Student, York University

WAL-RICH CORPORATION SINCE 1950

Solar Boiler. Solar Domestic Hot Water System Technical Specifications SRCC Certification # A CSA # A. General Information

Section 2: Solar Water Heating Systems focuses primarily on the common solar system design types.

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

APPLICATIONS FOR HVAC SYSTEMS

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Owner Manual Pre-Heat Appliances Single Wall Heat Exchanger

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Packaged Semi-Instantaneous Steam Fired Water Heater

SOLENE INSTALLATION MANUAL OPEN LOOP HOT WATER SOLAR SYSTEM WITH DIFFERENTIAL CONTROL

INDIRECT FIRED WATER HEATERS

General System Layout Sketch

PIONEERS IN AIR VACUUMS

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

Value Pre-Heat Appliance Installation Manual

SRCC OG-300 Certified Solar Water Heating System

Soak in the Sunshine. Solar Hot Water

SECTION WATER HEATERS

SECTION PLUMBING EQUIPMENT

Automatic Temperature Controller (ATC)

Flow Factor ~

SUN EQUINOX HEATING SYSTEMS

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Residential Solar Heating Collectors

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Ultra Low Cost Solar Water Heater. Concept Generation and Selection Document

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

Troubleshooting the MPH 24FP Series Pedestal Hydrant

U.S. Department of Energy - Energy Efficiency and Renewable Energy

SOLAR HEATING SYSTEMS

Commercial Hot Water Maker

Evacuated Tube - Solar Collector

Solar water heating system

Models AP-10, AP-20 and AP-30

Safety vacuum drying oven for flammable solvents

Solar Hot Water Heating Systems

Hydronic Comfort Systems

MAXIMISER Semi-Storage Calorifiers

OVSOL Solar System Manual. Solar hot water system installation guide for evacuated tube systems.

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

A strong team A ++ A +++ ROTEX gas hybrid heat pump

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

using Solar energy efficient efficiency rate

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps

The intelligent alternative for flue gas venting systems

Silhouette. Feedwater Heater. Boiler Feedwater

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

2011 Solar Thermal Water Heating Solutions

Tepid Water Delivery System

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SECTION ELECTRIC WATER HEATERS

Tankless Water Heater Kits

SECTION SOLAR ENERGY HEATING SYSTEM

Accumulators - Suction Line

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

Solar Hot Water. PV + Heat Pump or Thermal. Which is better?

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

Powers TM Controls TH 188 Unit Mounted Thermostat

Thermostatic mixing valves with replaceable cartridge for centralized systems

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Easy Installation & Service

INSTALLATION INSTRUCTIONS

SOLAR HOT WATER HEATERS

Selecting a New Water Heater

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

EVACUATED TUBE SOLAR HOT WATER SYSTEMS OWNERS MANUAL JULY 2013 BROCMISC100.1

ACR Solar International Corp Gibbons Dr. Suite H Carmichael, CA (916) "Islander" Installation Manual

Solar. domestic hot water systems. Using the sun s energy to provide hot water

Zero Energy Home Design Project

Outdoor Reset Control Theory FULL versus PARTIAL reset

ORDINANCE NO BE IT ORDAINED BY THE BOARD OF COUNTY COMMISSIONERS OF HERNANDO COUNTY, FLORIDA:

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Transcription:

PASSIVE SOLAR WATER HEATING SYSTEM The value leader in solar thermal technology! Proudly made in the USA! Your authorized representative is: IN PROGRESSIV TUBE system qualifies for all Federal, State and Local financial incentives! OUT The PROGRESSIVTUBE passive solar water heater is a self-contained, single unit system that integrates the solar collector and storage tank. most applications, it functions as a pre-heater to an instantaneous or conventional water heater. The PROGRESSIVTUBE requires only local water pressure and solar radiation to operate. No pumps, controls, mechanical or electrical components are required. Once installed, the system will work automatically. When hot water is used, solar preheated water is drawn into the conventional water heater, reducing electrical or gas usage for water heating. The PROGRESSIV TUBE is among the most efficient solar systems rated by national testing and certification agencies. All PROGRESSIV TUBE systems meet or exceed all applicable national plumbing and building codes. Our systems are virtually maintenance free and feature a twenty-five year design life. Whether your purchase decisions depends on simple pay back, return on investment or life cycle analysis, PROGRESSIVTUBE can exceed your expectations. The all copper collector/storage tank absorbs solar radiation through its selective surface coating by raising the temperature of the water stored in the collector. It is well insulated with closed cell foam and double-glazed for increased heat retention. The diameter copper tubes are welded into a series flow pattern so that the top of the lower tube feeds the bottom of the next tube. This allows the collector to contain the colder replacement water in the lower tubes where it is heated by the sun as it flows from one tube to the next. Each time hot water is used, the innovative design eliminates the cooling down of the remaining heated water that normally occurs in other types of solar water heating systems. Not only does this design ensure the delivery of the hottest water, but it also provides more hot water at a higher temperature and with a faster recovery time than solar systems of similar capacity.

SPECIFICATIONS FLUID CONNECTION: let and connections are made of nominal ¾ diameter Type L hard copper pipes. This allows for fast, leak free sweat fitting plumbing connections. GLAZING GASKETS: A continuous gasket made of special long life EPDM synthetic rubber is compressed by the glazing caps to seal out the weather. The inner glazing spline is made of high-temperature tolerant EPDM. GLAZING: er glazing is tempered low-iron solar glass with % transmittance. ner glazing is Teflon film, known for its high temperature tolerance (525 F) and its long term durability and stability, transmittance %. The ¾ air space between glazings reduces heat loss. CASE: The baked-on bronze acrylic finish of the hard temper, T, extruded aluminum framewall and glazing caps, alloy 0, assures years of attractive rust-free appearance. All rivets and bolts are aluminum or stainless steel. Aluminum back sheet.025. INSULATION: Rigid closed cell polyisocyanurate foam board, the most efficient insulation available, is used to maximize heat retention. Sides and ends of the unit have.5 board, R- valve 0; bottom has 2 board, R-valve between tank tubes has.5 board, R-valve 0. ABSORBER/STORAGE TANK: Constructed entirely of copper, the diameter tubes are welded to the interconnecting pipes to form a series flow pattern. The tank is pressured rated to 00 psi and is coated with a high-temperature selective solar radiation absorption surface that maximizes heat gain and reduces heat loss. PROGRESSIVTUBE SYSTEMS PERFORMANCE RATINGS The PROGRESSIVTUBE and its mounting systems have successfully passed static wind load testing to 0 m.p.h. PROGRESSIV TUBE PT-0-CN, PT-0-CN and PT-50-CN models and/or systems meet the following standards: Florida Solar Energy Center (FSEC GP 5 0) (FSEC GP 0) (FSEC GP 0) ASHRAE 5- Thermal Performance Standard for Solar Water Heaters Solar Ratings & Certification Corp. SRCC Standard 200- (RA 2) SRCC OG 00 Uniform Solar Energy Code ternational Association of Plumbing & Mechanical Officials MODEL FSEC Qnet SRCC Solar Energy Factor BTU/Day KWh PT-20-CN,00.0.0 PT-0-CN 22,00.. PT-0-CN 2,00.. PT-50-CN 2,00.2.

SPECIFICATIONS PT-20CN PT-0-CN PT-0-CN PT-50-CN Volumetric Capacity.2 liters /. gal.. liters / 0. gal. 5. liters /.0 gal..2 liters /.2 gal. Gross Area. m 2 / 2.5 ft 2 2.2 m 2 / 2. ft 2 2. m 2 / 2.0 ft 2 2. m 2 / 2.0 ft 2 Transp. Frontal Area.00 m 2 / 0. ft 2 2.0 m 2 / 2. ft 2 2. m 2 / 2. ft 2 2. m 2 / 2. ft 2 Dry Weight. kg / 2 lbs.2 kg / lbs. kg / 220 lbs 20.0 kg / 25 lbs Wet Weight 0. kg / 2. lbs 2. kg / 25 lbs 255. kg / 5 lbs 0.0 kg / lbs Flow Pattern Series Series Series Series Test Pressure 20 KPa / 00 psi 20 KPa / 00 psi 20 KPa / 00 psi 20 KPa / 00 psi Design Pressure 0 KPa / 50 psi 0 KPa / 50 psi 0 KPa / 50 psi 0 KPa / 50 psi Max. Design Temp. C / 50 F C / 50 F C / 50 F C / 50 F Normal Oper Temp. C to C / 0 F to 200 F C to C / 0 F to 200 F C to C / 0 F to 200 F C to C / 0 F to 200 F DIMENSIONS METRIC / INCHES A 22. cm /.5 2.5 cm /. 2.5 cm /. 2.5 cm /. B 55.25 cm / 2.52 0.0 cm / 5. 20.5 cm /. 20.5 cm /. C 20. cm /.5 2. cm / 5.25 2. cm / 5.25 2. cm / 5.25 D. cm /.. cm /.25. cm / 5.25. cm / 5.25 E 25.2 cm /.5 250.0 cm /. 250.0 cm /. 250.0 cm /. F. cm /.5. cm /.5. cm /.5. cm /.5 G 22.5 cm /. 2.2 cm /.25 2.2 cm /.25 2.2 cm /.25 H. cm / 2.5. cm / 2.5. cm / 2.5. cm / 2.5 I 2.5 cm /.0 2.5 cm /.0 2.5 cm /.0 2.5 cm /.0 J. cm /.5. cm /.5. cm /.5. cm /.5 K. cm /.0. cm /.0. cm /.0. cm.0 L. cm / 5.5. cm / 5.5. cm / 5.5. cm / 5.5 M.2 cm /.25 0.5 cm / 2.5 00. cm /.5 00. cm /.5 N 5. cm / 2.25. cm / 5.25 20.2 cm /.25 20.2 cm /.25 p.2 cm /.25.2 cm /.25.2 cm /.25.2 cm /.25 Q 5. cm /.25 5. cm /.25 5. cm /.25 5. cm /.25 R.2 cm / 2..2 cm / 2..2 cm / 2.2 cm / 2. A K L J B D M N C P E Q R F H G I

-Way System (-Way valve comes with or without anti-scald) PLUMBING VALVE KIT COMPONENTS Qty Description Part No. Aquamix Anti-Scald Valve (/ ) ASV Cast Bronze T Fittings (/ ) BZT ¾ *Gas water heaters must use the Anti-Scald Valve. Please consult our stallation Manual for plumbing schematics. 2 Bronze Boiler Drains BD Pressure Relief Valve (50 PSI) PRV Full Port 2-Way Ball Valve (/ ) BV2Way 2 Full Port -Way Ball Valve (/ ) BVWay Vacuum Breaker (/2 ) VCB Cast Bronze T Fitting (/2 ) BZT ½ 2-Way System (2-Way valve comes with or without anti-scald) *Gas water heaters must use the Anti-Scald Valve. Please consult our stallation Manual for plumbing schematics. Qty Description Part No. Aquamix Anti-Scald Valve (/ ) ASV Cast Bronze T Fittings (/ ) BZT ¾ 2 Bronze Boiler Drains BD Pressure Relief Valve (50 PSI) PRV Full Port 2-Way Ball Valve (/ ) BV2Way Full Port -Way Ball Valve (/ ) BVWay Vacuum Breaker (/2 ) VCB Cast Bronze T Fitting (/2 ) BZT ½

PROGRESSIVTUBE 2 WAY SYSTEM FOR ELECTRIC WATER HEATER PLUMBING DIAGRAMS SRCC OG-00 -WAY SYSTEM let 2 let 0 let 2A 2B 0 let 2 WAY SYSTEM FOR GAS WATER HEATER 2 WAY SYSTEM FOR TANKLESS WATER HEATER 0 0 let 2 let let 2 DIRECT SOLAR SYSTEM 0 ITEM LIST - Supply shut off valve 2- -way Ball Valve - 2-way Ball Valve - Tempering Valve or Mixing Valve 5- Boiler Drains - Pressure Relief Valve - Water Heater - Pressure Relief Valve - Roof Flashing 0- Vacuum Breaker - ProgressivTube

MOUNTING SYSTEMS A) Mounting system for pitch roof: PTMS () Clamps () / x Bolts () / x 2-¼ Bolts () / Lock Nuts () UMB B) Mounting system for flat roof: PTMS with STS (2) Alum Sq. Tubes (2) / x 2 ¼ Bolts (2) / Lock Nuts C) Mounting system for pitch roof, collector set flush in the roof: FHMS () Clamps 0 Copeland Street, Jacksonville, Florida 220. www.tctsolar.com info@tctsolar.com rev 0-200